• Title/Summary/Keyword: tunnel establishment

Search Result 67, Processing Time 0.026 seconds

Analysis of Ground Deformation Deformation using Resistivity Monitoring Technique at a Tunnel Excavation Area (전기비저항 모니터링을 이용한 터널 주변 지반상태 변화 파악)

  • Ahn, Hee-Yoon;Jeong, Jae-Hyeung;Cho, In-Ky;Park, Sam-Gyu;Kim, Ki-Seog;Jung, Lae-Chul
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2007.06a
    • /
    • pp.93-100
    • /
    • 2007
  • During tunnel excavation, drawdown of groundwater table or discharge from tunnel faces may not only reduce stability of tunnel and work efficiency but cause environmental problems. We have investigated the applicability of electrical resistivity survey for the establishment of the monitoring system for groundwater behavior and detecting flow channel of groundwater during tunnel excavation. The groundwater level was continuously measured at several points for 1 year. Survey was conduted at every 3 months using preinstalled electrical resistivity cables on site. The results show that observed changes in resistivity ratios in the area can be explained with observed changes in groundwater level. Thus, we believed that electrical resistivity analysed together with groundwater data can be applied for the monitoring of groundwater in tunnel area.

  • PDF

Controlled Bandwidth Borrowing with Extended RSVP-TE to Maximize Bandwidth Utilization

  • Kim Chul;Kim Young-Tak
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.1B
    • /
    • pp.64-72
    • /
    • 2004
  • Multiprotocol Label Switching (MPLS) has been developed as a key technology to enhance the reliability, manageability and overall quality of service of core If networks with connection-oriented tunnel LSP and traffic engineering such as constraint-based routing, explicit routing, and restoration. In this paper, we propose a control bandwidth borrowing scheme that maximizes the utilization of tunnel LSPs or physical links by an extension to the RSVP-TE label distribution protocol. MPLS-based core switching network and VPN services rely on the establishment of connection-oriented tunneled LSPs that are configured or predefined by network management systems. The mechanism of network management system varies from (i) a relatively static LSP establishment accounting, to (ii) a dynamic QoS routing mechanisms. With the use of hierarchical LSPs, the extra bandwidth that is unused by the trunk (outer) LSPs should be fully allocated to their constituent end-to-end user traffic (inner) LSPs in order to maximize their utilization. In order to find out the unused extra bandwidth in tunnel LSP or physical link and redistribute these resources to constituent LSPs, we expend the functionality of RSVP-TE and the found unused extra bandwidth is redistributed with a weight-based recursive redistribution scheme. By the extended RSVP-TE and proposed recursive redistributed scheme, we could achieve the instantaneous maximized utilization of tunnel LSP or physical link suffering from the potential under-utilization problem and guarantee the end-to-end QoS requirements. With the proposed scheme, network manager can manage more effectively the extra available bandwidth of hierarchical LSPs and maximize the instantaneous utilization of the tunneled LSP resources.

A Study on the Procedures and Application Examples for Establishment of Master Plan Standard for the Utility Tunnel (공동구 기본계획 기준수립을 위한 절차 및 적용사례에 대한 연구)

  • Oh, Wonjoon;Cho, Choongyeun;Lee, Minjae
    • Korean Journal of Construction Engineering and Management
    • /
    • v.21 no.4
    • /
    • pp.100-107
    • /
    • 2020
  • In this paper, a study was conducted on the method of establishing the master plan standard for rational decision-making about utility tunnel construction in the existing urban. In the previous study, the optimal route was selected by the feasibility assessment. However, in order to increase the objectivity of the installation conditions of the utility tunnel in the master plan standard, comprehensive evaluation of the results by feasibility and economics analysis calculates the overall ranking for all sections analyzed. In addition, based on the results of the comprehensive evaluation, a method for establishing a mid·long term investment plan was introduced after reviewing the project to be conducted in the region. Additionally, in order to review the establishment of the standard suggested in the paper, an analysis was conducted by applying the master plan procedure to the northwestern urban zone of seoul.

New Construction and Design Method of Two Arch Tunnel (최신 투 아치 터널의 굴착 공법과 구조 및 설계)

  • Yun, Seok-Ryul;Kwon, Oh-Hyun;Seo, Dong-Hyun
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2004.03b
    • /
    • pp.938-945
    • /
    • 2004
  • In order to cope with ever growing traffic flow and complexity in the urban area, construction demands for expanding and realigning of existing urban roads and massive development of underground space within the urban area are in its increasing trend, it is fact that, mainly due to lack of statistical data accumulation through real construction, technology and construction practice to support such demands can hardly be said to have been established enough and leave many things still to be developed. These circumstances therefore came to motivate me to get into a study for a particular subject of "Design Basics for Closely Neighbored Twin Tunnel" among others, and also to put forward subjects required to be further studied in this connection in the future as follows: 1) To make a new economical design model for closely neighbored twin tunnel not only to make a drain for center perfect but also a tunnel construction safe. 2) Further efforts should be exerted for establishment of general standards for design and construction of various types of large cross-section tunnels including Twin structure.

  • PDF

A study on effects of landscape design of road tunnel portal to interior lighting of tunnels (도로터널의 갱구부 경관설계가 터널 내부조명에 미치는 영향에 관한 연구)

  • Lee, Mi-Ae;Lee, Dong-Hee
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.15 no.5
    • /
    • pp.497-504
    • /
    • 2013
  • This research uses numerical analysis to examine the tunnel portal landscape affecting the brightness level of interior lighting when designing lights for road tunnels through the L20 method. In order to extract the brightness recognition per form of a tunnel entrance and to evaluate the effects of the characteristics of the materials of facilities near a tunnel portal, brightness analysis was conducted by filming brightness on a video photometer called Hi-land Elf System, and a surface brightness photometer called LMK Mobile Advanced. Tunnels in Korea are mostly distributed in mountain areas; thus, the ratio occupied by the sky, which has the highest brightness within the angle of L20, is close to zero, while most of the ratio was occupied by brightness by the area near the tunnel entrance or road surface. However, for a tunnel portal retaing wall, which allows the width of a tunnel entrance to seem wider within the L20 angle, appeared to be have higher brightness compared to nearby areas or the surface, which is an element increasing the tunnel portal brightness within the tunnel, and the road facilities near the tunnel portal appeared to have an effect on the brightness as well. Thus, when designing tunnel lights based on brightness, the form of the tunnel entrance and the area width, material, and color of areas near the tunnel portal appeared to affect outside brightness and become an element affecting the establishment of the brightness level of the interior lights of tunnels. Consequently, reviewing such matters is a prerequisite when designing tunnel portal landscape.

Study on Statistical Method for Objective Evaluation of Tunnel Portal Slopes (객관적인 터널 갱구사면 평가를 위한 통계기법 연구)

  • Kwon, O-Il;Baek, Yong;Na, Jong-Hwa;Seo, Yong-Seok;Kim, Gyo-Won
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2006.03a
    • /
    • pp.634-643
    • /
    • 2006
  • This study was intended to develop a high reliable technique by statistically processing on-site data with a general linear model, providing the basic data for construction, analysis of stability and establishment of maintenance measures for tunnel portal slopes in the future. This study evaluated the stability of a tunnel portal slope using a quantified technique, which is based on a general linear model. The important scores of each independent variable were allocated by using the ranges of the quantified values, based on the predicted coefficient of regression and the scores for categories of each independent variable were allocated so that those are equally spaced. The quantification model obtained from the results of evaluating the total data used for the quantification process provided precise results. In addition, it is expected that a more detail subdivision of response variables and sufficient data would produce a better stability evaluation standard.

  • PDF

Development of 1/60th Scale Moving Model Rig Using the Compressed Air Launcher and One-Wire Guidance System of Train Model (압축공기 발사기에 단선 와이어 유도방식을 적용한 1/60축척 터널주행 열차모형 시험기 개발에 대한 연구)

  • Kim, Dong-Hyeon;O, Il-Geun
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.25 no.5
    • /
    • pp.634-644
    • /
    • 2001
  • The test facility of a 1/60-scale model for train-tunnel systems has been recently developed to investigate the effects of tunnel portal shapes, hood shapes and air-shafts for reducing the micro-pressure waves radiating towards the surroundings from the tunnel exit. The present test rig has been advanced from a 1/70-scale facility at NLR in Netherlands. The NLR test rig has the two-wise guidance system that needs two ears attached on the external surface of a model train nose. Therefore, their train models have irregular nose shapes. The main characteristics of the present facility are that the train model is guided by only one wire from the compressed air launcher to the absorber parts of test facility and the wire guidance hole is located at the axial center of a train model. In the present test rig, after a train model is launched, the air jet from the launcher does not enter the tunnel model. Experimental results were compared with numerical predictions to prove the performance of the test facility.

A Study on Noise Reduction of Railway Noise by Noise Barrier (방음 터널 설치에 따른 소음 저감 효과 연구)

  • Kim, Da rae;Kim, Tae min;Kim, Jeung Tae;Son, Jeung gon;Park, Gwang hyeon;Ryu, Raeeon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2014.10a
    • /
    • pp.125-130
    • /
    • 2014
  • High speed railroad car and high-rise apartment with development of railway technology cause different problems of noise contrary to the previous generation. It is the most efficient noise reduction countermeasure but we studied that is the way on noise propagation with sound proof wall or sound proof tunnel around railroad. But if it were railroad on bridge, additional cost which is more expensive than installing one on the ground is needed. So sound insulation material considering reducing weight of recent soundproof facilities must be selected. It is in this study that predicted and analyzed acoustical and structural effect for noise reduction by installing soundproof tunnel. If it were departmentalized into additional study, could be able to expect noise reduction effect of sound proof tunnel establishment on the bridge.

  • PDF

Suggestion of a Design Method for UAM (강관 다단 그라우팅 공법(UAM)의 설계법 제안)

  • 박이근;임종철
    • Journal of the Korean Geotechnical Society
    • /
    • v.20 no.3
    • /
    • pp.97-106
    • /
    • 2004
  • In case of tunnel construction with a shallow soil cover in cohesionless soils or highly weathered rocks, reinforcement measures are required for a tunnel stability during the tunnel construction. Recent developments show that the use of Umbrella Arch Method(UAM) as tunnel reinforcement and water cut-off in domestic projects has increased. Unfortunately, guidelines for the design and construction of UAM have not been established, only empirical designs and applications in tunnel construction have been performed so far. In this study, behaviour of the steel pipes installed on the tunnel roof was analyzed through the monitoring of bending and axial stresses of the pipes with the advance of the tunnel face. The monitoring results were used in the establishment of the loading mechanism around the pipe. This paper suggests, the guidelines used in the determination of the total length, overlapping length and lateral spacing of the reinforcing pipes obtained from the established loading mechanism.

Scenarios for Effective Fire Fighting Operations during Tunnel Fires (도로터널 화재시 효과적인 소방활동전략 수립을 위한 시나리오 연구)

  • Kim, Hak kuen;Lee, Ji-hee
    • Fire Science and Engineering
    • /
    • v.31 no.5
    • /
    • pp.107-116
    • /
    • 2017
  • Fires in tunnels are an international concern and fatal accidental fires in tunnels seem to occur on annual. They have the potential to become much worse int the future as more and longer tunnels are constructed and as traffic densities increase. This is a serious problem. The main purpose of this study is to develop operational procedures for fire brigades in road tunnel fires. This study discussed the past to see what can be learned from the incidents that have already done in tunnels. 73 cases of road tunnel fires domestic and outside of Korea were investigated and classified into 4 incident categories. Among them, 4 tunnel fires are highlighted, focusing on the activities of fire brigades and operation. Regarding the establishment of the strategies for fire fighting, 6 kinds of fire scenario curves have been deducted with regard to the relation between intervention time and heat release rate. It made the choice from the defensive or aggressive fire fighting activities depending on two criteria i.e. response limit and maximum response time. Road Tunnel Classification models can be useful when a fire brigade evaluates fire risk levels in the tunnels under its jurisdiction from the firefighting point of view and sets up preventive measures.