• Title/Summary/Keyword: tube internal

Search Result 586, Processing Time 0.027 seconds

The Confining Effect of Concrete by Internal Steel Tube (내부 삽입강관에 의한 콘크리트 구속효과 연구)

  • Kim Hong Jung;Han Taek Hee;Kang Young Jong;Jung Doo Suk
    • Proceedings of the KSR Conference
    • /
    • 2003.10b
    • /
    • pp.501-509
    • /
    • 2003
  • The confining effect of concrete was studied when a steel tube is set at the inside face of a hollow reinforced concrete column. To investigate the confining effect by a steel tube, 36 specimens were tested and compared. Test results show that the inserted steel tube provide sufficient confinement to the confining effect depends on the thickness of the steel tube. And also, test results show that the provided confinement by a steel tube increase the strength of concrete.

  • PDF

A Study on Optimum Confined Effect for Internally Confined Hollow CFT Columns under Uniaxial Compression (일축압축을 받는 내부 구속 중공 CFT 기둥의 최적 구속 효과 연구)

  • Won, Deok Hee;Han, Taek Hee;Yoon, Na Ri;Kang, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.32 no.4A
    • /
    • pp.227-235
    • /
    • 2012
  • Recently, study of confining effect in column members is progressed. But these studies are limited to about RC column and external confining effect in hollow columns. Internal confining effect in hollow columns has not researched. Internal confining stress is assumed the same external confining stress in hollow columns. In this study, there are to investigate the internal direction confining effect in ICH CFT column by FEA analysis. FEA analysis methods have verified by experimental values. Parametric study has performed as thickness of internal tube, hollow ratio, diameter of column and bending stiffness between concrete and external tube. Modified equations have suggested to estimating economic and reasonable thickness of internal tube.

Confining Effect of an Internal Steel Tube in a Circular Hollow RC Column (원형 강관 삽입 중공 RC 기둥의 내부구속 효과 연구)

  • Han, Taek Hee;Kim, Hong Jung;Kim, Young Jong;Kang, Young Jong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.26 no.4A
    • /
    • pp.565-575
    • /
    • 2006
  • When concrete is confined, its strength is enhanced by confining stress. Thus, increasing confining stress makes concrete strength higher. But a brittle failure may occur in hollow RC(Reinforced Concrete) column although its concrete is confined by transverse reinforcements. This brittle failure results from the absence of internal confinement and it decreases the strength and the ductility of a hollow RC column. To overcome this brittle failure problem, a hollow RC column which has a internal steel tube was developed. In this study, an experiment was performed to investigate the existence of to internal confinement by a settled steel tube. Thirty six specimens were tested and test results show the existence of internal confinement by the increase of concrete strength.

Experimental Study on Optimal Design of Internal Heat Exchanger for $CO_2$ System ($CO_2$ 시스템에서 내부열교환기 최적설계에 대한 실험적 연구)

  • Kim, Dae-Hoon;Lee, Sang-Jae;Choi, Jun-Young;Lee, Jae-Heon;Kwon, Young-Chul
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2085-2090
    • /
    • 2007
  • This paper describes the possible way to improve the capacity, the efficiency and the pressure drop of $CO_2$ system. It is considered the use of an internal heat exchanger (IHX) to improve the performance of the $CO_2$ system. Experiment was performed by changing a tube shape, a tube number and a tube length of IHX to investigate the performance of IHX for $CO_2$ system. The focus of the present study is to obtain the concept on IHX optimal design. Experimental results show that design parameters are closely related with the capacity and the pressure drop of $CO_2$ system. In the transcritical $CO_2$ cycle, the system performance is very sensitive to the IHX design. System performance on operation condition and shape of IHX is also introduced.

  • PDF

Experimental Studies on Formability and Characteristics of Tube Hydroforming (관재 액압성형에 의한 성형성 및 성형품 특성에 관한 실험적 연구)

  • Jo Y. J.;Son H. S.;Park C. D.;Kim Y. S.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2001.10a
    • /
    • pp.54-57
    • /
    • 2001
  • Hydroforming is core production techniques for the super light weight and high safety of the vehicle body. In order to establish and understand hydroforming, the tube hydroforming simulator which could control an axial compression and high internal pressure with computer operation was developed in tube bulging. This paper presents experimental investigation for process parameters, such as Internal pressure and axial compression. In addition, the mechanical properties, such as strain hardening and energy absorption ability of hydroformed part, is discussed.

  • PDF

The Long-term Follow-up Study of Therapeutic Effects of 8 French Catheter for Spontaneous Pneumothorax (자연 기흉의 치료에서 8 French 도관삽입의 치료 효과에 대한 장기적 관찰)

  • Shin, Jong-Wook;Lee, Byoung-Hoon;An, Chang-Hyeok;Choi, Jae-Sun;Yoo, Jee-Hoon;Lim, Seong-Yong;Kang, Yoon-Jung;Koh, Hyung-Ki;Kim, Jae-Yeol;Na, Moon-Jun;Park, In-Won;Sobn, Dong-Suep;Choi, Byoung-Whui;Hue, Sung-Ho
    • Tuberculosis and Respiratory Diseases
    • /
    • v.44 no.5
    • /
    • pp.1094-1104
    • /
    • 1997
  • Background : Spontaneous pneumothoraces(SP) are divided into primary spontaneous pneumothoraces (PSP) which develop in healthy individuals without underlying pulmonary disorders and secondary spontaneous pneumothoraces(SSP) which occur in those who have underlying disorders such as tuberculosis or chronic obstructive lung diseases. Yet there is no established standard therapeutic approach to this disorder, i.e., from the spectrum of noninvasive treatment such as clinical observation with or without oxygen therapy, to aggressively invasive thoracoscopic bullectomy or open thoracotomy. Although chest tube thoracostomy has been most widely used, the patients should overcome pain in the initiation of tube insertion or during indwelling it potential infection and subcutaneous emphysema. Thus smaller-caliber tube has been challenged for the treatment of pneumothorax. Previously, we studied the therapeutic efficacy of 8 French catheter for spontaneous pneumothorax. But there has been few data for effectiveness of small-caliber catheterization in comparison with that of chest tube. In this study, we intended to observe the long-term effectiveness of 8 French catheter for the treatment of spontaneous pneumothoraces in comparison with that of chest tube thoracostomy. Method : From January, 1990 to January, 1996, sixty two patients with spontaneous pneumothoraces treated at Chung-Ang University Hospital were reviewed retrospectively. The patients were sub-divided into a group treated with 8 French catheter(n=23) and the other one with chest tube insertion(n=39). The clinical data were reviewed(age, sex, underlying pulmonary disorders, past history of pneumothorax, size of pneumothorax, follow-up period). And therapeutic effect of two groups was compared by treatment duration(duration of indwelling catheter or tube), treatment-associated complications and recurrence rate. Results : The follow-up period(median) of 8 French catheter group and chest tube group was 28 and 22 months, which had no statistical significance. Ther was no statistically significant difference of clinical characteristics between two groups with SP, PSP, SSP. The indwelling time of 8 French catheter group was $6.2{\pm}3.8$ days, which was significantly shorter than that of chest tube group in SP, $9.1{\pm}7.5$ days(p=0.047). In comparison of treatment-related complication in PSP, 8 French catheter group as 6.25% of complication showed lower tendency than the other group as 23.8% (p=0.041 ; one-tailed, p=0.053; two-tailed). The recurrence rate in each group of SP was 17.4%, 10.3%, which did not show any statistically significant difference. Conclusion : Treatment with 8 French catheter resulted in shorter indwelling time in sponteous pneumothorax, and lower incidence of treatment-related complication in primary spontaneous pneumothorax. And the recurrence rate in each of treatment group showed no statistically significant difference. So, we can recommend the 8 French small-caliber catheter for the initial therapy for spontaneous pneumothorax for the replacement of conventional chest tube thoracostomy. But further prospective study with more subjects of spontaneous pneumothorax will be needed for the evaluation of effectiveness of 8 French cateter.

  • PDF

The Characteristics of a Superposed Discharge Type Ozonizer Using Vacuum Discharge Tube (진공 방전관을 이용한 고농도 중첩방전형 오존발생기의 특성)

  • Song, Hyun-Jig;Lee, Chang-Ho
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.5
    • /
    • pp.60-67
    • /
    • 2005
  • The superposed discharge type ozonizer of high ozone concentration using vacuum discharge tube has been designed and manufactured. It consists of three electrodes(central electrode, internal electrode, and external electrode) and one discharge gap(discharge gap between internal electrode and external electrode), is a superposed silent discharge type ozonizer for which the AC high voltages applied to the central electrode within discharge tube and the internal electrode has a $180{[^\circ]}$ phase difference and for which the external electrode is a ground. Ozone is generated by overlapping silent discharge between central electrode and external electrode, and silent discharge between internal electrode and external electrode. At the moment, discharge characteristics and ozone generation characteristics were investigated in accordance with vacuum of discharge tube, discharge power of ozonizer, and quantity of supplied oxygen gas. In consequence, high ozone concentration can be obtained 8840[ppm].

Evaluation of Endcap Welding Test for a Nuclear Fuel Rod having External and Internal Tube Structure (내외부 이중튜브구조를 갖는 핵연료봉의 봉단마개 용접시험 평가)

  • Kim, Soo-Sung;Kim, Jong-Hun;Kim, Hyung-Kyu
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.1377-1380
    • /
    • 2008
  • An irradiation test of a nuclear fuel rod having external and internal tube structure was planned for a performance. To establish fabrication process satisfying the requirements of irradiation test, micro-TIG welding system for fuel rods was developed, and preliminary welding experiments for optimizing process conditions of fuel rod was performed. Fuel rods with 15.9mm diameter and 0.57mm wall thickness of cladding tubes and end caps have been used and optimum conditions of endcap welding have been selected. In this experiment, the qualification test was performed by tensile tests, helium leak inspections, and metallography examinations to qualify the endcap welding procedure. The soundness of the welds quality of a dual cooled fuel rods has been confirmed by mechanical tests and microstructural examinations.

  • PDF

A Comparison of the Heat Transfer Performance of Thermosyphon Using a Straight Groove and a Helical Groove

  • Han Kyuil;Cho Dong-Hyun
    • Journal of Mechanical Science and Technology
    • /
    • v.19 no.12
    • /
    • pp.2296-2302
    • /
    • 2005
  • This study is focused on the comparison of heat transfer performance of two thermosyphons having 60 straight and helical internal grooves. Distilled water has been used as working fluid. Liquid fill charge ratio defined by the ratio of working fluid volume to total internal volume of thermosyphon, the inclination angle and operating temperature were used as experimental parameters. The heat flux and heat transfer coefficient are estimated from experimental results. The conclusions of this study may be summarized as follows; Liquid fill charge ratio, inclination angle and geometric shape of grooves were very important factors for the operation of thermosyphon. The optimum liquid fill charge ratio for the best heat flux were $30\%$. The heat transfer performance of helically grooved tube was higher than that of straight grooved tube in low inclination angle (less than $30^{\circ}$), but the results were opposite in high inclination angle (more than $30^{\circ}$). As far as optimum inclination angle concerns, range of $25^{\circ}\~30^{\circ}$ for a helically grooved tube and about $40^{\circ}$ for a straight grooved tube are suggested angles for the best results.

Application of the Runge Kutta Discontinuous Galerkin-Direct Ghost Fluid Method to internal explosion inside a water-filled tube

  • Park, Jinwon
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • v.11 no.1
    • /
    • pp.572-583
    • /
    • 2019
  • This paper aims to assess the applicability of the Runge Kutta Discontinuous Galerkin-Direct Ghost Fluid Method to the internal explosion inside a water-filled tube, which previously was studied by many researchers in separate works. Once the explosive charge located at the inner center of the water-filled tube explodes, the tube wall is subjected to an extremely high intensity fluid loading and deformed. The deformation causes a modification of the field of fluid flow in the region near the water-structure interface so that has substantial influence on the response of the structure. To connect the structure and the fluid, valid data exchanges along the interface are essential. Classical fluid structure interaction simulations usually employ a matched meshing scheme which discretizes the fluid and structure domains using a single mesh density. The computational cost of fluid structure interaction simulations is usually governed by the structure because the size of time step may be determined by the density of structure mesh. The finer mesh density, the better solution, but more expensive computational cost. To reduce such computational cost, a non-matched meshing scheme which allows for different mesh densities is employed. The coupled numerical approach of this paper has fewer difficulties in the implementation and computation, compared to gas dynamics based approach which requires complicated analytical manipulations. It can also be applied to wider compressible, inviscid fluid flow analyses often found in underwater explosion events.