• Title/Summary/Keyword: tube current

Search Result 925, Processing Time 0.029 seconds

Dosimetric Evaluation of a Small Intraoral X-ray Tube for Dental Imaging (치과용 초소형 X-선 튜브의 선량평가)

  • Ji, Yunseo;Kim, YeonWoo;Lee, Rena
    • Progress in Medical Physics
    • /
    • v.26 no.3
    • /
    • pp.160-167
    • /
    • 2015
  • Radiation exposure from medical diagnostic imaging procedures to patients is one of the most significant interests in diagnostic x-ray system. A miniature x-ray intraoral tube was developed for the first time in the world which can be inserted into the mouth for imaging. Dose evaluation should be carried out in order to utilize such an imaging device for clinical use. In this study, dose evaluation of the new x-ray unit was performed by 1) using a custom made in vivo Pig phantom, 2) determining exposure condition for the clinical use, and 3) measuring patient dose of the new system. On the basis of DRLs (Diagnostic Reference Level) recommended by KDFA (Korea Food & Drug Administration), the ESD (Entrance Skin Dose) and DAP (Dose Area Product) measurements for the new x-ray imaging device were designed and measured. The maximum voltage and current of the x-ray tubes used in this study were 55 kVp, and 300 mA. The active area of the detector was $72{\times}72mm$ with pixel size of $48{\mu}m$. To obtain the operating condition of the new system, pig jaw phantom images showing major tooth-associated tissues, such as clown, pulp cavity were acquired at 1 frame/sec. Changing the beam currents 20 to $80{\mu}A$, x-ray images of 50 frames were obtained for one beam current with optimum x-ray exposure setting. Pig jaw phantom images were acquired from two commercial x-ray imaging units and compared to the new x-ray device: CS 2100, Carestream Dental LLC and EXARO, HIOSSEN, Inc. Their exposure conditions were 60 kV, 7 mA, and 60 kV, 2 mA, respectively. Comparing the new x-ray device and conventional x-ray imaging units, images of the new x-ray device around teeth and their neighboring tissues turn out to be better in spite of its small x-ray field size. ESD of the new x-ray device was measured 1.369 mGy on the beam condition for the best image quality, 0.051 mAs, which is much less than DRLs recommended by IAEA (International Atomic Energy Agency) and KDFA, both. Its dose distribution in the x-ray field size was observed to be uniform with standard deviation of 5~10 %. DAP of the new x-ray device was $82.4mGy*cm^2$ less than DRL established by KDFA even though its x-ray field size was small. This study shows that the new x-ray imaging device offers better in image quality and lower radiation dose compared to the conventional intraoral units. In additions, methods and know-how for studies in x-ray features could be accumulated from this work.

Research of Protocols for Optimization of Exposure Dose in Abdominopelvic CT - (복부-골반 CT검사 시 피폭선량 최적화에 관한 프로토콜 연구)

  • Hong, Dong-Hee
    • Journal of radiological science and technology
    • /
    • v.40 no.2
    • /
    • pp.245-251
    • /
    • 2017
  • This study measured the exposure dose during abdominal-pelvic CT exam which occupies 70% of CT exam and tried to propose a protocol for optimized exposure dose in abdomen and pelvis without affecting the imagery interpretation. The study scanned abdomen-pelvis using the current clinical scan method, the 120 kVp, auto exposure control(AEC), as 1 phase. As for the newly proposed 2 phase scan method, the study divided into 1 phase abdomen exam and 2 phase pelvis exam and each conducted tube voltage 120 kVp, AEC for abdomen exam, and fixed tube current method in 120 kVp, 100, 150, 200, 250, 300, 350, 400 mA for pelvis exam. The exposure dose value was compared using $CTDI_{VOL}$, DLP value measured during scan, and average value of CT attenuation coefficient, noise, SNR from each scan image were obtained to evaluate the image. As for the result, scanning of 2 phase showed significant difference compared to 1 phase. In $CTDI_{VOL}$ value, the 2 phase showed 26% decrease in abdomen, 1.8~59.5% decrease in pelvis for 100~250 mA, 12.7%~30% increase in pelvis for 300~400 mA. Also, DLP value showed 53% decrease in abdomen and 41~81% decrease in pelvis when scanned by 2 phase compared to 1 phase, but it was not statistically significant. As for the SNR, when scanning 2 phase close to heart, scanning 1 phase close to pelvis, scanning and scanning 1 phase at upper and lower abdomen, it was higher when scanning 2 phase for 200~250 mA. Also, the CT number and noise was overall similar, but the noise was high close to pelvis. However, when scanning 2 phase for 250 mA close to pelvis, the noise value came out similar to 1 phase, and did not show statistically significant difference. It seems when separating pelvis to scan in 250 mA rather than 400 mA in 1 phase as before, it is expected to have reduced effect of exposure dose without difference in the quality of image. Thus, for patients who often get abdominal-pelvic CT exam, fertile women or children, this study proposes 2 phase exam for smaller exposure dose with same image quality.

A Study on the Optimum Design for Preventing Propelling Charge to Military Ammunition Vehicle (탄약운반장갑차의 장약 파손 방지를 위한 최적설계에 관한 연구)

  • Noh, Sang Wan;Kim, Sung Hoon;Park, Young Min;Kim, Byung Hyun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.11
    • /
    • pp.494-500
    • /
    • 2019
  • The purpose of this study was to determine a method to prevent damage during the transfer of loading through optimal design of loading transfer software for an ammunition-carrying armored vehicle. Typically, an ammunition carrier armored car is equipped with an automated charge transfer system. The load is intermittently damaged during the loading of the cargo, and this needs to be improved. The following improvements and verification tests were carried out. As impact speed increased, the loading speed was reduced 60%, and a special fixture utilizing a force gauge was developed and tested. If the maximum current of 11A for the servo controller is output when the load of the conveyor is generated by interference inside the loading tube, there is a possibility of charge breakage. If the maximum current is low, the load cannot be loaded. In the loading test for the ammunition carrier armored car with the actual charge, the improved design was found to be valid, as the load was not damaged and occurred nominally.

Effects of Sintering Temperature and SiC Contents on the Microstructure and Superconducting Properties of In-situ $MgB_2$ Wires (In-situ $MgB_2$ 선재의 소결온도와 SiC 함량에 따른 미세조직 및 초전도 특성 연구)

  • Hwang, Soo-Min;Park, Eui-Cheol;Park, Si-Hong;Jang, Seok-Hern;Kim, Kyu-Tae;Lim, Jun-Hyung;Joo, Jin-Ho;Kang, Won-Nam;Kim, Chan-Joong
    • Progress in Superconductivity
    • /
    • v.9 no.1
    • /
    • pp.68-73
    • /
    • 2007
  • We fabricated the in-situ $MgB_2$ wires using the powder-in-tube method and investigated the effects of sintering temperature and SiC contents on the microstructure and superconducting properties. Pure $MgB_2$ wires and 5, 10, 20 wt.% SiC doped $MgB_2$ wires were sintered at $600-1000^{\circ}C$ for 30 minutes in Ar atmosphere. We found that $MgB_2$ phase was mostly formed at the sintering temperature of $700^{\circ}C$ and above, and the critical temperature ($T_c$) increased with increasing sintering temperature. For the $MgB_2$ sintered at $850^{\circ}C$, the highest critical current density ($J_c$) was obtained to be $3.7{\times}10^5\;A/cm^2$ at 5 K and 1.6 T by a magnetic properties measurement system (MPMS). The addition of SiC to the $MgB_2$ wires changed microstructure and critical properties. SEM observation showed that the $MgB_2$ core had considerable micro-cracks in undoped wire and the density of micro-cracks decreased with increasing SiC contents. The critical temperature decreased as the SiC contents increased, on the other hand, the critical current density of SiC doped $MgB_2$ wires in high magnetic field was enhanced compared to that of undoped $MgB_2$ wires.

  • PDF

Electrorefining Behavior of Zirconium Scrap with Multiple Cathode in Fluoride-Based Molten Salt (불화물계 용융염을 이용한 지르코늄 스크랩의 다중전극 전해정련 거동)

  • Park, Dong Jae;Kim, Seung Hyun;Park, Kyoung Tae;Mun, Jong Han;Lee, Hyuk Hee;Lee, Jong Hyeon
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.13 no.1
    • /
    • pp.11-19
    • /
    • 2015
  • The production of nuclear fuel cladding tube is expected to increase with the nuclear power plant expansion. Zirconium(Zr) scrap that is generated during manufacturing is also expected to increase. Zr electrorefining experiment was carried out in the fluoride salt of LiF-KF-ZrF4 using multiple electrode for scale up and improving throughput Zr electrorefiner develop-ment. The Zr reduction peak observed at-0.8 V(vs.Ni). Polarization behavior showed that the amount of applied current increases because of decreasing cell resistance as the number of cathode increases. Experimental results showed the highest recovery rate about 98% at lowest current density of 25.64 mA/cm2 using 6 electrodes. XRD and TG analysis result show that pure Zr was recovered 99.92% and ICP analysis shows that lower impurity content than conventional impurity content of the Anode(97.8%). Electrorefining consumes energy about 7.15 kWh/kg less than 39.7% compared to the Kroll process using 6 electrode width of 20 mm and height of 65 mm. Because of increasing cell efficiency and recovery rate, using multiple cathode is determined as an efficient technique for scale up electrorefining Zr scrap.

The Effect of Transverse Magnetic field on Macrosegregation in vertical Bridgman Crystal Growth of Te doped InSb

  • Lee, Geun-Hee;Lee, Zin-Hyoung
    • Proceedings of the Korea Association of Crystal Growth Conference
    • /
    • 1996.06a
    • /
    • pp.522-522
    • /
    • 1996
  • An investigation of the effects of transverse magnetic field and Peltier effect on melt convection and macrosegregation in vertical Bridgman crystal grosth of Te doped InSb was been carried out by means of microstructure observation, Hall measurement, electrical resistivity measurement and X-ray analysis. Before the experiments, Interface stability, convective instability and suppression of convection by magnetic field were calculated theoretically. After doping 1018, 1019 cm-3 Te in InSb, the temperature of Bridgman furnace was set up at $650^{\circ}C$. The samples were grown in I.D. 11mm, 100mm high quartz tube. The velocity of growth was about 2${\mu}{\textrm}{m}$/sec. In order to obtain the suppression of convection by magnetic field in the middle of growth, 2-4KG magnetic field was set on the melt. For searching of the shape of solid-liquid interface and the actual velocity of crystal growth, let 2A current flow from solid to liquid for 1second every 50seconds repeatedly (Peltier effect). The grown InSb was polycrystal, and each grain was very sharp. There was no much difference between the sample with and without magnetic field at a point of view of microstructure. For the sample with Peltier effect, the Peltier marks(striation) were observed regularly as expected. Through these marks, it was found that the solid-liquid interface was flat and the actual growth velocity was about 1-2${\mu}{\textrm}{m}$/sec. On the ground of theoretical calculation, there is thermosolutal convection in the Te doped InSb melt without magnetic field in this growth condition. and if there is more than 1KG magnetic field, the convection is suppressed. Through this experiments, the effective distribution coefficients, koff, were 0.35 in the case of no magnetic field, and 0.45 when the magnetic field is 2KG, 0.7 at 4KG. It was found that the more magnetic field was applied, the more convection was suppressed. But there was some difference between the theoretical calculation and the experiment, the cause of the difference was thought due to the use of some approximated values in theoretical calculation. In addition to these results, the sample with Peltier effect showed unexpected result about the Te distribution in InSb. It looked like no convection and no macrosegregation. It was thought that the unexpected behavior was due to Peltier mark. that is, when the strong current flew the growing sample, the mark was formed by catching Te. As a result of the phenomena, the more Te containing thin layer was made. The layer ruled the Hall measurement. The values of resistivity and mobility of these samples were just a little than those of other reference. It was thought that the reason of this result was that these samples were due to polycrystal, that is, grain boundaries had an influence on this result.

  • PDF

Estimation of Home Care Nursing Cost to the Patient with Cerebrovascular Disease based on a Bundle of Home Care Nursing Service (뇌혈관질환 환자군의 가정간호 행위묶음 수가연구)

  • Hong, Jin-Ui;Yun, Soon-Nyoung
    • Journal of Home Health Care Nursing
    • /
    • v.7 no.1
    • /
    • pp.26-38
    • /
    • 2000
  • The purpose of this study was to estimate home care nursing cost for the patient with Cerebrovascular Disease based on a bundle of home care nursing services This study was conducted through four steps. The first step was to investigate home care nursing activities that were offered to the patient with Cerebrovascular Disease(CD) by home care nurse. The second step was to investigate the time spent on home care nursing service and to calculate labor and manufacturing cost. The third step was to calculate home care nursing cost per minute. And at the fourth step, home care nursing cost for a patient with Cerebrovascular Disease based on a bundle of home care nursing service was calculated. The results of the study were as follows: 1) The number of direct home care nursing activities for the patient with CD was 108, and the time of each activity was spent from 1 to 10 minutes. 2) Average time per visit was 51 minute, and the firs visit time were spent 1.6 times higher than 2nd visit time. 3) Nursing cost per minute(cost per visit ${\\}\;22,565\;\div\;$ average time per visit 51 minutes) was ${\\}\;442$. The cost per visit was calculated on Basic visiting cost(nurse's labor cost ${\\}\;15,760$ + management cost ${\\}\;6,805$) divided by average time per visit(51 minutes). 4) Home care nursing cost to the patient with CD based on bundle of home care nursing service was consisted of basic home care nursing cost, the cost of a bundle of service practiced on visit. and transportation fee. Basic home nursing cost(the time spent on basic home nursing service 20 minutes ${\times}$ nursing cost per minute ${\\}\;442$) was ${\\}\;8,840$. The cost of the bundle of home care nursing services to the patient with CD was calculated as self care ${\\}\;2.898$, Tracheostomy care ${\\}\;10,166$, immobility care ${\\}\;6,188$, sore care ${\\}\;6,188$. Foley care ${\\}\;6,630$, and Levin tube or Gastrostomy care ${\\}\;7.514$. Transportation fee which was composed of the labor cost for transportation(${\\}\;5,122$) and the car management cost(${\\}\;3.876$) was ${\\}\;8,998$. Home care nursing cost to the patient with CD based on bundle of home care nursing services consisted of basic home care nursing cost, the cost of a bundle of service practiced on visit, and transportation fee. It will contribute to improve quality of home care service, because of giving appreciate incentives to home care nurses. And it will be more efficient than current cost of hospital based home care. But it need to management than calculation of the current fee-for-services of home care.

  • PDF

Growth of $CdS_{0.67}Se_{0.33}$ single crystal by sublimation method and their photoconductive characteristics (승화법에 의한 $CdS_{0.67}Se_{0.33}$ 단결정 성장과 광전도 특성)

  • Hong, K.J.;Lee, S.Y.
    • Journal of Sensor Science and Technology
    • /
    • v.7 no.2
    • /
    • pp.131-139
    • /
    • 1998
  • $CdS_{0.67}Se_{0.33}$ single crystal was grown by vertical sublimation method of closed tube physical vapour deposition. The (0001) growth plane of oriented single crystals was confirmed from the back-ref1ection Laue patterns. From the Hall effects by van der Pauw method, the as-grown $CdS_{0.67}Se_{0.33}$ single crystals were found to be n-type semiconductors. The mobility appeared to be decreased by lattice scattering at temperature range from 150K to 293K and by impurity scattering at temperatures ranging from 30K to 150K In order to explore its applicability in photoconductive cells, we measured the ratio of photo-current to dark-current (pc/dc), maximum allowable power dissipation (MAPD), spectral response and response time respectively. The results indicated that for the samples annealed in Cu vapour the photoconductive characteristics are best. We obtained sensitivity of 0.99, the value of pc/de of $1.84{\times}10^{7}$, the MAPD of 323mW and the rise and decay time of 9.3 ms and 9.7 ms, respectively.

  • PDF

Sol-gel deposited TiInO thin-films transistor with Ti effect

  • Kim, Jung-Hye;Son, Dae-Ho;Kim, Dae-Hwan;Kang, Jin-Kyu;Ha, Ki-Ryong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.200-200
    • /
    • 2010
  • In recent times, metal oxide semiconductors thin films transistor (TFT), such as zinc and indium based oxide TFTs, have attracted considerable attention because of their several advantageous electrical and optical properties. There are many deposition methods for fabrication of ZnO-based materials such as chemical vapor deposition, RF/DC sputtering and pulsed laser deposition. However, these vacuum process require expensive equipment and result in high manufacturing costs. Also, the methods is difficult to fabricate various multicomponent oxide semiconductor. Recently, several groups report solution processed metal oxide TFTs for low cost and non vacuum process. In this study, we have newly developed solution-processed TFTs based on Ti-related multi-component transparent oxide, i. e., InTiO as the active layer. We propose new multicomponent oxide, Titanium indium oxide(TiInO), to fabricate the high performance TFT through the sol-gel method. We investigated the influence of relative compositions of Ti on the electrical properties. Indium nitrate hydrate [$In(NO^3).xH_2O$] and Titanium isobutoxide [$C_{16}H_{36}O_4Ti$] were dissolved in acetylacetone. Then monoethanolamine (MEA) and acetic acid ($CH_3COOH$) were added to the solution. The molar concentration of indium was kept as 0.1 mol concentration and the amount of Ti was varied according to weighting percent (0, 5, 10%). The complex solutions become clear and homogeneous after stirring for 24 hours. Heavily boron (p+) doped Si wafer with 100nm thermally grown $SiO_2$ serve as the gate and gate dielectric of the TFT, respectively. TiInO thin films were deposited using the sol-gel solution by the spin-coating method. After coating, the films annealed in a tube furnace at $500^{\circ}C$ for 1hour under oxygen ambient. The 5% Ti-doped InO TFT had a field-effect mobility $1.15cm^2/V{\cdot}S$, a threshold voltage of 4.73 V, an on/off current ratio grater than $10^7$, and a subthreshold slop of 0.49 V/dec. The 10% Ti-doped InO TFT had a field-effect mobility $1.03\;cm^2/V{\cdot}S$, a threshold voltage of 1.87 V, an on/off current ration grater than $10^7$, and a subthreshold slop of 0.67 V/dec.

  • PDF

Current Status and Technologies for Treating Groundwater Arsenic Pollution in Bangladesh (방글라데시 지하수 내 비소 오염 현황 및 처리기술)

  • Tashdedul, Haque Md;Reyes, Nash Jett DG.;Jeon, Minsu;Kim, Lee-Hyung
    • Journal of Wetlands Research
    • /
    • v.24 no.2
    • /
    • pp.142-154
    • /
    • 2022
  • Arsenic (As) contamination in groundwater is one of the main problems in Bangladesh. As toxicity causes serious human health problems such as edema, skin cancer, bladder cancer, lung cancer, hyperkeratosis, premature birth, and black foot disease. As contamination in groundwater mainly originates from the geological characteristics of the area due to the influence of anthropogenic activities. Since most of the people in Bangladesh rely on tube well for drinking water, it is necessary to investigate the current status of As pollution and identify the treatment technologies that can be used to provide arsenic-free drinking water in water-scarce areas. A total of 92 papers were reviewed in this study to present a complete overview of the recent status of groundwater As contamination in Bangladesh and different low-cost remediation technologies. A method for evaluating the relative feasibility of different treatment technologies was also utilized to determine the most appropriate technologies for groundwater As treatment in Bangladesh. The districts with the highest groundwater As contamination include Brahamanbariya, Tangail, Barisal, Pabna, Patuakhali, Kurigram, Magura, and Faridpur, with concentrations exceeding 0.05 mg/L. Only six districts had relatively low groundwater arsenic concentrations (0.01 mg/L), including Kushtia, Khagrachari, Jessore, Dinajpur, Meherpur, and Munshiganj. There were a number of technologies used for treating As in water, but aerated electrocoagulation, Mg-Fe-based hydrotalcite-like compound, and electro-chemical As remediation (ECAR) reactor were found to be the most feasible treatment methods for As. Overall, the investment, operational, and maintenance costs, availability of materials, and expertise requirements should be considered when selecting the most appropriate treatment method for As in water.