• Title/Summary/Keyword: triple-error correction

Search Result 13, Processing Time 0.018 seconds

Efficient Use of Unused Spare Columns for Reducing Memory Miscorrections

  • Jung, Ji-Hun;Ishaq, Umair;Song, Jae-Hoon;Park, Sung-Ju
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.12 no.3
    • /
    • pp.331-340
    • /
    • 2012
  • In the deep sub-micron ICs, growing amounts of on-die memory and scaling effects make embedded memories increasingly vulnerable to reliability and yield problems. Spare columns are often included in memories to repair defective cells or bit lines during production test. In many cases, the repair process will not use all spare columns. Schemes have been proposed to exploit these unused spare columns to store additional check bits which can be used to reduce the miscorrection probability for triple errors in single error correction-double error detection (SEC-DED). These additional check bits increase the dimensions of the parity check matrix (H-matrix) requiring extra area overhead. A method is proposed in this paper to efficiently fill the extra rows of the H-matrix on the basis of similarity of logic between the other rows. Optimization of the whole H-matrix is accomplished through logic sharing within a feasible operating time resulting in reduced area overhead. A detailed implementation using fuse technology is also proposed in this paper.

Verification of Indicator Rotation Correction Function of a Treatment Planning Program for Stereotactic Radiosurgery (방사선수술치료계획 프로그램의 지시자 회전 오차 교정 기능 점검)

  • Chung, Hyun-Tai;Lee, Re-Na
    • Journal of Radiation Protection and Research
    • /
    • v.33 no.2
    • /
    • pp.47-51
    • /
    • 2008
  • Objective: This study analyzed errors due to rotation or tilt of the magnetic resonance (MR) imaging indicator during image acquisition for a stereotactic radiosurgery. The error correction procedure of a commercially available stereotactic neurosurgery treatment planning program has been verified. Materials and Methods: Software virtual phantoms were built with stereotactic images generated by a commercial programming language, Interactive Data Language (version 5.5). The thickness of an image slice was 0.5 mm, pixel size was $0.5{\times}0.5mm$, field of view was 256 mm, and image resolution was $512{\times}512$. The images were generated under the DICOM 3.0 standard in order to be used with Leksell GammaPlan$^{(R)}$. For the verification of the rotation error correction function of Leksell GammaPlan$^{(R)}$, 45 measurement points were arranged in five axial planes. On each axial plane, there were nine measurement points along a square of length 100 mm. The center of the square was located on the z-axis and a measurement point was on the z-axis, too. Five axial planes were placed at z=-50.0, -30.0, 0.0, 30.0, 50.0 mm, respectively. The virtual phantom was rotated by $3^{\circ}$ around one of x, y, and z-axis. It was also rotated by $3^{\circ}$ around two axes of x, y, and z-axis, and rotated by $3^{\circ}$ along all three axes. The errors in the position of rotated measurement points were measured with Leksell GammaPlan$^{(R)}$ and the correction function was verified. Results: The image registration errors of the virtual phantom images was $0.1{\pm}0.1mm$ and it was within the requirement of stereotactic images. The maximum theoretical errors in position of measurement points were 2.6 mm for a rotation around one axis, 3.7 mm for a rotation around two axes, and 4.5 mm for a rotation around three axes. The measured errors in position was $0.1{\pm}0.1mm$ for a rotation around single axis, $0.2{\pm}0.2mm$ for double and triple axes. These small errors verified that the rotation error correction function of Leksell GammaPlan$^{(R)}$ is working fine. Conclusion: A virtual phantom was built to verify software functions of stereotactic neurosurgery treatment planning program. The error correction function of a commercial treatment planning program worked within nominal error range. The virtual phantom of this study can be applied in many other fields to verify various functions of treatment planning programs.

A Study on the Design and Implementation of a DSSS-based MODEM for a Right Termination System(FTS) (대역확산방식 비행종단시스템의 모뎀설계와 구현에 관한 연구)

  • Lim Keumsang;Kim Jaehwan;Cho Hyangduck;Kim Wooshik
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.2C
    • /
    • pp.175-183
    • /
    • 2006
  • This letter proposes a Direct Sequence Spread Spectrum (DS-SS)-based Flight Termination System(FTS) and show the simulation results and implements the system using FRGAs. The DS-SS FTS has immunity interference signals and the influence of jamming signal. Moreover, a DS-SS FTS can provides effects on an authentication and encryption with spread codes. And the system uses more less power than an analog FM system. We used Reed-Solomon (32, 28) code and triple Data Encryption Standard(3DES) for error correction and data encryption. Also we used counter algorithm for unauthenticated device's attack The spread codes of In-phase channel and Quadrature channel were generated by Gold sequence generators. The system was implemented in Altera APEX20K100E FPGA for the ground system and EPF10K100ARC240-3 for the airborne system.