• Title/Summary/Keyword: triple difference

Search Result 147, Processing Time 0.032 seconds

Ratio and Rate of Induced Root Growth in Necrotic Immature Teeth (재생근관치료로 유도된 미성숙 치근 성장의 속도와 비율)

  • Sang, Eun Jung;Song, Ji-Soo;Shin, Teo Jeon;Kim, Young-Jae;Kim, Jung-Wook;Jang, Ki-Taeg;Lee, Sang-Hoon;Hyun, Hong-Keun
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.45 no.2
    • /
    • pp.225-234
    • /
    • 2018
  • The purpose of this study was to analyze the ratio and rate of apical closure when inducing root growth of necrotic immature permanent teeth using alternative triple antibiotics. 24 permanent teeth in the treatment group and 27 premolars in the control group were retrospectively studied using periapical radiographs for more than 300 days after the first visit. The difference in the growth rate between the two groups was statistically compared using the Mann-Whitney test at a significance level of 0.05. There were no statistically significant differences between the two groups in the first month and during months 1 - 3, 3 - 6, and 6 - 12. After 12 months, the cumulative rate of decrease in the apical foramen width in the treatment group was 50.59% and that in the control group was 71.82%, which revealed a significant difference between the two groups. There were significant differences in the rates of decrease in the apical foramen width after 3, 6 months, and later period in the treatment group, respectively. The cumulative rate of increase in the root dentin area presented no statistically significant differences between the treatment group and control group during the entire period of examination.

Global Value Chain and Misallocation: Evidence from South Korea

  • Bongseok Choi;Seon Tae Kim
    • Journal of Korea Trade
    • /
    • v.26 no.4
    • /
    • pp.1-22
    • /
    • 2022
  • Purpose - This paper empirically investigates the effect of a rise in the global value chain (GVC) on the industry-level efficiency of resource allocation (based on plant-level inefficiency measures) in Korea, with a focus on various channels through which a rise in the GVC can increase competition among firms and thus induce resources to be allocated more efficiently across firms. Design/methodology - We empirically investigate the relationship between the industry-specific importance of GVC and the industry-level allocative inefficiency that is measured as the dispersion of the plant-level marginal revenue of capital (MRK) as in Hsieh and Klenow's (2009) influential model. We compute MRK dispersion for industries sorted by various characteristics that are closely related to firm/industry sensitivity to the GVC. In other words, we compute the average industry-level MRK dispersion for industries sorted by industry-specific importance of GVC and compute the difference between the two groups of industries (higher vs. lower than the median GVC); we also calculate the difference between industries sorted by industry-specific export (import) intensity. This is our difference-in-difference estimate of the MRK dispersion associated with the GVC for the export (import)-intensive industry versus the non-export (non-import)-intensive industry. This difference-in-difference estimate of the MRK dispersion conditional vs. unconditional on firm-level productivity is then calculated further (triple-difference estimate). Findings - A rise in GVC is associated with a decrease in the MRK dispersion in the export-intensive industry compared to the non-export-intensive industry. The same is true for industries that rely heavily on imports versus those that do not (i.e., import intensive vs. non-intensive). Furthermore, the reduction in the MRK dispersion in the export-intensive industry associated with an increase in the GVC is disproportionately greater for high-productivity firms. In contrast, the negative relationship between GVC and MRK dispersion in the import-intensive industry is disproportionately smaller for high-productivity firms. Originality/value - Existing studies focus on the relationship between GVC and aggregate output, exports, and imports at the country level. We investigate detailed firm/industry-level mechanisms that determine the relationship between GVC, trade, and productivity. Using the plant-level data in South Korea, we investigate how GVC is related to the cross-firm MRK dispersion, an important measure of allocative inefficiency, based on Hsieh and Klenow's (2009) influential economic theory. This is the first study to provide plant-level evidence of how GVC affects MRK dispersion. Furthermore, we examine how the relationship between GVC and MRK-dispersion varies across export intensity, import intensity, and firm-level productivity, providing insight into how GVC can affect firms' exposure to competition in the global market differently depending on market conditions and thus generate trade-related productivity gains.

Evaluation of Image Quality Using CT Attenuation Correction in SPECT/CT (SPECT/CT에서 CT감쇠보정에 따른 영상의 질 평가)

  • Cho, Sung Wook;Kim, Gye Hwan;Sung, Yong Joon;Lee, Hyung Jin;Kim, Jin Eui
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.78-83
    • /
    • 2013
  • Purpose: SPECT/CT, a combination of SPECT and CT, is capable of expressing the results of attenuation correction on images biased by automatic program. As a result, this research evaluates the usefulness of images with CT attenuation correction, using various phantoms and images of patients. Materials and Methods: From July of 2012 to September of 2012, this research was conducted on the contrast, spatial resolution, and images of patients. We studied the contrast with IEC body phantom and Jaszczak phantom, while the spatial resolution was evaluated with NEMA triple line phantom. Further, a comparative study was carried out on the quality of the images, on the difference between the images before and after the CT attenuation correction. Results: Compared the differences between the contrast before and after the CT attenuation correction in IEC body phantom. The contrast was improved by 33.6% at minimum, 89.8% at maximum. In case of Jaszczak Phantom, the contrast was enhanced by 9.9% at minimum, 27.8% at maximum. In NEMA Triple line phantom, the resolution was raised by 4.5% in average: 4.4% in horizontal, 4.5% in vertical. In Anthropomorphic Torso Phantom, the perfusion score of the interior wall with the most severe attenuation was measured to be 29.4%. In the experiment carried out on myocardial perfusion SPECT/CT patients, 9% improvement was discovered in the interior wall, where the most dramatic attenuation occurred, after the CT attenuation correction. Conclusion: SPECT/CT proved its clinical usefulness by enabling the acquisition of images with enhanced contrast and spatial resolution compare to the ones resulted from SPECT.

  • PDF

Clinical Significance of Basal-like Breast Cancer in Chinese Women in Heilongjiang Province

  • Liu, Ying;Jiang, Qiu-Ying;Xin, Tao;Cai, Li;Zhao, Chang-Hong
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.6
    • /
    • pp.2735-2738
    • /
    • 2012
  • Background: Our objective was to clarify the clinical and biological characteristics of basal-like breast cancer (BLBC) and non-basal-like breast cancer (TN3BKE) in Heilongjiang. Methods: We examined, by immunohistochemistry, expression of biological markers cytokeratin (CK) 5/6 and epidermal growth factor receptor (EGFR) and B cell specific moloney murine leukemia virus integration site 1( Bmi-1) in triple-negative breast cancer (TNBC). We studied the correlation between BLBC and several factors related to tumor progression, along with its prognostic value. Results: In the 229 cases of operable TNBC, BLBC was detected in 178 (77.7%) and TN3BKE- in 51 (22.2%). There was no significant difference in clinicopathological factors between them, However, BLBC was significantly associated with Bmi-1 expression (P=0.000) and shorter disease-free survival (DFS) (P = 0.045) and overall survival (OS) (P = 0.041). Conclusions: Compared with the non-basal group, patients with BLBC have a high expression of Bmi-1 and a poor prognosis.

A Study on the Injection Characteristics of a Piezo Injector for Controlling Accurate Multiple Injection (커먼레일 타입 피에조 인젝터의 정밀 다단분사 제어를 위한 분사특성 연구)

  • Park, Heebum;Kim, Hyungik;Park, Sangki;Lee, Kihyung
    • Journal of ILASS-Korea
    • /
    • v.18 no.4
    • /
    • pp.176-181
    • /
    • 2013
  • In this study, injection quantity, rate and spray image of multiple injections which are important design parameters for a piezo type injector have been investigated. Interval of injections and a number of injections in multiple injection strategy has been controlled to verify interaction of each injection. Spray characteristics of multiple injections have been researched through optical process with a high speed camera in a high pressure chamber. In addition, a method of RMS(Root Mean Square) process has been used for comprehending the distribution of injection easily. As a result, in case of piezo type injector, characteristics of injection quantity according to charging voltage and the difference of injection quantity between single and triple injection were confirmed. Also, injection rate for increasing injection duration was confirmed. And spray characteristics of multiple injections were improved; multiple injections were possible in a shorter time interval between each injection. With this study, a possibilities of more accurate multiple injection control would be expected.

Numerical studies on cavitation behavior in impeller of centrifugal pump with different blade profiles

  • Song, Pengfei;Zhang, Yongxue;Xu, Cong;Zhou, Xin;Zhang, Jinya
    • International Journal of Fluid Machinery and Systems
    • /
    • v.8 no.2
    • /
    • pp.94-101
    • /
    • 2015
  • To investigate the influence of blade profiles on cavitation behavior in impeller of centrifugal pump, a centrifugal pump with five different blade profiles impellers are studied numerically. The impellers with five different blade profiles (single arc, double arcs, triple arcs, logarithmic spiral and linear-variable angle spiral) were designed by the in-house hydraulic design code using geometric parameters of IS 150-125-125 centrifugal pump. The experiments of the centrifugal pump have been conducted to verify numerical simulation model. The numerical results show that the blade profile lines has a weak effect on cavitation inception near blade inlet edge position, however it has the key effect on the development of sheet cavitation in impeller, and also influences the distribution of sheet cavitation in impeller channels. A slight changing of blade setting angle will induce significant difference of cavitation in impeller. The sharp changing of impeller blade setting angle causes obvious cavitation region separation near the impeller inlet close to blade suction surface and much more flow loss. The centrifugal pump with blade profile of setting angle gently changing (logarithmic spiral) has the super cavitation performance, which means smaller critical cavitation number and lower vapor cavity volume fraction at the same conditions.

Improvement of Mchanical Property of Indium-tin-oxide Films on Polymer Substrates by using Organic Buffer Layer

  • Park, Sung-Kyu;Han, Jeong-In;Moon, Dae-Gyu;Kim, Won-Keun
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.2
    • /
    • pp.32-37
    • /
    • 2002
  • This paper gives the basic mechanical properties of indium-tin-oxide (ITO) films on polymer substrates which are exposed to externally and thermally induced bending force. By using modified Storney formula including triple layer structure and bulge test measuring the conductive changes of patterned ITO islands as a function of bending curvature, the mechanical stability of ITO films on polymer substrates was intensively investigated. The numerical analyses and experimental results show thermally and externally induced mechanical stresses in the films are responsible for the difference of thermal expansion between the ITO film and the substrate, and leer substrate material and its thickness, respectively. Therefore, a gradually ramped heating process and an organic buffer layer were employed to improve the mechanical stability, and then, the effects of the buffer layer were also quantified in terms of conductivity-strain variations. As a result, it is uncovered that a buffer layer is also a critical factor determining the magnitude of mechanical stress and the layer with the Young's modulus lower than a specific value can contribute to relieving the mechanical stress of the films.

A Performance Assessment of Real-time Multichannel Audio Codec

  • Kim, Sunghan;Jang, Daeyoung;Hong, Jinwoo
    • The Journal of the Acoustical Society of Korea
    • /
    • v.16 no.3E
    • /
    • pp.56-61
    • /
    • 1997
  • In this paper, we describe a real-time implementation of a multi-channel auido codec system that is based on the MPEG-1 audio algorithm. The major feature of this system is that it has a flexible multi-DSP system that can be adapted for various applications with using up to four TMS320C40 DSPs. The purpose of this paper is to present the problems of the system and is to describe the optimized methods to solve the problems in the view of hardware and software. Our audio codec is composed of an encoder an a decoder system and the bit rate of bitstream is up to 384 kbps. Fast input/output interfaces, DSP overloads, and inter-DSP communications methods with high speed are considered in multi-DSP H/W. Also, to run real-time in S/W, optimizing methods of algorithm are considered. After implementation of system, the subjective assessment method, and 'triple stimulus/hidden reference/double blind' that recommended by ITU-R TG10/3 is adopted for the quality of our system. All test items except one are awarded difference grades(diffgrade) better than 1-. Form the results, multi-channel audio system can be used for HDTV service.

  • PDF

The survey on foot health of a primary school child (초등학교 5학년 어린이의 족부 건강에 대한 조사 연구)

  • Lim, Ho-Yong;Lim, Jin-Taek
    • Journal of Korean Physical Therapy Science
    • /
    • v.12 no.3
    • /
    • pp.35-45
    • /
    • 2005
  • The purpose of this study was to measure the static foot pressure distribution of children between forefoot and rearfoot, and the percentage of static pressure were measured from 1256 normal children in a primary school by the TPScan(Triple Pod Scan) systemCommercial system). The measurement were performed while standing with their comfortable state using the TPScan system. The static pressure distribution between forefoot and rearfoot was analyzed by paired t-test. The results were as follows: 1. The Pes cavus and Pes planus of students was 4.936%. 2. The Pes cavus were 42 children(3.343%) and Pes planus was 20 children(1.592%). 3. The Pes planus were seen in 42 of 1256 children with Grade I in 11 feet (26.2%), Grade II in 24(57.1%), Grade III in 6(57.1%), Grade IV in zero. 4. Pes planus and Pes cavus were significantly difference in foot pressure between forefoot and rearfoot(P<0.05). The future study needs detailed research and comparison with various variance between theses before and after correction.

  • PDF

Experimental method and evaluation of the calibration capability for the national calibration centers using the platinum resistance temperature sensors (백금저항온도센서를 이용한 국가교정기관의 교정능력 평가 및 실험방법)

  • Gam, Kee-Sool;Yoo, Sung-Ho;Kim, Sung-Min;Lee, In-Sick
    • Journal of Sensor Science and Technology
    • /
    • v.14 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Calibration capability was evaluated using the reference-grade platinum resistance thermometer (PRT) in the temperature range of $-50^{\circ}C$ to $250^{\circ}C$ for the national calibration centers. The reference-grade PRT was calibrated at the several fixed points, which was composed by the freezing points of Sn, In, the melting point of Ga and the triple point of water and Hg, before and after the round-robin test (RRT) experiments. The temperature scale of reference-grade PRT was compared to the local standard PRT's using the system of the national calibration centers. $E_{n}$ values was calculated by the temperature difference between the reference-grade PRT and the local standard PRT, and the best measurement capability. Finally, the capability of the national calibration centers was evaluated by the $E_{n}$ values.