• Title/Summary/Keyword: treatment system

Search Result 12,539, Processing Time 0.033 seconds

The System Improvement of the Individual Sewage Treatment System (개인하수처리시설의 제도개선에 관한 연구)

  • Jang, Hyo-Ju;Lee, Jang-Hown;Kang, Seon-Hong
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.1
    • /
    • pp.33-40
    • /
    • 2010
  • Individual sewage treatment system is classified into a sewage treatment system which treats all the domestic sewage and a water-purifier tank which treats only effluent flushing from the toilet. The number of registered manufacturers has increased rapidly since 2001. As a result, price competition has increased among the manufacturers and has caused the problems such as the inappropriate production of individual sewage treatment system, the unreasonable permit for building completion and the shortage of the professional technology of the community's public officials in charge. This study collected the problem cases that are related with existing individual sewage treatment system and operation. Efficient improvement plan for the stable supply, installation, maintenance of individual sewage treatment system were suggested.

The influence of complex traditional Korean medical treatment on the Peripheral Facial Paralysis induced stress (한방복합치료(韓方複合治療)가 STRESS로 유발된 말초성안면신경마비(末梢性顔面神經麻痺)에 미치는 영향)

  • Kim, Kyung-tae;Song, Ho-sueb
    • Journal of Acupuncture Research
    • /
    • v.21 no.4
    • /
    • pp.53-64
    • /
    • 2004
  • Objective: This study was to evaluate the influence of stress on Peripheral Facial Paralysis during the complex traditional korean medical treatment. Methods: We investigated 41 cases of patients with Peripheral Facial Paralysis who were given the complex traditional korean medical treatment. one group had stress as main factor, the other group didn't it. we evaluated the treatment effect of each group by using Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System. Results : 1. In age, sex, lesion, duration of disease, frequency of treatment, duration of treatment, we found that two groups have no significant differences. 2. Pain back of the ear showed the highest frequency in symptoms at onset. 3. Boyangwhanotang showed the highest frequency in oriental herb medicine treatment. 4. As a result of evaluation by using Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System, treatment score after 2weeks was marked more higher than score before treatment and treatment score after final treatment was more higher than treatment score after 2weeks on each groups. 5. After final treatment, Non-stress group had signficant result on Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System compared with stress group. Conclusion : These results suggested that patient with Non-stress group should be get better than stress group.

  • PDF

Treatment of Dyeing Wastewater by Magnetic-Biological Treatment System (자화-생물처리 시스템에 의한 염색폐수의 처리)

  • Lee, Seon-Ha
    • Journal of Environmental Science International
    • /
    • v.19 no.3
    • /
    • pp.371-377
    • /
    • 2010
  • The purpose of this study is to investigate treatment efficiency in dyeing wastewater treatment by the high rate aeration system(HRA) and a combination of the HRA with magnetized wastewater treatment system(MWS). At the hydraulic retention time of 16hr, 24hr, 30hr, BOD removal efficiencies of HRA system were 93%, 96% and 98%, combination of the HRA with MWS system were 94%, 96.8% and 98.2%, respectively. In ease of COD, at the hydraulic retention time of 16hr, 24hr, 30hr, COD removal efficiencies of HRA system were 66%, 77.1% and 83.1%, combination of the HRA with MWS system were 70.2%, 80.1% and 86.6%, respectively. The comparison of the HRA and combination of the HRA with MWS, effluent BOD of the former was 22.7mg/${\ell}$ and the latter was 19.4mg/${\ell}$, theretore biological treatment efficiency identified to increase by the MWS.

Sewage Treatment Characteristics and Efficiencies of Absorbent Biofilter Systems (흡수성 바이오필터 시스템의 오수처리 특성 및 효율)

  • Cheon, Gi-Seol;Kwun, Soon-Kuk;Kim, Song-Bae
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.46 no.5
    • /
    • pp.131-139
    • /
    • 2004
  • In this study, on-site sewage treatment tests were conducted using the Absorbent Biofilter System (ABS) under different hydraulic loading rates to examine its treatment characteristics and efficiencies and to determine its feasibility as a small on-site sewage treatment system in a rural area. Results showed that the removal rates of BOD and SS were satisfactory at hydraulic loading rates of 100~150 cm/day, meeting the Korean effluent water quality standards for the riparian zone (10 mg/L). In the case of nutrients (N, P), however, the system did not perform well, necessitating further improvement for nutrient removal. A comparative analysis indicated that as a small on-site sewage treatment system, the ABS would be more suitable than other treatment systems in terms of performance stability, maintenance requirement, and cost-effectiveness and could be applied as an alternative treatment system in Korean rural areas.

A Study on the improvement of treatment efficiency in a conventional sewage treatment plant (기존 하수처리장에서의 처리 효율개선에 관한 연구)

  • 안철우;박진식;문추연
    • Journal of environmental and Sanitary engineering
    • /
    • v.15 no.3
    • /
    • pp.50-56
    • /
    • 2000
  • In this study, sewage were treated with operating Two-step Aeration System and conventional activated sludge process together in a condition. At the same HRT 8hr of Two-step Aeration System and Activated Sludge Process, BOD treatment efficiency of 1st sedimentation basin effluent 36.9% by Two-step Aeration system was 12.3% higher than 24.65 by Activated Sludge Process and the COD treatment efficiency 39.8% by two-step Aeration System was 11.6.3% higher than 28.2% by Activated Sludge Process. BOD and COD treatment efficiencies of 2nd sedimentation basin effluent were 88.1% and 85.6% Two-step Aeration System and were 83.8% and 82.3% Activated Sludge Process. In the first treatment, as BOD was relatively removed a lot, F/M ratio 0.17, $0.21{\cdot}BOD/kg{\cdot}MLSS.d$ was maintained by Activated Sludge Process. Therefore it was proved that organic matter treatment efficiency by Two-step Aeration System os Higher than by Activated Sludge Process in a aeration time 8hr. $NH_4^{+}-N$ treatment efficiencies were 55.5% by Two-step Aeration System and 39.75 by Activated sludge Process. $NO_3^{-}-N$ concentration in 2nd. sedimentation basin effluent were 3.33% by Two-step Aeration System and 2.36% by Activated Sludge Process. From this result, Two-step Aeration System was proved more advantageous treatment process for nitrification than Activated Sludge Process. The fluctuation range of BOD, COD and SS concentration in 2nd sedimentation basin effluent $16~33mg/{\ell}$, $15~23mg/{\ell}$ and $14~22mg/{\ell}$ by Two-step Aeration System was smaller than $16~57mg/{\ell}$, $15~25mg/{\ell}$ by Activated sludge Process. Overall the fluctuation range in 2nd sediment basin effluent by was smaller than by Activated Sludge Process. As a result, it is possible for this Two-step Aeration with no facility investment and a little of operation condition change in a conventional sewage treatment plant to get stability and nitrification of treatment water quality.

  • PDF

Life Cycle Assessment (LCA) on Intensive Sludge Treatment System (Life Cycle Assessment (LCA)를 적용한 오니집약처리(汚泥集約處理)의 평가(評價))

  • Hwang, Yong-Woo;Kwon, Bong-Kee;Seo, Seong-Won
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.12 no.3
    • /
    • pp.65-74
    • /
    • 1998
  • Life cycle assessment (LCA) on two different sludge treatment systems, on-site treatment and pipe-collected intensive treatment was performed to estimate the environmental impact in the aspect of global warming effect. As a main parameter of the estimation, $CO_2$ was chosen and quantified through the whole life cycle of the treatment systems including construction, operation and dismantlement. In this study, the changes of $CO_2$ production unit (CPU) by up-scaling n currently used sludge treatment processes were also calculated. As the result, a larger amount of $CO_2$ was exhausted from the construction step of intensive treatment system than that of on-site treatment system, because an additional pipe-collection system was needed in intensive treatment system. However, the total amount of $CO_2$ exhausted from whole life cycle including not only construction and dismantlement but also 15 year-operation and maintenance was reduced by appling intensive treatment.

  • PDF

A Study on Civil Liability as to Medical Practices Against the Premium Medical Treatment System (선택진료제를 위반한 의료행위의 민사책임에 관한 고찰)

  • Baek, Kyounghee;Chang, Yeonhwa;Lee, Injae;Park, Dohyun
    • The Korean Society of Law and Medicine
    • /
    • v.15 no.2
    • /
    • pp.227-251
    • /
    • 2014
  • In current law, the premium medical treatment system gives patients the right of choice between normal medical treatment service and premium medical treatment service. Only the doctors having a career more than a certain period of time fixed in the law are eligible for providing the premium medical treatment service. So, the premium medical treatment system is highly related to the patients' right to know and the right of self-determination. The system is also relevant to the so-called 'economic explanation' notion because patients should pay additional fee when they want to use this system. Meanwhile, the situation as follows is problematic as to this system. Although a patient applied for using the premium medical treatment system and the patient also chose his or her own doctor specifically, another doctor who was not selected as premium doctor could make a medical accident. Then, is the another doctor liable for damages because the accident was a medical malpractice or a breach of medical contract? In this study, we are going to examine the problems related with the premium medical treatment system. First, we examine the current law related to the system. Second, we look into the economic explanation duty and its application to the premium medical treatment system. Finally, we examine a real judgment case about a medical practice against the premium medical treatment system and we propose our solution to this case.

  • PDF

State of Swerage Systems and Prospects in Korea (우리 나라의 하수도현황과 전망)

  • 김갑수
    • Journal of environmental and Sanitary engineering
    • /
    • v.8 no.2
    • /
    • pp.65-84
    • /
    • 1993
  • This study reviewed the current status and problems of sewerage system in Korea and then proposed possible methods to correct the problems. Also, evaluation of future development in sewerage system is included. It can be summarized as follows : 1. Investment in sewerage system is relatively low . 0.23% of GNP, Considering that the investment portion is 0.35% in OECD and 0.63% in Japan, it should be increased further. 2. The reasons wily the investment in sewerage system is low can be ' (1) Low priority is given to the investment in sewerage system. Local government builds and operates its own wastewater treatment plant. Local government as well as residents prefer to invest their money in roadwork, housing and parks to in wastewater treatment facilities because of greater investment effects. (2) Besides capital investment, more maintenance cost is needed for sewerage system. Proper operation of wastewater treatment facilities requires a well-trained operator. Because of public conception that operation of wastewater treatment facility is a dirty job, it is difficult to find a well-trained operator. (3) It is difficult to estimate the effect of sewerage system (4) Cost required to build and maintain wastewater treatment facility should be paid by people, who benefit from the facility. People to benefit are sometimes different from people to pay. 3. Advanced treatment is necessary to protect the bay aura and raw water source as well as to prevent eutrophication of lakes and ponds. 4. Wastewater treatment facility were mainly build in big cities during the decade of 1980. Followings should be solved first to expand the facilities. (1) Rapid repair and construction of sewer. (2) Technical development of wastewater treatment . Prevention of efficient and economical wastewater . Development of efficient and economical wastewater treatment techniques . Development of high-efficiency treatment using bioreactor . Reuse of wastewater treatment plant effluent (3) Sludge treatment and disposal . Composting of sludge cakes . Development of techniques to reduce the volume of sludge cake : incineration and reuse of sludge ash and slag. (4) Utilization of wastewater treatment facilities . Construction of community parks or sports families(ie, on the tops of the covered aeration tanks and sedimention tanks) Construction of wastewater treatment facilities under ground and of parking facilities and community parks above ground. (5) Education of wastewater treatment personal.

  • PDF

Influence of Dysgeusia on Prognosis of Peripheral Facial Paralysis (미각장애(味覺障碍)가 말초성안면신경마비(末梢性顔面神經麻痺)의 예후에 미치는 영향)

  • Yang, Ka-Ram;Song, Ho-Sueb
    • Journal of Acupuncture Research
    • /
    • v.24 no.3
    • /
    • pp.1-8
    • /
    • 2007
  • Objectives : This study was to evaluate the influence of dysgeusia on prognosis of peripheral facial paralysis. Methods: We investigated 40 cases of patients with Peripheral Facial Paralysis, and classified them as existence of dysgeusia. we evaluated the treatment effect of each group by using Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System before treatment and after final treatment. Results: 1. Postauricular pain showed the highest frequency in symptoms at onset. 2. As a result of evaluation by using Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System, treatment score after final treatment was marked higher than that before treatment within each group. 3. After final treatment, non-dysgeusia group showed signficant difference on Gross Grading System of House-Brackmann, Yanagihara's Unweighed Grading System compared with dysgeusia group. Conclusions: These results suggested that non-dysgeusia group should be get better than dysgeusia group in the patient with peripheral facial paralysis.

  • PDF

The Development of Industry Operation Control System using Intelligent Web Monitoring for the Heat Treatment Process (열처리공정의 지능형 웹 모니터링 산업용 공정제어 시스템 개발)

  • Oh, J.H.;Bae, H.J.;Choi, G.S.;Ahn, D.S.
    • Journal of Power System Engineering
    • /
    • v.9 no.4
    • /
    • pp.181-186
    • /
    • 2005
  • Because of advanced control technology, Shop floor control system of various kinds of equipment and machinery need a web based remote monitoring to control process efficiently. This paper presents the development of Operation Control System. Operation Control System(OCS) is based on intelligent web monitoring, so that OCS is improved the working condition for the line of heat treatment process and the product's quality. The developed OCS is consisted of Atmega128(MCU) based on embedded system, running the data logging of the line of heat treatment process. Web monitoring system is based on CS8900 ethernet controller and TCP/IP for remote monitoring responsibility between a server and clients and controlling the progress of entire system. The developed OCS is implemented on the line of heat treatment process and shows the improvement of environment condition, product's quality and efficiency of process line.

  • PDF