• Title/Summary/Keyword: treated sewage water

Search Result 152, Processing Time 0.025 seconds

A Study on Analysis of Reserves and Available Capacity of Unutilized Energy in Rural Community (농어촌지역 미활용에너지의 부존량과 이용 가능량 분석)

  • Park, Mi-Lan;Ryoo, Yeon-Su;Kim, Jin-Wook;Lee, Yong-Uk;Bae, Sung-Don;Chae, Kap-Byung
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.19-25
    • /
    • 2014
  • Alternative sources of energy take a higher interest in order to reduce the greenhouse gas under the Climate Change Convention, fossil fuel consumption, and lower social anxiety about nuclear power such as crisis involving the Fukushima plant, problem of obsolete equipment. The energy consumption of agriculture, forestry and fisheries in South Korea is 3,082,000toe by 2011, reliance on electrical energy(35%) and oil(57.2%) is very high with 92.2%. In this study, we examined reserves and available capacity of temperature difference energy for thermal discharge from plant, treated sewage, river water, dam, and agricultural reservoir in rural community. Reserves of unutilized energy are 455,735Tcal/yr in rural community, these accounts for 78% of total reserves 582,385Tcal/y. Thermal discharge from plant has the most reserves of unutilized energy in rural community, it is estimated that it has the reserves of 277,410Tcal/y. Available capacity of unutilized energy in rural community is total 134,147Tcal/y, thermal discharge from plant available for heating is the most 128,035Tcal/y, and it shows in the order of treated sewage 4,318Tcal/y, river water 1,653Tcal/y, and reservoir 141Tcal/y. Elevating temperature area of green house by 2012 is 21,208ha. The amount of energy required for heating the greenhouse a year is dbout 11,365Tcal/y with 8.5% of the total available capacity of unutilized energy.

Sewage and Tissue Wastewater Treatment Using Quartz Porphyry and Natural Zeolite (맥반석과 천연제올라이트를 이용한 도시하수와 화장지폐수처리)

  • Lee, Chang Hyun;Kim, Jae Yong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.34 no.8
    • /
    • pp.517-522
    • /
    • 2012
  • In this study, not only making an effort to find a solution for sewage and wastewater treatment, but also demonstrating a feasibility of wastewater disposal process which is treated with the cohesion and adsorption mechanism of sewage and wastewater using quartz porphyry and zeolite, which is a domestic natural resource. By using a jar test, we evaluated removal efficiency of $COD_{Cr}$ after reation. According to the result of experiment, when we injected 400~1,200 g/L of quartz porphyry and zeolite into a sewage as a coagulant, there was no difference of the rejection rates of $COD_{Cr}$, however, when quartz porphyry and zeolite, which were sintered at $600^{\circ}C$, were treated into urban sewage, removal efficiency of $COD_{Cr}$ had increased by about 15%, 3% respectively. In addition, we applied into a cosmetic tissue wastewater by using mixture of quartz porphyry and natural zeolite in order to analyze the applicability of other wastewater as well as Municipal Sewage.

Review of the Agricultural Water Quality Standards through Rice Culture with Treated Sewage Irrigation (오수처리수 관개 벼재배를 통한 농업용수 수질기준의 검토)

  • 윤춘경
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.2
    • /
    • pp.44-54
    • /
    • 1999
  • Agricultural water quality standards were reviewed through rice culture using treated sewage irrigation . The seqage from school building of Konkuk University was treated by a constructed wetland system, and theeffluent of the systeml was irrigated for rice culutre after nutrient concentration adjusted by dilution. Average concentration of COD, SS, T-N and T-P in irrigated water was 22.3mg/$\ell$, 6.5mg/$\ell$, 25.8 mg/$\ell$and 2.2mg/$\ell$, respectively. Treatment include irrigation of adjusted effluent with conventional fertilization (TWCF), adjusted effluent with no fertilization (TWNF). and effluent of the wetland system as it was with no fertilization (SWNF). These treatment plots were compared with control plot irrigated by tap water with conventional fertilization (CONTROL). Other environmentals for rice culture were identical for all the plots. Among them, TWCF showed the best growth rate and the highest yield, and constituents in the harvested rice showed not much difference among them. Which implies that irrigation with relatively high nutrient concentration compared to the current water quality standards may cause no adverse effect on rice culture and could be even beneficial . Although T-N for this study was 25 times greater than the current standards, rice culture wasnot adversely affected by irrigatino water quality and even beeter results were observed than the CONTROL. It could be mistakenly that clean irrigation water produces better agricultural product, however, it is not necessarily true. Irrigation water with moderate nutrient concentration can enhance the plant growth, and better result might be expected. Therefore, peer review and modification if necessary are needed to the current agricultural water quality standards, especially for the nutrient components.

  • PDF

The Effect of HRT and SRT on Treatment Efficiency of Activated Sludge Process for Low Concentration Municipal Sewage (저농도 도시하수 처리를 위한 활성슬러지공정에서 HRT 및 SRT가 처리효율에 미치는 영향)

  • Whang, Gye Dae;Kim, Min Ho;Ko, Sae Bom
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.11 no.1
    • /
    • pp.64-73
    • /
    • 1997
  • Most of the municipal wastewater treatment plants operated in Korea are designed for high concentrations municipal sewage. However, activated sludge process employed by municipal wastewater treatment plant is operated at low organic loading. The objective of this study was to determine optimum operating condition of activated sludge process for treatment of low concentration municipal sewage. Three bench scale activated sludge reactors were operated to investigate the effect of HRT and SRT on the COD and TSS removal efficiency. The average concentration of TSS, SCOD, SBOD and TKN in influent were 118mg/l, 61mg/l, 21mg/l, and 12mg/l, respectively. The activated sludge reactors operated with various HRT and SRT showed about 89-93% TSS removal efficiency. HRT and SRT does not affect the TSS removal efficiency of actvatied sludge process significantly. However, HRT affected the SCOD removal efficiency slightly. As the HRT decreases from 13hours to 3hours, the SCOD removal efficiency decreases from 67% to 56%. The average effluent TCOD concentration of the reactor operated with 3hours of HRT was approximatly 40-45mg/l. Kinetic coefficient yield (Yt) and decay coefficients(Kd) were 0.594-0.954 mgMLVSS/mgCOD and $0.0197-0.0317day^{-1}$, respectively. Low concentration municipal sewage can be treated with 3 hours of HRT without effluent quality deterioration and SRT does not affect the substrate removal efficiency at this operation condition.

  • PDF

The Quantitative Analysis of Polycyclic Aromatic Hydrocarbons(PAHs) in Sewage Sludge by Gas Chromatography-Ion Trap Mass Spectrometry (가스크로마토그래피-이온트랩질량분석법을 이용한 하수슬러지 중 다핵방향족탄화수소(PAHs) 함량 분석)

  • 남재작;소규호;박우균;조남준;이상학
    • Journal of Environmental Science International
    • /
    • v.11 no.4
    • /
    • pp.367-373
    • /
    • 2002
  • The polycyclic aromatic hydrocarbons(PAHs) content in sewage sludge was determined by gas chromatography linked to ion trap mass spectrometry(GC/ITMS) with five deuterated PAHs as internal standards. The minimum detection limit was from 1.66 to 7.14 pg for individual PAH by GC/ITMS. For determining total PAHs(∑PAH) in sewage sludge 84 samples from 74 waste water treatment plants in whole country were analyzed. The average content of ∑PAH far whole samples was 3,289$\pm$3,098 $\mu\textrm{g}$/kg, and ranged from 142 to maximum 20,102 $\mu\textrm{g}$/kg. According to the number of population of the city, the areas were classified as five regions, ie. big, large, middle, small, and rural area in which the waste water treated plants were grown. The contents of PAHs were 4,689$\pm$5,503, 5,839$\pm$6,401, 3,725$\pm$2,053, 2,237$\pm$2,069, and 2,475$\pm$1,489 $\mu\textrm{g}$/kg, in big, large, middle, small, and rural area, respectively.

Management of TOC and COD Organic Matter of Effluents in Sewage Treatment Plants (하수처리장 방류수에서 TOC와 COD 유기물관리)

  • Hwang, Seuk-Ho;Park, Je-Chul
    • Journal of Environmental Science International
    • /
    • v.27 no.4
    • /
    • pp.261-266
    • /
    • 2018
  • In this study, the organic matter of effluents from sewage treatment plants, located in the Nakdong watershed was investigated. Regression equations were computed using treated sewage data to convert the chemical oxygen demand(COD) concentrations, which are mostly available from an open database, into total organic carbon(TOC) concentrations. The average concentration of organic matter in the sewage treatment plant effluents were 2.2~16.8 mg/L for COD and 3.4~14.3 mg/L for TOC. The concentrations of COD were positively correlated with the TOC concentrations. The correlation between COD and TOC was relatively high, at 0.865(p<0.01). Based on these results, regression analysis was conducted. The regression equation for TOC was $1.651{\times}COD_{Mn}-0.084$ ($R^2=0.84$). Furthermore, organic matter-related databases for more sewage treatment plants need to be built in order to establish TOC standards and manage the water quality.

Economic Evaluation of Integrated Operation & Management through Operation Performance Analysis of Sewage Facilities (하수도시설 통합운영 성과분석을 통한 통합운영관리의 경제성 평가)

  • Shin, Jungsub;Chung, Seokhyun;Cho, Byoungog;Lee, Kwanhyung;Kang, Seonhong;Kim, Yongdae;Yoon, Joonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.31 no.1
    • /
    • pp.63-72
    • /
    • 2017
  • For economic evaluation of integrated operation to sewage facilities, benefit-cost analysis was performed to watershed sewage works project in 7 watershed areas, 156 facilities. In this study, the cost before and after integrated operation was compared and benefits are calculated from the reduction of operators, increasement treated pollution loads, reduction cost through operation convenience, reduction water consumption through effluent reuse, and improvement of life benefit. The result showed that cost was 8,500million won and benefit was 16,747million won, so benefit was 49% higher than cost. B/C analysis result showed that B/C ratio was 1.97 and it is similar to other researches. The benefits of integrated operation included convenience of data management, increase of emergency response, decrease of complains with sewage which was not reflected numerically, so the benefits of integrated operation were expected much greater than this result

하수슬러지의 토양개량재 적용시 유기인계 농약의 흡착능력에 관한 연구

  • 임은진;이재영
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2004.04a
    • /
    • pp.125-130
    • /
    • 2004
  • This study has been assessed the influence of applying sewage sludge to soil amendments on the sorption properties, and leaching potential of three commonly used organophosphorus pesticides, Diazinon, Fenitrothion, and Chlorpyrifos. A sandy soil with a low content of organic carbon was treated with sewage sludge with a ratio sandy soil : sludge ratio of 30:1. The sorption was determined with the batch equilibrium technique. The sorption isotherms could be described by Freundlich equation. The Freundlich constant, K value which measures sorption capacity, were 3.97, 9.94, 22.48 for Diazinon, Fenitrothion, Chlorpyrifos in non-amended soil. But in amended soil, K value was 12.58, 28.47, and 61.21 for Diazinon, Fenitrothion, and Chlorpyrifos. The overall effect of sewage sludge addition to soil was to increase pesticides adsorption, due to the high sorption capacity of the organic matter. The effect of sludge on tile leaching of pesticides in the soil was studied using packed soil columns. Total recoveries of pesticides in soil and leachate with leaching in soil column, were in the range of about 73~84%, was reduced with the passage of time. Diazinon moved more rapidly than Chlorpyrifos in the unamended soil due to greater sorption and lower water solubility of Chlorpyrifos. Total amounts of pesticides leached from the sewage sludge amended soils were significantly reduced when compared with unamended soils. This reduction may be mainly due to and increase in sorption in amended soils, as a consequence of the increase in the organic matter content.

  • PDF

A Study on the Estimation of Irrigation Water for Sewage Treated Water Reuse for Agriculture (하수처리수의 농업용수 재이용을 위한 관개수량 산정방법에 관한 연구)

  • Cho, Hyun Kyung;Kim, Sang Min
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.61 no.2
    • /
    • pp.97-104
    • /
    • 2019
  • The purpose of this study was to establish the estimation method of irrigation water amount for sewage treated water reuse for agricultural purpose. To calculate the irrigation water amount, we adopted Penman-Monteith for potential evapotranspiration estimation and applied crop coefficient and irrigation efficiency factor. We developed the irrigation water amount calculation program using C language in Xcode environment. The target district for calculation is having 259 ha of agricultural land located near the Jinyeong Clear Water Circulation Center in Hanrim-myeon, Gimhae city. The meteorological data of the study area were obtained from Changwon weather station from 1986 to 2017. Calculated average and maximum of annual mean potential evapotranspiration were 2.72 mm/day and 6.22 mm/day, respectively. We used K-S (Kolmogorov-Smirnov) for goodness-of-fit test to find optimal probability distribution of annual mean and maximum evapotranspiration. As a result, the normal distribution was selected for the appropriate distribution. The annual mean and maximum potential evapotranspiration for 10-year return period by applying normal distribution were 2.88 mm/day and 6.76 mm/day, respectively. Assuming that the irrigation efficiency is 80%, the irrigation water requirement was calculated as $36.05m^3/day/ha$ and $84.45m^3/day/ha$, respectively, when annual mean and maximum potential evapotranspiration were applied. The actual irrigation water amount can be calculated by applying the crop coefficient and cropping days for the study area based on the developed irrigation water amount estimation program in this study.

A Study on Energy Usage Monitoring and Saving Method in the Sewage Treatment Plant (공공하수처리시설에서 에너지 사용현황 및 절감방안 연구)

  • Kim, Jongrack;Rhee, Gahee;You, Kwangtae;Kim, Dongyoun;Lee, Hosik
    • Journal of Korean Society on Water Environment
    • /
    • v.36 no.6
    • /
    • pp.535-545
    • /
    • 2020
  • This study aims to conserve and monitor energy use in public sewage treatment plants by utilizing data from the SCADA system and by controlling the aeration rate required for maintaining effluent water quality. Power consumption in the sewage treatment process was predicted using the equipment's uptime, efficiency, and inherent power consumption. The predicted energy consumption was calibrated by measured data. Additionally, energy efficiency indicators were proposed based on statistical data for energy use, capacity, and effluent quality. In one case study, a sewage treatment plant operated via the SBR process used ~30% of energy consumed in maintaining the bioreactors and treated water tanks (included decanting pump and cleaning systems). Energy consumption analysis with the K-ECO Tool-kit was conducted for unit processing. The results showed that about 58.7% of total energy consumed was used in the preliminary and biological treatment rotating equipment such as the blower and pump. In addition, the energy consumption rate was higher to the order of 19.2% in the phosphorus removal process, 16.0% during sludge treatment, and 6.1% during disinfection and discharge. In terms of equipment energy usage, feeding and decanting pumps accounted for 40% of total energy consumed following 27% for blowers. By controlling the aeration rate based on the proposed feedback control system, the DO concentration was reduced by 56% compared pre-controls and the aeration amount decreased by 28%. The overall power consumption of the plant was reduced by 6% via aeration control.