A Study on the Overheating of the Power Cable Tray

  • Choi, Hyung-Joo;Lee, Heung-Ho
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.2 no.4
    • /
    • pp.413-420
    • /
    • 2013
  • This paper includes the results of the electromagnetic finite element analysis with regard to overheating problem of the power cable tray due to asymmetric magnetic flux density. This phenomenon was experienced in the utility power plant, Korea. The influences of the power cable arrangements and material of the tray were analyzed to find the best solutions using the eddy current-thermal coupled analysis.

Design of Packer Holder Mechanism in an Egg Grading Machine (계란선별기의 계란이송 메커니즘 해석 및 설계)

  • Lee, Jang-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.2
    • /
    • pp.96-104
    • /
    • 2008
  • An egg grading machine is composed of many mechanisms of which functions are to carry eggs to the bucket in that sensors are located to categorize eggs by their weight, to transfer eggs from the basket of packer holder to the mold tray, to feed the mold tray dispenser after egg chairs are filled with eggs. This paper deals with the analysis and new design of packer holder mechanism of which function is transfer eggs vertically from the bucket conveyor to the mold tray dispenser. Egg is fragile to impact so in designing packer holder mechanism it is necessary to estimate moving speed, acceleration and impact when eggs are touched by any links of mechanism and mold tray dispenser. A new packer holder mechanism is proposed in this paper, which use quick return mechanism composed of 6 links with pin and contact joints.

A Study on Reduction of Sound Noise Induced by Disk Rotation in Optical Disk Drives (광 디스크 드라이브의 공력소음 감소에 관한 연구)

  • 송인상;박건순;최학현;김수경;이승엽
    • Journal of KSNVE
    • /
    • v.9 no.4
    • /
    • pp.693-702
    • /
    • 1999
  • We study the characteristics of airflow and sound noise induced by disk rotation in optical disk drives. The characteristics of airflow around a rotating disk surrounded by various tray structures are numerically investigated using a commercial CFD program and then compared with experimental results. Sound pressure and intensity caused by the fluid-structure interactions in the CD/DVD-ROM drive are measured, and the effect of the ariflow on the sound noise and disk vibration is discussed. In order to reduce airflow-induced noise and vibration around the rotating disk, tray geometry is modified. Both numerical and experimental studies implemented with different tray models show that the improved tray model alters the characteristics of the disk-induced airflow, causing the reduction of the airflow-induced sound level.

  • PDF

Transport Phenomena in Solid State Fermentation: Oxygen Transport in Static Tray Fermentors

  • Muniswaran, P.K.A.;Moorthy, S.Sundara;Charyulu, N.C.L.N.
    • Biotechnology and Bioprocess Engineering:BBE
    • /
    • v.7 no.6
    • /
    • pp.362-366
    • /
    • 2002
  • A mathematical model has been developed for describing the oxygen concentration during the exponential growth of microorganisms, in a static solid substrate bed supported on a tray fermentor. The model equations comprise of one partial differential equation for mass transfer and an ordinary differential equation of growth. After nondimensionlisation, analytical solution tn the model has been obtained by the method of Laplace transforms. An expression for critical thickness of bed is deduced from the model equation. The significance of the model in the design of tray fermentors is discussed. The validity of the discussion is verified by taking an illustration from the literature.

ADHESIVE PROPERTY OF POLYSULFIDE IMPRESS10N MATERIAL ON THE TRAY RESIN AND BORDER HOLDING MATERIALS (타액오염이 트레이 레진 및 변연 형성재와 Polysulfide 인상재의 접착력에 미치는 영향)

  • Kim, Yong-Hak;Yang, Hong-Seo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.38 no.5
    • /
    • pp.650-658
    • /
    • 2000
  • This study was investigated to compare the bond strength of polysulfide adhesive between tray resin and border molding materials and to evaluate the effect of saliva contamination on them. We made the 135 resin tray secimens with a dimension of $1{\times}1{\times}1cm$ and divided them into 3 groups by the materials 1) Quicky group, 2) Compound group, and 3) Impregum group Each group was subdivided by saliva contimination. Group S1 : applied adhesive without saliva contamination Group S2 : applied adhesive after drying 15seconds after saliva contamination Group S3 : applied adhesive no after saliva contamination. Tensile tests were performed with a Universal Load testing machine. Results showed Impregum group significantly higher bond strength than Quicky group, but there was no significant difference in adhesive bond strength between Compound group and Quicky group in experimental group by materials In experimental group by saliva contamination, S1 group is significantly higher bond strength than S2 group and S2 group is significantly higher bond strength than S3 group in Quicky group and S1, S2 group is significantly higher bond strength than S3 group in Compound group and Impregum group. Impression compound and Impregum F which are usually used as an individual tray border mold-ing material can be said to be satisfied in adhesive bond strength to polysulfide impression materials. After try-in and clinical adjustment are performed, a custom tray should be properly rinsed and air dried before tray adhesive was placed.

  • PDF

Accuracy of new implant impression technique using dual arch tray and bite impression coping

  • Lee, Shin-Eon;Yang, Sung-Eun;Lee, Cheol-Won;Lee, Won-Sup;Lee, Su Young
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.4
    • /
    • pp.265-270
    • /
    • 2018
  • PURPOSE. The purpose of this in vitro study was to evaluate the accuracy of a new implant impression technique using bite impression coping and a dual arch tray. MATERIALS AND METHODS. Two implant fixtures were placed on maxillary left second premolar and first molar area in dentoform model. The model with two fixtures was used as the reference. The impression was divided into 2 groups, n=10 each. In group 1, heavy/light body silicone impression was made with pick up impression copings and open tray. In group 2, putty/light body silicone impression was made with bite impression copings and dual arch tray. The reference model and the master casts with implant scan bodies were scanned by a laboratory scanner. Surface tessellation language (STL) datasets from test groups was superimposed with STL dataset of reference model using inspection software. The three-dimensional deviation between the reference model and impression models was calculated and illustrated as a color-map. Data was analyzed by independent samples T-test of variance at ${\alpha}=.05$. RESULTS. The mean 3D implant deviations of pick up impression group (group 1) and dual arch impression group (group 2) were 0.029 mm and 0.034 mm, respectively. The difference in 3D deviations between groups 1 and 2 was not statistically significant (P=.075). CONCLUSION. Within limitations of this study, the accuracy of implant impression using a bite impression coping and dual arch tray is comparable to that of conventional pick-up impression.

Retentive Force of Adjustable Dental Impression Trays with Different Synthetic Resin Materials (합성수지 재료에 따른 가변형 치과 인상용 트레이의 유지력에 관한 연구)

  • Lee, In-Seob;Lee, jin-Han;Kim, Yu-Lee;Dong, Jin-Keun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.22 no.1
    • /
    • pp.11-21
    • /
    • 2006
  • The adjustable dental impression trays were made for being adjusted their width automatically along the width of patient's dental arch. The purpose of this study was to investigate the retentive force of adjustable dental impression trays made of different synthetic resin materials. Three pairs of adjustable trays were made of ABS(acrylonitrile butadiene styrene) synthetic resin, polyurethane synthetic resin and polycarbonate synthetic resin with a hole and without a rim on the border area of them. The experiment was done with the horse-shoe shaped metal plate to pull out the set impression body from the tray jig which was made for holding the tray on the lower part of Universal Testing Machine(UTM, Zwick Z020, Zwick Co., Germany). After the alginate impression in the tray was allowed to set four minutes, a tensile force was applied at right angles to the tray which had been previously seated on the jig. The force was applied to measure a maximum force by use of UTM at a constant strain rate 100mm per minute. The results obtained in this study were as follows : 1. The upper trays were showed higher retentive force than lower trays in three tray materials. 2. There was no significant difference in the retentive force of the tray materials(p>0.05).

Development of Parametric Design Tool for Offshore Plant Cable Tray Using PML (프로그램 매크로언어를 이용한 해양 플랜트 케이블 트레이의 파라메트릭 설계 도구 개발)

  • Kim, Hyun-Cheol
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.2
    • /
    • pp.632-637
    • /
    • 2019
  • The cable tray design of an offshore plant production design is to optimally arrange the 3D modeling so that the cable can be installed without interfering with the structural members and various outfit equipment, and it is performed using a PDMS (Plant design management system), which is a 3D CAD system for an offshore plant layout. This study reviewed the development of PML (Programmable macro language) for a PDMS supporting offshore plant cable tray design and examined the efficiency compared to the existing method. Cable tray design PML developed in this paper enables fully parametric design using electrical outfit template library, allowing a rapid response to frequent modifications due to design changes and minimizing repetitive work fatigue by reflecting the accumulated design experience. In addition, the developed system was applied to the offshore plant structure module and it improved the work efficiency by more than 50% compared to the existing method.

Physicochemical effects of different processing temperatures on 5-hydroxymethyl-2-furaldehyde and the volatile flavor of domestic honey

  • Suk-Ho, Choi;Myoung Soo, Nam
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.4
    • /
    • pp.899-910
    • /
    • 2021
  • This study was performed to suggest concentration methods leading to the production ofhoney with an excellent flavor by examining the effects of the concentration temperature and method on changes in 5-hydroxymethyl-2-furaldehyde (5-HMF) levels and the flavor components of honey. The 5-HMF contents of honey samples concentrated in a tray concentrator at 45, 50, 60, and 70℃ were 2.1, 2.3, 2.5, and 3.1 mg·kg-1, respectively, demonstrating that the 5-HMF contents increased as the concentration temperatures were increased. The honey vacuum-concentrated at 70℃ showed a higher 5-HMF content than that at 60℃, similar to the tray-concentrated honey at different temperatures. The main and other minor flavor components of the honey were volatilized and significantly reduced after vacuum concentration. In the tray concentration, all of the honey samples concentrated at 40, 50, 60, and 70℃ showed flavor component patterns similar to each other, and most of the main and other minor flavor components in the honey were volatilized and significantly reduced after tray concentration. As such, most of the main and other minor flavor components of the honey were mostly removed at 70℃ after both the vacuum concentration and tray concentration processes. The effects of the concentration method and temperature on the viscosity, 5-HMF level, and flavor components of the honey were found to be significant in this study. Given that the components of honey were shown to undergo significant physicochemical changes depending on the concentration method used and temperature during laboratory-scale production, the concentration methods devised in this study can be applied industrially.