• 제목/요약/키워드: tray

검색결과 579건 처리시간 0.033초

가변형 치과 인상용 트레이로 제작된 모형의 재현성 (Accuracy of Stone Cast Produced by Adjustable Dental Impression Tray)

  • 박광수;동진근;심헌보;오상천
    • 구강회복응용과학지
    • /
    • 제22권4호
    • /
    • pp.317-328
    • /
    • 2006
  • Purpose: This study was performed to measure the accuracy of adjustable dental impression trays by a scanning laser three-dimensional digitizer. Materials and Methods: Metal stock tray and adjustable stock trays were used for 40 stone casts(10 casts each) duplicated a resin master model of mandible and maxilla. The type IV dental stone was poured in a allginate impressions and allowed to set for one hour. The casts were digitized using an optical digitizer. The distance between the reference points were measured and analyzed on the graphic image of 3-D graphic software (CATIA version 5.0). The statistical significance of the differences between the groups was determined by a two-way ANOVA. Results: There were no significant differences between the accuracies of the adjustable stock tray and the master model except anterior arch width of the upper arch and the diagonal arch length and arch length(one side) of the lower arch. Conclusion: The adjustable stock trays showed clinically acceptable accuracies of the study casts produced by them.

DEVELOPMENT OF TRANSPLANT PRODUCTION IN CLOSED SYSTEM PART I

  • Uenaka, T.;Murase, H.
    • 한국농업기계학회:학술대회논문집
    • /
    • 한국농업기계학회 2000년도 THE THIRD INTERNATIONAL CONFERENCE ON AGRICULTURAL MACHINERY ENGINEERING. V.III
    • /
    • pp.757-763
    • /
    • 2000
  • It is fundamental to control individual condition of every seedling. Automatic individual control is used by data control and analysis at on-line. As a result the best condition system was build without all waste. This system uses one of new technology irrigation system. This irrigation system supply accurate quantity of nutrient solution in the shortest time. The system named the upward injection irrigation system. First of all it is necessary to be considered whether the soil is proper or improper for upward injection irrigation system. It is important that root absorb nutrient solution as fast as possible. The ability of spreading, storing water, contamination of environment and cost were considered when choose the medium. The soil of organic culture is developed recently. The soil consists of paper pulp and vermiculite. The new soil is more suitable than ordinary medium for growing plant because this medium is made of paper pulp. The ability of store and spread of water is it's feature. We can make paper tray of this paper pulp's raw material. It is possible that pulp tray replaced plastic tray. The original plug tray of growing seedling system can make which consist of pulp medium and pulp tray. In this study, it was examined whether the plug seedling of paper pulp medium grow with upward injection irrigation system in this seedling plant system. At the same time, examine ability of store and spread of water and how to grow plant on the paper pulp medium.

  • PDF

플러그묘 자동이식기의 묘 자동공급 및 이식기구에 관한 연구 (Automatic Feeding and Transplanting Mechanism for Plug Seedling Transplanter)

  • 민영봉;문성동
    • Journal of Biosystems Engineering
    • /
    • 제23권3호
    • /
    • pp.259-270
    • /
    • 1998
  • An automatic seedling transplanter, employed an innovative plug-seedling feeder was developed by improving the problems of conversational feeding and transplanting mechanisms. With conventional methods, missing and damage rates of seedling were high for long seedlings over 20cm and also breaking seed-bed was frequently observed. Thus, a pushout-bucket slide-hopper type trandsplanter was devised and tested. Test results of picking and transferring accuracies of the developed transplanter are as follows : A prototype transplanter performed with 1.5% of missing rate. The deviations of horizontal feed ranged from -0.3mm to 2.8mm and averaged 0.673mm for the 128-hoe test tray : and ranged from -lmm to +3mm and averaged 0.785mm for the 200-hole test tray. The deviations could decrease with precise manufacturing and lightening the mechanism. The maximum and deviations of vertical feed were -2.3mm and + 1mm, respectively, for the 128-hole test tray ; and were +3mm and +2.5mm, respectively, for the 200-hole test tray. The missing rate, seeding bruise rate and seed-bed damage rate were esitmate to be 1.3%, 0.4% and 3.5%, respectively, with the developed automatic transplanter.

  • PDF

가변형 치과 인상용 트레이의 적합도에 관한 예비연구 (A Preliminary Study on the Fitness of Adjustable Dental Impression Trays)

  • 김민정;오상천;동진근
    • 구강회복응용과학지
    • /
    • 제21권1호
    • /
    • pp.83-93
    • /
    • 2005
  • This study was designed to investigate the fitness of adjustable dental impression trays. The size and shape of these trays were designed from the results of the dental arch size of Korean adults. Tray samples were made by CAD-CAM working. A hundred dental students(male:50, female:50) were selected for taking irreversible hydrocolloid impression using these trays. The author measured the width and length of impression material on the several measuring points. The results obtained were as follows : 1. Uniform impression material thickness was achieved by controlling the width of the tray using stops and beveled guides. 2. In the upper tray, the impression material thickness was measured to be rather great showing thickness of the labial vestibule 8.3 mm and the midpalatal part 8.6 mm. 3. In the lower tray, length of the impression material of the labial vestibule of first, second premolar contact point was 7.8 mm, and thickness of the lingual part of premolars(1.8 mm) and molars(1.9 mm) showed small values. 4. In the lower tray, the impression material thickness of the buccal shelf area(0.2 mm) and the retromolar pad area(0.6 mm) was measured to be too small.

케이블 트레이 설계시스템 개발 (Development of a Design System for a Cable Tray)

  • 최두순;최우석
    • 한국기계가공학회지
    • /
    • 제16권4호
    • /
    • pp.89-96
    • /
    • 2017
  • A cable tray is a structure made of metal or a non-combustible material that supports cables in the electrical wiring of buildings. Cable trays should be developed to meet the various requirements of the construction site. In this study, a design system was developed to calculate the maximum support load and the maximum deflection according to the cross-sectional shape of the cable tray. The cross-sections of cable trays were modeled by combining linear and arc elements, and cross-sectional characteristics such as the 2nd moment of area were calculated. The distributed load and the concentrated load were applied to the cable tray using the Euler beam theory, and then the deflection profiles and maximum stress were calculated. To verify the developed system, deflection distributions and maximum stresses for two types of cable trays were calculated and compared. The maximum deflection and maximum stress errors calculated from the developed system were found to be less than 4% compared with numerical analysis results.

일체형 케이블 트레이의 롤포밍 성형해석에 관한 연구 (Roll Forming Analysis for All-in-one Cable Tray)

  • 한명철;성창민;김정관;권유홍
    • 한국기계가공학회지
    • /
    • 제17권4호
    • /
    • pp.143-149
    • /
    • 2018
  • A cable tray is a fixture to support and protect electrical and communication cables. In this study, a roll-forming analysis is conducted to produce an all-in-one cable tray. The number of process stands is calculated using an empirical formula. By applying bending methods to the design of the roll flower pattern, the final process stands and forming angles are determined. The shape and stress variations in the cable tray are modeled and observed by roll forming analysis using LS-DYNA Software. The width of the side rail and the maximum stress on all stands does not exceed the reference values. The forming machine and rolls are manufactured based on the results of the roll forming analysis. In addition, all-in-one cable trays satisfy the National Electrical Manufacturers Association standards when they are manufactured according to this design.

고속으로 회전하는 광디스크 드라이브의 공력 소음원 규명 및 소음저감방법 (Identifications and Reduction Methods of Aerodynamic Noise Sources in High Speed Rotating Optical Disk Drive)

  • 김용석;이덕주
    • 한국소음진동공학회논문집
    • /
    • 제17권6호
    • /
    • pp.477-483
    • /
    • 2007
  • Major noise source in high speed rotating optical disk drives (CD and DVD-ROM) arises due to the high-speed airflow produced from the upper and lower surfaces on the rotating disk. The present paper deals with the experimental approach how to identify the noise source based on the fundamental principles of aeroacoustics and to propose a reduction method of the noise source. The CD-ROM device is composed of disk, window tray, motors at the bottom place and electronic circuit plate also located below the window plate. The window is cut in the tray to read the disk information using the optical device located below the tray and moving linearly from the center of the disk through the end of the disk. All components are possible noise generators. Experimental studies were carried out in the anechoic room with various design modifications, such as tray geometry, window size and hole location on tray, to identify the major aerodynamic noise source and significant reductions of the aerodynamic noise were obtained.

임플란트용 플라스틱 트레이를 이용하여 하악 흡착의치를 제작하는 방법 (Technique for fabricating a mandibular suction denture with a plastic implant tray)

  • 이주형
    • 대한치과보철학회지
    • /
    • 제59권1호
    • /
    • pp.36-42
    • /
    • 2021
  • 하악 무치악 환자에게 치과용 임플란트를 이용한 피개의치가 우선적으로 추천된다. 그러나 많은 환자들은 경제적, 건강상태를 이유로 전통적인 총의치를 선택하기도 한다. 전통적인 방법으로 제작된 총의치는 치조골 흡수가 심한 환자에서 간혹 유지 및 안정에 한계를 보인다. 이런 한계를 극복하기 위해서 폐구인상법을 이용한 흡착의치가 사용되고 있다. 그러나 기존의 방법은 Frame cut back tray, Centric tray, Gnathometer M이 필요하다. 본 논문은 진료실에서 흔히 사용되는 치과재료를 이용한 하악 흡착의치 제작과정을 소개하고자 한다.

TENSILE BOND STRENGTH BETWEEN ELASTOMERIC IMPRESSION MATERIALS AND TRAY RESINS DEPENDING ON THE THICKNESS OF THE TRAY ADHESIVE

  • Kim, Tae-Won;Moon, Hong-Seok;Lee, Keun-Woo;Chung, Moon-Kyu
    • 대한치과보철학회지
    • /
    • 제44권6호
    • /
    • pp.699-711
    • /
    • 2006
  • Statement of problem. Elastomeric impression materials have been widely used to obtain an accurate impression. However there have not been enough studies on the influence of the thickness of the tray adhesives on the bonding strength between the trays and the elastomeric impression materials. Purpose. In order to understand the relationship between the thickness of the tray adhesive and the tensile bond strength and to suggest the thickness at which the bonding strength is strongest, tensile bond strength related to the thickness of adhesives of 3 different elastomeric impression materials were tested. Materials and methods. 3 impression materials, $Permlastic^{(R)}$. Regular Set(Kerr Corp., Romulus, Michigan, U.S.A.), $Impregum^{TM}$ $Penta^{TM}$(3M ESPE, Seefeld, Germany), and Aquasil Ultra Monophase Regular Set Smart Wetting.(Dentsply Caulk, Milford, Delaware, U.S.A.), were used in this study, and tray adhesives from the same manufacturers of the impression materials were used, which were Rubber Base Adhesive, Polyether Adhesive, and Silfix, respectively. The tray specimens were prepared by autopolymerizing the tray material(Instant Tray Mix, Lang, Wheeling, Illinois, U.S.A.), and a PVC pipe was used to house the impression material. In group A, tray adhesives were applied in multiple thin layers of 1 to 5 and in group B, adhesives were applied only once, in the thickness equivalent to several applications. Lightness($L^*$) of the adhesion surface was measured with a spectrophotometer(CM-3500d, Konica Minolta, Sakai, Osaka, Japan). The tensile bond strength of the elastomeric impression material and the tray resin was measured with universal materials testing machines(Instron, Model 3366, Instron Corp, Nowood, Massachusetts, U.S.A.). A formula between the number of adhesive application layers and the lightness of the adhesion surface was deduced in group A, and the number of adhesive layers in group B was estimated by applying the lightness($L^*$) to the deduced formula. Results. 1. In group A, a statistically significant increase in tensile bond strength appeared when the number of application layers increased from 1 to 2 and from 4 to 5, and no significant difference was present between 2, 3, and 4 layers in Permlastic. In Impregum, the tensile bond strength was significantly increased when the number of adhesive layers increased from 1 to 3, but no significant difference after 3 layers. In Aquasil, the tensile bond strength significantly increased as the number of application layers increased up to 4 but showed no significant difference between 4 and 5. 2. In group B, the tensile bond strength was decreased when the thickness of the adhesive increased in Permlastic. Impregum showed an increased tensile bond strength when the thickness of the adhesive was increased. In Aquasil, the tensile bond strength increased as the number of adhesive application layers increased up to approximately 2.5 layers but it sharply decreased after approximately 4.5. Conclusion. From the study, the common idea that it is better to apply a thin and single coat of tray adhesive needs correction in more detailed ways, and instructions on some of the tray adhesives should be reconsidered since there were several cases in which the tensile bond strength increased according to the increase in the thickness of the adhesives.

전기자동차 배터리 트레이 내에서의 열전달 해석 (Heat transfer analysis in the battery tray for electirc vehicle)

  • 임종수;신동신
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2002년도 학술대회지
    • /
    • pp.651-654
    • /
    • 2002
  • Study of electric vehicle is popular with automobile company. However, battery cooling problem has delayed development of electric vehicle. Lifetime of electric vehicle's battery depends on the cooling effect for the battery tray. One model was simulated by 3-D, steady state, incompressible, k-e turbulent model simulation. It is found that flow inlet, outlet and inlet position are very important design parameters.

  • PDF