• 제목/요약/키워드: travelling mode

검색결과 28건 처리시간 0.032초

자기부상열차용 선형유도전동기의 회생 제동 특성 해석 (Regenerative Braking Characteristics of Linear induction Motor for MAGLEV)

  • 박승찬;이원민;김정철;박영호
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1866-1870
    • /
    • 2008
  • In this paper, electric braking performances of linear induction motor(LIM) designed for propelling the MAGLEV are presented. Regenerative braking is carried out from 110km/h to 20km/h, and plugging which converts the direction of travelling magnetic field is carried out in the low speed region below 20km/h. It is important to reduce attractive force which can affect the magnetic levitation load during regenerative braking or plugging operation mode. So in this paper the braking performances are analyzed by finite element method. As a result, braking force, attractive force, phase current, voltage to frequency patterns and its magnetic fields of braking LIM are presented.

  • PDF

가솔린엔진의 전자제어 센서파형 측정을 통한 점화2차 파형 분석에 관한 실험적 연구 (An Experimental Study on the Secondary Waveform Analysis according to Measure of Electronic Control Waveform)

  • 유종식;김철수;차경옥
    • 한국자동차공학회논문집
    • /
    • 제19권1호
    • /
    • pp.95-100
    • /
    • 2011
  • The test was done on cars travelling at speeds of 20km/h, 60km/h and 100km/h, the performance testing mode for chassis dynamometer. In this test, the secondary waveform were measured, including those using faulty MAP sensors, oxygen sensors and spark plugs. The results from these measurements and their analysis of secondary waveform can be summarized as follows: 1) The secondary waveform measured from the faulty oxygen sensor showed a lot of noise around peak voltage and in the rising and falling sections during spark line which means that the air fuel mixture was non-homogeneous. 2) The secondary waveform from the faulty MAP sensor showed the worst shape compared to other sensors, including variation of spark line, state of air-fuel mixture and velocity of flame front. 3) The spark line time of secondary waveform using a faulty spark plug displayed the shortest and smallest energy spark line, which means that a misfire occurred.

스탠드간 장력프로파일을 이용한 열연판 평탄도 제어시스템 (Flatness Control System of the Hot Strip by Using Tension Profile between Stands)

  • 홍완기;이준정
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 1999년도 제3회 압연심포지엄 논문집 압연기술의 미래개척 (Exploitation of Future Rolling Technologies)
    • /
    • pp.27-36
    • /
    • 1999
  • To have high flatness quality of hot rolled strip in the hot strip finishing mill train, a new inter-stand tension profile measuring device of segmented looper roll type(coined as Flatness Sensing Inter-stand Looper, FlatSIL) and a new flatness control system have been developed in this study. The device measures the strip tension profile across the strip width and informs the strip wave pattern to new flatness control system where work roll bending mode to relieve the strip wave is determined. The existing automatic shape control system which uses laser type shape-meter installed at the outlet of the last finishing mill stand strip tension between down coiler and last finishig mill since the latent wave concealed by the strip tension between down coiler and last finishing mill stand cannot be measured by the laser distance-meter. Thus the existing shape control system is not able to control the flatness through the full strip length. The new flatness control system, however, works for full strip length during strip rolling as far as the tension profile measuring device and work roll bender are on. With the new flatness control system, work roll bender is automatically controller to minimize the latent wave of the running strip and the flatness quality as well as strip travelling stability has been noticeably improved from strip head through body to tail.

  • PDF

노후 차량의 배기가스 측정을 이용한 산소센서, 인젝터, 점화2차파형의 파형분석 연구 (A Study on Waveform Analysis of Oxygen Sensor, Injector and Secondary Waveform through Emission Characteristics by a Decrepit Vehicle)

  • 유종식;김철수
    • 한국자동차공학회논문집
    • /
    • 제21권5호
    • /
    • pp.151-156
    • /
    • 2013
  • The experiment was done on cars travelling at the speeds of 20km/h, 60km/h and 100km/h using the performance testing mode for chassis dynamometer. In this experiment, the relativity between the secondary waveform coming from ignition coil and exhaust emissions were measured in case of cars with failures, in oxygen sensor, spark plugs. The following results obtained by analysis of the relativity between the secondary waveform and exhaust emissions. 1) When the oxygen sensor is failure, the average value of CO emission measured was 6.8 times higher than the standard CO emission value and the average value of HC emission measured was 2.3 times higher than the standard emission level. 2) When engine parts are in failure, more fuel enters the cylinder due to longer opening duration of injector, and it tended to make CO and HC emission values increase. 3) Combustion duration, the shape of flame propagation during spark line, and the size of the discharge-induced energy were the three main elements that directly cause variations in CO and HC emission values.

Progressive Collapse of Steel High-Rise Buildings Exposed to Fire: Current State of Research

  • Jiang, Jian;Li, Guo-Qiang
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.375-387
    • /
    • 2018
  • This paper presents a review on progressive collapse mechanism of steel framed buildings exposed to fire. The influence of load ratios, strength of structural members (beam, column, slab, connection), fire scenarios, bracing systems, fire protections on the collapse mode and collapse time of structures is comprehensively reviewed. It is found that the key influencing factors include load ratio, fire scenario, bracing layout and fire protection. The application of strong beams, high load ratios, multi-compartment fires will lead to global downward collapse which is undesirable. The catenary action in beams and tensile membrane action in slabs contribute to the enhancement of structural collapse resistance, leading to a ductile collapse mechanism. It is recommended to increase the reinforcement ratio in the sagging and hogging region of slabs to not only enhance the tensile membrane action in the slab, but to prevent the failure of beam-to-column connections. It is also found that a frame may collapse in the cooling phase of compartment fires or under travelling fires. This is because that the steel members may experience maximum temperatures and maximum displacements under these two fire scenarios. An edge bay fire is more prone to induce the collapse of structures than a central bay fire. The progressive collapse of buildings can be effectively prevented by using bracing systems and fire protections. A combination of horizontal and vertical bracing systems as well as increasing the strength and stiffness of bracing members is recommended to enhance the collapse resistance. A protected frame dose not collapse immediately after the local failure but experiences a relatively long withstanding period of at least 60 mins. It is suggested to use three-dimensional models for accurate predictions of whether, when and how a structure collapses under various fire scenarios.

유한 원통셸의 큰 끝단 종진동을 발생시키는 감쇠파에 대한 분석 연구 (Study on Analysis of Evanescent Waves Generating the Strong End Axial Vibration of a Finite Cylindrical Shell)

  • 길현권
    • 한국음향학회지
    • /
    • 제30권7호
    • /
    • pp.361-367
    • /
    • 2011
  • 진동하는 원통셸에서는 파동의 크기를 유지하며 전파하는 진행파 (굽힘파, 종파, 전단파)와 전파함에 따라서 파동의 크기가 지수 함수적으로 급격히 감쇠하며 소멸되어가는 감쇠파가 발생한다. 감쇠파의 영향은 일반적으로 가진 지점 혹은 구조물의 끝단 지점 부근에 국한되어 작게 발생되게 된다. 그러나 원통셸의 경우 상당히 큰 감쇠파가 발생할 수 있으며, 이러한 감쇠파로 인하여 종진동이 끝단 부근에서 상당히 크게 발생하는 현상이 일어날 수 있다. 이러한 현상은 저자의 유한 원통셸의 종진동 측정 실험 논문에서 관찰되었으며, 본 논문에서는 이러한 큰 감쇠파에 의한 원통셸의 끝단 종진동 현상을 해석적으로 분석하였다. 원통셸의 진동해석을 위하여서는 파동 전파 방법을 활용하였으며, 해석 결과를 실험 결과와 비교함으로써 진동하는 원통셸의 끝단에서 모드 변환 (굽힘파와 감쇠파간의 변환)에 의하여 상당히 큰 감쇠파가 발생할 수 있음을 보였다. 또한 감쇠파의 영향은 원통셸 끝단의 큰 종진동을 발생시키며, 원통셸 전체 길이의 1/3 지점까지도 영향을 줄 수 있음을 보였다.

A Review and Analysis of the Thermal Exposure in Large Compartment Fire Experiments

  • Gupta, Vinny;Hidalgo, Juan P.;Lange, David;Cowlard, Adam;Abecassis-Empis, Cecilia;Torero, Jose L.
    • 국제초고층학회논문집
    • /
    • 제10권4호
    • /
    • pp.345-364
    • /
    • 2021
  • Developments in the understanding of fire behaviour for large open-plan spaces typical of tall buildings have been greatly outpaced by the rate at which these buildings are being constructed and their characteristics changed. Numerous high-profile fire-induced failures have highlighted the inadequacy of existing tools and standards for fire engineering when applied to highly-optimised modern tall buildings. With the continued increase in height and complexity of tall buildings, the risk to the occupants from fire-induced structural collapse increases, thus understanding the performance of complex structural systems under fire exposure is imperative. Therefore, an accurate representation of the design fire for open-plan compartments is required for the purposes of design. This will allow for knowledge-driven, quantifiable factors of safety to be used in the design of highly optimised modern tall buildings. In this paper, we review the state-of-the-art experimental research on large open-plan compartment fires from the past three decades. We have assimilated results collected from 37 large-scale compartment fire experiments of the open-plan type conducted from 1993 to 2019, covering a range of compartment and fuel characteristics. Spatial and temporal distributions of the heat fluxes imposed on compartment ceilings are estimated from the data. The complexity of the compartment fire dynamics is highlighted by the large differences in the data collected, which currently complicates the development of engineering tools based on physical models. Despite the large variability, this analysis shows that the orders of magnitude of the thermal exposure are defined by the ratio of flame spread and burnout front velocities (VS / VBO), which enables the grouping of open-plan compartment fires into three distinct modes of fire spread. Each mode is found to exhibit a characteristic order of magnitude and temporal distribution of thermal exposure. The results show that the magnitude of the thermal exposure for each mode are not consistent with existing performance-based design models, nevertheless, our analysis offers a new pathway for defining thermal exposure from realistic fire scenarios in large open-plan compartments.

차량하중에 의한 사장교의 동적거동에 관한 연구 (A Study on Dynamic Behaviour of Cable-Stayed Bridge by Vehicle Load)

  • 박춘혁;한재익
    • 대한토목학회논문집
    • /
    • 제14권6호
    • /
    • pp.1299-1308
    • /
    • 1994
  • 본 연구는 사장교의 차량하중에 의한 동적거동을 파악하고자 수치해석상 비교적 간단한 일본의 풍리(豊里)(Toyosato)대교(大橋)의 자료를 근거로하여 수치해석 대상모델을 구조형식별로, 여러가지 설계변수-즉, (1) 경간비, (2) 중앙경간장과 주탑높이와의 비, (3) 거어더의 강성, (4) 주탑의 강성, (5) 케이블의 강성-을 변화시켜 수치해석을 수행하여 동적거동을 파악하고, 그 결과를 가지고 설계변수의 영향 및 충격계수의 변화에 대하여 비교 분석하였다. 이때 변위 및 단면력의 영향선을 구하기 위한 해석은 전달행렬법을 이용하였으며, 동적해석에 있어서는 평면구조계의 집중질량계로 모델을 가정하여 차량과 교량의 운동방정식을 유도한 후 모드중첩법을 사용하여 각 질점에 대한 변위 및 단면력의 동적시간이력을 구하였다.

  • PDF