• 제목/요약/키워드: transverse measurements

검색결과 187건 처리시간 0.02초

A Study on Changes to the Upper Body Shape of Elderly Japanese Women -Analysis of the Transverse Plane by Age Group-

  • Oh, Hee-Kyoung
    • 한국의류학회지
    • /
    • 제42권4호
    • /
    • pp.726-736
    • /
    • 2018
  • This study determined how the upper body shape of elderly women changes with age in order to improve the fit of clothing worn by elderly women. Thirty-nine healthy elderly Japanese women had their body measurements taken by measuring tape and a 3D body line scanner (Hamamatsu Model #C9036-02) from December 2011 to March 2012 at a university in Tokyo. It was found that the shoulder line shortens in women between the ages of 70 and 74, but that the upper arm lengthens in women between the ages of 75 and 79. It was also found that the upper part of the scapular area rolls forward in women between the ages of 70 and 74, and that the point of the back which protrudes the most-the lower scapular area-rolls forward in women between the ages of 75 and 79. The results will be helpful for designing clothes for elderly women as their body shape changes with age.

축대칭 하향단 흐름에 대한 실험적 연구 (Experimental Study on the Flow Behind an Axisymmetric Backward-Facing Step)

  • 김경천;부정숙;양종필
    • 대한기계학회논문집
    • /
    • 제18권9호
    • /
    • pp.2463-2476
    • /
    • 1994
  • Local mean fluctuating velocity components were measured in the separating and reattaching axisymmetrc region of turbulent boundary layer over the wall of convex cylinders placed in a water tunnel by using 2-color 4-beam fiber optics laser Doppler velocimetry. Measurements were made with three different diameters of cylinders with four different diameters of cylinders with four different diameter of the obstructions. The range of Reynolds number based on step height was between 5,000 to 25,200. The study demonstrates that the reattachment length decreases with decreasing cylinder radius and is always shorter than that for the two-dimensional backward-facing step flow at the condition of the same step height. It was also observed that the turbulent kinetic energy in the recirculating region increases with an increases in the radius of convex curvature. The measured velocity field suggests that the transverse curvature can effect definitely the formation of corner eddy.

Alternative Description for Gaussian Image Plane

  • Kim, Byongoh;Lee, Sukmock
    • Journal of the Optical Society of Korea
    • /
    • 제19권2호
    • /
    • pp.144-148
    • /
    • 2015
  • An alternative description for the Gaussian image plane (GIP) of an optical system for a given object is presented, which applies to both aberration-free and non-aberration-free systems. We extend the definition of transverse magnification (TM) to the image plane (IP) displaced from the GIP and find that the TM depends linearly on the locations of both an aperture stop placed in front of the system and the IP. Hence, we redefine the GIP as the location at which the slope of the TM variance changes sign. The definition is deterministic and self-consistent and, therefore, no other parameters or measurements are needed. The derivation of this definition using a set of paraxial ray tracings and supporting experimental data for a thick bi-convex lens system is presented.

자연하천에서 오염물질의 횡확산에 관한 수치모형 (Numerical Investigation of Transverse Dispersion in Natural Channels)

  • 서일원;김대근
    • 물과 미래
    • /
    • 제28권5호
    • /
    • pp.151-162
    • /
    • 1995
  • 자연하천에서 오염물질의 횡확산과정은 정확하게 모의하기 위하여 2차원 유관확산모형을 개발하였다. 본 모형에서는 독립변수로서 횡방향거리 대신에 횡방향누가유량을 도입하였고, 하천의 주흐름을 따라 좌표축을 설정하는 자연좌표계를 사용하였다. 유도한 유관확산방정식을 풀기 위한 수치방법으로서 Eulerian-Lagrangian method를 이용하였다. 유관확산방정식을 연산자분리방법을 이용하여 이송을 지배하는 방정식과 확산을 지배하는 방정식으로 분리하였다. 그리고 이송방정식은 Eulerian 계산격자상에서 특성곡선법을 이용하였고 확산방정식은 중앙차분법을 이용하여 수치모의 하였다. 본 연구에서는 이송방정식의 풀이에서 사용되는 보간다항식으로 cubic spline 보간다항식을 이용하였다. 본 연구에서 개발한 모형을 적용하여 실제 자연하천에서 행해진 정상상태의 색소실험 결과를 모의한 결과개발된 모형이 우수한 거동을 보이고 있음이 밝혀졌다.

  • PDF

Electron Beam Coherency Determined from Interferograms of Carbon Nanotubes

  • Cho, B.;Oshima, C.
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권3호
    • /
    • pp.892-898
    • /
    • 2013
  • A field emission projection microscope was constructed to investigate the atomic and chemical-bonding structure of molecules using electron in-line holography. Fringes of carbon nanotube images were found to be interferograms equivalent to those created by the electron biprism in conventional electron microscopy. By exploiting carbon nanotubes as the filament of the electron biprism, we measured the transverse coherence length of the electron beam from tungsten field emitters. The measurements revealed that a partially coherent electron-beam was emitted from a finite area.

경부고속도로와 88고속도로에 대한 트럭수송시의 진동 특성 측정 및 분석 연구 (Measurements and Analysis of Truck Transport Vibration Characteristics on the Gyungbu and 88 Highway)

  • 박인식
    • 한국포장학회지
    • /
    • 제12권1호
    • /
    • pp.21-25
    • /
    • 2006
  • Measurements of accelerometer levels transmitted from the floor in commercials truck shipments were carried out transportation of 300 Kg-load from Gyungbu Highway(Waegouan-Seoul) to 88 Highway(Gwangju-Daegu). Different characteristics were observed the values measured the vibration levels with directions in the two Highway's as a function of road condition and truck speed. The results showed that the vibration levels of the Gyungbu Highway is much higher than those of the 88 Highway. A following analysis on the obtained values was used to get the acceleration spectral density (ASD) and power spectral density (PSD). For the entire transit route, the results showed that the level of vibration to vertical direction was significant effects for damaging the products carried compared to other directions such as longitudinal and transverse. This paper provides an updated history of measured characteristics of vibration levels for highways using mainly in domestic area.

  • PDF

Convection Effects on PGSE-NMR Self-Diffusion Measurements at Low Temperature: Investigation into Sources of Induced Convective Flows

  • Chung, Kee-Choo;Yu, Hyo-Yeon;Ahn, Sang-Doo
    • Bulletin of the Korean Chemical Society
    • /
    • 제32권6호
    • /
    • pp.1970-1974
    • /
    • 2011
  • The effects of convection on the measurement of the diffusion coefficients of liquids by the pulsed gradient spin echo (PGSE) NMR method at low temperature are discussed. To examine the generation of convective flows, we used four different types of sample tubes in the diffusion measurements with temperature variation; a normal 5 mm NMR tube, a Shigemi tube, an ELISE type tube, and a capillary tube. Below room temperature, the calculated diffusion coefficients of chloroform in 5 mm o.d. type tubes increased with decreasing temperature, while those in the capillary tube decreased linearly. The convective flow was found to be significant even at low temperature and it seemed to be mainly induced by the transverse temperature gradient. It was also found that the capillary tube was most appropriate to measure the diffusion coefficients, since its small diameter is effective in suppressing the convective flows at both high and low temperatures.

Cephalometric Angular Measurements of the Mandible Using Three-Dimensional Computed Tomography Scans in Koreans

  • Kim, Yong Hyun;Kang, Seok Joo;Sun, Hook
    • Archives of Plastic Surgery
    • /
    • 제43권1호
    • /
    • pp.32-37
    • /
    • 2016
  • Background We conducted this study to analyze the values of the key cephalometric angular measurements of the mandible using 3-dimensional (3D) computed tomography scans. Methods In the 106 enrolled patients, a 3D cephalometric analysis was performed to measure the angular variables of the mandible. These values were compared between the two sides and between the two sexes. Results The frontal measurements revealed that the mandibular body curve angle was larger on the left (Lt) side (right [Rt], $141.24{\pm}7.54$; Lt, $142.68{\pm}6.94$; P=0.002) and the gonial angle was larger on the right side (Rt, $134.37{\pm}8.44$; Lt, $131.54{\pm}7.14$; P<0.001). The sagittal measurements showed that the gonial angle was larger on the right side (Rt, $134.37{\pm}8.44$; Lt, $131.54{\pm}7.14$; P>0.05). Further, the transverse measurements revealed that the mandibular body curve angle was larger on the right side (Rt, $140.28{\pm}7.05$; Lt, $137.56{\pm}6.23$; P<0.001). Conclusions These results provide an average of the mandibular angular measurements for the Korean population, establishing a standard for determining surgical patient groups and outcome evaluations in the field of mandible contour surgery.

Use of an anatomical mid-sagittal plane for 3-dimensional cephalometry: A preliminary study

  • Vernucci, Roberto Antonio;Aghazada, Huseynagha;Gardini, Kelly;Fegatelli, Danilo Alunni;Barbato, Ersilia;Galluccio, Gabriella;Silvestri, Alessandro
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.159-169
    • /
    • 2019
  • Purpose: Cone-beam computed tomography (CBCT) is widely used for 3-dimensional assessments of cranio-maxillo-facial relationships, especially in patients undergoing orthognathic surgery. We have introduced, for reference in CBCT cephalometry, an anatomical mid-sagittal plane (MSP) identified by the nasion, the midpoint between the posterior clinoid processes of the sella turcica, and the basion. The MSP is an updated version of the median plane previously used at our institution for 2D posterior-anterior cephalometry. This study was conducted to test the accuracy of the CBCT measures compared to those obtained using standard posterior-anterior cephalometry. Materials and Methods: Two operators measured the inter-zygomatic distance on 15 CBCT scans using the MSP as a reference plane, and the CBCT measurements were compared with measurements made on patients' posterior-anterior cephalograms. The statistical analysis evaluated the absolute and percentage differences between the 3D and 2D measurements. Results: As demonstrated by the absolute mean difference (roughly 1 mm) and the percentage difference (less than 3%), the MSP showed good accuracy on CBCT compared to the 2D plane, especially for measurements of the left side. However, the CBCT measurements showed a high standard deviation, indicating major variability and low precision. Conclusion: The anatomical MSP can be used as a reliable reference plane for transverse measurements in 3D cephalometry in cases of symmetrical or asymmetrical malocclusion. In patients who suffer from distortions of the skull base, the identification of landmarks might be difficult and the MSP could be unreliable. Becoming familiar with the relevant software could reduce errors and improve reliability.

3D-CT를 이용한 흉추의 극돌기와 횡돌기 사이의 관계에 대한 연구 (Studies about Anatomical Relationships between the spinous and transverse processes of the thoracic spine using 3D-CT)

  • 금지혜;백동기;고현일;하원배;이정한
    • 척추신경추나의학회지
    • /
    • 제14권2호
    • /
    • pp.135-146
    • /
    • 2019
  • Objectives : There are many theories about the anatomical relationships between the thoracic spinous and transverse processes. However, these studies were all conducted on cadavers. Thus, there might be differences when applied to living individuals. Therefore, the aim of this study was to determine whether the theories were similar when measured in living individuals. Methods : We conducted studies with 10 individuals aged 20-30 using 3D-CT. Four different measurements were taken between the thoracic spinous and transverse processes. To facilitate the relationship analysis, the spinous process positioned between the traverse process of the segment and the lower segment was set to 0.5. The spinous process located at the height of the traverse process of the lower segment was set to 1. The spinous process located between the traverse process of the lower segment and the two segments below was set to 1.5. Results : Therefore, based on the aforementioned settings, T1-T4 were 1, T5-T7 were 1.5, T8-T10 were 1, and T11 and T12 were 0.5. This indicated that the spinous processes of T1-T4 and T8-T10 were equal in height to the transverse processes of the lower segment, and that T5-T7 were at the midpoint of the height of the transverse processes between the lower segment and two segments below, and T11, T12 corresponded to the midpoint between the traverse process of the segment and the lower segment. Conclusions : Neither 'Geelhoed's rule'nor 'the rule of three'was accurate when applied to living individuals. However, this study had some limitations, so further research is needed.