• Title/Summary/Keyword: transmission zero

Search Result 330, Processing Time 0.027 seconds

The Reduction Properties of Nitrate in Water with Palladium and Indium on Aluminum Pillared Montmorillonite Catalyst (팔라디움과 인디움을 담지한 Al 층간가교 몬모릴로나이트 촉매의 수중 질산성질소 환원 특성)

  • Jeong, Sangjo
    • Journal of Korean Society on Water Environment
    • /
    • v.34 no.6
    • /
    • pp.621-631
    • /
    • 2018
  • In this study, catalyst was made through incipient wetness method using palladium (Pd) as noble metal, indium (In) as secondary metal, and montmorillonite (MK10) and Al pillared montmorillonite (Al-MK10) as supporters. The nitrate reduction rate of the catalysts was measured by batch experiments where H2 gas was used as reducing agent and formic acid as pH controller. Transmission electron microscopy (TEM) equipped with energy dispersive spectroscopy (EDS) and X-ray photoelectron spectroscopy (XPS) were all used to determine the elemental distribution of Pd, In, Al, and Si on catalysts. It was observed that Al pillaring increased the Al/Si elemental composition ratio and point of zero charge of MK10, but decreased its BET specific surface area and pore volume. The nitrate reduction rate of Al-MK10 Pd/In was 2.0 ~ 2.5 times higher than that of MK10 Pd/In using artificial groundwater (GW) in ambient temperature and pressure. Nitrate reduction rates in GW were 1.2 ~ 1.7 times lower than those in distilled deionized water (DDW). Nitrate reduction rates in acidic conditions were higher than those in neutral condition in both GW and DDW. The amount of produced NH3-N over degraded NO3- at acid conditions was lower than that of neutral condition. Even though the leaching of Pd after reaction was measured in DDW it was not detected when both Al-MK10 Pd/In and MK10 Pd/In were used in GW. The modification of montmorillonite as a supporter significantly increased the reductive catalytic activities of nitrates. However, the ratio of producing ammonia by-products to degraded nitrates in ambient temperature and pressure was similar.

Spatial Correlation-based Resource Sharing in Cognitive Radio SWIPT Networks

  • Rong, Mei;Liang, Zhonghua
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.9
    • /
    • pp.3172-3193
    • /
    • 2022
  • Cognitive radio-simultaneous wireless information and power transfer (CR-SWIPT) has attracted much interest since it can improve both the spectrum and energy efficiency of wireless networks. This paper focuses on the resource sharing between a point-to-point primary system (PRS) and a multiuser multi-antenna cellular cognitive radio system (CRS) containing a large number of cognitive users (CUs). The resource sharing optimization problem is formulated by jointly scheduling CUs and adjusting the transmit power at the cognitive base station (CBS). The effect of accessing CUs' spatial channel correlation on the possible transmit power of the CBS is investigated. Accordingly, we provide a low-complexity suboptimal approach termed the semi-correlated semi-orthogonal user selection (SC-SOUS) algorithm to enhance the spectrum efficiency. In the proposed algorithm, CUs that are highly correlated to the information decoding primary receiver (IPR) and mutually near orthogonal are selected for simultaneous transmission to reduce the interference to the IPR and increase the sum rate of the CRS. We further develop a spatial correlation-based resource sharing (SC-RS) strategy to improve energy sharing performance. CUs nearly orthogonal to the energy harvesting primary receiver (EPR) are chosen as candidates for user selection. Therefore, the EPR can harvest more energy from the CBS so that the energy utilization of the network can improve. Besides, zero-forcing precoding and power control are adopted to eliminate interference within the CRS and meet the transmit power constraints. Simulation results and analysis show that, compared with the existing CU selection methods, the proposed low-complex strategy can enhance both the achievable sum rate of the CRS and the energy sharing capability of the network.

Fuel cell based CHP technologies for residential sector (연료전지와 마이크로 열병합 발전기술)

  • Son, Young Mok
    • Journal of Energy Engineering
    • /
    • v.25 no.4
    • /
    • pp.251-258
    • /
    • 2016
  • This article reports current status of micro fuel cell-combined heat and power (${\mu}FC$-CHP) systems which utilize both power and heat generated by fuel cells. There are several options for constructing CHP systems and among them, fuel cells are the most useful and their total energy efficiency combining heat and power can reach up to about 90%. Fuel cells are classified as five types based on the electrolyte, but the most suitable fuel cell types for the ${\mu}FC$-CHP system are proton exchange membrane fuel cells (PEMFCs) and solid oxide fuel cells (SOFCs). ${\mu}FC$-CHP systems have several advantages such as decrease of the transmission-distribution loss, reduced costs of electricity due to distributed power generation, and environmental-friendliness owing to zero emission. The main drawback of the ${\mu}FC$-CHP systems is the high initial investment, however, it keeps decreasing as the technology development reduces production costs. Currently, Japan is the most leading country of the ${\mu}FC$-CHP market, however, Korea tries to expand the market by planning the deployment of 1 million units of ${\mu}FC$-CHP systems and governmental subsidiary supporting of half of the install price. In this report, integration technologies for connecting FC and CHP, and technology trends of leading countries are presented as well.

Design of an Offset Interdigital Filter Based on Multi-Port EM Simulated Y-Parameters (EM 시뮬레이션 기반 다중 포트 Y-파라미터를 이용한 변위된 인터디지털 여파기 설계)

  • Lee, Seok-Jeong;Oh, Hyun-Seok;Jeong, Hae-Chang;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.22 no.7
    • /
    • pp.694-704
    • /
    • 2011
  • In this paper, we present a design of a 5th order Chebyshev interdigital band-pass filter using inverter and susceptance slope parameter values obtained from EM simulated multi-port Y-parameters. The shifted length of the resonator is determined when the frequency of the transmission zero is separated far away from the center frequency. For the initial dimensions of the interdigital filter, the filter is decomposed into the individual resonators, and the dimensions are obtained using EM Simulation of the decomposed resonators. However, the interdigital filter with the dimensions determined from the EM simulation of the decomposed resonators shows slightly distorted response from the desired frequency response due to the coupling between non-adjacent resonators. To obtain a EM simulation dataset, EM simulation for this filter is carried out by parameter sweep with constant ratio for the initial values. In this dataset, it is determined the final values for the filter by optimization. The fabricated filter by PCB shows an upper-shift of center frequency of about 70 MHz, which was caused by permittivity changed and tolerance of fabrication.

Effects of Diltiazem on Isoproterenol-induced Myocardial Cell Wounding in the Rabbit (Isoproterenol 투여로 유발된 심근세포 손상에 미치는 diltiazem의 영향)

  • Kim, Hyun;Chang, Dae-Yung;Rah, Bpng-Jin;Kim, Ho-Dirk
    • Applied Microscopy
    • /
    • v.27 no.2
    • /
    • pp.121-130
    • /
    • 1997
  • It has been demonstrated that majority of cells in the mammalian body such as myocytes and epithelial cells of skin and intestine respond to mechanical force or environmental factors and exhibit partial disruption of cell membrane, i. e., cell wounding, even in a physiological condition. Myocardial cells are rather apt to be wounded than other cells since they are definitely exposed to mechanical stress by contraction-relaxation and blood flow. However, the mechanism how myocardial cells protect themselves against cell wounding is not yet clarified. On this background, the present study was performed to elucidate whether albumin leakage is related to cell wounding and to assess whether diltiazem, a potent calcium channel blocker, is beneficial in isoproterenol-induced cell wounding in the heart. Hearts isolated from New Zealand White rabbits ($1.5\sim2.0kg$ body weight, n=20) were perfused with Tyrode solution by Langendorff technique. After stabilization of baseline hemodynamics, the hearts were subjected to bolus administration of isoproterenol and diltiazem as following order: $1.6{\mu}M$ isoproterenol at zero min (the beginning point): $16{\mu}M$ diltiazem at 20min; $1.6{\mu}M$ isoproterenol at 25min; $16{\mu}M$ isoproterenol at 45 min; $160{\mu}M$ diltiazem at 65 min; $16{\mu}M$ isoproterenol at 70 min. During all experiments, the left ventricular function was recorded, albumin leakage in the coronary effluents was analyzed by electrophoresis and Western blot, and myocardial cell membranes were examined by conventional transmission electron microscopy. Data were analyzed by t-test and linear regression test. Isoproterenol significantly increased the inotropic and chronotropic contractions, coronary flow, and frequency of arrhythmia, however, diltiazem did not influence on hemodynamics except decrease in the frequency of arrhythmia and a slight decrease in contractility. Isoproterenol also resulted partial disruption of myocardial cell membrane and inclose in albumin leakage, while diltiazem pretreatment showed number of electron-dense plaques in the cell membrane and a tendency of decrease in albumin leakage. These results indicate that albumin leakage may be an indirect index of cell wounding in the heart and diltiazem nay be beneficial to protect myocardial cells against isoproterenol-induced cell wounding. It is likely that diltiazem promotes resealing process of the cell membrane.

  • PDF

Adherence Rates of Salmonella Typhimurium and Salmonella spp. in Pork Meat Contaminated during Processing (포장돈육 중 Salmonella Typhimurium과 Salmonella spp.에 오염된 돈육으로부터 식품과 식품접촉면으로의 오염 부착율)

  • Kim, Seong-Jo;Bahk, Gyung-Jin;Ding, Tian;Kim, Tae-Woong;Oh, Deog-Hwan
    • Korean Journal of Food Science and Technology
    • /
    • v.40 no.3
    • /
    • pp.349-353
    • /
    • 2008
  • This study was performed to determine the adherence rates of standard type Salmonella Typhimurium (ST) and wild type Salmonella spp.(WT) in pork after the following contact types and times at $10^{\circ}C$: pork meat (2, 6, 24 hr), conveyer belt (2, 6 hr), stainless steel (2, 6 hr), and cutting board (2, 6 hr). After 6 hr of pork meat to meat fat contact, the adherence rates for ST and WT were approximately 4.21 and 26.87%, respectively, and after 6 hrs of pork meat to red meat contact they were 16.40 and 27.48%, respectively. However, after 24 hr of both types of contact, ST and WT showed 100% adherence rates. The adherence rates for ST after 2 hr and 6 hr of pork meat to conveyer belt contact were 1.34 and 0.60%, respectively, while the adherence rate for WT was 5.14% after 6 hr of contact. After pork meat to stainless steel contact, ST showed adherence rates of zero and 1.59% after 6 and 24 hr of contact, respectively, while the adherence rates for WT ranged from 0.17% after 2 hr to 5.01% after 6 hr. On the other hand, neither ST nor WT offered adherence data following pork meat to cutting board contact. These results suggest that the adherence rates of ST and WT after pork meat to pork meat contact or pork meat to processing surface contact were significantly affected by the contact time and WT presented much higher adherence rates for both types of transmission than ST.

Equalization Digital On-Channel Repeater Part 1 : Laboratory Test Results (등화형 디지털 동일 채널 중계기 Part 1 : 실험실 테스트 결과)

  • Park Sung Ik;Lee Yong-Tae;Eum Homin;Seo Jae Hyun;Kim Heung Mook;Kim Seung Won;Lee Soo-In
    • Journal of Broadcast Engineering
    • /
    • v.10 no.2
    • /
    • pp.210-220
    • /
    • 2005
  • This paper presents and analyzes laboratory test results of Equalization Digital On-Channel Repeater (EDOCR) using ATSC(Advanced Television Systems Committee) terrestrial digital TV broadcasting system. The EDOCR laboratory test, which is done at CRC(Communications Research Centre) Canada, is classified to receiver test, transmitter test, and synchronization test between transmission and reception frequencies. The receiver part includes feedback signal, random noise, single echo, multi-path ensemble, and NTSC/DTV interference test. The transmitter part includes out-of channel emission, quality of transmitting signal, and phase noise test. By the field test results, the receiver part of the EDOCR eliminates average 5.5 dB of feedback or single echo signal in range of 0 to 11 ${\mu}s$ and has average 18.6 dB at TOV(Threshold of Visibility) under random noise environment. Also, the transmitter part of the EDOCR satisfies the specification of US FCC(Federal Communications Commission), and frequency difference between transmitter and receiver is zero.

Effective Detective Quantum Efficiency (eDQE) Evaluation for the Influence of Focal Spot Size and Magnification on the Digital Radiography System (X-선관 초점 크기와 확대도에 따른 디지털 일반촬영 시스템의 유효검출양자효율 평가)

  • Kim, Ye-Seul;Park, Hye-Suk;Park, Su-Jin;Kim, Hee-Joung
    • Progress in Medical Physics
    • /
    • v.23 no.1
    • /
    • pp.26-32
    • /
    • 2012
  • The magnification technique has recently become popular in bone radiography, mammography and other diagnostic examination. However, because of the finite size of X-ray focal spot, the magnification influences various imaging properties with resolution, noise and contrast. The purpose of study is to investigate the influence of magnification and focal spot size on digital imaging system using eDQE (effective detective quantum efficiency). Effective DQE is a metric reflecting overall system response including focal spot blur, magnification, scatter and grid response. The adult chest phantom employed in the Food and Drug Administration (FDA) was used to derive eDQE from eMTF (effective modulation transfer function), eNPS (effective noise power spectrum), scatter fraction and transmission fraction. According to results, spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.76, 2.21, 1.78, 1.49 and 1.26 lp/mm respectively using small focal spot. The spatial frequencies that eMTF is 10% with the magnification factor of 1.2, 1.4, 1.6, 1.8 and 2.0 are 2.21, 1.66, 1.25, 0.93 and 0.73 lp/mm respectively using large focal spot. The eMTFs and eDQEs decreases with increasing magnification factor. Although there are no significant differences with focal spot size on eDQE (0), the eDQEs drops more sharply with large focal spot than small focal spot. The magnification imaging can enlarge the small size lesion and improve the contrast due to decrease of effective noise and scatter with air-gap effect. The enlargement of the image size can be helpful for visual detection of small image. However, focal spot blurring caused by finite size of focal spot shows more significant impact on spatial resolution than the improvement of other metrics resulted by magnification effect. Based on these results, appropriate magnification factor and focal spot size should be established to perform magnification imaging with digital radiography system.

A development of DS/CDMA MODEM architecture and its implementation (DS/CDMA 모뎀 구조와 ASIC Chip Set 개발)

  • 김제우;박종현;김석중;심복태;이홍직
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.22 no.6
    • /
    • pp.1210-1230
    • /
    • 1997
  • In this paper, we suggest an architecture of DS/CDMA tranceiver composed of one pilot channel used as reference and multiple traffic channels. The pilot channel-an unmodulated PN code-is used as the reference signal for synchronization of PN code and data demondulation. The coherent demodulation architecture is also exploited for the reverse link as well as for the forward link. Here are the characteristics of the suggested DS/CDMA system. First, we suggest an interlaced quadrature spreading(IQS) method. In this method, the PN coe for I-phase 1st channel is used for Q-phase 2nd channels and the PN code for Q-phase 1st channel is used for I-phase 2nd channel, and so on-which is quite different from the eisting spreading schemes of DS/CDMA systems, such as IS-95 digital CDMA cellular or W-CDMA for PCS. By doing IQS spreading, we can drastically reduce the zero crossing rate of the RF signals. Second, we introduce an adaptive threshold setting for the synchronization of PN code, an initial acquistion method that uses a single PN code generator and reduces the acquistion time by a half compared the existing ones, and exploit the state machines to reduce the reacquistion time Third, various kinds of functions, such as automatic frequency control(AFC), automatic level control(ALC), bit-error-rate(BER) estimator, and spectral shaping for reducing the adjacent channel interference, are introduced to improve the system performance. Fourth, we designed and implemented the DS/CDMA MODEM to be used for variable transmission rate applications-from 16Kbps to 1.024Mbps. We developed and confirmed the DS/CDMA MODEM architecture through mathematical analysis and various kind of simulations. The ASIC design was done using VHDL coding and synthesis. To cope with several different kinds of applications, we developed transmitter and receiver ASICs separately. While a single transmitter or receiver ASC contains three channels (one for the pilot and the others for the traffic channels), by combining several transmitter ASICs, we can expand the number of channels up to 64. The ASICs are now under use for implementing a line-of-sight (LOS) radio equipment.

  • PDF

Recent Variations of UV Irradiance at Seoul 2004~2010 (서울의 최근 자외선 복사의 변화 2004~2010)

  • Kim, Jhoon;Park, Sang Seo;Cho, Nayeong;Kim, Woogyung;Cho, Hi Ku
    • Atmosphere
    • /
    • v.21 no.4
    • /
    • pp.429-438
    • /
    • 2011
  • The climatology of surface UV radiation for Seoul, presented in Cho et al. (1998; 2001), has been updated using measurement of surface erythemal ultraviolet (EUV) and total ultraviolet (TUV) irradiance (wavelength 286.5~363.0 nm) by a Brewer Spectrophotometer (MK-IV) for the period 2004~2010. The analysis was also carried out together with the broadband total (global) solar irradiance (TR ; 305~2800 nm) and cloud amount to compare with the UV variations, measured by Seoul meteorological station of Korean Meteorological Agency located near the present study site. Under all-sky conditions, the day-to-day variability of EUV exhibits annual mean of 98% in increase and 31% in decrease. It has been also shown that the EUV variability is 17 times as high as the total ozone in positive change, whereas this is 6 times higher in negative change. Thus, the day to day variability is dominantly caused rather by the daily synoptic situations than by the ozone variability. Annual mean value of daily EUV and TUV shows $1.62kJm^{-2}$ and $0.63MJm^{-2}$ respectively, whereas mean value of TR is $12.4MJm^{-2}$ ($143.1Wm^{-2}$). The yearly maximum in noon-time UV Index (UVI) varies between 9 and 11 depending on time of year. The highest UVI shows 11 on 20 July, 2008 during the period 2004~2010, but for the period 1994~2000, the index of 12 was recorded on 13 July, 1994 (Cho et al., 2001). A 40% of daily maximum UVI belongs to "low (UVI < 2)", whereas the UVI less than 5% of the maximum show "very high (8 < UVI < 10)". On average, the maximum UVI exceeded 8 on 9 days per year. The values of Tropospheric Emission Monitoring Internet Service (TEMIS) EUV and UVI under cloud-free conditions are 1.8 times and 1.5 times, respectively, higher than the all-sky measurements by the Brewer. The trend analysis in fractional deviation of monthly UV from the reference value shows a decrease of -0.83% and -0.90% $decade^{-1}$ in the EUV and TUV, respectively, whereas the TR trend is near zero (+0.11% $decade^{-1}$). The trend is statistically significant except for TR trend (p = 0.279). It is possible that the recent UV decrease is mainly associated with increase in total ozone, but the trend in TR can be attributed to the other parameters such as clouds except the ozone. Certainly, the cloud effects suggest that the reason for the differences between UV and TR trends can be explained. In order to estimate cloud effects, the EUV, TUV and TR irradiances have been also evaluated for clear skies (cloud cover < 25%) and cloudy skies (cloud cover ${\geq}$ 75%). Annual mean values show that EUV, TUV and TR are $2.15kJm^{-2}$, $0.83MJm^{-2}$, and $17.9MJm^{-2}$ for clear skies, and $1.24kJm^{-2}$, $0.46MJm^{-2}$, and $7.2MJm^{-2}$ for cloudy skies, respectively. As results, the transmission of radiation through clouds under cloudy-sky conditions is observed to be 58%, 55% and 40% for EUV, TUV and TR, respectively. Consequently, it is clear that the cloud effects on EUV and TUV are 18% and 15%, respectively lower than the effects on TR under cloudy-sky conditions. Clouds under all-sky conditions (average of cloud cover is 5 tenths) reduced the EUV and TUV to about 25% of the clear-sky (cloud cover < 25%) values, whereas for TR, this was 31%. As a result, it is noted that the UV radiation is attenuated less than TR by clouds under all weather conditions.