• 제목/요약/키워드: transmission power

검색결과 5,783건 처리시간 0.039초

A New Maximum Inductive Power Transmission Capacity Tracking Method

  • Ameri, Mohammad Hassan;Varjani, Ali Yazdian;Mohamadian, Mustafa
    • Journal of Power Electronics
    • /
    • 제16권6호
    • /
    • pp.2202-2211
    • /
    • 2016
  • In certain applications, such as IPT-based EV charger (IPTEC), any variation in alignment and distance between pickup and charger primary leads to a change in leakage and magnetic impedance magnitudes. The power transmission capacity is not always at the maximum level because of these variations. This study proposes a new low-cost tracking method that achieves the Maximum Inductive Power Transmission Capacity (MIPTC). Furthermore, in the proposed method, the exchange of information between load and source is not required. For an application such as IPTEC, the load detected by the IPTEC varies continuously with time because of the change in state of the charge. This load variation causes a significant variation in IPT resonant circuit voltage gain. However, the optimized charging output voltage should be kept constant. From the analysis of the behavior of the IPT circuit at different working frequencies and load conditions, a MIPTC operation point that is independent of load condition can be identified. Finally, the experimental results of a developed prototype IPT circuit test show the performance of the proposed method.

Equivalent Transmission-Line Sections for Very High Impedances and Their Application to Branch-Line Hybrids with Very Weak Coupling Power

  • Ahn, Hee-Ran;Kim, Bum-Man
    • Journal of electromagnetic engineering and science
    • /
    • 제9권2호
    • /
    • pp.85-97
    • /
    • 2009
  • As operating frequency is raised and as more integration with active and passive elements is required, it becomes difficult to fabricate more than 120 ${\Omega}$ characteristic impedance of a mierostrip line. To solve this problem, an equivalent high impedance transmission-line section is suggested, which consists mainly of a pair of coupled-line sections with two shorts. However, it becomes a transmission-line section only when its electrical length is fixed and its coupling power is more than half. To have transmission-line characteristics(perfect matching), independently of coupling power and electrical length, two identical open stubs are added and conventional design equations of evenand odd-mode impedances are modified, based on the fact that the modified design equations have the linear combinations of conventional ones. The high impedance transmission-line section is a passive component and therefore should be perfectly matched, at least at a design center frequency. For this, two different solutions are derived for the added open stub and two types of high impedance transmission-line sections with 160 ${\Omega}$ characteristic impedance are simulated as the electrical lengths of the coupled-line sections are varied. The simulation results show that the determination of the available bandwidth location depends on which solution is chosen. As an application, branch-line hybrids with very weak coupling power are investigated, depending on where an isolated port is located, and two types of branch-line hybrids are derived for each case. To verify the derived branch-line hybrids, a microstrip branch-line hybrid with -15 dB coupling power, composed of two 90$^{\circ}$ and two 270$^{\circ}$ transmission-line sections, is fabricated on a substrate of ${\varepsilon}_r$= 3.4 and h=0.76 mm and measured. In this case, 276.7 ${\Omega}$ characteristic impedance is fabricated using the suggested high impedance transmission-line sections. The measured coupling power is -14.5 dB, isolation and matching is almost perfect at a design center frequency of 2 GHz, showing good agreement with the prediction.

ICT 기반의 무선전력전송 시스템 개발 (ICT based Wireless Power Transmission System Development)

  • 이종희;방준호;천현준;서범근;유인호
    • 한국산학기술학회논문지
    • /
    • 제17권5호
    • /
    • pp.67-73
    • /
    • 2016
  • 최근 들어 전 세계적으로 무선전력전송이 많이 연구되고 있다. 무선 전력전송이란 전기기기가 전선이 없어도 무선으로 전력을 공급하는 기술이다. 본 논문에서는 ICT 기반의 무선전력전송 시스템을 설계, 제작하였다. 제안된 시스템은 기존 시스템보다 픽업코일에 접촉는 면적을 증대하여 같은 L값과 C값을 사용해도 효율이 높아질 수 있도록 설계하였다. 무선 전송의 송 수신부와 고효율의 코일부로 구성되어 있으며, 시스템의 전송 효율을 높이는 방법을 제안하였다. 특히 무선 송 수신부는 ICT 기술과 연동이 가능하도록 설계하여 실시간 원격 모니터링이 가능하도록 제작하였고, 대기전력을 절감하는 효과를 연구하였다. 이를 위하여 기업에서 무선전력전송 시스템에 사용된 IGBT소자의 최대 주파수 20[KHz]를 사용하여 이에 가장 적절한 L, C값을 찾기 위해 많은 필드실험을 통하여 가장 효율적인 L값 $23.9[{\mu}H]$, C값 $2.64[{\mu}F]$을 선정하여 시스템을 구성하였다. 또한 대기전력을 감소하기 위해 출력전류를 제어하는 알고리즘을 설계하여 적용하였다. 이 결과 기존의 장비보다 무선전력전송용량과 효율이 75[%]에서 80[%]로 전력전송 유효거리를 10[%] 증가하여 대기전력의 감소 및 유지보수 비용이 절감하였고, ICT 기술을 이용한 무선 송수신부 와 프로그램을 개발하여 사용자가 취득된 데이터로 시스템의 고장 검출을 쉽게 할 수 있게 하였다.

Power Reflection and Transmission Coefficients for Meander-Line Polarizers with a Chiral Slab

  • Delihacioglu, Kemal;Uckun, Savas
    • ETRI Journal
    • /
    • 제25권1호
    • /
    • pp.41-48
    • /
    • 2003
  • This paper presents a theoretical investigation of power reflection and transmission coefficients for a meander-line polarizer placed periodically on a chiral slab. It is assumed that a linearly polarized transverse magnetic wave is incident on a chiral slab from the air region. In the analysis, we derive the electric and magnetic fields in the modal form in the air and chiral regions. We obtain power reflection and transmission coefficients in a straightforward manner after matching the tangential components of the electric and magnetic fields at the boundaries. We present numerical results for the power reflection and transmission coefficients versus frequency and incident angle for different values of the chirality admittance. A meander-line polarizer placed on a dielectric slab can convert a linearly polarized wave to a circularly polarized wave. The design parameters for a meander-line polarizer are the dimensions of the meander-line and the values of the dielectric slab. Replacing a dielectric slab with a chiral slab introduces a new independent parameter which controls the wave polarization.

  • PDF

A Case Study of Resolving Conflict in Energy Infrastructure Siting by the Solar PV Project

  • Lee, Jonghwan;Shin, Dong-hwi;Han, Soohee;Roh, Jae Hyung
    • Current Photovoltaic Research
    • /
    • 제8권3호
    • /
    • pp.79-85
    • /
    • 2020
  • The growing demand for new energy infrastructure has often been encountered with the difficulties of siting in power plants and electric transmission lines. Siting such large-scale and complex facilities produces so many-sided issues that it is highly necessary to develop an approach to resolving the related problems and conflicts. This paper introduces how the stakeholders have handled the issues and resolved conflicts with residents opposed the construction of 765 kV transmission line. The solar photovoltaic power generation, called "Hee-Mang Sunlight Power project", is used for persuading residents to agree with constructing high-voltage transmission line and sharing benefits. It is considered how the project performance such as generation output and resident's profits is and proposed what the project should be revised and supplement. The project is shown that the intractable spiting in energy systems can be smartly resolved with cost-effective institutional solutions instead of relatively expensive technical ones.

Geometric structure and electronic behavior of Rh decorating effect on zigzag CNTs (n=7-12): A DFT study

  • Cui, Hao;Zhang, Xiaoxing;Zhou, Yongjian;Zhang, Jun
    • Carbon letters
    • /
    • 제26권
    • /
    • pp.61-65
    • /
    • 2018
  • Comprehensive calculations of the Rh decoration effect on zigzag CNTs with n ranging from 7 to 12 were conducted in this work to understand the effect of Rh doping on geometric structures and electronic behaviors upon metallic and semiconducting CNTs. The obtained results indicated that Rh dopant not only contributes to the deformation of C-C bonds on the sidewall of CNTs, but also transforms the electron distribution of related complexes, thereby leading to a remarkable increase of the conductivity of pure CNTs given the emerged novel state within the energy gap for metallic CNTs and the narrowed energy gap for semiconducting CNTs. Our calculations will be meaningful for exploiting novel CNT-based materials with better sensitivity to electrons and higher electrical conductivity compared with pure CNTs.

동일 평면상에서 연성된 직사각형 평판의 진동파워흐름해석 (Vibration Power Flow Analysis of Coupled Co-planar Rectangular Plates)

  • 박도현;홍석윤;길현권
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1053-1061
    • /
    • 1998
  • In this paper. the power flow analysis(PFA) method is applied to the prediction of the vibrational energy density and intensity of coupled co-planar plates. To cover the energy transmission and reflection at the joint of the plates. the wave transmission approach is Introduced with the assumption that all the incident waves are normal to the joint. By changing the frequency ranges and internal loss factors. we have obtained the reliable PFA results. and compared them with the analytical exact solutions.

  • PDF

암반 앵커기초로 시공된 송전철탑 구조물의 거동특성에 관한 연구 (Behavior of Electric Transmission Tower with Rock Anchor Foundation)

  • 김경열;홍성연;이대수
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2010년도 추계 학술발표회
    • /
    • pp.605-614
    • /
    • 2010
  • In this paper, the initial behavior of transmission tower was analyzed. This tower was firstly constructed by rock anchor foundation in domestic 154 kV transmission line and wireless real-time monitoring system was installed to obtain the measured data for analysis of the structure behavior. For this purpose, 16 strain gauges was installed in anchors of foundation and strain gauges, clinometers, anemoscope and settlement sensors was installed at superstructure. As the results, the main factor which influence the behavior of superstructure is wind velocity, wind direction, rainfall and temperature change. Especially, the uplift load at stub of transmission structure revealed about 35.4 percentages of design load. Hereafter the long term stability will be analyzed.

  • PDF

미얀마 장기 계통계획 수립 결과 및 전망 (Master Plan for Long-term Transmission System in Myanmar)

  • 허연;김종화;한경남;최영성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.9-11
    • /
    • 2005
  • kEPCO is now conducting a project called the "Feasibility Study & Basic Designs for the 500kV Transmission System in Myanmar" as its second overseas project following the "Development Study on the rover System Network Analysis in Myanmar" performed from 2001 to 2002. As a part of this project, this paper deals with the analysis process and results of the demand forecasts, master plan for transmission system expansion, and the major factors for the new 500kV transmission facilities.

  • PDF

ALC 기능을 갖는 VSAT용 송신전력 제어기 (The Transmission Power Controllers for the VSAT Having the ALC Functions)

  • 홍성택;신강욱;이동근;이영우
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 D
    • /
    • pp.2495-2497
    • /
    • 2005
  • The satellite communication equipment, which has been installed and operated for the flood forecast and warning system at KOWACO, needs the review of the transmission Power control for keeping the stable operation of the satellite communication equipments. In this study, made the sample hardware for the transmission power control at Mini-Hubs and remote sites, and developed the control algorithm for stable operation of the transmission power controller.

  • PDF