• 제목/요약/키워드: transmission power

검색결과 5,780건 처리시간 0.035초

Auto-Configuration Downlink Transmission Power Approach For Femtocell Base Station

  • Alotaibi, Sultan
    • International Journal of Computer Science & Network Security
    • /
    • 제22권4호
    • /
    • pp.223-228
    • /
    • 2022
  • Femtocells are being incorporated into heterogeneous networks in order to increase the network capacity. However, intensive deployment of femtocells results in undesired interference, which lowers the system's performance. Controlling the femtocell transmission power is one of of the aspects that can be addressed in order to mitigate the negative effects of the interference. It may also be utilized to facilitate the auto-configuration of the network's conductance, if necessary. This paper proposes the use of an auto-configuration technique for transmission power. The suggested technique is based on the transmission power of macrocells and the coverage provided by femtocells. The simulation findings show that the network's capacity has increased, and the amount of interference has decreased.

345kV 인천화력 송전선로 철탑도괴 원인분석 및 대책 (Analysis and Countermeasures of 345kV Incheon-TP Overhead Transmission Lines Collapse)

  • 민병욱;신태우;최진성;최한열;박재웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.323_324
    • /
    • 2009
  • 345kV Incheon Thermal Power Plant Transmission Line Collapse Analysis and Countermeasures. The Typhoon Galmaegi which had been formed in July 15, 2008 diminished into a tropical cyclone and cooled the air above the West Sea. The cooled air colliding with the warm inland air caused a strong whirlwind at some places in the west seaside; the whirlwind battered the 345kV Incheon Thermal Power Plant Transmission Line to be collapsed. The resistance against wind pressure, one of the key elements in transmission line engineering, is designed to endure the pressure corresponding to the maximum instantaneous wind speed. Before the above accident happened, no transmission line has ever been collapsed by a whirlwind. So this paper is aimed to analyze causes that collapsed 345kV Incheon Thermal Power Plant transmission line and to introduce countermeasures.

  • PDF

연계 계통에서의 환경적 배출량과 손실을 고려한 최적 경제급전 (Multi-Area Economic Dispatch Considering Environmental Emission and Transmission Losses)

  • 최승조;이상봉;김규호;유석구
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 하계학술대회 논문집 A
    • /
    • pp.341-343
    • /
    • 2000
  • Traditionally electric power system are operated in such a way that the total fuel cost is minimized regardless of accounting for tie-lines transmission constraint and emissions produced. But tie-lines transmission and emissions constraint are very important issues in the operation and planning of electric power system. This paper presents the Two-Phase Neural Network(TPNN) to solve the Economic Load Dispatch (ELD) problem with tie-lines transmission and emissions constraint considering transmission losses. The transmission losses are obtained from the B-coefficient which approximate the system losses as s quadratic function of the real power generation. By applying the proposed algorithm to the test system, the usefulness of this algorithm is verified.

  • PDF

HVDC 해저케이블 고장점 탐지 사례 연구 (A Study on the HVDC Submarine Cable Fault Location Searching Case)

  • 문신용;김정대;장석한
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.138-140
    • /
    • 2006
  • 한국전력공사(이하 한전)에서는 제주지역 전력공급의 안정을 위해 '98년부터 국내 최초로 육지전력 계통과 연계하여 장거리 해저케이블 송전선로를 건설하여 운영하고 있다. 해저케이블은 해저에 포설되고 외부적 환경에 견디기 위해 육상케이블과 다른 많은 보호층을 포함하고 있어 설비의 유지보수에 많은 제약사항을 안고 있다. 특히 해남${\sim}$제주 연계선로는 기술적 장점 때문에 AC송전 대신 HVDC 송전을 하고 있어 한단계 Upgrade된 설비운영 기술이 필요하다. 본 고에서는 HVDC 해저 케이블의 설비운영에 있어 선로의 고장시 케이블의 고장점 위치를 탐지하는데 중점을 두어 실제 고장점 탐지 사례를 중심으로 HVDC 해저 케이블 고장점 탐지 방법 및 시험 결과를 검토하고 향후 유사 고장 발생에 효과적으로 대응하기 위한 절차를 제시하였다.

  • PDF

Study on Continuously Variable System Using to Centrifugal Belt Pulley

  • Do, Hyung-jin;Youm, Kwang-Wook
    • International journal of advanced smart convergence
    • /
    • 제9권1호
    • /
    • pp.10-18
    • /
    • 2020
  • In the case of a belt-pulley type CVT that transmits a driving force by using a variable pulley and a metal belt, slippage occurs due to transmission of power by using a belt, which results in a decrease in efficiency. Therefore, in this study, the rails were machined on the plate surface of the pulley to reduce the friction and slip between the belt and the pulley while applying the characteristics of the CVT. As the plate is rotated by the shape of the rail, a centrifugal belt pulley type continuously variable transmission system which shifts while varying the radius of rotation of the belt that transmits power is studied. Accordingly, the structure of the pulley was designed and the centrifugal belt pulley type continuously variable transmission was Manufactured. In addition, to verify the suitability of the manufactured transmission, the power transmission efficiency was monitored by establishing an interface with the controller. The structural analysis of the plate proved the suitability of the centrifugal belt pulley type continuously variable transmission.

암절연물을 적용한 송전철탑 연구 (A Study on Transmission Tower by Applying Polymer Insulation Arms)

  • 박효열;안명상;이태주;이동일;최인혁;김정호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 춘계학술대회 논문집
    • /
    • pp.1-4
    • /
    • 2005
  • The electric power demand is steadily high. It becomes difficult to secure the land for overhead transmission lines year after year. Downsizing of overhead transmission lines can be most effectively achieved by applying polymer insulation arm. This paper describes the outline of compact overhead transmission lines and the result of mechanical evaluation of FRP for the compact transmission towers. Bending strength of FRP was evaluated according to the fiber orientation because the fiber orientation in FRP has a great effect on the strength of FRP.

  • PDF

송전계통의 확률론적 신뢰도 평가에 관한 연구 (A Study on Probabilistic Reliability Evaluation of Transmission System)

  • 강성록;김근호;트란트룽 틴;최재석;;이용태;문승필;추진부
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 A
    • /
    • pp.42-45
    • /
    • 2003
  • This paper presents a method for assessing reliability indices of transmission system. Because successful operation of electric power under the deregulated electricity market depends on transmission system reliability management, quantity evaluation of transmission system reliability is very important. The key point idea is based on that the reliability level of transmission system is equal to reliability level difference of between composite power system(HLII) and generation system(HLI). It is the reason that composite power system includes uncertainties and capacity limit of transmission lines. The practicality and effectiveness of this methodology are illustrated by the case study using the KEPCO size system.

  • PDF

고효율 무선 전력 전송을 위한 고효율 E급 전력 증폭기 및 공진 코일 설계에 관한 연구 (Study on the Design of High Efficient Class-E Power Amplifier and Resonant Coils for High Efficient Wireless Power Transfer System)

  • 윤충모
    • 한국전자통신학회논문지
    • /
    • 제11권10호
    • /
    • pp.935-940
    • /
    • 2016
  • 최근 무선 전력 전송 시스템은 조명 분야뿐만 아니라 전기 자동차, 스마트폰 무선 충전 시스템 등 다양한 분야에서 기술이 점차 확대 적용되고 있다. 무선 전력 전송 시스템의 전력 전송 효율을 판가름 하는 가장 큰 두가지 요소로는 전력을 무선으로 전달하는 매개체인 송, 수신 코일부와 전력을 증폭하는 전력 증폭기부가 해당된다. 본 논문에서는 고효율 무선 전력 전송 시스템을 구축하기 위해 6.78MHz에서 동작하는 고효율 전력 증폭기 설계 방안과 공진 코일 제작 방법에 대해 소개한다.

전력선 통신을 이용한 집단주택 안전관리 시스템 (Security Monitoring System for Apartment House Building Using Paver Line Carrier)

  • 김인수;김관호;김요희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 A
    • /
    • pp.476-478
    • /
    • 1993
  • Instead of installing new communication wiring to each house in the apartment house building. the power distribution network. which is already installed in the building. can be use as communication medium. In a safty management, by adoption of power line communication system, at remote we can monitor safty related sensors such as fire, gas leakage, burglar intrusion and emergency call which are located at each house. From this viewpoint, we developed security monitoring system for apartment house building using power lines. Security monitoring system consists of Power Line Communication-Sub Controller (PLC-SC). Power Line Communication-Main Controller (PLC-MC) and Management System (MS). Between a PLC-MC and a PLC-SC, the transmission rate is 1200 bps in power lines and modulation technique is frequency shirt keying (FSK). In between a PLC-MC and a MS, the transmission rate is 1200 bps in communication line (RS-485). As a result of this research. transmission loss is 0.1dB per meter of intrabuilding distribution network. Transmission can be reach in 250 meters. So it is enough to communicate for security monitoring system in apartment house building.

  • PDF

Probabilistic Power Flow Studies Incorporating Correlations of PV Generation for Distribution Networks

  • Ren, Zhouyang;Yan, Wei;Zhao, Xia;Zhao, Xueqian;Yu, Juan
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권2호
    • /
    • pp.461-470
    • /
    • 2014
  • This paper presents a probabilistic power flow (PPF) analysis method for distribution network incorporating the randomness and correlation of photovoltaic (PV) generation. Based on the multivariate kernel density estimation theory, the probabilistic model of PV generation is proposed without any assumption of theoretical parametric distribution, which can accurately capture not only the randomness but also the correlation of PV resources at adjacent locations. The PPF method is developed by combining the proposed PV model and Monte Carlo technique to evaluate the influence of the randomness and correlation of PV generation on the performance of distribution networks. The historical power output data of three neighboring PV generators in Oregon, USA, and 34-bus/69-bus radial distribution networks are used to demonstrate the correctness, effectiveness, and application of the proposed PV model and PPF method.