• Title/Summary/Keyword: transmission power

Search Result 5,783, Processing Time 0.038 seconds

Adaptive Link Quality Estimation in Wireless Sensor Networks (무선 센서 네트워크에서 가변주기를 이용한 적응적인 전송파워 제어 기법)

  • Lee, Jung-Wook;Chung, Kwang-Sue
    • Journal of KIISE:Computing Practices and Letters
    • /
    • v.16 no.11
    • /
    • pp.1081-1085
    • /
    • 2010
  • In the wireless sensor networks, power consumption and interference among the nodes can be reduced by using the transmission power control. Because link quality is changed by spatial and temporal effect, link failures are frequently occurred. In order to adapt to link quality variation, existing transmission power control schemes broadcast beacon messages periodically to neighbor nodes and control the transmission power dynamically. However, it can effect on the time and energy overhead according to period of transmission power control. In this paper, the dynamic method of transmission power control by the link quality variation and variable period are proposed. When a link quality is unstable, the control duty cycle is reduced and the link quality is agilely maintained. In contrast, when link quality is stable, the control period is increased and control overhead is decreased.

Development of Transmission & Substation Geographic Information System (송변전지리정보시스템(TGIS) 개발 추진현황 및 향후과제)

  • Ahn, Tae-Hyung;Moon, Bong-Soo;Kwon, Oh-Hyung
    • Proceedings of the KIEE Conference
    • /
    • 2005.07a
    • /
    • pp.575-577
    • /
    • 2005
  • KEPCO has developed Transmission & Substation Geographic Information System(TGIS) since 2000. TGIS is the system for the management of transmission and substation facilities on the geographic basis. This paper provides a brief introduction to TGIS.

  • PDF

Installation methods of OPGW for 765kV overhead power transmission lines (765kV 가공 송전선로용 OPGW 시설공법)

  • Kwan, Y.G.;Kim, Y.;Lee, S.H.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07e
    • /
    • pp.1641-1643
    • /
    • 1998
  • In recent the maximum voltage of overhead power transmission lines in Korea was upgraded to 765kV. In general a overhead ground wire is installed for protecting overhead power transmission lines from lightning. For the 765kV line, Composite Overhead Ground Wire with Optic Fiber (OPGW) is applied as a overhead ground wire and have a function of the communication line between substations. In this paper, the construction and properties of OPGW, and its installation methods are discribed.

  • PDF

Performance Analysis of CVTs with a 2K-H II Differential Gear (2K-HII차동기어 결합형 무단변속기의 성능해석)

  • 박재민;김연수;최상훈
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.4
    • /
    • pp.170-178
    • /
    • 2004
  • Continuously variable transmission (CVT) mechanisms considered here are input coupled types that combine the functions of a 2K-H II type differential gear and a V-belt type continuously variable unit (CVU). For the 8 different mechanisms, 4 of them are power-circulation modes while the other 4 are power-split modes, various performance analysis (speed ratios, power flows, divisions of power transmission in a differential gear and a CVU, and theoretical efficiencies) are performed to vary design parameters. Experimental studies are executed to validate fundamental relations (speed ratios, power flows, efficiencies, occurrence of geared neutral). Some useful characteristics associated with performance also are discussed in the mechanisms.

Scheduling and Power Control Framework for Ad hoc Wireless Networks

  • Casaquite, Reizel;Yoon, Myung-Hyun;Hwang, Won-Joo
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.6
    • /
    • pp.745-753
    • /
    • 2007
  • The wireless medium is known to be time-varying which could affect and result to a poor network's performance. As a solution, an opportunistic scheduling and power control algorithm based on IEEE 802.11 MAC protocol is proposed in this paper. The algorithm opportunistically exploits the channel condition for better network performance. Convex optimization problems were also formulated i.e. the overall transmission power of the system is minimized and the "net-utility" of he system is maximized. We have proven that an optimal transmission power vector may exist, satisfying the maximum power and SINR constraints at all receivers, thereby minimizing overall transmission power and maximizing net-utility of the system.

  • PDF

Stability evaluation of foundation settlement of power transmission tower (송전철탑의 기초침하에 대한 안정성 평가)

  • Lee, Dae-Soo;Cho, Hwa-Kyung;Kim, Dae-Hong;Ham, Bang-Uk
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2005.03a
    • /
    • pp.687-696
    • /
    • 2005
  • Safety diagnosis was conducted to evaluate the long-term stability evaluation of power transmission tower of which deformation of the upper structural elements occurred. To assess the cause of the structural deformation, field investigation including BIPS, down-hole test, concrete pile coring and finite element analysis were carried out. From these studies, the major cause of deformation was found due to the heavily fractured layer and weathered soil topography at the pile tip area. The cement-milk grouting method was proposed to reinforce these weak zone around the pile tip area. Also, the increase of cross-section and stiffness for steel members of upper tower structures was suggested. Instrumental monitoring was proposed as well to verify reinforcing effect.

  • PDF

Power Flow Analysis for Manufacturing of Planetary Gears in an 8-speed Automatic Transmission (II): 4-8 Speeds (8단 자동변속기의 유성기어 가공을 위한 동력 흐름 해석 (2) : 4-8단)

  • Lee, Kyoung-Jin;Kim, Jeong-Min
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.15 no.5
    • /
    • pp.57-65
    • /
    • 2016
  • The power flow of an 8-speed automatic transmission was analyzed using a lever analogy for the manufacturing of planetary gears. From the analysis, we found that the engine power was split between the first and second double-pinion planetary gears (DPPG1 and DPPG2), and was then passed to the DPPG3 for the fourth speed. For the fifth speed, the engine power was split between the DPPG1 and DPPG3. For the speeds 6-8, the engine power was passed only to SPPG2, while the seventh speed contained the power circulation.

Feasibility Study for the Ghana-Mali 225kV Interconnection Project (서부아프리카 국가간 연계 송전망 타당성 조사)

  • Kim, Jong-Hwa;Lee, Chul-Hyu;Lee, Young-Gil;Choi, Sang-Ju
    • Proceedings of the KIEE Conference
    • /
    • 2008.07a
    • /
    • pp.38-39
    • /
    • 2008
  • KEPCO conducted the project called the "Feasibility Study for the Han (Ghana) - Bobo Dioulasso (Burkina Faso) - Bamako (Mali) Interconnection Project" as its first African project. This paper deals with power system analysis and Transmission line and substation design of approximately 750 kilometers of the 225 kV single circuit transmission lines and six substations. The main contents of the power system analysis results and preliminary engineering design include power flow, transient stability, eigenvalue analysis, transmission line design, substation design and economic analysis.

  • PDF

Evaluation of Effects on Power System by Installing the Static Var Compensator (SVC 설치 운전에 따른 계통의 영향성 평가)

  • Yoon, Jong-Su;Kim, Yong-Hak;Kim, Soo-Yeol
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.59 no.7
    • /
    • pp.1187-1193
    • /
    • 2010
  • This paper provides the methods for enhancing the stability with normal or emergency operating conditions in real power systems and copes with the unbalance of demand of reactive power due to the loss of facility, such as 765kV transmission line. In this paper, we focused on the maximum allowable transmission power(hereafter, MAXTP) in the metropolitan area. In order to increase the MAXTP, the application of reactive power compensators, SVC, and Shunt compensator and reactor, is analyzed as an enhancing method of stability and MAXTP. Particularly, the f-V analysis was performed for the postulated contingency, in order to evaluate the effects on SVC. Conclusively, the stability of power systems could be enhanced and the MAXTP is increased effectively with Dongseoul SVC which has the capacity 200MVAr.

An Algorithm for Transfer Capability Evaluation in Power Systems with FACTS Device (FACTS적용계통에서의 송전용량 평가 알고리즘)

  • Yoon, Yong-Beum;Yoon, Jong-Su;Choo, Jin-Boo
    • Proceedings of the KIEE Conference
    • /
    • 1998.07c
    • /
    • pp.880-883
    • /
    • 1998
  • In this paper, sensitivity based approach to estimate BITC(bilateral interchange transfer capacity) considering the real power flow control function of FACTS device is presented. The real power flow setting of the FACTS device is adjusted so that it transfer the power flow from the first violation point of transmission capacity to other transmission lines in the power system, thus allowing more power to be transferred from the specified generator bus to the specified load bus. The transfer between the two bus locations is increased from this new operating condition until a violation of transmission capacity limits occurs or until the setting of the FACTS device can no longer be adjusted. The proposed algorithm is illustrated using examples of small and real life power system.

  • PDF