• Title/Summary/Keyword: transmission lines

Search Result 1,307, Processing Time 0.027 seconds

Calculation for Equivalent Parameter of Multi Transmission Lines by Moment method (모멘트법에 의한 전송 선로의 등가 파라미터 계산)

  • 김기래
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.3 no.2
    • /
    • pp.255-265
    • /
    • 1999
  • Recently the necessity of MMIC is increasing because clock frequency goes up by digital data transmission of Gbps class being demanded and the density of circuits gets high for the purpose of lightening and miniaturizing system, owing to the development of ultra high speed. When massing lines in a MMIC and super high speed integrated circuit cause the crosstalk and dispersion of signal, a digital signal is distorted and EMI is occurred. To solve this problems, It is necessary to analyze the equivalent parameters of transmission lines. This paper represent the results of the equivalent parameters of transmission lines for single and hi-level structure by using moment method.

  • PDF

Dynamic Stiffness Design of Inspection Robot Frame Using Multi-body Dynamic Simulation (동역학 해석을 통한 송전선로 검사로봇 프레임 설계에 관한 연구)

  • Lee, Jun Young;Kim, Moon Young;Lim, Ji Youn;Kim, Chang Hwan;Yim, Hong Jae
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.25 no.3
    • /
    • pp.169-175
    • /
    • 2015
  • This study aims to improve the dynamic stiffness of an inspection robot frame to prevent derailment from transmission lines. Finite element models for the transmission lines and robot frame are developed for the multi-body dynamic simulation. Natural frequency analysis was conducted using the FE models. Three types of spacer damper clamps installed on 4-conductor transmission lines are used to evaluate the derailment of the robot. Multi-body dynamic simulations with FE models are demonstrated for sub-span oscillation. When the robot operates, derailment of inspection robot from the transmission lines is determined because of resonance. To prevent the resonance, body position was changed and thickness optimization was conducted. The results show that derailment was not occurred because of the natural frequency improvement.

A Design Database for High Speed IC Package Interconnection (고속 집적회로 패키지 인터커넥션을 위한 설계 데이타베이스)

  • ;;;F. Szidarovszki;O.A.Palusinski
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.12
    • /
    • pp.184-197
    • /
    • 1995
  • In this paper, high speed IC package-to-package interconnections are modeled as lossless multiconductor transmission lines operating in the TEM mode. And, three mathematical algorithms for computing electrical parameters of the lossless multiconductor transmission lines are described. A semi-analytic Green's function method is used in computing per unit length capacitance and inductance matrices, a matrix square root algorithm based on the QR algorithm is used in computing a characteristic impedance matrix, and a matrix algorithm based on the theory of M-matrix is used in computing a diagonally matched load impedance matrix. These algorithms are implemented in a computer program DIME (DIagonally Matched Load Impedance Extractor) which computes electrical parameters of the lossless multiconductor transmission lines. Also, to illustrate the concept of design database for high speed IC package-to-package interconnection, a database for the multi conductor strip transmission lines system is constructed. This database is constructed with a sufficiently small number of nodes using the multi-dimensional cubic spline interpolation algorithm. The maximum interpolation error for diagonally matched load impedance matrix extraction from the database is 1.3 %.

  • PDF

Measurement and Analysis of Magnetic Field near 345/154kV UHV Overhead Transmission Lines and Substations (345/154kV 초고압 송변전설비 주변에서의 자장의 측정과 분석)

  • Lee, J.G.;Ahn, C.H.;Lee, B.H.;Kil, G.S.;Park, D.H.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1813-1815
    • /
    • 1996
  • With the three dimensional magnetic field measuring system dealt with in this paper, accurate measurements and analyses of ELF magnetic fields in the vicinity of UHV overhead transmission lines and substations have been conducted. For the field measurements multiturn loop-type sensors have been developed with special consideration of taking lower frequency and spatial components without any distortion. So the measuring system has the frequency bandwidth of 8[Hz] to about 53[kHz] and the response sensitivity of $9.88[mV/{\mu}T]$ in average. A brief description of design rules of the measuring system and measurement procedures is given. The actual surrey near 154 and 345[kV] overhead transmission lines and power subststions was carried out and analyzed. It may be inferred from these results that the maximum magnetic field intensities under typical UHV overhead transmission lines do not exceed $20[{\mu}T]$ so that the field measurements satisfy sufficiently all limits or guidelines that various authorized international institutes recommend.

  • PDF

A Study on transmission lines energized initially to restore wide black out Power system (대정전 계통 복구를 위한 시송전 선로에 관한 연구)

  • Lee, H.J.;Kim, G.D.;Park, S.M.;Bae, J.C.;Hwang, B.H.;Hong, S.C.;Kim, K.D.;Lee, N.H.
    • Proceedings of the KIEE Conference
    • /
    • 2001.07a
    • /
    • pp.377-379
    • /
    • 2001
  • When a wide area blackout occurres, reenergizing transmission lines should be done at first. The KEPCO(Korea Electric Power Corporation) divides whole power system grid into seven subsystem, and each subsystem has one of two blackstart power plants which are usually hydro or combined-combustion type, one priority power plant which should be first supplied with electric energy, and transmission lines between them. Voltage rising, line charging, and operation stability problem should be considered when these lines are reenergized. In this paper, building-up process for primary transmission system that should be energized at first is analyzed.

  • PDF

The Design, Manufacture and Applications of a Gap Noise Generator for Testing the Characteristics of EMI from Transmission Lines (송전선로 EMI 특성 실험용 인공잡음발생장치 설계, 제작 및 적용)

  • Ju, Yun-Ro;Yang, Gwang-Ho;Myeong, Seong-Ho;Lee, Dong-Il;Sin, Gu-Yong
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.51 no.1
    • /
    • pp.23-28
    • /
    • 2002
  • In order to survey the radiation characteristics of pure line noise of unwanted noise from overhead high voltage AC transmission lines, a disk type gap noise generator was manufactured. Disk size which decides capacitance between the noise generator and earth was selected through preliminary indoor experiments and analysis by using surface charge method. The capacitance is one of principal parameters related to the injection of a proper noise current into lines. On the basis of the capacitance obtained from calculation, 5mm of space was given to the gap of the noise generator to be installed o test line and an aluminum disk of 60cm radius was made. The field experiments were performed with the noise generator hung on the Kochang 765 kV full scale test line. As the results, the useful data which can be used to analysis the radiation characteristics of noise from transmission lines were obtained. Those are the directivity of antenna toward the line, lateral profiles, frequency spectra, height pattern and so on.

Reliability Assessment of Forest Fire on Silicone Polymer Insulators in Transmission Lines( I ) (송전용 실리콘 폴리머애자의 산불영향 신뢰성 평가( I ))

  • Choi, In-Hyuk;Lee, Dong-Il;Chung, Yong-Woon;Yu, Kun-Yang
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.17 no.11
    • /
    • pp.1199-1204
    • /
    • 2004
  • Most overhead transmission lines in Korea run over the mountain; however, only little study has been made for the effect of mountain fire on polymeric insulator for transmission lines, though the study is significantly required, Therefore, in this study, the authors observed the deformation of the sheds of the insulator under fire, varying the ignition time using artificial ignition testing equipment, and investigated electrical and mechanical characteristics of the insulator through dry withstand voltage test, impulse flashover test and tensile load test. As the results of the tests, the following conclusions were obtained, First, when the insulator was subjected to the fire, the electrical characteristics were slightly reduced, but there was no change on the mechanical characteristics, Secondly, the sheds and sheath of the insulator were not non-flammable but less-flammable. These two results show the high mechanical stability and durability of the insulator under severe fire condition, though the electrical characteristics can be deteriorated as the time that the insulator is subjected to fire, goes by.

Analysis of the Competitive Effects of Financial Transmission Rights on Electricity Markets (재무적 송전권의 전력시장에의 영향 분석)

  • 김진호;박종배;신중린
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.53 no.6
    • /
    • pp.350-357
    • /
    • 2004
  • In a deregulated electricity generation market, the sufficient capacity of transmission lines will promote the competition among generation companies (Gencos). In this paper, we show that Gencos' possession of rights to collect congestion rents may increase the competition effects of the transmission lines. In order for concrete analysis on this effect, a simple symmetric market model is introduced. In this framework, introducing the transmission right to the Gencos has the same strategic effects as increasing the line capacity of the transmission line. Moreover, the amount of effectively increased line capacity is equal to the amount of the line rights. We also show that the asymmetric share of the financial transmission rights may result in an asymmetric equilibrium even for symmetric firms and markets. We also demonstrate these aspects in equal line rights model and single firm line rights model. Finally, a numerical example is provided to show the basic idea of the proposed paper.

Transmission Performance Evaluation of Hybrid Lines Composed of SMF and MMP for FTTx Systems (단일 모드 광섬유와 다중 모드 광섬유 혼합 라인으로 구성된 FTTx 시스템의 전송 성능 평가)

  • Park, Seung-Hyeon;Kim, Kyong-Hon;Lee, El-Hang
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.7A
    • /
    • pp.535-541
    • /
    • 2005
  • This paper proposes a hybrid optical lines composed of single-mode fiber(SMF) and multi-mode fiber(MMF) for gigabit-capable Passive Optical Network(GPON) using a WDM method with a single light source per each channel, and reports the results of transmission performance the proposed lines. The transmission link uses a direct modulated DFB-LD for high speed downstreams at the optical line terminal(OLT) of central office(CO) and a low cost SFP type transceiver for low-speed upstream in optical network unit(ONU). To split or combine the transmission channels, wavelength MUX/DEMUX are used in the optical line section, and MMFs not longer than 1 km are attached to the SMF lines at the ONU side of the WDM-PON links. We have performed the transmission experiment on the downstream of 2.5 Gbit/s, and 1.25 Gbit/s, and the upstream of 1.25 Gbit/s, and 622 Mbit/s which are recommended by ITU-T G.984.2. The transmission margin and feasibility of the proposed links have been tested to be suitable up to 2.5 Gbit/s transmission.

FM Reflectometric Measurement of Group Velocities of Microwave Transmission Lines

  • Park, Yong-Hyun;Lee, Jeong-Hae
    • Journal of electromagnetic engineering and science
    • /
    • v.3 no.1
    • /
    • pp.67-71
    • /
    • 2003
  • In this paper, frequency modulated(FM) reflectometry is proposed to measure group velocity of microwave transmission line Various microwave transmission lines such as periodically loaded conducting posts in a waveguide and nonradiative dielectric(NRD) guide are adopted to measure their group velocity The result compared with that from network analyzer shows good agreement, indicating the validity of our measurement method.