• Title/Summary/Keyword: transmission line pulse

Search Result 105, Processing Time 0.03 seconds

Enhanced Spatial Modulation of Indoor Visible Light Communication

  • Shan, Ye;Li, Ming;Jin, Minglu
    • Journal of information and communication convergence engineering
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2015
  • In this study, we consider visible light communication in an indoor line-of-sight environment. It has been proved that among the multiple input multiple output (MIMO) techniques, spatial modulation (SM) performs better than repetition coding (RC) and spatial multiplexing (SMP). On the basis of a combination of SM and pulse amplitude modulation (PAM), here, we propose an enhanced SM algorithm to improve the bit error rate. Traditional SM activates only one light-emitting diode (LED) at one time, and the proposed enhanced SM activates two LEDs at one time and reduces the intensity levels of PAM by half. Under the condition of a highly correlated channel, power imbalance is used to improve the algorithm performance. The comparison between the two schemes is implemented at the same signal-to-noise ratio. The simulation results illustrate that the enhanced SM outperforms the traditional SM in both highly correlated and lowly correlated channels. Furthermore, the proposed enhanced SM scheme can increase the transmission rate in most cases.

Analysis. Design and Control of Two-Level Voltage Source Converters for HVDC Systems

  • Mohan, D. Madhan;Singh, Bhim;Panigrahi, B.K.
    • Journal of Power Electronics
    • /
    • v.8 no.3
    • /
    • pp.248-258
    • /
    • 2008
  • The Voltage Source Converter (VSC) is replacing the conventional line commutated current source converters in High Voltage DC (HVDC) transmission systems. The control of a two-level voltage source converter and its design dealt with HVDC systems and various factors such as reactive power, power factor, and harmonics distortion are discussed in detail. Simulation results are given for the two-level converter and designed control is used for bidirectional power flow. The harmonics minimization is taken by extending the 6-pulse VSC to multipulse voltage source converters. The control is also tested and simulated for a 12-pulse voltage source converter to minimize the harmonic distortion in AC currents.

Design of Robust Current Controller Using GA for Three Level 24-Pulse VSC Based STATCOM

  • Janaki, M.;Thirumalaivasan, R.;Prabhu, Nagesh
    • Journal of Power Electronics
    • /
    • v.11 no.3
    • /
    • pp.375-380
    • /
    • 2011
  • A STATic synchronous COMpensator (STATCOM) is a shunt connected voltage source converter (VSC) based FACTS controller using Gate Turn Off (GTO) power semiconductor devices employed for reactive power control. The operation principal is similar to that of a synchronous condenser. A typical application of a STATCOM is voltage regulation at the midpoint of a long transmission line for the enhancement of power transfer capability and/or reactive power control at the load centre. This paper presents the modeling of STATCOM with twenty four pulse three level VSC and Type-1 controller to regulate the reactive current or the bus voltage. The performance is evaluated by transient simulation. It is observed that, the STATCOM shows excellent transient response to step change in the reactive current reference. While the eigenvalue analysis is based on D-Q model, the transient simulation is based on both D-Q and 3 phase models of STATCOM (which considers switching action of VSC).

Self-Preionization Effects of the Nitrogen Laser Using High Voltage Pulse Power Suply (고전압 펄스형 전원을 사용한 질소레이저의 자체 선전리 효과)

  • 이치원;안근옥;추한태;양준묵
    • Korean Journal of Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.169-177
    • /
    • 1990
  • We have constructed the laser system which was consisted of a high voltage pulse poner supply, a rapid high voltage spark gap and the Blumlein transmission line circuit of the multiple parallel plate capacitor type, and have studied the self-preionization effect from this laser system without additional modifications. The value of inductive or resistive loading of the laser oscillator seems to have a significant effect on the preionization. The optimal operational condition of this laser system was obtained at the inductive loading of L = I mtl across the laser tube with the spark gap distance of 6.0 mm. nitrogen pressure of 50 torr, when repetition rate was 70 Hz. Stability was found to be better than 2.0Yo and EIP was 867 V/cm.torr.

  • PDF

Observation of the Preionization effect and Operational Characteristics of a Nitrogen Laser by a Pulse type high Voltage Power Supply (펄스형 고전압 전원에 의한 선전리 현상의 관측과 질소레이저의 동작 특성)

  • Lee, Bong-Yeon
    • Korean Journal of Optics and Photonics
    • /
    • v.17 no.1
    • /
    • pp.60-67
    • /
    • 2006
  • We constructed a TEA $N_2$ laser which consists of spark gap, pulse type high voltage power supply, Blumlein transmission line circuit, laser tube with Ernst electrode. We observed the self-preionization with an optical fiber in the spark gap and laser tube. The higher voltage power supplied to the Blumlein transmission line circuit, the better preionization was. An U-type transformer yielded better stability and output power than an I-type transformer. The discharge time after triggering a spark gap for the U-type transformer was also short. We obtained the stability of $2.7\%$ and output power of $36{\mu}J$ when the optimum conditions of the laser operation were spark gap distance of 6.0 mm, electrode distance in laser tube of 5.0 mm, $N_2$ gas flow rate in spark gap of 1500 cc/min, $N_2$ gas flow rate in laser tube of 4 ${\iota}$/min, output window reflectivity of $40\%$ and repetition rate of 10 Hz.

Eletrostatic Discharge Effects on AlGaN/GaN High Electron Mobility Transistor on Sapphire Substrate (사파이어 기판을 사용한 AlGaN/GaN 고 전자이동도 트랜지스터의 정전기 방전 효과)

  • Ha Min-Woo;Lee Seung-Chul;Han Min-Koo;Choi Young-Hwan
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.54 no.3
    • /
    • pp.109-113
    • /
    • 2005
  • It has been reported that the failure phenomenon and variation of electrical characteristic due to the effect of electrostatic discharge(ESD) in silicon devices. But we had fess reports about the phenomenon due to the ESD in the compound semiconductors. So there are a lot of difficulty to the phenomenon analysis and to select the protection method of main circuits or the devices. It has not been reported that the relation between the ESD stress and GaN devices, which is remarkable to apply the operation in high temperature and high voltage due to the superior material characteristic. We studied that the characteristic variation of the AlGaN/GaN HEMT current, the leakage current, the transconductance(gm) and the failure phenomenon of device due to the ESD stress. We have applied the ESD stress by transmission line pulse(TLP) method, which is widely used in ESD stress experiments, and observed the variation of the electrical characteristic before and after applying the ESD stress. The on-current trended to increase after applying the ESD stress. The leakage current and transconductance were changed slightly. The failure point of device was mainly located in middle and edge sides of the gate, was considered the increase of temperature due to a leakage current. The GaN devices have poor thermal characteristic due to usage of the sapphire substrate, so it have been shown to easily fail at low voltage compared to the conventional GaAs devices.

Design and Manufacture of Phase Shifter for 400 W Pulse Signal in X-Band (X-대역 400 W 펄스신호를 위한 위상변환기 설계 및 제작)

  • Park, In-Yong;Min, Seung-Hyun
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.46 no.3
    • /
    • pp.251-256
    • /
    • 2018
  • In the case of a radar repeater that used for the trajectory tracking of a high-speed aircraft, it emits pulses of short width. For phase displacement of these signals a branch type phase shifter is used. The phase on the transmission line is changed by utilizing the variable reactance at the end of the displacement branch transmission line. Further, it is easy to control the high output signal, and there is an advantage that the insertion loss is not large even when the reactance fails. In this paper, we will discuss the fabrication test results of a 400 W class phase shifter that sequentially displaces the phase at $0^{\circ}$, $30^{\circ}$, $60^{\circ}$, $90^{\circ}$.

Performance Analysis of SSSC with Switching-level Simulation Model and Scaled Hardware Model

  • Han, Byung-Moon;Kim, Hee-Joong;Baek, Seung-Taek
    • Journal of Power Electronics
    • /
    • v.1 no.1
    • /
    • pp.48-55
    • /
    • 2001
  • This paper describes a switching-level simulation model and scaled hardware model for SSSC, which is useful for analyzing the dynamic interaction between the SSC and the power transmission system. A detailed simulation model with EMTP was developed to verity the SSSC operation with control system, and its increasing capability of power transmission through the line for a typical one-machine infinite-bus system. The simulation results of the developed model are compared with the experimental results froma scaled model fo 2KVA rating for evaluation the whole system operation.

  • PDF

Improvement of transmission-line-based fault locating for typical traveling-wave accelerator with constant-gradient structures

  • T.N. Hu;Y.F. Zeng;K. Peng;H. Hu;H.M. Wang;K.F. Liu
    • Nuclear Engineering and Technology
    • /
    • v.56 no.6
    • /
    • pp.2011-2018
    • /
    • 2024
  • Since RF breakdown is one of the primary limitations to improving the performances of RF accelerators, extensive efforts have been dedicated to locating the breakdowns. However, most existing methods rely on specialized techniques, resulting in high financial burdens. Although the method based on transient response of transmission line (TL) is suitable for facilities with sporadic recoverable breakdowns, practical operations are susceptible to notable errors. This study revisits the fundamental theories of lossless TL and investigates the wave process to understand the characteristics of the reversed pulse induced by the breakdowns. By utilizing steadystate response of the TL and employing phasor method, we derive analytical formulas to determine the exact location of breakdowns within the faulty cell for constant-gradient TW accelerator. Furthermore, the derived formulas demonstrate their independence from RF phase, thereby distinguishing them from traditional phasebased methods. Additionally, experimental validations are conducted at the HUST injector, and the results confirm the consistency of the analysis. Thus, the proposed method represents a promising improvement over the TL-based approaches and serves as a valuable complement to current techniques. Importantly, this method demonstrates particular advantages for constructed TW accelerators seeking to achieve a balance among high performance, low costs, and compact layouts.

Leakage Current Pulse analysis of Porcelain Insulator at 154kV Transmission Line by use of Pulse Current Method (Pulse current method를 이용한 154kV급 송전용 자기 애자의 누설 전류의 펄스 분석)

  • Lee, Seul-Ki;Ryu, Cheol-Hwi;Lee, Bang-Wook;Choi, Gwang-Beom;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.05a
    • /
    • pp.129-130
    • /
    • 2008
  • 송전선로에 설취된 애자들은 지속적인 전기적 기계적 스트레스에 노출되어 있기 때문에 여러 환경적 요인으로 인해 애자 표변의 열화가 가속된다. 이와 같은 애자의 표면 열화는 dryband를 형성하게 되고 지속적인 애자 표면상의 dryband와 누설 전류 증가의 상호 작용은 애자의 섬락를 일으키는 원인이 된다.[1][2] 이러한 연구의 결과 고전압용 애자로 유입되는 누설 전류는 애자 열화의 정도를 평가할 수 있는 매우 중요한 parameter임을 알 수 있다. 따라서 고전압용 애자의 누설전류를 분석하고 취득하여 애자의 열화 평가 및 이로 인해 발생할 수 있는 결함 애자의 검출에 대한 연구가 절실히 요구되고 있다, 본 논문에서는 고전압용 애자 중 자기애자의 누설전류 특성을 조사하기 위해 자체 제작한 실험 챔버, AC 내전압기, 전류센서r, 오실로스코프, PC등으로 구성된 실험 시스템을 구축하였고, 데이터 분석을 위한 S/W로서 LabView를 사용하였다. 그에 따른 실험 결과로서 정상 애자련과 결함 애자를 포함한 애자련의 누설전류 데이터를 취득하여 본 연구에서 제시한 알고리즘을 통해 분석함으로써 정상 애자 내의 결함 애자 포함 여부를 판별할 수 있었다.

  • PDF