• 제목/요약/키워드: transmission line

검색결과 3,297건 처리시간 0.033초

Basic RF Characteristics of Fishbone-Type Transmission Line Employing Comb-Type Ground Plane (FTLCGP) on PES Substrate for Use in Flexible Passive Circuits

  • Yun, Young;Jeong, Jang-Hyeon;Kim, Hong Seung;Jang, Nakwon
    • ETRI Journal
    • /
    • 제37권1호
    • /
    • pp.128-137
    • /
    • 2015
  • In this work, a fishbone-type transmission line employing a comb-type ground plane (FTLCGP) was fabricated on polyethersulfone (PES) substrate, and its RF characteristics were thoroughly investigated. According to the results, it was found that the FTLCGP on PES showed periodic capacitance values much higher than other types of transmission lines due to a coupling capacitance between the signal line and ground, which resulted in a reduction of wavelength and line width. Using the theoretical analysis, we also extracted the bandwidth characteristic of the FTLCGP on PES. According to the result, the FTLCGP structure showed a cut-off frequency of 280 GHz.

Double-Circuit Transmission Lines Fault location Algorithm for Single Line-to-Ground Fault

  • Yang, Xia;Choi, Myeon-Song;Lee, Seung-Jae
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권4호
    • /
    • pp.434-440
    • /
    • 2007
  • This paper proposes a fault location algorithm for double-circuit transmission lines in the case of single line-to-ground fault. The proposed algorithm requires the voltage and current from the sending end of the transmission line. The fault distance is simply determined by solving a second order polynomial equation which is achieved directly by the analysis of the circuit. In order to testify the performance of the proposed algorithm, several other conventional approaches have been taken out to compare with it. The test results corroborate its superior effectiveness.

Development of a Measuring Instrument of Current and Voltage on Power-Transmission Lines for the Construction of Energy-Network

  • Park, Kyi-Hwan;Jiang, Zhongwei
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.2-107
    • /
    • 2001
  • We propose portable equipment that monitors a current and potential on high-potential power transmission lines. In the equipment, a current and voltage sensor are attached to a hollow insulator that supports a power transmission line: A current on a power line is detected by an air-core solenoidal coil clamped to the line and the detected current signal is transmitted to the ground station by using optical data link, A potential on a power transmission line is detected by a high resistance element, zinc oxide (ZnO) that acts as a potential divider between the power line and the ground. The equipment does not require high potential insulators and magnetic cores which. This leads to the following advantages of the equipment: (a) It is easily installed owing to its small size and its simple structure; (b) It operates in low ...

  • PDF

The Adequacy Analysis for Installation of High Speed Grounding Switches on the Korean 765kV Single Transmission Line

  • Ahn, Sang-Pil;Kim, Chul-Hwan;Park, Nam-Ok;Ju, Hyung-Jun;Shim, Eung-Bo
    • Journal of Electrical Engineering and Technology
    • /
    • 제1권4호
    • /
    • pp.427-434
    • /
    • 2006
  • This paper analyzes arc phenomena including the secondary arc's elongation in the Korean 765kV single transmission line (79km) between Sin-Ansung S/S and Sin-Gapyeong S/S, which will be installed in Korea in June 2006. In particular, both frequency independent and frequency dependent line models are compared to make our final decisions. As well, the significant simulation results are investigated by the EMTP program. As a result, there is no need of HSGS in the Korean 765kV single transmission line from both a practical and an economical point of view.

계통과도전압분석기를 이용한 직류송전선로의 과전압에 대한 기초적 해석 (The Basic Study on Overvoltage of HVDC Transmission Line Using TNA)

  • 우정욱;심정운;곽주식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 E
    • /
    • pp.1810-1812
    • /
    • 1997
  • This paper describes the results of ground fault analysis on HVDC Transmission Line using TNA (Transient Network Analyzer). The maximum overvoltage is about 1.7 p.u. in the case of single line to ground fault on the overhead transmission line. When the cable is linked to the end of the overhead transmission line, the maximum overvoltage is about 1.58 p.u..

  • PDF

400Kb/s급 디지털 가입자 전송 시스템에 적합한 적응형 선로 등화기의 구현 (Implementation of the Adaptive Line Equalizer for a Digital Subscriber Loop Transmission System Operating at 400Kb/s)

  • 염흥열;김재근;조규섭
    • 대한전자공학회논문지
    • /
    • 제24권3호
    • /
    • pp.387-393
    • /
    • 1987
  • The introduction of a digiral subscriber loop transmission system necessitates an optimized line interface solution. To meet this objective an adaptive line equalizer has been developed. The equalizer can be compensated up to 42 dB line loss at 200KHz, and operated up to 3.2 Km transmission length (0.4 mm\ulcornercable)at a rate of 400Kb/s. This has been builted using a variable \ulcorner equalizer to compensate a frequency-attenuation characteristics of metallic cable, an AGC (automatic gain control) circuits with simple control algorithm, and various filters to minimize a transmission constraints over subscriber loop. The purpose of this paper is to present a short description of a design of the adaptive line equalizer with a summary of implementation results. Some design concepts and considerations which results in an implementation of the equalizer are also given.

  • PDF

Quantitative Evaluation of Dislocation Density in Epitaxial GaAs Layer on Si Using Transmission Electron Microscopy

  • Kim, Kangsik;Lee, Jongyoung;Kim, Hyojin;Lee, Zonghoon
    • Applied Microscopy
    • /
    • 제44권2호
    • /
    • pp.74-78
    • /
    • 2014
  • Dislocation density and distribution in epitaxial GaAs layer on Si are evaluated quantitatively and effectively using image processing of transmission electron microscopy image. In order to evaluate dislocation density and distribution, three methods are introduced based on line-intercept, line-length measurement and our coding with line-scanning method. Our coding method based on line-scanning is used to detect the dislocations line-by-line effectively by sweeping a thin line with the width of one pixel. The proposed method has advances in the evaluation of dislocation density and distribution. Dislocations can be detected automatically and continuously by a sweeping line in the code. Variation of dislocation density in epitaxial GaAs films can be precisely analyzed along the growth direction on the film.

Measurement of Noise and Speed in the EMR using Power Line Network

  • Song, Yong-soo;Yoon, Sung-Won;Cho, Young-Bin;Lee, Chung-Keun;Min, Se-Dong;Nam SuK Bang;Lee, Myung-Ho
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2002년도 ICCAS
    • /
    • pp.58-58
    • /
    • 2002
  • Recently Many technologies of the P.L.N (Power Line Network) are introduced for an efficient communication. P.L.N transmits information using power line channel. A medical information transmission system is proposed in this paper for the effective transmission. The Power Line Networks have an advantage in low cost because it uses existent power line. It can be easily applied anywhere that a power line socket is available. But the power line channel is very noisy, because many electronic devices in generate electronic noise in modulated signals. This problem should be considered carefully in the design of medical information transmission system using P.L.N. The proposed system can be applied...I propose a telemedicine system using the power line network.

  • PDF

π-형 전송선 급전 구조를 갖는 대역 통과 필터 (A Band Pass Filter with Feeding Structure Using π-Type Transmission Line)

  • 배주석;임종식;김귀수;안달
    • 한국전자파학회논문지
    • /
    • 제19권2호
    • /
    • pp.114-120
    • /
    • 2008
  • 본 논문에서는 일반적인 반 파장 평행 결합 선로 대역 통과 필터의 입 출력 결합 선로를 K-인버터로 변환하고, K-인버터를 $\pi$-형 전송선 등가로 대체함으로써 $\pi$-형 전송선 급전 구조를 갖는 구조의 대역 통과 필터를 제안하였다. 이 방법은 반 파장 결합 선로 대역 통과 필터의 입 출력 결합 선로 구현 문제에 대한 해결 방안을 제시한다. 또한, 기존의 탭 선로(tapped line) 구조의 설계 방법에 비해 설계 식이 매우 간단하고 정확하여, 특성의 적정화를 위한 노력과 시간을 상당히 줄일 수 있다. 제안된 이론을 바탕으로 $\pi$-형 전송선 급전 구조를 갖는 구조의 대역 통과 필터를 설계 및 제작하였고, 그 결과로부터 제안 방법의 타당성을 입증하였다.

주기적인 계단형 스터브를 갖는 소형화된 하이브리드 Branch-Line 결합기와 Rat-Race 결합기 (Compact Hybrid Branch-line Couplers and Rat-Race Couplers with Periodic Stepped Stubs)

  • 이창언;김원기;김상태;신철재
    • 대한전자공학회논문지TC
    • /
    • 제41권12호
    • /
    • pp.115-124
    • /
    • 2004
  • 본 논문에서는 마이크로스트립 전송선로에 주기적으로 계단형 스터브를 부가하여 물리적 길이를 소형화시킨 마이크로스트립 전송선로를 나타내었다. 주기적인 계단형 스터브는 quasi-static analysis와 전송선 이론을 바탕으로 한 등가모델로 병렬로 부가된 커패시턴스 역할을 함을 보였으며, 기존의 일반 스터브를 이용한 경우보다 짧은 길이의 스터브로 높은 커패시턴스 부가 효과를 얻을 수 있음을 보였다. 그리고 이러한 선로를 이용하여 소형화된 branch-line 결합기와 rat-race결합기를 설계하였다. 1.8 ㎓에서 구현된 각각의 결합기는 677 ㎟, 913 ㎟으로 일반적인 결합기에 비해 그 크기가 62%, 45%로 다른 소자의 부가 없이 단지 전송선로의 변형만을 통해 매우 효과적으로 축소되었다.