• Title/Summary/Keyword: transmission line

Search Result 3,295, Processing Time 0.052 seconds

A Novel Transmission Line Characterization Based on Measurement Data Reconfirmation

  • Eo, Yungseon
    • The Proceeding of the Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.27 no.3
    • /
    • pp.17-27
    • /
    • 2016
  • In the high-frequency characterizations of planar circuit components, measurement data may not be physical. It is mainly due to resonance effects concerned with discontinuities which are inevitable for a planar component characterization. In this paper, a novel accurate transmission line characterization method is presented that excludes the resonance effects based on measurement data reconfirmation. For the physically obvious data acquisition near the resonance frequencies of a transmission line, the additional lines with different line lengths are fabricated on the same substrate. The test transmission lines are characterized by using vector network analyzer (VNA) in 100 MHz to 26.5 GHz. It is shown that an accurate transmission line characterization can be achieved with the proposed measurement data reconfirmation technique.

Series-Gap Characteristics of Transmission Line Arrester with Switching and Lightning Impulse Flashover Test (개폐서지 및 뇌충격 섬락시험에 따른 송전 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.484-485
    • /
    • 2007
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF

Analysis of Different 500kV HVAC Transmission Lines Lightning Shielding

  • Nayel, Mohamed
    • Journal of the Korea Convergence Society
    • /
    • v.4 no.4
    • /
    • pp.49-57
    • /
    • 2013
  • The lightning shielding of different 500 kV HVAC-TL high voltage AC transmission lines was analyzed. The studied transmission lines were horizontal flat single circuit and double circuit transmission lines. The lightning attractive areas were drawn around power conductors and shielding wires. To draw the attractive areas of the high voltage transmission lines, transmission line power conductors, shielding wires and lightning leader were modeled. Different parameters were considered such as lightningslope, ground slope and wind on lightning attractive areas. From the calculated results, the power conductors voltages affected on attractive areas around power conductors and shielding wires. For negative lightning leader, the attractive area around the transmission line power conductor increased around power conductors stressed by positives voltage and decreased around power conductors stressed by negative voltage. In spite of this, the attractivearea of the transmission line shielding wire increasedaround the shielding wire above the power conductor stressed by the positive voltage and decreased around the shielding wire above the power conductor stressed by negative voltage. The attractive areas around power conductors and shielding wires were affected by the surrounding conditions, such as lightning leader slope, ground slope. The AC voltage of the transmission lines made the shielding areas changing with time.

Power Amplifier Design using λ/4 DGS(Defected Ground Structure) Bias Line (λ/4 DGS 바이어스 선로를 이용한 전력증폭기 설계)

  • 정시균;정용채
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.13 no.9
    • /
    • pp.924-931
    • /
    • 2002
  • In this paper, a new λ/4 bias transmission line that is added dumbbell-shaped defected ground structure(DGS) on ground plane of the conventional λ/4 bias transmission line is proposed. This DGS λ/4 bias transmission line maintains high characteristic impedance, but physical width is wider and length is shorter than that of the conventional bias line. If the proposed bias line is attached on signal transmission line, this bias line can reduces the $3^{rd}$ harmonic signal as well as the$2^{nd}$ harmonic signal. With harmonic reduction characteristics, efficiency and linearity of amplifier are improved. The proposed bias line is adopted in power amplifier on IMT-2000 base-station transmitting band. This paper presents several simulations and experimental results of DGS to show validity of the proposed power amplifier using the new λ/4 bias transmission line. Experimental results represent that the $3^{rd}$ harmonic signal is reduced about 26.5 dB and efficiency is improved about 9.1 % and IMD3 is improved 4.5 dB than the conventional structure.

Signal Transmission Scheme for Power Line Communications for Internet of Energy (에너지 인터넷을 위한 전력선 통신의 신호전송 기법)

  • Hwang, Yu Min;Sun, Young Ghyu;Kim, Soo Hwan;Kim, Jin Young
    • Journal of Satellite, Information and Communications
    • /
    • v.12 no.4
    • /
    • pp.146-151
    • /
    • 2017
  • This paper proposes a transmission algorithm that optimizes transmission power and sub-channel allocation to maximize energy efficiency considering characteristics of the channel impedance of power lines in power line communication systems. Since the received power at the receiver is influenced by the characteristics of the power line channel, it is necessary to consider channel characteristics when developing a transmission strategy in a power line communication systems. In addition, the energy efficiency should be optimized while meeting the practical constraints, such as the maximum transmission power limit of the transmitter and minimum quality of service for each user. In the computer simulation, we confirm that the energy efficiency of the proposed algorithm is improved compared to baseline schemes.

Static and Dynamic Behavior of Tunable DFB Laser based on Modal Transmission-Line Theory (전송선로 이론에 기초한 파장 변환 DFB 레이저의 정적 및 동적 작용)

  • Ho, Kwang-Chun
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.14 no.2
    • /
    • pp.147-152
    • /
    • 2014
  • A longitudinal modal transmission-line theory(L-MTLT) to analyze the static and dynamic behavior of two-section distributed feedback (DFB) lasers is used. The characteristic impedance and equivalent propagation constant of DFB structure with active layer are derived from L-MTLT. A two-section DFB laser is analogous to a transmission-line network, in which each section is described by transmission-line block corresponding to the equivalent factors. The longitudinal resonant condition of DFB laser based on equivalent transmission-line network is used to reformulate the rate equations so that static and dynamic behavior of two-section DFB lasers with active layer is demonstrated and analyzed accurately.

Prediction of Flashover and Pollution Severity of High Voltage Transmission Line Insulators Using Wavelet Transform and Fuzzy C-Means Approach

  • Narayanan, V. Jayaprakash;Sivakumar, M.;Karpagavani, K.;Chandrasekar, S.
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.5
    • /
    • pp.1677-1685
    • /
    • 2014
  • Major problem in the high voltage power transmission line is the flashover due to polluted ceramic insulators which leads to failure of equipments, catastrophic fires and power outages. This paper deals with the development of a better diagnostic tool to predict the flashover and pollution severity of power transmission line insulators based on the wavelet transform and fuzzy c-means clustering approach. In this work, laboratory experiments were carried out on power transmission line porcelain insulators under AC voltages at different pollution conditions and corresponding leakage current patterns were measured. Discrete wavelet transform technique is employed to extract important features of leakage current signals. Variation of leakage current magnitude and distortion ratio at different pollution levels were analyzed. Fuzzy c-means algorithm is used to cluster the extracted features of the leakage current data. Test results clearly show that the flashover and pollution severity of power transmission line insulators can be effectively realized through fuzzy clustering technique and it will be useful to carry out preventive maintenance work.

Crosstalk among three microstrip transmission lines (세 개의 마이크로스트립 전송선로간의 크로스톡)

  • 최재연;이상설
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.5
    • /
    • pp.14-21
    • /
    • 1997
  • The crosstalk among three identical uniform coupled microstrip transmissiom lines is examined. To analyze the crosstalk, the simultaneous equations for the voltage and current waves on each transmission line are induced from the transmission line equation. The capacitance and the inductance of the line to solve the transmission line equation are calculated by the spectral domain analysis and the space domian analysis. There are three quasi-TEM modes is three microstrip transmission lines and the characteristics mode impedences in each mode are almost equal at a weak coupling state. The crosstalk among three identical microstrip transmission lines is calculated varying the frequency from 50MHz to 3GHz.

  • PDF

A Method for Calculating the Characteristic Impedance of Substrate Integrated Artificial Dielectric Transmission Lines (기판적층형 가유전체 전송선로의 특성 임피던스 계산 방법)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.8
    • /
    • pp.1585-1591
    • /
    • 2009
  • This paper describes a new method for extracting characteristic impedance of transmission line using Substrate Integrated Artificial Dielectric (SIAD). The new procedure to calculate the characteristic impedance of SIAD transmission line is described with the proper equations and basic transmission line theory. The characteristic impedance is determined as an almost fixed value in the proposed method, while it fluctuates according to frequency in the previous method. As the result, the effective dielectric constant of SIAD transmission line is calculated as a fixed value rather than fluctuating one. In order to show the validity of the proposed method, SIAD microstrip lines are simulated and measured, and characteristic impedances and effective dielectric constant are calculated and compared to the previous method.

A Digital Data Transmission Unit using Asynchronous Protocol for Power Transmission line

  • Nishiyama, Eiji;Kuwanami, Kenshi;Kitajima, Hiroyuki;Kawano, Mitsunori
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2002.10a
    • /
    • pp.79.6-79
    • /
    • 2002
  • We propose here sequential 2 methods for obtain information of current or potential data for power transmission line. One is a digital data transmission unit, this is, an output of a current sensor of power transmission line is digitalized by use of an easy asynchronous protocol. The unit has high speed transform rate, easy making header caused of consisting of only logic circuit. The other is, the output of the unit is transformed via LAN interface and displayed on a personal computer. We have confirmed remote measuring using the method for 100A and 240 A of the current information of power transmission line. Therefore we will be able to see a current waveform by use of internet at a cheep c...

  • PDF