• Title/Summary/Keyword: transmission line

Search Result 3,296, Processing Time 0.029 seconds

A Study on the Design of the Terminal Repeater System for 565 Mb/s Optical Fiber Transmission (565 Mb/s 광전송용 단국중계장치 설계에 관한 연구)

  • 유봉선;박병철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.15 no.10
    • /
    • pp.829-841
    • /
    • 1990
  • On assuming that the transmission speed of the original information is the fifth-order transmission speed of the Korea digital multiplex hierarchy (564.992Mb/s), this paper proposes a new structure of the transmission line frame at the terminal repeater system, in order to not only maintain and conserve 565Mb/s optical fiber transmission system but also make the B.S.I. of digital communication network for the optical transmission. And the structure uses the mBIZ transmission line code, which is considered the optimal transmission line code of conventional transmission line codes. System hardware of the transmission line frame structure proposed in this paper is consisted by a method of pulse stuffing after converting the speed of the original information signal sequence at the terminal repeater system for 565Mb/s optical transmission. As a result of this, we can prevent the optical transmission system from a domino phenomenon, the phenomenon of the continuous error multiplication of systems by the transmission error, and suppress timing jitter and the identical consecutive digit number. And also we can improve SNR of the optical transmission system about 2dB because of raising total BER at the optical terminal system up to 10.

  • PDF

A study on the Line impedance calculation method in electrified railway system (전기철도에서 급전선로의 line impedance 계산에 관한 연구)

  • Lee, Chun-Bae;Lee, Jong-Woo
    • Proceedings of the KSR Conference
    • /
    • 2004.06a
    • /
    • pp.1308-1312
    • /
    • 2004
  • Transmission line impedance calculation has been tried for obtaining exact value. The method proposed by Carson contains indefinite complex integral. Although the Carson solution is proposed with power series, the solution is limited and valid at special range of frequency. In this paper, we proposed a simplified Carson solution by analytical method using ground transmission line return current. This method calculate the transmission line impedance easily.

  • PDF

A New Reduced-Sized Lumped Distributed Power Divider Using The Shorted Coupled-line Pair (끝이 단락된 결합선로를 이용한 전력 분배기의 초소형화)

  • Kang, In-Ho;Choi, Jae-Kyo
    • Proceedings of the Korea Electromagnetic Engineering Society Conference
    • /
    • 2003.11a
    • /
    • pp.283-287
    • /
    • 2003
  • A new method to miniaturize ${\lambda}/4$ transmission line of power divider is proposed. The method utilizes simple combination of the shorted coupled-line pair instead of the transmission line with very high impedance and shunt lumped capacitors. The length of ${\lambda}/4$ transmission line of power divider is about 16% over the conventional power divider at 1 GHz.

  • PDF

Design of the Broad-Band 3-dB Branch-Line Directional Coupler Using Exponential Transmission Line (지수함수적인 비균일 전송선을 이용한 광대역 3-dB 브랜치라인 방향성 결합기의 설계)

  • 하헌태;김세윤
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.28A no.9
    • /
    • pp.685-691
    • /
    • 1991
  • A broad-band 3-dB directional coupler is implemented by using cascaded exponential transmission line as branch lines. Compared with that of the uniform transmission line, the bandwidth of the proposed 3-dB branch-line directional cpoupler increases 2.96 times.

  • PDF

A Study on Characteristics of the Transmission Line Employing Periodically Perforated Ground Metal on GaAs MMIC and Its Application to Highly Miniaturized On-chip Impedance Transformer Employing Coplanar Waveguide (GaAs MMIC상에서 주기적으로 천공된 홀을 가지는 접지 금속막 구조를 이용한 전송선로 특성연구 및 코프레너 선로를 이용한 온칩 초소형 임피던스 변환기에의 응용)

  • Yun, Young
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1248-1256
    • /
    • 2008
  • In this paper, basic characteristics of transmission line employing PPGM (periodically perforated ground metal) were investigated using theoretical and experimental analysis.According to the results, unlike the conventional PBG (photonic band gap) structures, the characteristic impedance of the transmission line employing PPGM structure showed a real value, which exhibited a very small dependency on frequency. The transmission line employing PPGM structure showed a loss (per quarter wave length) higher by $0.1{\sim}0.2\;dB$ than the conventional microstrip line. According to the investigation of the dependency of RF characteristic on ground condition, the RF characteristic of the transmission line employing PPGM structure was hardly affected by the ground condition in the frequency lower than Ku band, but fairly affected in the frequency higher than Ku band, which indicated that coplanar waveguide employing PPGM structure was optimal for RF characteristic and reduction of size. Considering above results, impedance transformer was developed using coplanar waveguide with PPGM structure for the first time, and good RF characteristics were observed from the impedance transformer. In case that {\lambda}/4$ impedance transformer with a center frequency of 9 GHz was fabricated for a impedance transformation from 20 to10 {\Omega}$, the line width and length were 20 and $500\;{\mu}m$, respectively, and its size was only 0.64 % of the impedance transformer fabricated with conventional microstrip lines. Above results indicate that the transmission line employing PPGM is a promising candidate for a development of matching and passive elements on MMIC.

A Study on Digital Fault Locator for Transmission Line (송전선로용 디지털 고장점 표정장치에 관한 연구)

  • Lee, Kyung-Min;Park, Chul-Won
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.64 no.4
    • /
    • pp.291-296
    • /
    • 2015
  • Transmission line is exposed to a large area, and then faults are likely to occur than the other component of power system. When a fault occurs on a transmission line, fault locator helps fast recovery of power supply on power system. This paper deals with the design of a digital fault locator for improvement accuracy of the fault distance estimation and a fault occurrence position for transmission line. The algorithm of a fault locator uses a DC offset removal filter and DFT filter. The algorithm utilizes a fault data of GPS time synchronized. The computed fault information is transmitted to the other side substation through communication. The digital fault locator includes MPU module, ADPU module, SIU module, and a power module. The MMI firmware and software of the fault locator was implemented.

Analysis of Leakage Current Waveforms for Transmission Line Porcelain Insulators due to ESDD Contamination (ESDD 오손에 따른 송전용자기애자의 누설전류 파형의 분석)

  • Park, Jae-Jun
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.10
    • /
    • pp.1461-1470
    • /
    • 2012
  • This paper reports the contamination performance of transmission line porcelain insulators tested under five different contaminant conditions - clean and ESDD (equivalent salt deposit density) level (A, B, C, and D) through measurement of their leakage current under drop of potential method. To estimate the contamination for transmission line porcelain insulators, leakage current waveform and its maximum value were measured under step-up power test. In the clean insulators test, % distortion factors decreased with increasing step-up power, and as the ESDD level increased, some characteristics such as frequency analysis, harmonics and % distortion facotor could be used for contamination diagnosis of the transmission line porcelain insulators.

A Study for the Equivalent Circuit and Slow-Wave Factor of Defected Ground Structure Transmission Line (DGS 전송선로의 등가회로와 전파지연계수에 대한 재고찰)

  • Lim, Jong-Sik;Koo, Ja-Kyung;Han, Sang-Min;Jeong, Yong-Chae;Ahn, Dal
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2041-2046
    • /
    • 2008
  • A frequency-dependent slow-wave factor (SWF) and equivalent circuit model of transmission line with defected ground structures (DGS) is described. Once S-parameters of a DGS transmission line are given, the conventional frequency -independent equivalent circuit elements are extracted using 3dB cutoff and resonant frequencies (Fc and Fo) as the first step. Using the initial equivalent elements and simple transmission line theories, a frequency-dependent equivalent transmission line model is established through an analytical method, and finally the frequency dependent SWF is calculated. The proposed equivalent circuit model and SWF are frequency-dependent and more reliable because even small insertion loss within available passband is considered, while they have been independent of frequency.

A Study on the Pressure Control of a Pneumatic Pressure Vessel Considering Dynamic Characteristics of Pneumatic Transmission Line (관로부의 동특성을 고려한 공기압 압력용기의 압력제어)

  • Jang, J.S.
    • Journal of Power System Engineering
    • /
    • v.5 no.4
    • /
    • pp.90-96
    • /
    • 2001
  • In this study, a robust controller to control pressure in a pneumatic pressure vessel considering dynamic characteristics of pneumatic transmission line is proposed. Dynamic characteristics of transmission line using compressible fluid is changed by the flowing states of the fluid. So, if the fixed gain controller is designed based on a fixed model, the performance of the control system could be destabilized or degraded. The controller designed in this study is composed of two parts. The one is to reject modelling error based on the disturbance observer, the other is to obtain the control performance. The control results with the designed controller show that the robustness of the control system is achieved regardless of the change of the model of the transmission line. Therefore, the designed controller can be utilized for the performance improvement of the pressure control system using compressible fluid such as air and gas

  • PDF

Series-Gap Characteristics of Polymeric Arrester for Transmission Line (송전선로용 폴리머 피뢰기의 직렬공극 특성)

  • Cho, Han-Goo;Yoo, Dae-Hoon;Lee, Young-Sun;Kim, Jong-Che
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.491-492
    • /
    • 2008
  • This paper describes the series-gap characteristics of transmission line arrester with switching and lightning impulse flashover test. The transmission line arrester exhibited external gap because it is must not flashover with switching impulse on the other hand it is must flashover with lightning impulse. In accordance, minimum and maximum length of series-gap was determinated with these tests. As gap length is increased flashover voltage was increased in the range of 315.4 kV~496.3 kV and negative polarity exhibited a high voltage. As a result, It was thought tat the series-gap length of transmission line arrester exhibited in the range of 580 mm~1100 mm.

  • PDF