• 제목/요약/키워드: transmission line

검색결과 3,297건 처리시간 0.043초

철도 사고현장의 효율적인 동영상 전송 방안에 관한 연구 (A study on effective sending of moving picture from train accident site)

  • 조봉관;장석각
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.289-291
    • /
    • 2003
  • Railway takes an important role of transporting massive passenger and freight. Accidents which occur related to trains have a risk of serious loss of lives, so those accidents need to be controlled urgently Therefore moving picture transmission system is required which transmits exact information of moving picture of accident status to CTC and also communication line is also required with it. By using WTB line as a wayside transmission line, railway telephones, fax and train service information are provided to local offices. As transmission line improving project, optical cabling work is being processed by phases. Therefore optical fiber line is more effective way for a communicating way between stations than coaxial transmission line. This Paper considers connecting method when optical fibers is used for moving picture data transmission of train accidents and its problems.

  • PDF

가공송전선의 송전용량을 증가시키기 위한 동적송전용량 시스템의 설계 (A Design for Dynamic Line Rating System to increase Overhead Transmission Line Capacities)

  • 김성덕
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.72-77
    • /
    • 2011
  • Dynamic Line Rating (DLR) techniques have been greatly worthy of notice for efficiently increasing transmission capacity as well as controlling load-flow in overhead transmission lines, in comparison with the existing power system operating with Static Line Rating (SLR). This paper describes an utilization method to implement DLR control system for old transmission lines built in the first stage using the ground clearance design standard with lower dips. The suggested DLR system is focused on designing as temperature control system rather than current/load control system. Based on several performance for conductor temperatures, it is shown that DLR system with efficiency can be implemented.

부하가 있는 전송 선로의 입력 반사 게수의 스미스 차트 상에서의 쾌적 (On the Loci of the Input Reflection Coefficient of a Loaded Transmission Line on the Smith Chart)

  • 은창수
    • 한국통신학회논문지
    • /
    • 제28권4A호
    • /
    • pp.232-237
    • /
    • 2003
  • 이 논문에서는 부하가 걸려 있는 전송 선로의 길이가 변화할 경우 입력반사 계수가 스미스차트 상에서 그리는 쾌적의 방정식을 유도한다. 결과에 따르면, 전송 선로의 특성 임피던스가 정규화 임피던스와 다를 경우 쾌적은 원을 그리게 되며, 그 원의 중심과 반지름은 부하의 임피던스와 전송 선로의 특성 임피던스에 의해 결정된다. 이 결과는 마이크로스트립 선로를 사용하여 정합 회롤를 설계할 때 선로의 길이와 너비를 조정할 필요가 있을 경우 유용하게 사용될 수 있다.

Electromagnetic Environment of Transmission Line Based on Full Parameter Online Estimation

  • Sun, Zidan;Zhou, Xiaofeng;Liang, Likai;Mo, Yang
    • Journal of Information Processing Systems
    • /
    • 제16권2호
    • /
    • pp.394-405
    • /
    • 2020
  • The parameters of transmission lines have an influence on the electromagnetic environment surrounding the line. This paper proposes a method based on phasor measurement unit (PMU) and supervisory control and data acquisition (SCADA) to achieve online estimation of transmission line full parameters, such as resistance, reactance and susceptance. The proposed full parameter estimation method is compared with the traditional method of estimating resistance independently based on SCADA system. Then, the electromagnetic environment is analyzed based on the different parameter estimation methods. The example results illustrate that online estimation of transmission line full parameters is more accurate in the analysis of electromagnetic environment, which further confirms its necessity and significance in engineering application.

765kV 송전선로 유지.보수 활선공법 고찰 (765kV Transmission maintenance live-line work study)

  • 최한열;민병욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.723-724
    • /
    • 2007
  • Live line work is well known for mending and maintenance of electrical power equipment. Nowadays needs of electric power supply quality require live line work In Korea, live line work is needed since 765kV transmission operation and restructure of electric power industry has changed. In other words, in case of suspension of power supply on the transmission is getting hard to keep up with efficiency of transmission operation, customer's confidence and generation-limited cost. Therefore live line work is very meaningful. As the condition of 765kV Transmission both bare hand and Helicopter live line technique must be used in moderation because of economic, geographical, environmental circumstances around steel tower.

  • PDF

신재생에너지 예측을 위한 송전선로의 계량 데이터 계산 방법 (Calculation Method of Dedicated Transmission Line's Meteological Data to Forecast Renewable Energy)

  • 백자현;김현진;최순호;박상호
    • KEPCO Journal on Electric Power and Energy
    • /
    • 제8권2호
    • /
    • pp.55-59
    • /
    • 2022
  • This paper introduce Renewable Energy forecasting technology, which is a part of renewable management system. Then, calculation method of dedicated transmission line's meteorological data to forecast renewable energy is suggested. As the case of dedicated transmission line, there is only power output data combined the number of renewable plants' output that acquired from circuit breakers. So it is need to calculate meteorological data for dedicated transmission line that matched combined power output data. this paper suggests two calculation method. First method is select the plant has the largest capacity, and use it's meteorological data as line meteorological data. Second method is average with weight that given according to plants' capacity. In case study, suggested methods are applied to real data. Then use calculated data to Renewable forecasting and analyze the forecasting results.

송전선의 강제재폐로 (Forced reclosing in transmission line)

  • 김준현
    • 전기의세계
    • /
    • 제29권6호
    • /
    • pp.401-409
    • /
    • 1980
  • This paper deals with the implementation of forced reclosing the transmission line. Because the ground circuit breaker method decrease the secondary arc current sufficiently, the reclosing time can be reduced. As the secondary arc current is large and its residual time is long in UHV transmission line, this method is more effective in that system. The resistance of ground circuit breaker which minimize the secondary arc current is determined according to the system voltage and the length of transmission line.

  • PDF

765kV 교류 송전선로의 가청소음계산 예측식개발(I) (Predicting formula development of audible noise on a 765kV AC transmission line(I))

  • 이동일;구자윤
    • 대한전기학회논문지
    • /
    • 제45권4호
    • /
    • pp.612-615
    • /
    • 1996
  • Audible noise from corona discharge had been identified as one of the most important factors in the design of conductor configurations for high-voltage transmission lines. 500kV and above. Therefore this paper describes audible noise characteristics of 6 X 480mm conductor bundle in KEPRI 765kV Test Line and Corona Cage. Prediction formula for audible(corona) noise on a 765kV transmission Line was developed using this results.

  • PDF

±500kV HVDC 2회선 송전선로의 전기환경특성 예측 및 평가 (Prediction and Analysis of Electrical Environmental Characteristics under ±500kV HVDC Double Bipole Transmission Line)

  • 우정민;주문노;신구용;권구민;최우정;이재현
    • 전기학회논문지
    • /
    • 제67권4호
    • /
    • pp.554-560
    • /
    • 2018
  • Since Korea has a small land area, it is expected to construct the conductor return type with neutral wire in the case of ${\pm}500kV$ HVDC double bipole transmission line. Therefore, in order to apply ${\pm}500kV$ HVDC double bipole transmission line with neutral wire in Korea, it is necessary to develop technology for insulation and environmental designs. In this study, radio interference, audible noise, electric field and ion current density according to the polarity arrangement were compared and assessed in the ${\pm}500kV$ HVDC double bipole transmission line with the conductor return method. And the optimum configuration of HVDC double bipole transmission line was determined from the viewpoint of electrical environment.

Research on vibration control of a transmission tower-line system using SMA-BTMD subjected to wind load

  • Tian, Li;Luo, Jingyu;Zhou, Mengyao;Bi, Wenzhe;Liu, Yuping
    • Structural Engineering and Mechanics
    • /
    • 제82권5호
    • /
    • pp.571-585
    • /
    • 2022
  • As a vital component of power grids, long-span transmission tower-line systems are vulnerable to wind load excitation due to their high flexibility and low structural damping. Therefore, it is essential to reduce wind-induced responses of tower-line coupling systems to ensure their safe and reliable operation. To this end, a shape memory alloy-bidirectional tuned mass damper (SMA-BTMD) is proposed in this study to reduce wind-induced vibrations of long-span transmission tower-line systems. A 1220 m Songhua River long-span transmission system is selected as the primary structure and modeled using ANSYS software. The vibration suppression performance of an optimized SMA-BTMD attached to the transmission tower is evaluated and compared with the effects of a conventional bidirectional tuned mass damper. Furthermore, the impacts of frequency ratios and SMA composition on the vibration reduction performance of the SMA-BTMD are evaluated. The results show that the SMA-BTMD provides superior vibration control of the long-span transmission tower-line system. In addition, changes in frequency ratios and SMA composition have a substantial impact on the vibration suppression effects of the SMA-BTMD. This research can provide a reference for the practical engineering application of the SMA-BTMD developed in this study.