• 제목/요약/키워드: transient time-response

검색결과 526건 처리시간 0.026초

전단 유동 하에서 전기유변유체의 과도응답 특성 (Transient Response of an Electrorheological Fluid in Shear Flow)

  • 최병하;남윤주;박명관
    • 대한기계학회논문집B
    • /
    • 제33권6호
    • /
    • pp.411-417
    • /
    • 2009
  • The transient shear stress response of an electrorheological fluid is investigated experimentally. The characteristic time constants of an electrorheological fluid sheared between two concentric cylinders were obtained under various electric field strengths and shear rates. Also, two experimental modes are adopted to investigate the effect of the shear flow on the dynamic behavior of the fluid; one is that the electric field is induced before shearing, and the other is the electric field is induced after shearing. From the difference in the response time between two modes, the cluster formation time were obtained. The response times were decreased with the increase of the shear rate, irrelatively of the electric field strength. The cluster formation time were monotonically increased with increase of shear rate, and thereafter, were converged with a certain value.

Transient stochastic analysis of nonlinear response of earth and rock-fill dams to spatially varying ground motion

  • Haciefendioglu, Kemal
    • Structural Engineering and Mechanics
    • /
    • 제22권6호
    • /
    • pp.647-664
    • /
    • 2006
  • The main purpose of this paper is to investigate the effect of transient stochastic analysis on nonlinear response of earth and rock-fill dams to spatially varying ground motion. The dam models are analyzed by a stochastic finite element method based on the equivalent linear method which considers the nonlinear variation of soil shear moduli and damping ratio as a function of shear strain. The spatial variability of ground motion is taken into account with the incoherence, wave-passage and site response effects. Stationary as well as transient stochastic response analyses are performed for the considered dam types. A time dependent frequency response function is used throughout the study for transient stochastic responses. It is observed that stationarity is a reasonable assumption for earth and rock-fill dams to typical durations of strong shaking.

Push-Pull Detection 구조 및 빠른 응답 특성을 갖는 LDO 레귤레이터 (LDO Regulator with Improved Fast Response Characteristics and Push-Pull Detection Structure)

  • 이주영
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.201-205
    • /
    • 2021
  • 본 논문에서는 push-pull 감지 회로 구조로 인해 load transient 특성을 개선시킨 LDO를 제안하였다. LDO 레귤레이터 패스 트랜지스터의 입력단과 내부 오차증폭기의 출력단 사이에 제안된 push-pull 감지 회로 구조로 인한 전압 델타 값의 응답 특성을 개선시켜 종래의 LDO 레귤레이터보다 load transient 특성에서 우수한 효과를 가진다. 기존의 LDO 레귤레이터보다 rising time에서는 약 244 ns, falling time에서는 약 90 ns 만큼의 향상된 응답속도를 가진다. 제안된 회로는 Cadence사의 Spectre, Virtuoso 시뮬레이션 tool을 사용하여 samsung 0.13um 공정으로 특성 및 결과를 시뮬레이션 하였다.

Transient-Performance-Oriented Discrete-Time Design of Resonant Controller for Three-Phase Grid-Connected Converters

  • Song, Zhanfeng;Yu, Yun;Wang, Yaqi;Ma, Xiaohui
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1000-1010
    • /
    • 2019
  • The use of internal-model-based linear controller, such as resonant controller, is a well-established technique for the current control of grid-connected systems. Attractive properties for resonant controllers include their two-sequence tracking ability, the simple control structure, and the reduced computational burden. However, in the case of continuous-designed resonant controller, the transient performance is inevitably degraded at a low switching frequency. Moreover, available design methods for resonant controller is not able to realize the direct design of transient performances, and the anticipated transient performance is mainly achieved through trial and error. To address these problems, the zero-order-hold (ZOH) characteristic and inherent time delay in digital control systems are considered comprehensively in the design, and a corresponding hold-equivalent discrete model of the grid-connected converter is then established. The relationship between the placement of closed-loop poles and the corresponding transient performance is comprehensively investigated to realize the direct mapping relationship between the control gain and the transient response time. For the benefit of automatic tuning and real-time adaption, analytical expressions for controller gains are derived in detail using the required transient response time and system parameters. Simulation and experimental results demonstrate the validity of the proposed method.

회로망 기반의 시간응답 해석에 따른 고전제어와 현대제어의 비교 연구 (Comparative Study on Classical Control and Modern Control via Analysis of Circuit-based Time Response)

  • 민용기
    • 한국전자통신학회논문지
    • /
    • 제12권4호
    • /
    • pp.575-584
    • /
    • 2017
  • 제어시스템의 시간응답을 해석하기 위해 전기회로망을 제안한다. 전달함수와 상태방정식을 이용해 시스템의 시간응답을 계산함으로써 고전제어와 현대제어의 연계성을 분석한다. 상태천이방정식의 복잡한 적분과정을 생략하고, 상태천이행렬과 전달함수의 조합만으로도 시간응답의 해석이 가능함을 제시한다. 단위계단함수와 정현파입력에 따른 전압­전류의 출력응답을 표현하기 위해 프로그램을 코딩하였다. 단위계단입력에서는 과도응답을 해석하였으며, 정현파입력에서는 전압과 전류의 위상차를 해석하였다. 제안된 내용을 과도응답이나 상태공간에 기술함으로써 제어공학의 이해도와 설계능력을 높인다.

특성비 지정법에 의한 시스템 응답속도 및 Overshoot 제어 (The Study of the System Response Time and Overshoot Control using Characteristic Ratio Assignments)

  • 김한실;김대관;노희안
    • 제어로봇시스템학회논문지
    • /
    • 제11권10호
    • /
    • pp.870-879
    • /
    • 2005
  • This paper presents that a transient response can be characterized by certain parameters which are correlated to characteristic polynomial coefficients. These are characteristic ratios and characteristic pulsatances by P. Naslin [4]. We have developed an approach to control directly the transient response. Firstly, speed of the response can be controlled by reconstruction form via multipliable characteristic pulsatances. Secondly, overshoot is controlled by reconstruction form via multipliable characteristic ratios. These formulas can be independently characterized by the system overshoot and the response time to a step input.

THE SENSITIVITY OF STRUCTURAL RESPONSE USING FINITE ELEMENTS IN TIME

  • Park, Sungho;Kim, Seung-Jo
    • Journal of Theoretical and Applied Mechanics
    • /
    • 제3권1호
    • /
    • pp.66-80
    • /
    • 2002
  • The bilinear formulation proposed earlier by Peters and Izadpanah to develop finite elements in time to solve undamped linear systems, Is extended (and found to be readily amenable) to develop time finite elements to obtain transient responses of both linear and nonlinear, and damped and undamped systems. The formulation Is used in the h-, p- and hp-versions. The resulting linear and nonlinear algebraic equations are differentiated to obtain the first- and second-order sensitivities of the transient response with respect to various system parameters. The present developments were tested on a series of linear and nonlinear examples and were found to yield, when compared with results obtained using other methods, excellent results for both the transient response and Its sensitivity to system parameters. Mostly. the results were obtained using the Legendre polynomials as basis functions, though. in some cases other orthogonal polynomials namely. the Hermite. the Chebyshev, and integrated Legendre polynomials were also employed (but to no great advantage). A key advantage of the time finite element method, and the one often overlooked in its past applications, is the ease In which the sensitivity of the transient response with respect to various system parameters can be obtained. The results of sensitivity analysis can be used for approximate schemes for efficient solution of design optimization problems. Also. the results can be applied to gradient-based parameter identification schemes.

  • PDF

Transient response of vibration systems with viscous-hysteretic mixed damping using Hilbert transform and effective eigenvalues

  • Bae, S.H.;Jeong, W.B.;Cho, J.R.;Lee, J.H.
    • Smart Structures and Systems
    • /
    • 제20권3호
    • /
    • pp.263-272
    • /
    • 2017
  • This paper presents the time response of a mixed vibration system with the viscous damping and the hysteretic damping. There are two ways to derive the time response of such a vibration system. One is an analytical method, using the contour integral of complex functions to compute the inverse Fourier transforms. The other is an approximate method in which the analytic functions derived by Hilbert transform are expressed in the state space representation, and only the effective eigenvalues are used to efficiently compute the transient response. The unit impulse responses of the two methods are compared and the change in the damping properties which depend on the viscous and hysteretic damping values is investigated. The results showed that the damping properties of a mixed damping vibration system do not present themselves as a linear combination of damping properties.

수직밀폐형 지중열교환기의 회로 과도해석 상사모델 개발 (Development of an Electric Circuit Transient Analogy Model in a Vertical Closed Loop Ground Heat Exchanger)

  • 김원욱;박홍희;김용찬
    • 설비공학논문집
    • /
    • 제24권4호
    • /
    • pp.306-314
    • /
    • 2012
  • Several numerical or analytical models have been proposed to analyze the thermal response of vertical ground heat exchangers (GHEX). However, most models are valid only after several hours of operation since they neglect the heat capacity of the borehole. Recently, the short time response of the GHEX became important in system simulation to improve efficiency. In this paper, a simple new method to evaluate the short time response of the GHEX by using an analogy model of electric circuit transient analysis was presented. The new transient heat exchanger model adopting the concept of thermal capacitance of the borehole as well as the steady-state thermal resistance showed the transient thermal resistance of the borehole. The model was validated by in-situ thermal response test and then compared with the DST model of the TRNSYS program.

고속응답 $CO_2$ 분석기의 제작 및 이를 이용한 SI 엔진에서의 실시간 배기가스 분석에 관한 연구 (Development of Fast-Response $CO_2$ Analyzer and Analysis of Engine-out Emission during Transient Condition of SI engine)

  • 송현수;민경덕
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.3079-3084
    • /
    • 2008
  • A fast response $CO_2$ analyzer has been developed for measuring the $CO_2$ concentration during transient condition of SI engine. The analyzer is based on the non-dispersive infrared absorption technique, electrical chopping system and water cooling system. The analyzer has good repeatability, linearity and permissible drift characteristic. Besides, it has 18ms with a response to measure the $CO_2$ concentration. The fast response $CO_2$ analyzer was applied to single cylinder SI engine and the $CO_2$ emission was examined during engine start. Simultaneously, the standard exhaust gas analyzer, which has slow response time, was used for considering the engine-out $CO_2$ characteristic. The developed analyzer showed much faster responsive characteristic than that of a standard analyzer and made cycle by cycle exhaust gas analysis possible. The transient engine operating characteristics will be estimated and the transient behaviors on engine-out emission and performance will be improved.

  • PDF