• Title/Summary/Keyword: transient method

Search Result 2,569, Processing Time 0.026 seconds

Transient Power Flow Analysis of Beam and Plate (과도 입력파워에 대한 보와 평판의 파워흐름해석)

  • Hwang, Dae-Woong;Seo, Seong-Hoon;Kwon, Hyun-Wung;Hong, Suk-Yoon
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.17 no.7 s.124
    • /
    • pp.624-631
    • /
    • 2007
  • PFA (power flow analysis) has been recognized as a useful method in vibration analysis of medium-to-high frequency ranges. Until now, PFA method has been developed for steady-state vibration problems. In this paper, PFA method has been expanded to transient problem. New energy governing equations are derived considering time dependent terms in beam and plate. Analytic solutions of those equations are found in simple beam and plate, and are verified by comparing with modal solutions.

Transient Thermoelnstic Analysis of Disk Brakes Using Finite Element Method (유한요소법을 이용한 디스크 브레이크의 과도기 열탄성 해석)

  • Choi, Ji-Hoon;Kim, Do-Hyung;Lee, In;Cha, Hee-Bum;Kang, Min-Gu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.10 no.5
    • /
    • pp.160-167
    • /
    • 2002
  • The transient thermoelastic analysis of automotive disk brakes with frictional contact is performed by using the finite element method. To analyze the thermoelastic behaviors occurring in disk brakes, the coupled heat conduction and elastic equations are solved. The fully implicit transient scheme is used to improve the computation accuracy at every time step. The numerical results of the thermoelastic behaviors are obtained during the repeated braking condition. The computational results show that the thermoelastic instability(TEI) phenomenon(the growth of non-uniformities in contact pressure) occurs in disk brakes. Also, the effect of material properties on the thermoelastic behaviors is investigated to facilitate the conceptual design of the brake system.

To Determine the Characteristic Polynomial Coefficients Based On the Transient Response

  • Haeri, Mohammad;Tavazoei, Mohammad Saleh
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2005.06a
    • /
    • pp.11-15
    • /
    • 2005
  • This paper presents a method to determine the characteristic polynomial of a closed loop all-pole system in order to obtain desired transient response in terms of the overshoot and speed (rising/settling time). The method adjusts the overshoot by doing some changes in the characteristic ratios of the Bessel-Thompson filter. The closed loop speediness is then tuned by suitable choice of the generalized time constant. Simulation results are presented to evaluate the achievements and make comparison with those of a similar method.

  • PDF

Baffled fuel-storage container: parametric study on transient dynamic characteristics

  • Lee, Sang-Young;Cho, Jin-Rae;Park, Tae-Hak;Lee, Woo-Yong
    • Structural Engineering and Mechanics
    • /
    • v.13 no.6
    • /
    • pp.653-670
    • /
    • 2002
  • In order to ensure the structural dynamic stability of moving liquid-storage containers, the flow motion of interior liquid should be appropriately suppressed by means of mechanical devices such as the disc-type elastic baffle. In practice, the design of a suitable baffle requires a priori the parametric dynamic characteristics of storage containers, with respect to the design parameters of baffle, such as the installation location and inner-hole size, the baffle number, and so on. In this paper, we intend to investigate the parametric effect of the baffle parameters on the transient dynamic behavior of a cylindrical fuel-storage tank in an abrupt vertical acceleration motion. For this goal, we employ the ALE (arbitrary Lagrangian-Eulerian) kinematic description method incorporated with the finite element method.

Transient Analysis of Electromagnetic Scattering From Dielectric Objects Using Time-Domain Magnetic Field Integral Equation (시간영역 자장 적분방정식을 이용한 유전체의 전자파 산란 과도해석)

  • 서정훈;정백호;한상호;안현수
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.9
    • /
    • pp.412-417
    • /
    • 2003
  • In this Paper, we propose a time-domain magnetic field integral equation (TD-MFIE) formulation for analyzing the transient electromagnetic response from three-dimensional (3-D) dielectric bodies. The solution method in this paper is based on the Galerkin's method that involves separate spatial and temporal testing procedures. Triangular patch basis functions are used for spatial expansion and testing functions for arbitrarily shaped 3-D dielectric structures. The time-domain unknown coefficients of the equivalent electric and magnetic currents are approximated tv a set of orthonormal basis function that is derived from the Laguerre polynomials. These basis functions are also used for the temporal testing. Numerical results computed by the proposed method are presented and compared.

A Fast Screening Algorithm for On-Line Transient Stability Assessment (온라인 과도안정도 판정을 위한 상정사고 고속 스크리닝 알고리즘 개발)

  • Yang, Jung-Dae;Lee, Jong-Seock;Lee, Byung-Jun;Kwon, Sae-Hyuk;Lee, Koung-Guk
    • Proceedings of the KIEE Conference
    • /
    • 2000.11a
    • /
    • pp.104-106
    • /
    • 2000
  • Transient Stability of a power systems is its ability to maintain synchronous operation of machine when subjected to a large disturbance. This paper presents a new methodology for speed-up transient stability evaluation in SIME. SIME is a hybrid direct method including time simulation to enhance flexibility. The First features of the proposed method are that generator grouping can be performed even in very stable cases and that the stability of a contingency can be evaluated from a short period of time simulation results. The second features of the proposed method are that using power-angle trajectory and subdividing contingency classification have improved the screening capability.

  • PDF

A Study on the Robust Control of Systems Dominantly Subkected to Modeling Errors and Uncertainties (모델링오차와 불확실성을 지배적으로 받는 시스템의 강인한 제어에 관한 연구)

  • 김종화
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.19 no.2
    • /
    • pp.67-80
    • /
    • 1995
  • In order to control systems which are dominantly subjected to modeling errors and uncertainties, control strategies must deal with the effect of modeling errors and uncertainties. Since most of control methods based on system mathematical model, such as LQG/LTR method, have been developed mainly focused on stability robustness, they can not smartly improve the transient response disturbed by modeling errors and/or uncertainties. In this research, a fuzzy PID control method is suggested, which can stably improve the transient responses of systems disturbed by modeling errors as well as systems not entirely using mathematical models. So as to assure the effectiveness of suggested control method, computer simulations are accomplished for some example systems, through the comparison of transient responses.

  • PDF

Development of a New Sensor with Divided Multiple Long and Short Wires in Transient Hot-wire Technique (다수의 분할된 긴 열선과 짧은 열선을 갖는 새로운 비정상열선법 센서개발)

  • Lee, Shin-Pyo;Lee, Myung-Hoon
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.28 no.5
    • /
    • pp.510-517
    • /
    • 2004
  • A fine hot-wire is used both as a heating element and a temperature sensor in transient hot-wire method. The traditional sensor system is unnecessarily big so that it takes large fluid volume to measure the thermal conductivity. To dramatically reduce this fluid volume, a new sensor fabrication and a data processing method are proposed in this article. Contrast to the conventional and most popular two wire sensor, the new sensor system is made up of divided multiple long and short wires. Through validation experiments, it is found that the measured thermal conductivities of the glycerin are exactly same each other between the conventional and proposed new method. Also some technical considerations in arranging the multiple wires are briefly discussed.

Validation Test for Transient Hot-wire Method to Evaluate the Temperature Dependence of Nanofluids (나노유체 열전도율의 온도의존성 평가를 위한 비정상열선법의 시험방법)

  • Kang, Kyoung-Min;Lee, Shin-Pyo
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.31 no.4
    • /
    • pp.341-348
    • /
    • 2007
  • One of the controversial research issues on nanofluids is the temperature dependence of the thermal conductivity of nanofluids, that is, whether it will increase or decrease according to the temperature rise. To evaluate precisely the thermal conductivity behavior of nanofluids, a systematic way of validation experiments for the measuring instrument has been highly recommended. In this paper, procedure of the validation test for transient hot-wire method using the temperature dependence of the base fluids was explained comprehensively and the comparison of the temperature dependence of water-$Al_2O_3$ nanofluids is made between the present work and that of Das et al.

An Improvement of Transient Stability of Multi-machine Power System (다기계통의 과도 안정도 향상)

  • Kim, Soo-Nam;You, Seok-Ku
    • Proceedings of the KIEE Conference
    • /
    • 1997.07c
    • /
    • pp.911-913
    • /
    • 1997
  • This paper presents a method for optima] placement of series capacitors in order to improve the power system transient stability, using genetic algorithms. For the formulation, this paper considers the objective function which is the energy margin as the difference between transient energy and critical energy. The most important factor in determining an accurate critical energy is the controlling unstable equilibrium point (UEP). This paper proposes the controlling UEP methods, concurrently with the DFP(Davidon-Fletcher-Powell) method, which enables the enhancement of multi-machine analysis. The proposed method is applied to 6-bus, 7-line, 4-machine model system to show its effectiveness in determining the locations to install series capacitors and the it's size to be installed in system, simultaneously.

  • PDF