• 제목/요약/키워드: transformers

검색결과 1,166건 처리시간 0.038초

동일한 변압기 사용을 위한 절연형 HBML 인버터 (The study on the HBML inverter using the cascaded transformers)

  • 전장건;박성준;김광헌;임영철;안진우;손무언
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1528-1530
    • /
    • 2004
  • In this paper, an efficient switching pattern to equalize the size of transformer is proposed for a multi-level inverter employing cascaded transformers. It is based on the prior selected harmonic elimination PWM(SHEPWM) method. Because the maximum magnetic flux imposed on each transformer becomes exactly equal each to each, all transformers can be designed with the same size regardless of their position. Therefore, identical full-bridge inverter units can be utilized, thus improving modularity and manufacturability. The fundamental idea of the proposed switching pattern is illustrated and then analyzed theoretically. The validity of the proposed switching strategy is verified by experimental results.

  • PDF

Power Transformer Diagnosis Using a Modified Self Organizing Map

  • Lee J. P.;Ji P. S.;Lim J. Y.;Kim S. S.
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.40-45
    • /
    • 2005
  • Substation facilities have become extremely large and complex parts of electric power systems. The development of condition monitoring and diagnosis techniques has been a very significant factor in the improvement of substation transformer security. This paper presents a method to analyze the cause, the degree, and the aging process power transformers by the Self Organizing Map (SOM) method. Dissolved gas data were non-linearly transformed by the sigmoid function in SOM that works much the same way as the human decision making process. The potential for failure and the degree of aging of normal transformers are identified by using the proposed quantitative criterion. Furthermore, transformer aging is monitored by the proposed criterion for a set of transformers. To demonstrate the validity of the proposed method, a case study is performed and its results are presented.

두개의 변압기와 공진 탱크로 구성된 LLC 공진 컨버터 (LLC Resonant Converter with Two Transformers and Resonant Tanks)

  • 김주훈;강성인;김은수;전용석;이재삼;허동영
    • 전력전자학회논문지
    • /
    • 제14권5호
    • /
    • pp.406-414
    • /
    • 2009
  • 본 논문에서는 전원장치의 고집적화와 저가격화를 위해 두 개의 공진커패시터와 두 개의 변압기로 구성된 독립된 공진탱크회로를 갖는 LLC 공진 컨버터를 제안하였다. 제안된 공진회로에 적용된 두개의 변압기는 각 변압기에 흐르는 전류 불평형문제를 저감하기 위해 1차 측은 병렬 연결되어 있고 2차 측은 상호 직렬 연결되어 있다. 300W 시제품을 제작 실험한 결과를 통해 제안된 LLC 공진컨버터가 적용 가능함을 나타냈다.

공통암 3상 IHMCL 인버터 (3-phase IHCML inverter using common-arm)

  • 송성근;박성준;문채주
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 하계학술대회 논문집
    • /
    • pp.512-514
    • /
    • 2007
  • The number of transformers and the size of transformers in inverter using 3-phase transformer could be reduced compare with a multi-level inverter using single phase transformer. but still the 3-phase transformer inverter needs many switches. In this study, we proposed the isolated multi-level inverter using 3-phase transformers and common arm. Also, the equal-area method is used to calculate conduction angle with switching frequency equal to output fundamental frequency and it can reduce harmonics component of output voltage and switching loss. Finally, We tested multi-level inverter to clarify electric circuit and reasonableness through Matlab simulation and experiment by using prototype inverter.

  • PDF

3상 절연형 변압기를 이용한 다중레벨 (Multi-level Inverter Using 3-Phase isolated Transformers)

  • 이화춘;송성근;박성준;김광헌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 제38회 하계학술대회
    • /
    • pp.1134-1135
    • /
    • 2007
  • In this paper, we proposed the isolated multi-level inverter using 3-phase transformers. It makes possible to use a single DC power source due to employing low frequency transformers. In this inverter, the number of transformer could be reduced comparing with an exiting 3-phase multi-level inverter using single phase transformer. Also, using phase angle control method with switching frequency equal to output fundamental frequency, harmonics component of output voltage and switching losses can be reduced. Finally, we made a prototype inverter to clarify the proposed electric circuit and reasonableness of control signal.

  • PDF

차동전류의 변화율을 이용한 변압기의 여자돌입과 내부사고 구분 알고리즘 (A Discriminating Algorithm between Magnetizing Inrush and Internal Faults of Transformers Using Difference of a differential current)

  • 강용철;이병은;윤재성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2000년도 추계학술대회 논문집 학회본부 A
    • /
    • pp.171-173
    • /
    • 2000
  • This paper presents a discriminating algorithm between magnetizing inrush and internal faults of transformers using difference of a differential current. Incase of inrush, change of magnetizing inductance repeats. Thus, second difference of differential current periodically shows pulse while periodic pulse is not represented in case of internal winding fault. The proposed algorithm is suitable irrespective of the amount of remanent flux.

  • PDF

아파트에서의 동력부하 운전실태 조사 (A Survey on the Load Profiles of the Power Transformers and Motors in Apartment Housing)

  • 이기홍;추성두;정지열;안명선
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.55-59
    • /
    • 2000
  • This paper gives various load profiles of power transformers and motors in apartment housing. The load profile of power transformer shows that it is peaked in winter by heating system, and the maximum value of load profiles in power transformer is ranged 25%∼35%, which shows it is operated on over-capacity. The maximum value of demand factor in water supply system is about 60% and this of wastewater treatment system is about 50%.

  • PDF

전력용 변압기의 절연유가 전계에 미치는 수치해석적 모델 (A Numerical Model of the Electric Field Distribution in Power Transformers)

  • 신판석
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1990년도 하계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 1990
  • The impact of the convected charges, which is caused by the electrification phenomina, in the oil-paper insulation systems of power transformers has been numerically investigated using FEM. The potential distribution of the oil-paper insulation system is assumed to be governed by three equations instead of the classical Laplace equation. When the charge density of oil and the conduction current are kept high, the field distortion or the interrace in a power transformer is considerably distorted due to the convected charges.

  • PDF

원자력발전소의 발전기차단기 설계요건 검토 (Design requirements for Generator Circuit Breaker)

  • 지문구;한성흠
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 하계학술대회 논문집 A
    • /
    • pp.371-373
    • /
    • 2001
  • Main functions of Generator Circuit Breaker(GCB) is cut the generator off from the main transformers and the aux. transformers when plant trip or startup. In this paper, the design requirements For GCB of nuclear power plant is examined. NRC presented the area of review, acceptance criteria and review procedures of GCB in the SRP(Standard Review Plan). In Korea, APR1400 adapted the GCB in main power system.

  • PDF

유중 가스 분석법을 이용한 전력용 유입 변압기의 고장 진단 (A Fault Diagnosis of Oil-Filled Power Transformers Using Dissolved Gas Analysis)

  • 윤용한;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.952-954
    • /
    • 1998
  • This paper presents an artificial neural network approach to diagnose and detect faults in oil-filled power transformers based on dissolved gas analysis. The proposed algorithm is used to detect faults with or without cellulose involved. Several neural network topologies have been considered. Good diagnosis accuracy is obtained with the proposed approach.

  • PDF