• 제목/요약/키워드: transfer system

Search Result 8,703, Processing Time 0.036 seconds

The Development of Equivalent System Technique for Deriving an Energy Function Reflecting Transfer Conductances (선로저항을 반영하는 에너지함수 유도를 위한 등가시스템 기법의 개발)

  • Moon, Young-Hyun;Cho, Byoung-Hoon;Roh, Tae-Hoon;Choi, Byoung-Kon
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.10
    • /
    • pp.1175-1182
    • /
    • 1999
  • This paper shows that a well-defined energy function can be developed to reflect the transfer conductances for multi-machine power systems under an assumption that all transmission lines have uniform R/X rations. The energy function is derived by introducing a pure reactive equivalent system for the given system. In this study, a static energy function reflecting transfer conductances is also derived as well as the transient energy function. The proposed static energy function is applied to voltage stability analysis and tested for various sample systems. The test results show that the accuracy of voltage stability analysis can be considerable improved by reflecting transfer conductances into the energy function.

  • PDF

Effectiveness of a Heat Transfer Characteristics of an Auxiliary Chamber for Performance of an Air Spring (보조용기의 열전달특성이 공기스프링의 성능에 미치는 영향)

  • Jang, Ji-Seong
    • Journal of Power System Engineering
    • /
    • v.17 no.2
    • /
    • pp.121-127
    • /
    • 2013
  • The air spring is used widely because of the easy change of spring constant, and, a superior vibration and shock insulation performance. Among the apparatus using the merits of that, the air spring connected an auxiliary chamber has been developed and used as a component of suspension system for an automobile and a railroad car. The purpose of this study is to suggest a design method reflecting heat transfer effect for an air spring system connected auxiliary chamber. In order to do so, this study investigates change of reaction force along with variations in heat transfer coefficient, and, analyzes an effectiveness of a heat transfer characteristics of an auxiliary chamber for external force attenuation characteristics and impedance characteristics of an air spring connected an auxiliary chamber.

A Comparative Study on ACH and Fedwire as a Cross-Border Payment System (국제전자결제시스템으로서 ACH와 Fedwire의 비교연구)

  • Lee, Byeong-Ryul
    • International Commerce and Information Review
    • /
    • v.10 no.1
    • /
    • pp.139-154
    • /
    • 2008
  • This research want to discuss some issues about payment system of America. This research focuses on comparing ACH with Fedwire. Firstly Fedwire is the payment system for only large-dollar transfer(Large-Value Transfer System; LVTS), while ACH(Automated Clearing House)payment mainly applies a consumer account. Secondly ACH transaction is either credit or debit transfer, while Fedwire is only credit transfer. Thirdly the communication system of Fedwire has twoway method, telephonelike communication network, but ACH is oneway store and forward electronic mail. At present LVTS divides into RTGS(Real-Time Gross Settlement) and DNS(Deferred Net Settlement). However Fedwire uses either RTGS(instantaneous for every transaction) or DNS(net net transaction) but ACH uses only DNS(net net transaction). Fourthly ACH is substantially cheaper than the Fedwire payment. lastly security is important in both Fedwire and ACH, it is even more crucial in Fedwire In addition, for each transaction, Fedwire may entail individual instantaneous confirmation to the originator and notification to the receiver, whereas ACH do not.

  • PDF

The Characteristic analysis of the IPT system used for PRT(Personal Rapid Transmit) (소형궤도차량 유도전력급전 계통 특성해석)

  • Lee, B.S.;Kim, Do-Won;Han, K.H.
    • Proceedings of the KIEE Conference
    • /
    • 2005.04a
    • /
    • pp.218-220
    • /
    • 2005
  • This paper shows the analysis of the inductive power transfer system in conjunction with series resonant converter operating variable high frequency. Of particular interest is the sensitivity of the complete system to variations in operational frequency and parameters. In inductive power transfer system, electrical power is transferred from a prima교 winding in the form of a coil or track, to one or more isolated pick-up coils that may relative to the primary. The ability to transmit power without contact enables high reliability and easy maintenance that allows inductive power transfer system to be implemented in hostile environments. This technology has found application in many fields such as electric vehicles, PRT(Personal Rapid Transit) etc. The coupling between the primary and secondary is then presented to include the effects of parameter and operational frequency variation.

  • PDF

Performance Analysis of a TransferJet System (TransferJet 시스템의 성능분석)

  • Park, Kyung-Won;Wee, Jeong-Wook;Seo, Jeong-Wook;Jeon, Won-Gi
    • Journal of Advanced Navigation Technology
    • /
    • v.16 no.5
    • /
    • pp.810-816
    • /
    • 2012
  • In this paper, BER(Bit Error Ratio) performances of the TransferJet system, which is the standard of a close proximity inductive wireless communication system, are presented and analyzed. Comparing to other wireless communication systems, the TransferJet system has some advantages such as short communication range(i.e., high security in the wireless communication environments), fewer effects of multipath distortion, and higher transmission rate. In order to demodulate the received signal, either SC(Soft-decision Combining) or HC(Hard-decision Combining) can apply to the despreader and demodulator of the receiver. When the spreading factor is more than 4, the SC scheme approximately has a minimum signal-to-noise ratio gain of 2 dB over the HC scheme. Moreover, from simulation results, we can conclude that the quantization bits of 3 bits are an optimum value for the SC scheme in the TransferJet system since the 3-bit quantization achieves nearly the performance as that attained by double-precision floating-point.

Timed-Transfer of Buses (동시환승(Timed-Transfer) 버스시스템)

  • 고승영
    • Journal of Korean Society of Transportation
    • /
    • v.13 no.4
    • /
    • pp.105-115
    • /
    • 1995
  • This paper deals with an operation concept of "time-transfer of buses", in which buses arrive a transfer center at the same time and allow passengers to transfer to other bus lines, so that passengerscan go anywhere all the timed-transfere buses operate with only one transfer. This timed-transfer bus system is known as an efficient operating technique which can be adopted in an area with sparsely distrubuted bus demand. A model of timed-transfer is estabilished in terms of vaious factors such as the expected(or average) arrival time, distribution of arrival time, timed-transfer cycle, shceduled departure time, etc. It is assumed that the objective of timed-transfer bus system is to minimize the total transfer waiting time. The optimal schedualed arrival time or buffer time(time required to arrive ealy in consideration of delay) is analyzed for a general case and various speicial cases. It was found that the optiaml buffer time is an inverse funcion of the timed-transfer cycl and increases with the cycle time, assumin g that there is a fixed scheduled departure time at the transfer cetner regardless of whether one or more buses fail to arrive before the scheduled departure time. If buses are to wait uhtil all the buses arrive at the transfer center, that is, the transfer departure time is vairable, the optimal scheduled arrival times can be obtained by a mathmatical programming.

  • PDF

A Strategy Plan on Development of Railway Technology Transfer Specialist Support System (철도 기술이전 전문가 지원 시스템 개발 기획)

  • Choi, Kyung-Jin;Kim, Sang-Ahm;Kim, Jung-Phyung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.882-887
    • /
    • 2011
  • For many years Korean railway industry has experienced substantial growth based on foreign advanced technology. Recently some problems was clearly stated on effective management, practical use and transfer of the railway technology. This paper presents some results of the study on necessary requirements of the expert system for railway technology transfer. We propose a general plan to develop the expert system and the contents on railway technology transfer in the text of this article.

  • PDF

Acceleration Optimization of a High-speed LCD Transfer Crane Using Finite Jerk (고속 LCD 이송 시스템의 진동감소를 위한 Finite Jerk 적용 가속도 최적화)

  • Song Tae-Jin;Hong Dae-Sun;Kim Ho-Jong;Bang Duck-Je;Chung Won-Jee
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.23 no.3 s.180
    • /
    • pp.110-117
    • /
    • 2006
  • This paper presents the acceleration optimization of a high-speed LCD (Liquid Crystal Display) transfer system for the minimization of vibration. To reduce vibration is one of key requirements for the dynamic control of a high-speed LCD transfer system. In this paper, the concept of finite jerk (the first derivative of acceleration) has been introduced for realizing input acceleration. The profile of finite jerk has been optimized using a genetic algorithm so that vibration effect can be minimized. In order to incorporate a genetic algorithm, the dynamic model of a LCD transfer system which is realized by using the ADAMS software has been linked to the simulation system constructed by the MATLAB. The simulation results illustrated that the duration of finite jerk can be optimized so as to minimize the magnitude of vibration. It has been also shown that the acceleration optimization with finite jerk can make the high-speed motion of a LCD transfer system result in low vibration, compared with the conventional motion control with trapezoidal velocity profile.

Study on Two-Coil and Four-Coil Wireless Power Transfer Systems Using Z-Parameter Approach

  • Seo, Dong-Wook;Lee, Jae-Ho;Lee, Hyung Soo
    • ETRI Journal
    • /
    • v.38 no.3
    • /
    • pp.568-578
    • /
    • 2016
  • A wireless power transfer (WPT) system is usually classified as being of either a two-coil or four-coil type. It is known that two-coil WPT systems are suitable for short-range transmissions, whereas four-coil WPT systems are suitable for mid-range transmissions. However, this paper reveals that the two aforementioned types of WPT system are alike in terms of their performance and characteristics, differing only when it comes to their matching-network configurations. In this paper, we first find the optimum load and source conditions using Z-parameters. Then, we estimate the maximum power transfer efficiency under the optimum load and source conditions, and we describe how to configure the matching networks pertaining to both types of WPT system for the given optimum load and source conditions. The two types of WPT system show the same performance with respect to the coupling coefficient and load impedance. Further, they also demonstrate an identical performance in the two cases considered in this paper, that is, a strong-coupled case and a weak-coupled case.

Effect of Divergence Ratio on Heat Transfer and Friction Factor in the Diverging Channel (확대 채널에서 확대율이 열전달과 마찰계수에 미치는 효과)

  • Oh, Se-Kyung;Lee, Myung-Sung;Jeong, Seong-Soo;Ahn, Soo-Whan
    • Journal of Power System Engineering
    • /
    • v.17 no.1
    • /
    • pp.64-70
    • /
    • 2013
  • The heat transfer and friction factor characteristics of turbulent flows in three stationary channels have been investigated experimentally to check out the effect of divergence ratio. These are a constant cross-sectional channel and two diverging channels with ratio of divergence(Dho/Dhi) of 1.16 and 1.49. The measurement was conducted within the range of Reynolds numbers from 15,000 to 89,000 and the dimension of uniform cross-sectional test section is $100mm{\times}100mm$ at the cross section and 1,000 mm in length. The measurements of heat transfer coefficients and friction factors in the uniform channels were conducted as a reference. Because of the streamwise flow deceleration, the heat transfer and friction factor characteristics in the diverging channel were quite different from those of the constant cross-sectional channel. The effective friction factors and convective heat transfer coefficients increased with increasing the ratio of divergence of the channel.