• Title/Summary/Keyword: transfer length

Search Result 1,310, Processing Time 0.027 seconds

A Study on Combustion and Heat Transfer in Premixed Impinging Flames of Syngas(H2/CO)/Air Part I: Characteristics of Combustion (합성가스(H2/CO)/공기 예혼합 충돌화염의 연소 및 열전달 연구 Part I: 연소특성)

  • Jeong, Byeonggyu;Lee, Yongho;Lee, Keeman
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.47-58
    • /
    • 2014
  • The characteristics of flame shape, laminar burning velocity, emissions and heat flux of stagnation point in premixed impinging jet flame of syngas fuel with 10% hydrogen content were experimentally investigated. Also, the adiabatic temperature and burning velocity are calculated by Chemkin package with USC-II mechanism. The equivalence ratios(0.8~5.0) and dimensionless separation distance(2.0~5.0) with fixed Reynolds number(1800) are main parameters in this work. Different flame shapes and colors were observed for different impingement conditions. The experimental results of burning velocity by flame surface area have a consistent with previous works and numerical simulation of this work. The inner flame length could be predicted with the ratio of mixture velocity and burning velocity from a simple formulation by the laminar burning velocity definition. It has been observed that the heat fluxes at stagnation point are directly affected by the flame shape including the separation distance. The emission results in impinging flame of syngas fuel show that the characteristics of $NO_x$ emission traced well with adiabatic temperature trend and CO emission due to fuel rich condition increased continuously with respect to the equivalence ratio.

Dynamic Adsorptive Characteristics of Dual Adsorbents Bed Packed with Activated Carbon and Zeolite 13X for Benzene Adsorption (활성탄 및 제올라이트 13X를 충진한 이중흡착층 내에서 벤젠의 동적흡착 특성)

  • Kang, Sung-Won;Suh, Sung-Sup;Min, Byung-Hoon
    • Clean Technology
    • /
    • v.10 no.3
    • /
    • pp.159-168
    • /
    • 2004
  • Benzene adsorption experiment was carried out for activated carbon and zeolite 13X adsorbents. Single column and dual column packed with two adsorbents were used to investigate the dynamic adsorptive characteristics. Effect of feed flow rate on the breakthrough curve was not significant. Specific adsorption amount of benzene for activated carbon was larger than that for zeolite 13X. On the contrary, adsorption amount per column volume was larger for zeolite 13X column because the density of zeolite 13X was larger. In the dynamic experiment using dual adsorbents column, length of mass transfer zone was changed by the feed direction. Breakthrough time was longer and breakthrough curve was sharper when activated carbon was packed in feed inlet and zeolite 13X was packed in column outlet. Also breakthrough time and breakthrough curve slope were affected by the packing ratio of the two adsorbents.

  • PDF

Implementation of Bond Slip Effect in Analysis of RC Beams Using Layerd Section Method (적층단면법에 의한 철근콘크리트 보 해석에서의 부착슬립효과)

  • Kim Jin-Kook;Kwak Hyo-Gyoung
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.19 no.1 s.71
    • /
    • pp.1-13
    • /
    • 2006
  • An analytical procedure to analyze reinforced concrete(RC) beams and columns subject to monotonic and cyclic loadings is proposed on the basis of the layered section method. In contrast to the classical nonlinear approaches adopting the perfect bond assumption, the bond slip effect along the reinforcing bar is quantified with the force equilibrium and compatibility condition at the post cracking stage and its contribution is implemented into the reinforcing. The advantage of the proposed analytical procedure, therefore, will be on the consideration of the bond slip effect while using the classical layered section method without additional consideration such as taking the double nodes. Through correlation studies between experimental data and analytical results, it Is verified that the proposed analytical procedure can effectively simulate the cracking behavior of RC beams and columns accompanying the stiffness degradation caused by the bond slip.

A Method for the Preliminary Estimation of Vertical Natural Vibations of High Speed Boats (고속선(高速船) 선체고유상하진동(船體固有上下振動)의 초기추정(初期推定) 방법(方法))

  • K.C.,Kim;H.B.,Kim
    • Bulletin of the Society of Naval Architects of Korea
    • /
    • v.17 no.1
    • /
    • pp.25-29
    • /
    • 1980
  • For the preliminary estimation of the vertical hull natural frequency, the Schlick's or Schlick-type formulae have been traditional ones and are still in common use today. Some investigators have made their efforts, based on statistical data of ships' system parameters, to extend the applicability of Schlick-type formulae to higher modes, or to utilize the Rayleigh method. For instance, the work done by Dinsenbacher et al.[5] belongs to the former and that of Nagamoto et al.[6] to the latter. In a part of his previous paper[7], the author, investigating the case of a cargo ship of medium size, suggested that provided statistically simplified curves such as trapezoid of system parameter distributions are available in hands, direct utlization of an ordinary computer program can be also an another convenient method by which we can obtain both natural frequencies and normal mode shapes. In this paper, to confirm the feasibility of the above suggestion, four high speed boats are investigated. The system parameters of them are originally given in [5]. The computer program used here is one confiled based on a calculation method derived from Myklestal-Prohl modeling of hull, transfer matrix formulation and an extended Gumbel's initial value method for solving frequency equation. The results of the investigation show that the direct calculation based on statistically oriented and reasonably assumed trapezoidal mean curves of system parameter distributions can give us natural frequencies within about 5% deviation up to several-noded modes and normal mode shapes serviceable at least up to 4- or 5-noded modes in comparision with those based on actual distributions of system parameters. For this simplified method the actual data required for input are only of ship length, displacement, total added mass, bending and shear rigidity at amidship. They are available at the early stage of design. By this method we can also easily trace variations of vibration characteristics in the course of ship design cycles.

  • PDF

Cu/Si/Cu Ohmic contacts to n-type 4H-SiC (n형 4H-SiC의 Cu/Si/Cu 오옴성 접합)

  • 정경화;조남인;김민철
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2002.11a
    • /
    • pp.73-77
    • /
    • 2002
  • Characteristics of Cu/Si/Cu ohmic contacts to n-type 4H-SiC were investigated systematically. The ohmic contacts were formed by rf sputtering of multi layer Cu/Si/Cu sputtered sequentially. The annealings were peformed With 2-Step using RTP in vacuum ambient. The specific contact resistivity($\rho$c), sheet resistance(Rs), contact resistance(Rc), transfer length(L$_{T}$) were calculated from resistance(R$_{T}$) versus contact spacing(d) measurements obtained from TLM(transmission line method) structure. Best results were obtained for a sample annealed at vacuum as $\rho$c = 1.0x10$^{-6}$ $\Omega$$\textrm{cm}^2$, Rc = 2$\Omega$ and L$_{T}$ = 1${\mu}{\textrm}{m}$. The physical properties of contacts were examined using XRO and AES. The results showed that copper silicide was formed on SiC and Cu was migrated into SiC.o SiC.

  • PDF

Methane-Steam Reforming Simulation for a High Temperature Solar Chemical Reactor (고온 태양열 화학 반응기에서의 메탄-수증기 개질반응 시뮬레이션)

  • Ko, Jo-Han;Seo, Tae-Beom
    • Journal of the Korean Solar Energy Society
    • /
    • v.29 no.1
    • /
    • pp.44-49
    • /
    • 2009
  • Steam reforming of methane in the high temperature solar chemical reactor bas advantage in its heating method. Using concentrated solar energy as a heating source of the reforming reaction can reduce the $CO_2$ emission by 20% compared to hydrocarbon fuel. In this paper, the simulation result of methane-steam reforming on a high temperature solar chemical reactor(SCR) using Fluent 6.3.26 is presented. The high temperature SCR is designed for the Inha Dish-1, a Dish type solar concentrator installed in Songdo city. Basic SCR performance factors are referred to the former researches of the same laboratory. Inside the SCR porous metal is used for a receiver/reactor. The porous metal is carved like a dome shape on the incident side to increase the heat transfer. Also, ring-disc set of baffle is inserted in the porous metal region to increase the path length. Numerical and physical models are also used from the former researches. Methane and steam is mixed with the same mole fraction and injected into the SCR. The simulation is performed for a various inlet mass flow rate of the methane-steam mixture gas. The result shows that the average reactor temperature and the conversion rate change appreciably by the inlet mass flow rate of 0.0005 kg/s.

A Study for Improving Thermal Performance According to Variables of Perforated Baffle in Air-type PVT Collector (공기식 PVT 컬렉터에 적용된 타공 베플의 변수에 따른 열 성능 향상을 위한 연구)

  • Yu, Ji-Suk;Kim, Jin-Hee;Kim, Jun-Tae
    • Journal of the Korean Solar Energy Society
    • /
    • v.39 no.6
    • /
    • pp.83-91
    • /
    • 2019
  • Photovoltaic thermal (PVT) collectors are devices that simultaneously produce electricity and heat. Research on conventional air-type PVT collector focuses on installing baffles to enhance the collector's thermal performance. However, the baffles have pressure drop inside the collector which degrades the thermal performance. Thus, it is necessary to design baffles to smoothen the flow inside the air-type PVT collector. Alternatively, installing perforated baffles in air-type PVT collectors can reduce the collector weight, but parameters such as the diameter of the perforated holes and the height of the perforated plates should be considered. Therefore, the main aim of this study was to analyze thermal characteristics of each variable of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through NX program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. Therefore, the main aim of this study was to analyze thermal characteristics of each variable (Baffle angle, length, height, pitch, perforated ratio) of perforated baffles installed inside air-type PVT collector. For this purpose, the uniformity of air flow in the collector was compared through CFD program, and the resultant heat gain and thermal efficiency of the air-type PVT collector were compared and analyzed. As a result, the maximum outlet temperature was increased by 1.45 times and the heat gain was increased by 193.8 Wth, depending on the perforated baffle plate, compared to the collector without the baffle. The heat transfer performance showed that the maximum internal velocity was 1.61 times higher and the Reynolds number was 1.06 times higher depending on the parameters of the baffle plate.

Study of Structural Stability for H-section Beams Made of Fire Resistant Steels (FR 490) at High Temperatures by Analytical Method (건축용 내화강재(FR 490) 적용 H형강 보부재의 고온내력 연구)

  • Kwon, In-Kyu
    • Fire Science and Engineering
    • /
    • v.28 no.5
    • /
    • pp.52-57
    • /
    • 2014
  • When structural elements of steel framed structures are exposed to fire situations, the structural stability begins to decrease due to dislocation of substantial. The increase of the beam length causes an additional stress and deflection. These can be serious factors to cause a severe failure of structures. To improve the fire resistance of beams, prevention of the heat from a fire by coating with fire protection material is essential for beams. The FR 490 was developed to enhance fire resistance compared with SM 490 steel. However, the fire resistance of FR 490 H-beams has not been evaluated by analysis method since it was developed. In this paper, materials properties in high temperature and a heat transfer and thermal stress theory were used in the evaluation of the fire resistance of FR490 H-beams. The fire resistance of FR490 steel beams was compared with that of SM490 beams. The comparison verified that the structural stability of FR490 beams at high temperature was superior to that of SM490 beams.

Study on the Design Parameters of a Heat Exchange Steam Reformer (HESR) using CFD (전산유체해석을 이용한 열교환형 수증기 개질기의 디자인 파라미터 연구)

  • YANG, CHANUK;LEE, YULHO;PARK, SANGHYUN;YANG, CHOONGMO;PARK, SUNGJIN
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.1
    • /
    • pp.1-12
    • /
    • 2016
  • In this study, CFD model for a Heat Exchange Steam Reformer (HESR) used for a 10kW SOFC system is developed for the design optimization of the HESR. The model is used to explore the effect of design parameters on the performance of the HESR. In the HESR, heat is delivered from the hot gas channel to the fuel channel to supply the heat required for the fuel reforming. In the fuel channel where the fuel is reformed, thermo-fluid dynamics, heat transfer, and chemical reaction are considered to predict the performance of the reformer. The model is validated with experimental data within 2~3% error. The validated model is used for the parametric study of the HESR design. Channel length, channel diameter, and flow direction are selected as the design parameters. The effects of the HESR design parameters on the outlet temperature, outlet H2 mole fraction, and pressure drop across the reformer are presented using the model.

Analysis of electrical characteristics for p-type silicon germanium metal-oxide semiconductor field-effect transistors (SiGe pMOSFET의 전기적 특성 분석)

  • Ko Suk-woong;Jung Hak-kee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.10 no.2
    • /
    • pp.303-307
    • /
    • 2006
  • In this paper, we have designed the p-type metal-oxide semiconductor field-effect transistor(pMOSFET) for SiGe devices with gate lengths of $0.9{\mu}m$ and $0.1{\mu}m$using the TCAD simulators. The electrical characteristics of devices have been investigated over the temperatures of 300 and 77K. We have used the two carrier transfer models(hydrodynamic model and drift-diffusion model). We how that the drain current is higher in the hydrodynamic model than the drift-diffusion model. When the gate length is $0.9{\mu}m$, the threshold voltage shows -0.97V and -1.15V for 300K and 77K, respectively. The threshold voltage is, however, nearly same at $0.1{\mu}m$ for 300K and 77K.