Abstract

When structural elements of steel framed structures are exposed to fire situations, the structural stability begins to decrease due to dislocation of substantial. The increase of the beam length causes an additional stress and deflection. These can be serious factors to cause a severe failure of structures. To improve the fire resistance of beams, prevention of the heat from a fire by coating with fire protection material is essential for beams. The FR 490 was developed to enhance fire resistance compared with SM 490 steel. However, the fire resistance of FR 490 H-beams has not been evaluated by analysis method since it was developed. In this paper, materials properties in high temperature and a heat transfer and thermal stress theory were used in the evaluation of the fire resistance of FR490 H-beams. The fire resistance of FR490 steel beams was compared with that of SM490 beams. The comparison verified that the structural stability of FR490 beams at high temperature was superior to that of SM490 beams.

구조용 강재는 고온 시 물질 내부의 구성 물질의 결합력 약화로 인하여 내력과 변형이 추가적으로 발생됨으로써, 구조적 성능이 저하되고, 국부 및 연속적 붕괴로 이어질 수 있다. 따라서 강재로 구성된 구조부재는 화재 시 열영향부를 최소화하기 위한 수단이 강구되는 내화설계가 요구된다. 건축용 내화강재(FR 490)는 용접 구조용 강재(SM 490)와 상온시 특성은 동일하나, 고온 시의 내력유지 성능이 우수한 강종으로써 이로 구성된 보부재의 고온 시 내력 평가 자료는 거의 없다. 따라서 본 연구에서는 FR 490강재로 구성된 보부재의 고온 시 거동을 고온 시 재료 특성과 이론적 방법을 통하여 해석적으로 평가하고, 이를 SM 490강재보와 비교함으로써 내화성능을 확인하고자 하였으며, 그 결과 FR 490강재보의 경우 SM 490강재보에 비해서 고온 시 내력유지 성능이 우수하였다.

Keywords

References

  1. Posco Laboratory, "Development of 50 kgf/$mm^{2}$ Fire Resistance Steels using Cr-Mo for Building Structure" (1995).
  2. Korean Standard Association, KS D3865, "Fire Resistance Steels for Building Structure", Seoul, Korea (2011).
  3. Korean Standard Association, KS F 2257-1, "Methods of Fire Resistance Test for Elements of Building Construction-General Requirements", Seoul, Korea (2010).
  4. Y. Sakumoto, T. Yamaguchi, M. Ohash and M. Saito, "High-Temperature Properties of Fire Resistant Steel for Buildings", Journal of Structural Engineering, Vol. 119, pp. 392-407 (1992).
  5. W. Sha, F. S. Kelly and Z. X. Guo. "Microstructure and Properties of Nippon Fire-Resistant Steels", Journal of Materials Engineering and Performance, Vol. 8, pp. 606-612 (1999). https://doi.org/10.1007/s11665-999-0017-3
  6. I. K. Kwon, "Experimental Study on Making Databases for Fire Resistant Steel at High Temperature", Journal of Korean Institute of Fire Science & Engineering, Vol. 27, No. 5, pp. 1-7 (2013). https://doi.org/10.7731/KIFSE.2013.27.5.1
  7. Y. Sakumoto, T. Okada, M. Yoshida and S. Tasaka, "Fire Resistance of Concrete-Filled, Fire-Resistant Steel-Tube Columns", Journal of Materials in Civil Engineering, Vol. 6, No. 2, pp. 169-184 (1994). https://doi.org/10.1061/(ASCE)0899-1561(1994)6:2(169)
  8. Y. Sakumoto, T. Yamaguchi, T. Okada, M. Yoshida, S. Tasaka and H. Saito, "Fire Resistance of Fire-Resistant Steel Column", Journal of Structural Engineering, Vol. 120, No. 4, pp. 1103-1121 (1994). https://doi.org/10.1061/(ASCE)0733-9445(1994)120:4(1103)
  9. K. C. Yang, H. H. Lee and O. Chan, "Experimental Study of Fire-Resistant Steel H-columns at Elevated Temperature", Journal of Constructional Steel Research, Vol. 62, pp. 544-553 (2006). https://doi.org/10.1016/j.jcsr.2005.09.008
  10. K. C. Yang, S. J. Chen, C. C. Lin and H. H. Lee, "Experimental Study on Local Buckling of Fire-Resistant Steel Columns under Fire Load", Journal of Constructional Steel Research, Vol. 61, pp. 553-565 (2005). https://doi.org/10.1016/j.jcsr.2004.07.001
  11. H. Y. Chung, C. H. Lee, W. J. Su and R. Z. Lin, "Application of Fire-Resistant Steel to Beam-to Column Moment Connections at Elevated Temperatures", Journal of Constructional Steel Research, Vol. 66, pp. 289-303 (2010). https://doi.org/10.1016/j.jcsr.2009.09.009
  12. Swedish Institute of Steel Construction, "Fire Engineering Design of Steel Structures", Stockholm, Sweden (1976).