• Title/Summary/Keyword: transfer facility

Search Result 309, Processing Time 0.029 seconds

Delayed Transfer of Major Trauma Patients Under the Current Emergency Medical System in Korea (현재의 국내 응급의료체계에서 중증외상환자의 이송 지연)

  • Jung, Kyoung-Won;Jang, Jeong-Moon;Kim, Ji-Young;Baek, Suk-Ja;Song, Seo-Young;Gang, Chan-Suk;Lee, Kug-Jong
    • Journal of Trauma and Injury
    • /
    • v.24 no.1
    • /
    • pp.25-30
    • /
    • 2011
  • Purpose: Major trauma patients should be transferred to a definitive care facility as early as possible because prompt management will prevent death. This study was designed to discover the obstacles leading to delayed transfers under the current emergency medical system in Korea and whether there are any negative outcomes associated with conducting procedures at primary care hospitals prior to transferring patients to higher levels of care. Methods: The medical records of major trauma patients with an Injury Severity Score above 15 within the past year were reviewed. Patients were divided three groups as follows: (A) came directly to our emergency center, (B) were transferred without CT or MRI scan at the primary care hospital and (C) transferred with CT or MRI scans. The transfer time of each group were compared and analyzed statistically. Additionally, the number and type of imaging performed at the primary care hospital were analyzed. Results: All qualified patients (n=276) were enrolled in this study: 121 patients in group A; 104 in group B; 51 in group C. There was a statistically significant difference in the transfer time between the three groups (p-value<0.001), and 79 (28.6%) were transferred to an emergency medical center within one hour. In group C, CT or MRI scans were performed an average of 1.86 times at the primary care hospital, and the median transfer time was 4 hours 5 minutes. Conclusion: Only 28.6% of the cases in the study arrived within the golden hour at a definitive care facility. Such delays are in part the result of prolonged times at the primary care hospital for radiologic examinations, such as CT or MRI scans. Major multiple trauma patients should be transferred to a definitive care facility directly or as soon as the primary survey and the resuscitation of Advanced Trauma Life Support guideline are completed at the primary care hospital.

A study on Removal of $NH_3$ Gas in a Towar using a Ralu-Pack 250YC as a Packing Material (Ralu-Pack 250YC를 충전한 충전탑에서 암모니아가스 제거에 관한 연구)

  • 김석택
    • Journal of Environmental Science International
    • /
    • v.9 no.5
    • /
    • pp.389-392
    • /
    • 2000
  • In this study a packed tower was selected for the treatment apparatus of $NH_3$ gas produced in industry. Formerly latticework packing has been used in preventive facility of treatment of $NH_3$ gas. However recently metallic Ralu-Pack 250YC. structured packing is usually being used in petrochemical production plant. This study is for the application the packing to the $NH_3$ gas treatment in wet scrubbing process. In Air/water system hydraulic pressure drop dependent of specific liquid load and gas capacity factor was continuous and parallel from graph. The tower height can be determuined by the number of transfer unit and the height of transfer unit influenced on liquid distribution.

  • PDF

Mass Transfer Experiments for the Heat Load During In-Vessel Retention of Core Melt

  • Park, Hae-Kyun;Chung, Bum-Jin
    • Nuclear Engineering and Technology
    • /
    • v.48 no.4
    • /
    • pp.906-914
    • /
    • 2016
  • We investigated the heat load imposed on the lower head of a reactor vessel by the natural convection of the oxide pool in a severe accident. Mass transfer experiments using a $CuSO_4-H_2SO_4$ electroplating system were performed based on the analogy between heat and mass transfer. The $Ra^{\prime}_H$ of $10^{14}$ order was achieved with a facility height of only 0.1 m. Three different volumetric heat sources were compared; two had identical configurations to those previously reported, and the other was designed by the authors. The measured Nu's of the lower head were about 30% lower than those previously reported. The measured angular heat flux ratios were similar to those reported in existing studies except for the peaks appearing near the top. The volumetric heat sources did not affect the Nu of the lower head but affected the Nu of the top plate by obstructing the rising flow from the bottom.

Design of Wireless Rechargeable RTLS Tag (무선 충전 가능한 RTLS 태그 설계)

  • Kim, Tae Yong
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2015.10a
    • /
    • pp.59-60
    • /
    • 2015
  • Wireless power transfer is a technique that supplies the necessary power to the various electronic devices over the air without wires. The technology is classified as near-field wireless power transfer technology using inductive coupling and far-field wireless power transfer technology using antenna. In this paper, RTLS tag for high-precision positioning and wireless power transfer module was designed in order to solve the power supply problem for facility management. was designed for high-precision positioning is possible RTLS tags and wireless charging. The wireless charging pad provides the capability to charge up to four devices using he magnetic resonance system.

  • PDF

The Effect of PVE Oil on the Evaporation/Condensation Heat Transfer Performance of Fin-tube Heat Exchanger (핀-튜브 열교환기에서 PVE오일이 증발/응축 열전달 성능에 미치는 영향)

  • Lee, Hyun-Woo;Jeong, Young-Man;Lee, Jae-Keun;Park, Nae-Hyun
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1067-1072
    • /
    • 2009
  • In vapor compression systems which use refrigerant as a working fluid, the oil is commonly used for compressor lubrication. Since the presence of lubrication oil can change the characteristics properties of refrigerant, the oil affects the heat transfer performance of heat exchanger to a large extent. In this paper, we focus on the effect of PVE oil experimentally on heat transfer performance of the fin-tube heat exchangers which use R410A as a refrigerant. To evaluate the heat transfer performance, the refrigerant to air type test facility chamber has been used. Fin-tube heat exchanger with grooved has been tested while according to the oil mass fraction variation from nearly zero to 1.7 wt%. It was found that the low level of oil mass fraction has an obvious effect on heat transfer performance, while the high level seems no significant influence. The influence of the oil mass fraction to heat transfer performance, however, is different between evaporation and condensation.

  • PDF

Construction of Transportation Facility Database and Design Process for Intermodal Facilities (교통시설 DB구축과 환승시설 설계 적용에 관한 연구)

  • Lim, Mi;Shin, Yong-Eun;Baek, Tae-Kyung
    • Journal of the Korean Association of Geographic Information Studies
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2008
  • Intermodal or transfer facilities is always necessary wherever different modes meet at one place and exchanges of passengers among the modes take place. Design of intermodal or transfer facilities requires a careful consideration of numerous legal and technical factors. This study intends to suggest the fundamental principles needed for design the intermodal facilities to enhance the level-of-service for transfer passengers as well as the efficiency of operation. Previous studies and relevant legal documentation are reviewed and examined. Steps in the design procedures are suggested, and data necessary for designing the facility is suggested. The above principles are applied to the real design of Busan KTX station in order to identify the problems.

  • PDF

Experimental Analysis of Vibration Transfer Characteristics of an Elevated Railroad Station (철도 선하역사 진동 전달 특성의 실험적 분석)

  • Choi, Sanghyun;Yoo, Yong;Kim, Jinho;Kwon, Segon
    • Journal of the Society of Disaster Information
    • /
    • v.11 no.1
    • /
    • pp.89-96
    • /
    • 2015
  • To reduce noise inside an elevated railroad station, the vibration of the station structure should be lowered, and to establish more effective anti-vibration measures it is required that, reflecting the track-bridge-structure interaction, the transfer characteristics of vibration induced by a train is well identified. In this paper, the current status of domestic railroad stations is classified, and the vibration transfer characteristics is analyzed via measurement data from representative elevated stations. From the analysis results on the measurement data, in transferring vibration from the track to the structure, remarkable vibration reduction in higher frequency range is observed, and, in some stations, amplified response characteristics in lower frequency range is identified. Also, for stations with floating track system or TPS type, relatively greater reduction in transferred vibration is observed.

Analysis of Vibration Transfer Characteristics of Approach Bridges for an Elevated Railroad Station (철도선하역사 접속교량의 진동전달 특성 분석)

  • Choi, Sanghyun;Kim, Jin-Ho;Yoo, Yong;Kwon, Se-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.16 no.4
    • /
    • pp.2911-2916
    • /
    • 2015
  • The elevated railway station, above which a train is passing, is vulnerable to noise and vibration compared to other station types. To better identify the vibration characteristics of the elevated railway station, the transferred vibration from approach bridges should be analyzed. In this paper, through experiments and simulations, the transfer characteristics of the vibration from approach bridges is analyzed. The study structure is Geomgok station and the anaylses are conducted using ABAQUS three dimensional numerical model. To identify the change in the transfer characteristics for various bearing types, the analyses are performed considering mechanical properties of bearing for railway bridges. The measurement is performed using the accelerometers attached to the approach bridges and the station structure along the passing path of trains.

Analysis of Flow Characteristics of Forced Ventilated Pre-drying Facility for Mandarin (강제 통풍식 감귤 예건시설의 유동 해석)

  • Kwon, Jin-Kyung;Yun, Hong-Sun;Jeong, Hoon;Lee, Hyun-Dong;Lee, Sung-Hyoun;Moon, Jong-Pil
    • Journal of Biosystems Engineering
    • /
    • v.35 no.6
    • /
    • pp.393-400
    • /
    • 2010
  • Uniform and rapid pre-drying of mandarin is important to improve the storage quality. The aim of this study was to suggest the basic design of forced ventilated pre-drying facility for mandarin by thermal flow analysis using computational fluid dynamics software (FLUENT 6.2). Developed CFD simulation model was verified by comparison with experimental data. Airflows and temperature distributions in the five conceptional designs including existing ordinary temperature storage rooms were analyzed and appropriate basic design was determined. Analysis of the effect of arrangement of windows and exhaust fans on thermal flow in facility was carried out for more detailed design. The results of this investigation showed that the predicted airflow velocity by CFD simulation showed a good agreement with the measured value and optimum design condition for simulated forced ventilated pre-drying facility of mandarin has two exhaust fans and two windows on both sidewalls and cover on loaded mandarin.

Design of muon production target system for the RAON μSR facility in Korea

  • Jeong, Jae Young;Kim, Jae Chang;Kim, Yonghyun;Pak, Kihong;Kim, Kyungmin;Park, Junesic;Son, Jaebum;Kim, Yong Kyun;Lee, Wonjun;Lee, Ju Hahn
    • Nuclear Engineering and Technology
    • /
    • v.53 no.9
    • /
    • pp.2909-2917
    • /
    • 2021
  • Following the launch of Rare Isotope Science Project in December 2011, a heavy ion accelerator complex in South Korea, named RAON, has since been designed. It includes a muon facility for muon spin rotation, relaxation, and resonance. The facility will be provided with 600 MeV and 100 kW (one-fourth of the maximum power) proton beam. In this study, the graphite target in RAON was designed to have a rotating disk shape and was cooled by radiative heat transfer. This cool-down process has the following advantages: a low-temperature gradient in the target and the absence of a liquid coolant cooling system. Monte Carlo simulations and ANSYS calculations were performed to optimize the target system in a thermally stable condition when the 100 kW proton beam collided with the target. A comparison between the simulation and experimental data was also included in the design process to obtain reliable results. The final design of the target system will be completed within 2020, and its manufacturing is in progress. The manufactured target system will be installed at the RAON in the Sindong area near Daejeon-city in 2021 to carry out verification experiments.