• Title/Summary/Keyword: transfer connection

Search Result 439, Processing Time 0.06 seconds

Progressive Collapse-Resistant Rotational Capacity Evaluation of WUF-W Connection by Fracture Index Analysis (파괴지수분석에 의한 WUF-W 접합부의 연쇄붕괴저항 회전능력평가)

  • Kim, Seonwoong
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.22 no.6
    • /
    • pp.353-360
    • /
    • 2018
  • This paper is to investigate the micro-behavior of the double-span beams with WUF-W seismic connection under combined axial tension and moment and to propose the rational rotational capacity of it for progressive collapse-resistant analysis and design addressing the stress and strain transfer mechanism. To this end, the behavior of the double-span beams under the column missing event is first investigated using the advanced nonlinear finite element analysis. The characteristics of fracture indices of double-span beams with WUF-W connection under combined axial tension and flexural moment are addressed and then proposed the rational rotational capacity as the basic datum for the progressive collapse-resistant design and analysis. The distribution of fracture indices related to stress and strain for the double-span beams is investigated based on a material and geometric nonlinear finite element analysis. Furthermore, the micro-behavior for earthquake and progressive collapse is explicitly different.

An Experimental Study on Dry-Connection for Precast Concrete Shear Walls (PC 전단벽 건식접합부에 관한 실험연구)

  • Hong, Sung-Gul;Lim, Woo-Young
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.21-24
    • /
    • 2005
  • In this study, new methods of PC panel connection using 'ㄷ'type steel connection is proposed for highly seismic zone. A study was carry out to investigate the connection behavior subjected to cyclic inelastic loading. Three planar type and two T type PC wall will be tested. The variables will be examined were the shear reinforcement existence of top and bottom walls. The specimens will be tested only reverse cyclic loading in accordance with a prescribed displacement history. To transfer the shear strength shear key set up between top and bottom wall. Failure mode, behavior, ductility and energy dissipation capacity of the specimens constructed by new connections wll be compared with those of monolithic walls and Han's(Han, Jun Hee, Seoul National University) model.

  • PDF

Surgical Treatment of Anomalous Connection of Left Coronary Artery to the Pulmonary Artery [ALCAPA] (주관상동맥-폐동맥 이상연결증의 외과적 수술요법)

  • 이정렬
    • Journal of Chest Surgery
    • /
    • v.26 no.3
    • /
    • pp.228-233
    • /
    • 1993
  • Patients with anomalous connection of the left coronary artery to the pulmonary artery are at risk for myocardial infarction, and early or sudden death. Between 1986 to 1992, a total of 4 of these patients underwent surgical intervention with various operative techniques at our institution. Age at operation ranged from 2 months to 43 years. Three infant patients had congestive heart failure, 2 of them had mitral regurgitaion, and 1 had ST-T change on elctrocardiogram. Operative techniques included direct coronary artery transfer to the aorta[n=2], intrapulmonary tunnel from the aortopulmonary window[n=1], coronary artery bypass using saphenous vein[n=1]. One deaths occured at 2 weeks after direct coronary arterial transfer due to respiratory failure caused by Respiratory Syncitial virus pneumonia. Supravalvar pulmoanry stenosis occured after intrapulmoanry tunnel. We recommend direct aortic implatation of the anomalous coronary artery at the time of diagnosis. Intrapulmonary tunnel from aortopulmonary window or subclavian-coronary anastomosis could be alternatives in whom aortic implantation is not feasible anatomically.

  • PDF

Protocol Behaviors for Multipeer Multimedia Communications

  • Kim, Yong-Woon
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1998.11a
    • /
    • pp.450-455
    • /
    • 1998
  • This paper proposes an enhanced transport protocol for multipeer communications. It is assumed that there exists a transport connection owner that takes the roles of the establishment, management and termination of a transport connection. The proposed protocol classifies the data transfer type into simplex, duplex and N-plex multicasts and provides several transport services to support various requirements in group communications. The general operations and reliability controls of each transfer type are different from one another and carried out by a shared control tree. The QoS negotiation is performed during the creation phase. The notification of negotiated values is followed by an acknowledgment procedure for confirmation. The four-way handshake is introduced. After negotiation, such a resource reservation protocol as RSVP can reserve system and network resources according to the arbitrated values. This paper suggests a conceptual model of the transport layer and its protocol behaviors over the IP multicast and RSVP network.

  • PDF

A study on medium access control protocol and resource assignment mechanism under wireless ATM network (무선 ATM망에서의 매체접근제어 프로토콜 및 자원할당기법에 대한 연구)

  • 성태경;김동일
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.2 no.3
    • /
    • pp.325-333
    • /
    • 1998
  • In this paper, conventional STM(Synchronous Transfer Mode) supports another traffics by using idle channels. Proposed mobile terminals are distributed independently at the BSA(Basic Service Area). So, MAC(Medium Access Control) specified on the wireless ATM networks, which is managing statistics multiplewing functions, idle channel's ultilization is maximized and multimedia service characteristic for conventional wired networks based fixed assignment scheme(connection-oriented) and random assignment scheme(connection-oriented) improving on dynamic reservation based MAC protocol.

  • PDF

Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers (핀-관 열교환기에서 개별 열의 열전달 효과)

  • Jeong, Ji-Hwan;Chang, Keun-Sun;Lee, Hyun-Woo
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.238-244
    • /
    • 2003
  • An experimental study was performed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance was measured using air-enthalpy type calorimeter. The examined heat exchangers consists of $7{\Phi}$ tube and fin patterns of them are slit and louver types. Equivalent fin spacing are 18 FPI for all samples, and the number of tube rows were 2. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers were used. The frontal air velocity varied from 0.7 to 2.5 m/s. Heat transfer performance for each row are measured. It was observed that the heat transfer coefficient of the 2nd row were smaller than that of the 1st row at low Reynolds number while larger at high Reynolds number.

  • PDF

Heat Transfer Performance of Individual Rows in Fin-Tube Heat Exchangers (2열 핀-관 열 교환기의 열별 전열성능 측정)

  • 권영철;정지환;장근선;홍기수;진심원
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.16 no.3
    • /
    • pp.280-286
    • /
    • 2004
  • An experimental study is peformed to examine the heat transfer performance of individual rows of fin-tube heat exchangers. The heat transfer performance is measured using an air-enthalpy type calorimeter. The examined heat exchangers consist of 7mm tube and fin patterns of them are slit and louver types. Equivalent fin spacings are 18 fins per inch(fpi) for all samples, and the number of tube rows are two. In order to confirm that thermal boundary condition on fins of each row are the same, physically separated between two rows as well as connected heat exchangers are used. The frontal air velocity is varied from 0.7 to 2.5㎧. Heat transfer performance for each row is measured. It is observed that the heat transfer coefficient of the second row is smaller than that of the first row at low Reynolds number while larger at high Reynolds number.

Subway Line 9 Express Transit Service & Direct Link Proposal with Line 5 (뉴스초점 - 지하철 9호선의 급행화 및 5호선과의 직결대안)

  • Lee, Sun
    • Journal of the Korean Professional Engineers Association
    • /
    • v.42 no.3
    • /
    • pp.41-46
    • /
    • 2009
  • A new subway, line 9 linking Western and Eastern Seoul began its services for citizens between Gimpo airport and Gangnam area within 30 minutes by express transit service. Seoul Metro Line 9 Corporation plans to operate both local transit service which will stop at every station, and express transit service that will stop at several key stations including junctions. The passengers on line 9 will be able to transfer to lines 2, 3, 5, 8, Bundang and Incheon International Airport. The Line 9 is expected to disperse the demand for line 2, having the most number of subway users, and will provide passengers with less crowded travel. The new line will also help residents in southern Seoul outskirts and Gyeonggi provincial cities including Bundang vicinity, and Gangdong area commuters get better access to Gimpo and incheon Airports. The Corporation expects to transfer 560,000 passengers daily by the subway line 9. Seoul Development Institute conducted network reshuffle study for Seoul Metro system to sort out congestion problem due to its irrational line alignments and inconvenient transfer. Among several candidate plans of network reshuffling, the direct connection of line 9 with line 5 was chosen as a pilot study. The study found that direct connection of the 2 lines is essential for enhancing transit utility and reducing automobile commuters.

  • PDF

Re-evaluation of Force Transfer Mechanism of Welded Steel Moment Connections (용접 철골 모멘트접합부의 응력전달 메커니즘 재평가)

  • Lee, Choel-Ho
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.9 no.2 s.42
    • /
    • pp.59-69
    • /
    • 2005
  • Employing the classical beam theory for the design of welded steel moment connections has been brought into question by several researchers since the 1994 Northridge earthquake. In this study, the load transfer mechanism in various welded steel moment connections is comprehensively reviewed mainly based on recent studies conducted by the writer. Available analytical and experimental results showed that the load path in almost all the welded steel moment connections is completely different from that as predicted by the classical beam theory. Vertical plates near the connection such as the beam web, the web of the straight haunch, and the rib act as a strut rather than following the classical beam theory. The shear force transfer in the RBS connection is essentially the same as that in PN type connection. Some simplified analytical models that can be used as the basis of a practical design procedure are also presented.

TCP Engine Design for TCP/IP Hardware Accelerator (TCP/IP Hardware Accelerator를 위한 TCP Engine 설계)

  • 이보미;정여진;임혜숙
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5B
    • /
    • pp.465-475
    • /
    • 2004
  • Transport Control Protocol (TCP) has been implemented in software running on CPU in end systems, and the protocol processing has appeared as a new bottleneck due to advanced link technology. TCP processing is a critical issue in Storage Area Network (SAN) such as iSCSL, and the overall performance of the Storage Area Network heavily depends on speed of TCP processing. TCP Engine implemented in hardware reduces the load of CPU in end systems as well as accelerates the protocol processing, and hence high speed data processing is achieved. In this paper, we have proposed a hardware engine for TCP processing. TCP engine consists of three major block, TCP Connection block Rx TCP block and Tx TCP block TCP Connection block is responsible for managing TCP connection states. Rx TCP block is responsible for receive flow which receives packets from network and sends to CPU. Rx TCP performs header and data processing and sends header information to TCP connection block and Tx TCP block It also assembles out-of-ordered data to in-ordered before it transfers data to CPU. Tx TCP block is responsible for transmit flow which transfers data from CPU to network. Tx TCP performs retransmission for reliable data transfer and management of transmit window and sequence number. Various test-cases are used to verify the TCP functions. The TCP Engine is synthesized using 0.18 micron technology and results in 51K gates not including buffers for temporal data storage.