• Title/Summary/Keyword: transducers

Search Result 855, Processing Time 0.022 seconds

Microstructure and Piezoelectric Properties in the (Na,K,Li)(Nb,Sb)$O_3$ system ((Na,K,Li)(Nb,Sb)$O_3$ 세라믹스의 압전특성과 미세조직의 변화)

  • Jeon, So-Hyun;Kim, Min-Soo;Jeong, Soon-Jong;Kim, In-Sung;Min, Bok-Ki;Song, Jae-Sung
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.280-280
    • /
    • 2007
  • Lead oxide-based ferroelectrics are the most widely used materials for piezoelectric actuators, sensors and transducers due to their excellent piezoelectric properties. Considering lead toxicity, there is great interest in developing lead-free piezoelectric materials, which are biocompatible and environmentally friendlier. Recently alkali oxide materials, including sodium - potassium niobate (NKN), have been given attention in view of their ultrasonic application and also as promising candidates for piezoelectric lead-free system. However, it is difficult to sinter such NKN-based materials via conventional sintering process. In this reason, many researchers have investigated hot press, hot isostatic press or spark-plasma sintering of NKN-based ceramics. In this study, as candidates for lead-free piezoelectric materials, dense (Na,K,Li)(Nb,Sb)$O_3$ systems were developed by conventional sintering process. The microstructures and piezoelectric properties of the (Na,K,Li)(Nb,Sb)$O_3$ systems were investigated as a function of variable compositions. The excellent piezoelectric and electromechanical properties indicate that this system is potentially good candidate as lead-free material for a wide range of electro-mechanical transducer applications.

  • PDF

Experimental Analysis of Prestressed Approach Slab Behavior (프리스트레스가 도입된 접속슬래브의 실험적 거동 분석)

  • Park, Hee-Beom;Eum, In-Sub;Kim, Seong-Min
    • International Journal of Highway Engineering
    • /
    • v.12 no.4
    • /
    • pp.157-164
    • /
    • 2010
  • This research was conducted to analyze the behavior of Single-PTAS (Single Post-Tensioned Approach Slab) under tensioning and environmental loads by performing field tests when the demonstration Single-PTAS was being constructed. The temperature measurement sensors were installed at different depths, and the displacements in the approach slab under environmental loads and tensioning were measured using displacement transducers. As an experimental result, an abrupt change in the longitudinal displacement due to tensioning was not observed. The daily temperature change in the approach slab was negligible where the depth is over about 35cm. The temperature gradient in the approach slab adjacent to bridge was smaller than that adjacent to pavement. The patterns and magnitudes of vertical displacements were directly related to the temperature gradient at the measuring location. The behavior of Single-PTAS was very similar to that of concrete pavement. Therefore, a new design methodology for approach slabs is needed to include the pavement concept and to overcome drawback of current design procedures based on the simple beam concept.

Field Measurement and Analysis of Post-Tensioned Prestressed Concrete Pavement Behavior under Tensioning (현장실험을 통한 포스트텐션드 프리스트레스트 콘크리트 포장의 긴장 시 거동분석)

  • Park, Hee-Beom;Kim, Seong-Min;Kim, Dong-Ho
    • International Journal of Highway Engineering
    • /
    • v.11 no.1
    • /
    • pp.247-256
    • /
    • 2009
  • This research was conducted to analyze the behavior of PTCP (Post-Tensioned prestressed Concrete Pavement) under tensioning by performing field tests when the experimental PTCP slab was being constructed. The displacements in the slab under the environmental loading and tensioning were measured using temperature measurement sensors and displacement transducers. Tensioning was performed three times and appropriateness of tensioning could be determined by investigating the relationship between temperature and displacement, behavior of transverse crack, and daily change in displacement. The results of this study showed that under the first tensioning at very early age, large displacements were observed only near the joints because of the friction between slab and underlying layer and concrete inelasticity. Under consecutive tensioning, displacements were clearly observed all over the slab, but still affected by the friction. In addition, appropriate tensioning ensured the one-slab behavior of the PTCP slab even though cracks existed.

  • PDF

Effect of Kinetic Degrees of Freedom on Hierarchical Organization of Multi-element Synergies during Force Production and Releasing Tasks

  • Kim, Kitae;Song, Junkyung;Park, Jaebum
    • Korean Journal of Applied Biomechanics
    • /
    • v.30 no.2
    • /
    • pp.131-144
    • /
    • 2020
  • Objective: The purpose of this study was to examine the effect of degrees of freedom on the multi-synergies in two hierarchies of human hand system during force production and releasing tasks. Method: In this study, the constrained movements of the aiming and releasing actions using both hands and fingers during archery-like shooting were implemented as experimental tasks. The participants produced a pulling force holding the customized frame (mimicking an archery bow, with a set of force transducers) and kept it consistently for about 5 seconds, and released fingers as quickly as possible in a self-paced manner within the next 5 seconds. An analytical method based on the uncontrolled manifold hypothesis was used to quantify the stability index (synergy index) in two hierarchies including two hands (upper hierarchy) and individual fingers (lower hierarchy). Results: The results confirmed that the positive synergy pattern showed simultaneously at the upper and lower hierarchies, and the kinetic degrees of freedom were associated with the increment of hierarchical synergy indices and the performance indices. Also, the synergy indices of both hierarchies showed significant positive correlations with the performance accuracy during the task. Conclusion: The results of this study suggest that the human control system actively uses extra degrees of freedom to stabilize task performance variables. Further increasing the degree of freedom at one level of hierarchy induces positive interactions across hierarchical control levels, which in turn positively affects the accuracy and precision of task performance.

Inhibitory Action of Oxymetazoline on Movements of The Isolated Strips of Rabbit Small Intestine ; A Comparison of Recordings Through Isotonic Transducer and Through Isometric Transducer (Oxymetazoline의 가토장편운동(家兎腸片運動) 억제작용(抑制作用) 등장성(等張性) 및 등장성(等張性) 기록방법(記錄方法)의 비교(比較))

  • Shin, Dong-ho;Choi, Soo-hyung
    • Korean Journal of Veterinary Research
    • /
    • v.25 no.1
    • /
    • pp.33-40
    • /
    • 1985
  • The inhibitory action of oxymetazoline on the spontaneous movements of isolated intestinal strips of the rabbit and the effects of antagonists upon the oxymetazoline actions were assessed with recordings through both isometric and isotonic transducers, and comparisons were made between both methods of recording. There were significant differences between the slopes of regression equations calculated from log dose response curves of oxymetazoline obtained from jejunum and those from ileum. But no difference was noted between both recordings either through isotonic transducer or through isometric transducer. The $ID_{50}$ of oxymetazoline obtained from the recording through isotonic transducer was $6.31{\times}10^{-7}M$ in jejunum and $3.16{\times}10^{-8}M$ in ileum. The recording through isometric transducer gave the values of $5.01{\times}10^{-7}M$ in jejunum and $1.07{\times}10^{-8}M$ in ileum. The $pA_2$-values of prazosin to oxymetazoline calculated from the recording through isotonic transducer were 8.13 in jejunum and 8.31 in ileum and the recording through isometric transducer gave the values of 7.29 and 8.26 in jejunum and ileum, respectively. The $pA_2$-values of phentolamine to oxymetazoline obtained from the recording through isotonic transducer were 8.18 in Jejunum and 9.31 in ileum and those from the recording through isometric transducer were 7.75 and 8.13 in jejunum and ileum, respectively. These results indicate that there are no significant differences between recordings either through isotonic transducer or through isometric transducer in assessing inhibitory responses of intestinal movement to certain drugs.

  • PDF

Rhizoma Coptidis INHIBITS HISTAMINE-INDUCED CONTRACTILE RESPONSES OF AIRWAY SMOOTH MUSCLE (기관지(氣管支) 평골절(平滑筋)에 미치는 황연(黃連)의 효과(效果))

  • O, Kwang-Soo;Han, Jong-Hyun
    • The Journal of Internal Korean Medicine
    • /
    • v.18 no.2
    • /
    • pp.83-93
    • /
    • 1997
  • Rhizoma Coptidis, a traditional herb medicine, has been used in Korea and China for many centuries as a treatment for many disease. The purpose of the present study was to determine the effect of Rhizoma Coptidis on histamine-induced tracheal smooth muscle contraction in guinea pigs and rats. Guinea pigs(500g, male) and rats(250g, male) were killed by $CO_2$ exposure and a segment (8-10mm) of the thoracic trachea from each guinea pig was cut into equal segments and mounted 'in pairs' in a tissue bath. Contractile force was measured with force displacement transducers under 0.5g loading tension. The dose of histamine which evoked 50% of maximal response ($ED_{50}$) was obtained from cumulative dose response curves for histamine ($10^{-7}-10^{-3}M$). Contractions evoked by histamine($ED_{50}$) were inhibited significantly by Rhizoma Coptidis. The mean percent inhibition was 33.2% after 1.5mg/ml Rhizoma Coptidis, and 69.5% after 5.0mg/ml Rhizoma Coptidis in guinea pigs, and the mean percent inhibition was 25.3% after 1.5mg/ml Rhizoma Coptidis, and 65.8% after 5.0mg/ml Rhizoma Coptidis in rats. Indomethacin ($10^{-7}M$) slightly but significantly attenuated the inhibitory effects of Rhizoma Coptidis. But propranolol and methylene blue ($10^{-7}M$) did not significantly alter the inhibitory effect of Rhizoma Coptidis. These results indicate that Rhizoma Coptidis can relax histamine-induced contraction of guinea pig and rat tracheal smooth muscle, and that this inhibition involves, in part, cyclooxygenese inhibitor.

  • PDF

A Development of an Insole Type Local Shear Measurement Transducer and Measurements of Local Plantar Shear Force During Gait (인솔형 국부 전단센서의 개발 및 보행 시 발바닥의 국부 전단력 측정)

  • Jeong Im Sook;Ahn Seung Chan;Yi Jin Bok;Kim Han Sung;Kim Young Ho
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.22 no.6 s.171
    • /
    • pp.213-221
    • /
    • 2005
  • An insole type local shear force measurement system was developed and local shear stresses in the foot were measured during level walking. The shear force transducer based on the magneto-resistive principle, was a rigid 3-layer circular disc. Sensor calibrations with a specially designed calibration device showed that it provided relatively linear sensor outputs. Shear transducers were mounted on the locations of four metatarsal heads and heel in the insole. Sensor outputs were amplified, decorded in the bluetooth transmission part and then transferred to PC. In order to evaluate the developed system, both shear and plantar pressure measurements, synchronized with the three-dimensional motion analysis system, were performed on twelve young healthy male subjects, walking at their comfortable speeds. The maximum peak pressure during gait was 5.00kPa/B.W at the heel. The time when large local shear stresses were acted correlated well with the time of fast COP movements. The anteroposterior shear was dominant near the COP trajectory, but the mediolateral shear was noted away from the COP trajectory. The vector sum of shear stresses revealed a strong correlation with COP movement velocity. The present study will be helpful to select the material and to design of foot orthoses and orthopedic shoes for diabetic neuropathy or Hansen disease.

Numerical Analysis of Ultrasonic Beam Profile Due to the Change of the Number of Piezoelectric Elements for Phased Array Transducer (Phased Array트랜스듀서에 있어서 구성 압전소자수의 변화에 따른 초음파 빔 전파 특성의 수치 해석)

  • Choi, Sang-Woo;Lee, Joon-Hyun
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.19 no.3
    • /
    • pp.207-216
    • /
    • 1999
  • A phased array is a multi-element piezoelectric device whose elements are individually excited by electric pulses at programmed delay time. One of the advantages of using phased array in nondestructive evaluation (NDE) application over conventional ultrasonic transducers is their great maneuverability of ultrasonic beam. There are some parameters such as the number and the size of the piezoelectric elements and the inter-element spacing of the elements to design phased array transducer. In this study, the characteristic of ultrasonic beam for phased array transducer due to the variation of the number of elements has been simulated for ultrasonic SH-wave on the basis of Huygen's principle. Ultrasonic beam directivity and focusing due to the change of time delay of each element were discussed due to the change of the number of piezoelectric elements. It was found that ultrasonic beam was much more spreaded and hence its sound pressure was decreased as steering angle of ultrasonic beam was increased. In addition, the ability of ultrasonic bean focusing decreased gradually with the increase of focal length at the same piezoelectric elements. However, the ability of beam focusing was improved as the number of consisting elements was increased.

  • PDF

Time-Frequency Analysis of Dispersive Waves in Structural Members Under Impact Loads (시간-주차수 신호처리를 이용한 구조용 부재에서의 충격하중에 의한 분석 파동의 해석)

  • Jeong, H.;Kwon, I.B.;Choi, M.Y.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.6
    • /
    • pp.481-489
    • /
    • 2000
  • A time-frequency analysis method was developed to analyze the dispersive waves caused by impact loads in structural members such as beams and plates. Stress waves generated by ball drop and pencil lead break were recorded by ultrasonic transducers and acoustic emission (AE) sensors. Wavelet transform (WT) using Gabor function was employed to analyze the dispersive waves in the time-frequency domain, and then to find the arrival time of the waves as a function of frequency. The measured group velocities in the beam and the plate were compared with the predictions based on the Timoshenko beam theory and Rayleigh-Lamb frequency equations, respectively. The agreements were found to be very good.

  • PDF

A Study of the Development of PC-Based Source Location System using Acoustic Emission Technique (음향방출기법을 이용한 PC기반 위치표정시스템 개발에 관한 연구)

  • Lee, M.R.;Lee, J.H.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.23 no.3
    • /
    • pp.205-211
    • /
    • 2003
  • Acoustic emission (AE) technique has been applied to not only mechanical property testing but also on-line monitoring of the el)tire structure or a limit zone only. Although several AE devices have already been developed for the on-line monitoring, the price of these systems is very high and it is difficult for the field to apply yet. In this study, wc developed a specially designed PC-based source location system using the A/D board. The source location technique is very important to identify the source, such as crack, leak detection. However, since the AE waveforms obtained from transducers are very difficult to distinguish the defect signals, therefore, it is necessary to consider the signal analyses of the transient waveform. Wavelet Transform (WT) is a powerful tool for processing transient signals with temporally varying spectra that helps to resolve high and low frequency transients components effectively In this study, the analyses of the AE signals are presented by employing the WT analyses. AE results are compared the PC-based source location system using A/D board with the commercial AE system.