• 제목/요약/키워드: tracking resistance

검색결과 184건 처리시간 0.026초

컨테이너박스용 용접선 추적거동에 관한 연구 (A Study on the Seam Tracking Behavior for container box's welding)

  • 안병원;배철오;김현수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • 제30권3호
    • /
    • pp.438-443
    • /
    • 2006
  • The probe type sensor using strain gauges was used to track a container box's seam in this paper. A strain gauge has a property which the specific resistance is changed by varying of the sectional area and length when tensile and compressive stresses are generated at the strain gauge. We designed the automatic seam tracking device by attaching the probe type strain gauge sensor, motor driving slide, encorder to check the moving distance and interface card connected MPU upside the speed controllable carriage. The folded work piece for a container box is made to examine whether the device can track the seam automatically or not. Seam tracking experiments were done by changing the carriage moving speed at 300. 400. 500. 600[mm/min] each as the voltage of side track was 2.5[V]. We compared and analyzed the sampling data which is obtained by output voltage of strain gauge sensor and rotary encorder pulse every 100 [m/s]. The welding experiments were performed by using $CO_2$ welding machine about the carriage moving speed that has good seam tracking condition in the seam tracking experiments above. And we compared the seam tracking status.

누전차단기 외함 전원측 단자사이의 트래킹에 의한 탄화특성 분석 (The Analysis of the Carbonization Properties between RCD Source Terminals Deteriorated by Tracking)

  • 최충석;송길목;김동우
    • 한국화재소방학회논문지
    • /
    • 제17권4호
    • /
    • pp.13-19
    • /
    • 2003
  • 본 논문은 누전차단기 외함 전원측 단자사이에서 발생하는 전기화재 원인에 대한 분석을 연구하였다. 누전차단기는 보호범위의 전기시설물에서 누전 또는 과부하에 의한 차단을 목적으로 한다 누전차단기의 전원측 단자는 트래킹에 의해 화재로 쉽게 이어질 수 있다. 따라서, 누전차단기의 재현실험을 통해 트래킹시료($E_1$)와 화재현장에서 트래킹된 것($S_1$)을 비교분석하여 전기화재의 원인을 밝히는데 중요한 자료가 되도록 하였다. 실험은 IEC Publ. 112법을 응용하여 실시하였고 누전차단기에서 미소방전과 건조대가 발생한 후 소손되는 것을 확인하였다. $_1$에서 전원측 단자간의 절연저항은 약 25.7Ω이고 $S_1$의 절연저항은 약 58.6Ω이었다. $E_1$의 발열피크는 $491.0^{\circ}C$$603.2^{\circ}C$였다. $603.2^{\circ}C$에서의 발열피크는 트래킹에 의한 것이다. $S_1$의 발열피크는 $593.1^{\circ}C$에서 나타났다. 트래킹에 의해 변화된 시료는 IR 흡수스펙트럼에서 $1590 cm^{-1}$ 에서 흡광피크가 나타나지 않았다.

정수기용 압축기의 안전성 평가 및 소손 패턴 분석에 관한 연구 (A Study on the Safety Assessment and Damage Pattern of Water Purifier Compressors)

  • 최충석
    • 한국안전학회지
    • /
    • 제28권2호
    • /
    • pp.21-25
    • /
    • 2013
  • The purpose of this study is to provide basic data for the safety assessment of a water purifier when water leaks due to inappropriate maintenance and the examination of the cause of accidents related to the leak. Due to its inspection and management by non-specialists, if a leak occurs in a water purifier with the water level controller being inclined, it may result in the failure of the compressor, power supply line, PCB, etc. The analysis of the thermal diffusion pattern of water purifier compressors using a thermal image camera shows that its maximum temperature was approximately $80^{\circ}C$. In addition, its operating current was a maximum of 13 A and the system's operating current was approximately 1.7 A after the compressor was charged. It was found that the housing type power cable cover of the compressor had the effect of preventing electric shock but has poor flame resistance. Furthermore, the performance of the overload protector, PTC relays, etc., was excellent but they have potential for problems as metallic terminals were exposed, resulting in the potential of a safety related accident. The terminals and their surface damaged by the tracking showed a trace of carbonization and the resistance between terminals was measured to be approximately $8{\Omega}$. In addition, while the tracking was proceeding, the fuse and circuit breaker installed for system protection did not operate.

커패시턴스 내부저항을 고려한 태양광용 Boost 컨버터에 대한 MPPT 제어 알고리듬 고찰 (A Study of MPPT Control Algorithm for Boost Converter of Photovoltaic System Considering Capacitor Equivalent Series Resistance)

  • 최주엽;유권종;이동기;이기옥;정영석;김기현
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 추계학술대회 논문집
    • /
    • pp.109-114
    • /
    • 2001
  • Photovoltaic systems normally use a maximum power point tracking (MPPT) technique to continuously deliver the highest possible power to the load when variations in the insolation and temperature occur. A simple method of tracking the maximum power points (MPPs) and forcing the boost converter system to operate close to these points is presented through deriving small-signal model and transfer function of boost converter. This paper aims at modeling boost converter including equivalent series resistance of input reservoir capacitor by state-space-averaging method. In the future, properly designed controller for compensation will be constructed for maximum photovoltaic power tracking control.

  • PDF

최대전력점추적방법과 외부저항 제어 알고리즘을 이용한 미생물연료 전지의 전력생산 최대화 (Improvement of Power Generation of Microbial Fuel Cells using Maximum Power Point Tracking (MPPT) and Automatic Load Control Algorithm)

  • 송영은;김중래
    • KSBB Journal
    • /
    • 제29권4호
    • /
    • pp.225-231
    • /
    • 2014
  • A microbial fuel cell (MFC) and bioelectrochemical systems are novel bioprocesses which employ exoelectrogenic biofilm on electrode as a biocatalyst for electricity generation and various useful chemical production. Previous reports show that electrogenic biofilms of MFCs are time varying systems and dynamically interactive with the electrically conductive media (carbon paper as terminal electron acceptor). It has been reported that maximum power point tracking (MPPT) method can automatically control load by algorithm so that increase power generation and columbic efficiency. In this study, we developed logic based control strategy for external load resistance by using $LabVIEW^{TM}$ which increases the power production with using flat-plate MFCs and MPPT circuit board. The flat-plate MFCs inoculated with anaerobic digester sludge were stabilized with fixed external resistance from $1000{\Omega}$ to $100{\Omega}$. Automatic load control with MPPT started load from $52{\Omega}$ during 120 hours of operation. MPPT control strategy increased approximately 2.7 times of power production and power density (1.95 mW and $13.02mW/m^3$) compared to the initial values before application of MPPT (0.72 mW and $4.79mW/m^3$).

옥외용 실리콘 고무의 장기 오존열화에 따른 내트랙킹 특성 및 유전특성 변화 (TRACKING AND DIELECTRIC CHARACTERISTICS OF OZONE AGED SILICONE RUBBER USED FOR OUTDOOR INSULATI0N)

  • 이창영;김영호;이상진;박완기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1996년도 하계학술대회 논문집 C
    • /
    • pp.1541-1543
    • /
    • 1996
  • This paper describes the results of characteristics on the tracking resistance, hydrophobicity and dielectric properties of silicone rubbers used for outdoor insulation with ozone ageing. The tracking and ozone ageing tests for this purpose ware made in according to IEC 587 and ASTM D 1149, respectively. Additionally, we investigated the surface structure of the silicone rubbers with FT-IR and SEM. From the test results, it is proven that the higher the degree of ozon ageing, the worse tracking characteristics.

  • PDF

$A\;\ell\;(OH)_3$를 첨가(添加)한 PVC의 내(耐)Tracking성(性)과 열분석(熱分析)에 관한 연구(硏究) (A Study on Thermegravimetry and Tracking Resistance of PVC Doped with $A\;\ell\;(OH)_3$)

  • 강성화;임기조;신용덕;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.389-391
    • /
    • 1995
  • Using as an alternate of insulating material for outdoor and cable, however, it has still many problems to be solved in the field of material such as resistances of environment and tracking. In this paper, Tracking property of PVC filled with aluminum hydroxide have been investigated by ASTM D 2303 method. It was found that time to track of PVC filled aluminum hydroxide was longer than that of unfilled PVC. Tensile strength and elongation of PVC were decreases increased with aluminum hydroxide contents. On the other hand, Thermegravimetry of PVC decreased. Therefore, the increase of time to tracking breakdown by antitracking additive can be explained by increased degradation temperature of polymer.

  • PDF

EPDM 컴파운드의 전기적 특성에 미치는 카본블랙의 영향 (Effects of carbon blacks on the electrical properties of EPDM compounds)

  • 이철호;조용석;전영준;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 D
    • /
    • pp.1593-1595
    • /
    • 1999
  • Effects of carbon black species and concentration on the mechanical and electrical properties of alumina trihydrate filled EPDM compounds were investigated. Mechanical properties improved with increasing carbon black concentration, and these effects were prominent in carbon blacks haying large specific area. In the case of non-conductive carbon black. tracking resistance improved when a small amount of carbon black was added to EPDM. Conductive carbon black showed detrimental effect to dielectric losses, volume resistivity and tracking resistance of EPDM compound.

  • PDF

EPDM/Carbon black 컴파운드의 절연특성 (Dielectric properties of EPDM/Carbon black compounds)

  • 이철호;김상욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 D
    • /
    • pp.1432-1435
    • /
    • 1998
  • Influences of carbon black contents on the tracking resistance, tan $\delta$ and dielectric constant volume resistivity and dielectric strength of EPDM compounds before and after a exposure to UV radiation were investigated. Carbon black content up to 1.5 phr have a positive effect to improve the resistance to tracking and erosion, since carbon black diminish the leakage current. Results from the study reveal that both tan $\delta$ and dielectric constant volume resistivity and dielectric strength are unaffected by adding of carbon black up to 2.0 phr and carbon black have a significant effect to suppress the photo-degradation of EPDM compounds.

  • PDF

EPDM의 전기적 특성에 미치는 수산화알미늄의 영향 (Effects of Alumina Trihydrate on Electrical Performance of EPDM)

  • 이철호;전영준;서광석;노흥석;이미경
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1995년도 추계학술대회 논문집 학회본부
    • /
    • pp.382-385
    • /
    • 1995
  • Electrical properties such as tracking resistance, dielectric constant, $tan\delta$, and volume resistivity, and mechanical properties such as tensile, and strength, and % elongation were measured with the alumina trihydrate filled with EPDM. The results were dicussed in terms of the effect of hydroxyl group. The test results show that the tracking resistance of EPDM improves with the increase in ATH content, whereas volume resistivity, dielectric constant, $tan\delta$ decrease wi th increasing ATH content due to polar nature of ATH. In the charge accumulation characteristics, the homocharge is formed in pure EPDM, and as the ATH content increases in the EPDM compound, the amount of homocharge decrease.

  • PDF