• Title/Summary/Keyword: tower system

Search Result 844, Processing Time 0.036 seconds

Wireless sensor networks for permanent health monitoring of historic buildings

  • Zonta, Daniele;Wu, Huayong;Pozzi, Matteo;Zanon, Paolo;Ceriotti, Matteo;Mottola, Luca;Picco, Gian Pietro;Murphy, Amy L.;Guna, Stefan;Corra, Michele
    • Smart Structures and Systems
    • /
    • v.6 no.5_6
    • /
    • pp.595-618
    • /
    • 2010
  • This paper describes the application of a wireless sensor network to a 31 meter-tall medieval tower located in the city of Trento, Italy. The effort is motivated by preservation of the integrity of a set of frescoes decorating the room on the second floor, representing one of most important International Gothic artworks in Europe. The specific application demanded development of customized hardware and software. The wireless module selected as the core platform allows reliable wireless communication at low cost with a long service life. Sensors include accelerometers, deformation gauges, and thermometers. A multi-hop data collection protocol was applied in the software to improve the system's flexibility and scalability. The system has been operating since September 2008, and in recent months the data loss ratio was estimated as less than 0.01%. The data acquired so far are in agreement with the prediction resulting a priori from the 3-dimensional FEM. Based on these data a Bayesian updating procedure is employed to real-time estimate the probability of abnormal condition states. This first period of operation demonstrated the stability and reliability of the system, and its ability to recognize any possible occurrence of abnormal conditions that could jeopardize the integrity of the frescos.

A Simple Ensemble Prediction System for Wind Power Forecasting - Evaluation by Typhoon Bolaven Case - (풍력예보를 위한 단순 앙상블예측시스템 - 태풍 볼라벤 사례를 통한 평가 -)

  • Kim, Jin-Young;Kim, Hyun-Goo;Kang, Yong-Heack;Yun, Chang-Yeol;Kim, Ji-Young;Lee, Jun-Shin
    • Journal of the Korean Solar Energy Society
    • /
    • v.36 no.1
    • /
    • pp.27-37
    • /
    • 2016
  • A simple but practical Ensemble Prediction System(EPS) for wind power forecasting was developed and evaluated using the measurement of the offshore meteorological tower, HeMOSU-1(Herald of Meteorological and Oceanographic Special Unite-1) installed at the Southwest Offshore in South Korea. The EPS developed by the Korea Institute of Energy Research is based on a simple ensemble mean of two Numerical Weather Prediction(NWP) models, WRF-NMM and WRF-ARW. In addition, the Kalman Filter is applied for real-time quality improvement of wind ensembles. All forecasts with EPS were analyzed in comparison with the HeMOSU-1 measurements at 97 m above sea level during Typhoon Bolaven episode in August 2012. The results indicate that EPS was in the best agreement with the in-situ measurement regarding (peak) wind speed and cut-out speed incidence. The RMSE of wind speed was 1.44 m/s while the incidence time lag of cut-out wind speed was 0 hour, which means that the EPS properly predicted a development and its movement. The duration of cut-out wind speed period by the EPS was also acceptable. This study is anticipated to provide a useful quantitative guide and information for a large-scale offshore wind farm operation in the decision making of wind turbine control especially during a typhoon episode.

『Rivers of Joseon』 Analysis of the Disaster Management System During the Great Flood of the Eulchuk Year (조선시대와 현대의 재난관리계층 비교분석 : 『조선의 하천』 을축년 대홍수와 괴산댐 월류를 중심으로)

  • Kwon, Seol A;Na, Jong Il;Byun, Sung-Soo
    • The Journal of the Korea Contents Association
    • /
    • v.19 no.1
    • /
    • pp.472-483
    • /
    • 2019
  • Why can't we be free from diverse crises threatening our lives in a high-tech future society? Disasters interrupt habitual and institutionalized patterns of behavior and bring about a kind of social shock to make people follow social and individual changes. An interesting fact revealed in the study finding is that the role of disaster management control tower was proper during the Great Flood ofthe Eulchuk Year(1925) and the unified disaster management system facilitated smooth cooperation with relevant authorities. Also, motivating disaster management organizations positively influenced organizational commitment. This implies that if we constantly ask to improve current institutions by introspecting and learning, based on historical records, we may be able to find insights for a safe society of the future.

Quantitative Analysis for Win/Loss Prediction of 'League of Legends' Utilizing the Deep Neural Network System through Big Data

  • No, Si-Jae;Moon, Yoo-Jin;Hwang, Young-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.26 no.4
    • /
    • pp.213-221
    • /
    • 2021
  • In this paper, we suggest the Deep Neural Network Model System for predicting results of the match of 'League of Legends (LOL).' The model utilized approximately 26,000 matches of the LOL game and Keras of Tensorflow. It performed an accuracy of 93.75% without overfitting disadvantage in predicting the '2020 League of Legends Worlds Championship' utilizing the real data in the middle of the game. It employed functions of Sigmoid, Relu and Logcosh, for better performance. The experiments found that the four variables largely affected the accuracy of predicting the match --- 'Dragon Gap', 'Level Gap', 'Blue Rift Heralds', and 'Tower Kills Gap,' and ordinary users can also use the model to help develop game strategies by focusing on four elements. Furthermore, the model can be applied to predicting the match of E-sports professional leagues around the world and to the useful training indicators for professional teams, contributing to vitalization of E-sports.

Measures for Improving Response of Autonomous Police Against Mass Disasters (자치경찰의 대형재난 대응 개선방안)

  • Jae-Min Lee;Jae-Hun Shin
    • Journal of the Society of Disaster Information
    • /
    • v.19 no.3
    • /
    • pp.481-489
    • /
    • 2023
  • Purpose: The purpose of this study is to examine the actual disaster response and suggest improvement measures for introduction of an autonomous police system Method: This study suggests the improvement measures by reviewing police disaster response manual, related statistical data, and statutes comprehensively Result: The introduction of autonomous police system enabled effective management of police based on circumstances of each region. However, there are still doubts on police response against situations that require large number of personnel. According to analysis on roles of autonomous police during the mass disasters, the autonomous police controlled disaster site to prevent secondary damage, prevented additional disaster damages, and rescued people. However, it is hard for the autonomous police to respond against the mass disasters due to its structure. Conclusion: To improve the response of autonomous police against mass disasters, this study suggested on disaster scene control and secondary damage prevention by the police, cooperative disaster response with regional autonomous police, and utilization of control tower.

A Comparative Study on Degradation of BTEX Vapor by O3/UV, TiO2/UV, and O3/TiO2/UV System with Operating Conditions (운전조건에 따른 O3/UV, TiO2/UV 및 O3/TiO2/UV 시스템의 BTEX 증기처리에 관한 비교 연구)

  • Kim, Kyoung-Jin;Park, Ok-Hyun
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.24 no.1
    • /
    • pp.91-99
    • /
    • 2008
  • A multilayer tower-type photoreactor, in which $TiO_2$-coated glass-tubes were installed, was used to measure the vapor-phase BTEX removal efficiencies by ozone oxidation ($O_3$/UV), photocatalytic oxidation ($TiO_2$/UV) and the combination of ozone and photocatalytic oxidation ($O_3/TiO_2$/UV) process, respectively. The experiments were conducted under various relative humidities, temperatures, ozone concentrations, gas flow rates and BTEX concentrations. As a result, the BTEX removal efficiency and the oxidation rate by $O_3/TiO_2$/UV system were highest, compared to $O_3$/UV and $TiO_2$/UV system. The $O_3/TiO_2$/UV system accelerated the low oxidation rate of low-concentration organic compounds and removed organic compounds to a large extent in a fixed volume of reactor in a short time. Therefore, $O_3/TiO_2$/UV system as a superimposed oxidation technology was developed to efficiently and economically treat refractory VOCs. Also, this study demonstrated feasibility of a technology to scale up a photoreactor from lab-scale to pilot-scale, which uses (i) a separated light-source chamber and a light distribution system, (ii) catalyst fixing to glass-tube media, and (iii) unit connection in series and/or parallel. The experimental results from $O_3/TiO_2$/UV system showed that (i) the highest BTEX removal efficiencies were obtained under relative humidity ranging from 50 to 55% and temperature ranging from 40 to $50^{\circ}C$, and (ii) the removal efficiencies linearly increased with ozone dosage and decreased with gas flow rate. When applying Langmuir-Hinshelwood model to $TiO_2$/UV and $O_3/TiO_2$/UV system, reaction rate constant for $O_3/TiO_2$/UV system was larger than that for $TiO_2$/UV system, however, it was found that adsorption constant for $O_3/TiO_2$/UV system was smaller than that for $TiO_2$/UV system due to competitive adsorption between organics and ozone.

Korea's Free Economic Zone as an Economic Development Strategy and Operational System (경제발전전략으로서 한국의 경제자유구역과 운영체계에 관한 연구)

  • Koh, Eui-Hyeon
    • Journal of Distribution Science
    • /
    • v.12 no.9
    • /
    • pp.113-123
    • /
    • 2014
  • Purpose - After Korea's Free Economic Zone (FEZ) system was launched in 2003, there have been many debates about upgrading it and its support systems. However, as of 2013, there were insufficient results. Further, upon the designation of the East Coast and Chungbuk as official FEZs from February 4, 2013 by the 56th the Commission, there is a concern that many people are in the area designated as FEZ 8. This study investigates Korea's new FEZ system as part of Korea's primary new economic development policy in the 21st century. Therefore, this study examines views on the weaknesses of the past ten years of FEZs so that Korea can expand its FEZ system. Research design, data, and methodology -Many countries have considered the FEZ as an economic special zone. By reviewing previous research models, this study provides an update using recent data and materials, until 2013, from the Center of Free Economic Zones. In previous studies, the lack of support systems was attributed to proposals to ensure operational autonomy and differentiation of each FEZ; however, the main cause cannot be solved through regulatory issues, as difficulties caused by the operational system are responsible for the problems. We wish to analyze the FEZ, specifically the operational system; this is the main issue of this study. Results - After the first FEZs were established, it became necessary to have basic plans, as investment results in 2013 compared to the same period this year led to lower earnings in the first half of 2014. We propose an improvement of the operational system because in the free economic zones, the operational system is the root cause of the underlying problem. The results of this research are as follows. The weak management of the FEZ system is influenced by weak investment, delayed development, foreigners' living facilities, benefits of foreign investments, the control tower's policy making decision process, quickness of the process of satisfying legal requirements, and support For the independence of FEZs. Conclusion - Local governments do not have legal rights over FEZ deregulation and investment industries. This study suggests that the local government should have more independence from the central government. Moreover, independent management committees are more effective for ensuring public rights, better employee responsibilities, and better-qualified personnel. The FEZ committee struggles to effectively manage the locations of FEZs, foreign investments, and related facilities under the control of the Ministry of Trade, Industry and Energy. Thus, the FEZ committee should be under either the Prime Minister's office or the Presidential committee, to control and effectively coordinate between the local and central governments. If the problem clearly applies to the operational system in 2013, it is necessary to provide materials and methods so that the results of the first half of 2014 can be computed despite the data limits and lack of resources, and the data can be analyzed in a more diachronic thesis.

A Study on the Treatment Performance of Coalescer to Treat Exhaust Gas Cleaning Water (콜레이서를 이용한 배기가스 세정수 처리 성능에 관한 연구)

  • Ha, Shin-Young;Kim, In-Soo
    • Journal of Navigation and Port Research
    • /
    • v.40 no.1
    • /
    • pp.1-6
    • /
    • 2016
  • This study was conducted on a circulation system which can recycle waste water from EGCS(Exhaust Gas Cleaning System) using a wet scrubber that is used to treat air pollutants from ships. Though we developed a water treatment system that could remove effectively particulate matters and dispersed oil included in cleaning water for Ship Exhaust Gas Recycle System(DePM & DeSOx), we found that it is difficult to treat minutely dispersed oil only by means of centrifugal-typed purifier. Therefore, to this system, we applied a coalescer that coalesces emulsified minute oil particles in the 2nd phase of dispersion state after being filtered through the centrifugal-typed purifier. After we treated cleaning water drained out of Ship Exhaust Gas Recycle System(DePM & DeSOx) by using both purifier and coalescer, we found that particulate matters and dispersed oil were removed more than 55% and 99%, respectively, in comparison with those contained in cleaning water influent. Putting the results together, we conclude that the treated cleaning water can be recycled as normal cleaning water if this cleaning water treatment system is employed by the wet cleaning tower system for the reduction of air pollutants from ships.

An Analysis of the Operational Productivity and Cost for the Utilization of Forest-biomass(I) - the Operational time and Productivity - (산림바이오매스 이용을 위한 산림작업 공정 및 비용 분석(I) -작업시간 및 공정 -)

  • Mun, Ho-Seong;Cho, Koo-Hyun;Park, Sang-Jun
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.4
    • /
    • pp.583-592
    • /
    • 2014
  • This study was carried out to investigate the operational time and productivity of logging operation by chain saw, yarder attached on tractor, tower-yarder, mini-truck, mini-forwarder, and chipping operations by mini-chipper, large-chipper in order to develop the efficient logging operation system for utilization of forest-biomass. As a result, the average felling and bucking time using chain saw at the site 1 and 2 was observed to be 182.7 sec/cycle and 518.5 sec/cycle respectively. The average yarding time was 202.5 sec/cycle using yarder attached on tractor and 295.1 sec/cycle using tower-yarder. The average forwarding time was 2,073 sec/cycle using mini-truck and 2,248.4 sec/cycle using mini-forwarder. The operational time of felling and bucking using chain-saw can be delayed according to the direction of fallen trees. The selection of felling direction is very important to yarding operation because the direction between width-yarding and felling are interrelated. Productivity can be improved through educating and training operators in the yarding operations. Mini-forwarder is needed to use because of higher productivity and lower cost than mini-truck. The operational productivity of felling and bucking by chain saw was $66.96m^3/man{\cdot}day$ and $43.86m^3/man{\cdot}day$ at site 1 and 2 respectively. The yarding productivity was $5.68m^3/man{\cdot}day$ by yarder attached on tractor, $10.74m^3/man{\cdot}day$ by tower-yarder. The forwarding productivity was $21.29m^3/man{\cdot}day$ by mini-truck, $28.57m^3/man{\cdot}day$ by mini-forwarder. The chipping productivity was $4.42m^3/man{\cdot}day$ by mini-chipper, $21.87m^3/man{\cdot}day$ by large-chipper.

Analysis of Characteristics of the Abandoned Tumulus Site Located at the East Side of the Silla Era Hwang Bok Sa (皇福寺) Site (신라 황복사지(皇福寺址) 동편 폐고분지(廢古墳址)의 성격)

  • Jang, Hojin;Kang, Ryangji
    • Korean Journal of Heritage: History & Science
    • /
    • v.53 no.1
    • /
    • pp.88-105
    • /
    • 2020
  • This study examined existing theories of the characteristics of the abandoned tumulus site located at the east side of the Silla era Hwang Bok Sa (皇福寺) site and attempted an archaeological approach based on the derived facts, combining both the results of this study and those of a recently conducted excavation survey. The results of this investigation exhibited the following outcomes. First, the excavation survey revealed that the huge rounded stones discovered on the surface of a rice paddy field located at the east side of the Silla era Hwang Bok Sa were all protecting stones, processed on the front side in the form of a bow, designating a royal tomb. Most of these protecting stones had deviated from their original positions due to subsequent farming practices and some had been re-cycled for construction purposes as fences or foundations for structures built in the Silla era. Considering the prevailing belief in the concept of reincarnation, the bone rank system, and royal authority in the Silla era at that time, it would seem likely that the royal tombs were not intentionally destroyed. Therefore, it is speculated that the stones in this royal tomb were abandoned during construction of the tomb of the King at that time and then naturally re-cycled as building components used in construction sites in later years. Second, this study comparatively analyzed the scale and quality of the supporting stones at the royal tomb site in Guhwang-dong. The analysis results verified that those supporting stones were the same stones from the royal tomb used as supporting stones for statues symbolizing the twelve earthly branch spirits that were restored at the site of the tower at the royal tomb. This confirmed that the statues of the twelve earthly branches spirits sitting at the Hwang Bok Sa site were the protecting stones from a different royal tomb. Accordingly, the conclusion that has been generally accepted to date-that the protecting stones of the statues of twelve earthly branches spirits sitting at Hwang Bok Sa site were probably moved from the royal tomb site in Guhwang-dong-must inevitably be modified. Third, based on the structure of the protecting stones and type of the royal tomb, it is speculated that the individual buried in the royal tomb at Guhwang-dong is one of the kings who followed King Heungdeok and similar times of the buried person of the tomb that was considered as King Gyeongdeok, and who was before the buried person of the tomb that was considered as Kim Yu-sin. In addition, when considering the historical art patterns on the supporting stones of the statues that symbolize the twelve earthly branches spirits, which were moved to the site of the tower at the royal tomb, it is reasonable to believe that the person buried at the royal tomb at Guhwang-dong is likely one of the Kings of the late Silla era of the 9th century.