• 제목/요약/키워드: total harmonic

검색결과 569건 처리시간 0.029초

Vibration Analysis of shadowmask using measured acceleration at stud pin

  • Kim, Dong-Hwan;Kim, Jong-Heon;Oh, Hyung-Seok
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2003년도 International Meeting on Information Display
    • /
    • pp.1151-1152
    • /
    • 2003
  • Harmonic analysis, based on finite element method, is popularly used to predict a response of shadow mask to the external excitation from speakers. Since vibration wave travels from speakers to the shadow mask, a finite element model must include all mechanical parts between the speakers and the shadow mask, which increases total time needed in finite element modeling and computation. In this paper, we perform the harmonic analysis on a MF assembly to obtain frequency response function of a shadow mask, and compare the solutions with experimental results.

  • PDF

THD의 복소 성분을 이용한 고조파 왜곡 환경에서의 전력 계산 (Computation of Distortion Power Using Complex THD)

  • 최종욱;장길수
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권7호
    • /
    • pp.389-396
    • /
    • 2004
  • This paper introduces a new algorithm to calculate distortion power using complex THD(Total Harmonic Distortion) index. The proposed algorithm involves FFT(Fast Fourier Transform) to compute real and imaginary THDs of voltage and current. Case studies are presented to show the availability of the proposed method.

배전선로에서의 비선형부하에 따른 중성선 고조파 분석 (Analysis of Neutral Harmonic Currents according to Non-linear Loads in Distribution Lines)

  • 왕태희;김현수;이상봉;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.183-184
    • /
    • 2008
  • In this paper, the THD(Total Harmonic Distortion) in distribution systems according to the ratio of non-linear loads was calculated and analyzed. The PCC(Point of Common Coupling) is selected to analyze THD of a 3-phase current and a neutral current.

  • PDF

전류형 능동 교류 전력 필터의 해석 (Analysis of Current-Fed Active AC Power Filters)

  • Choe, Gyu-Ha
    • 대한전기학회논문지
    • /
    • 제38권6호
    • /
    • pp.441-450
    • /
    • 1989
  • A control technique for current-fed filters is proposed which not only eliminates the harmonic current, but also controls the reactive power at the ac sides of PWM inverter-induction motor drive system. Injecting the proposed PWM current enables the harmonic components of orders not greater than the number of pulses per half-cycle to be removed completely. Also it enables the input fundamental power factor to become unity and hence total input power factor can be improved greatly. Digital simulation is performed to investigate the theoretical output characteristics of the current-fed filters by the proposed control technique.

  • PDF

옵셋 전압을 이용한 일정 스위칭 주파수의 Random PWM 기법 (A novel Random PWM technique with a constant switching frequency utilizing an offset voltage)

  • 김도겸;김상훈
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2016년도 추계학술대회 논문집
    • /
    • pp.212-213
    • /
    • 2016
  • 본 논문에서는 옵셋 전압을 이용한 Random PWM 기법을 제안한다. 제안된 Random PWM은 일정 스위칭 주파수 하에서 유효벡터를 랜덤하게 위치시켜 고조파 스펙트럼(Spectrum)을 확산한다. 제안된 기법과 일반적인 PWM 기법의 고조파 스펙트럼 분포, Harmonic Spread Factor(HSF), Total Harmonic Distortion(THD)를 통해 제안된 Random PWM의 유효성을 확인하였다. 3.7kW 유도 전동기에 대한 실험을 통해 제안된 기법의 타당성을 검증하였다.

  • PDF

계통연계형 인버터의 왜곡된 계통전압에 의해 발생하는 전류고조파 저감방법 (Reduction Method of Harmonic Current by Distorted Grid Voltage in the Grid-connected Inverter)

  • 목형수;최규하;이정민;김상훈;지준근
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2007년도 추계학술대회 논문집
    • /
    • pp.108-111
    • /
    • 2007
  • Phase angle in grid-connected inverter is important information for current control. When different loads are connected to PCC(Point of Common Coupling) of grid, distorted grid voltage is taken place by load utility generating distorted current. Especially, in case the grid voltage is distorted by low order frequency such as $3^{rd}$, $5^{th}$ harmonic, phase angle of PLL output is distorted. This paper analyze problem of current THD(Total Harmonic Distortion) due to distorted phase angle by distorted grid voltage, and propose control method compensating this problem. Also, it‘s validity is verified by simulation and experiment.

  • PDF

Variable Structure PWM Controller for Highly Efficient PV Inverters

  • Oh, Seong-Jin;SunWoo, Myoung-Ho
    • Journal of Power Electronics
    • /
    • 제9권6호
    • /
    • pp.866-873
    • /
    • 2009
  • In general, the output voltage level of a PV array varies widely at various irradiances and temperatures. The MPP (Maximum Power Point) range of a medium- or high-power PV PCS is normally 450~830Vdc or 300~600Vdc. This means the PV PCS should operate in a wide range of modulation indexes. The PV PCS should satisfy the harmonic current requirement that the TDD (Total demand distortion) shall not exceed 5%. This paper proposes a new PWM control method for a medium- or high-power PV PCS which increases the efficiency of power conversion in all operation ranges with acceptable harmonic ripple currents. This paper compares and analyzes appropriate PWM schemes for the PV PCS in the view points of conversion efficiency and current harmonics.

비선형 부하의 고조파로 인한 배전계통의 영향 분석 (Analysis of Harmonic Effects due to Non-linear Load in Distribution Systems)

  • 이호림;김현수;여상민;김철환
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2009년도 제40회 하계학술대회
    • /
    • pp.2225_2226
    • /
    • 2009
  • An increasing of non-linear loads such as power electronic equipment in distribution systems is the reason for the greater concern about harmonics in recent time. A harmonic current and voltage in distribution systems can cause many problems such as malfunction of protective equipment. In this paper, Total Harmonic Distortion(THD) of voltage according to magnitudes and measurement locations of the non-linear loads was calculated and analyzed with Electro-Magnetic Transients Program(EMTP).

  • PDF

Real time Implementation of SHE PWM in Single Phase Matrix Converter using Linearization Method

  • Karuvelam, P. Subha;Rajaram, M.
    • Journal of Electrical Engineering and Technology
    • /
    • 제10권4호
    • /
    • pp.1682-1691
    • /
    • 2015
  • In this paper, a real time implementation of selective harmonic elimination pulse width modulation (SHEPWM) using Real Coded Genetic Algorithm (RGA), Particle Swarm Optimization technique (PSO) and a new technique known as Linearization Method (LM) for Single Phase Matrix Converter (SPMC) is designed and discussed. In the proposed technique, the switching frequency is fixed and the optimum switching angles are obtained using simple mathematical calculations. A MATLAB simulation was carried out, and FFT analysis of the simulated output voltage waveform confirms the effectiveness of the proposed method. An experimental setup was also developed, and the switching angles and firing pulses are generated using Field Programmable Gate Array (FPGA) processor. The proposed method proves that it is much applicable in the industrial applications by virtue of its suitability in real time applications.

Markov Chain을 이용한 철도계통의 고조파 분석 (Harmonics Analysis of Railroad Systems using Markov Chain)

  • 송학선;이승혁;김진오;김형철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.230-233
    • /
    • 2005
  • This paper proposes power qualify assessment using Markov Chain applied to Ergodic theorem. The Ergodic theorem introduces the state of aperiodic, recurrent, and non-null. The proposed method using Markov Chain presents very well generated harmonic characteristics according to the traction's operation of electric railway system. In case of infinite iteration, the characteristic of Markov Chain that converges on limiting probability Is able to expected harmonic currents posterior transient state. TDD(Total Demand Distortion) is also analyzed in expected current of each harmonic. The TDD for power quality assesment is calculated using Markov Chain theory in the Inceon international airport IAT power system.

  • PDF