• Title/Summary/Keyword: total dust

Search Result 510, Processing Time 0.029 seconds

Characteristics of Allergic Patients in Soonchunhyang University Cheonan Hospital (순천향대학교 천안병원에 내원한 알레르기 환자의 특성)

  • Park, Jae-Suk;Lee, Tae-Young;Choi, Seoung-Hey;Kim, Hwi-Jun;Choi, Young-Jin
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.39 no.2
    • /
    • pp.104-112
    • /
    • 2007
  • The purpose of this study was to evaluate the general features of allergic patients in northwestern Chungcheongnamdo who visited Soonchunhyang University Cheonan Hospital. The subjects in this study were 1692 suspected allergic patients. After their allergic symptoms were checked and a MAST-CLA test was conducted, the following results were obtained: 1. The mean age of the subjects was 23.1 years old. The male patients represented 56.2% and the female patients accounted for 43.8%. 1387 (82.0%) patients of those investigated suffered from allergic disease. 2. Among the 1387 patients, 1022 (73.7%) patients showed an increased total IgE level. The positive rate of those who were in their 40s (87.0%) was the highest, but their age made no difference to their positive rate of total IgE. 3. Concerning the positive rate for allergen specific antibody by age, those who were in their teens (73.5%) topped the list and similar in all age group except in their 40s. By gender, the positive rate of the male and female were 56.3% and 43.9% respectively. Regarding the positive rates by allergic disease, those who suffered from allergic rhinitis (60.4%) were most vulnerable, followed by the patients with allergic dermatitis (47.4%), with bronchial asthma (47.2%) and with urticaria (39.4%). 4. As for seasonal positive rates, they were most susceptible in April (77.2%) and May (71.1%). We discovered a significant difference according to seasons; Spring (60.1%), Winter (45.4%) and Summer (39.2%). 5. In case of Korean inhalent panel, the most dominant allergen-specific antibodies were "Cockroach mix" (31.1%), followed by "D. pteronyssius" (23.8%) and "Dog" (14.3%). In the event of food panel, the most popular allergen-specific antibodies were "D. farinae" (25.0%), followed by "D. pteronyssinus" (19.8%) and "Hose dust" (12.0%). 6. The residential type made no difference to the positive rates of "House dust", "Cockroach mix" and "Dog" as major antigen but compared with others, positive rates for "Tick" were somewhat higher in apartment buildings.

  • PDF

A Study on Exposure to Hazard Factors in Furnace Worker in Ferro-Alloy Manufacturer Factory (합금철 제조공장 출탕 노동자의 유해인자 노출)

  • Cha, Wonseok;Kim, Boowook;Choi, Byungsoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.4
    • /
    • pp.302-312
    • /
    • 2017
  • Objectives: In this study, an evaluation of the working environment of furnace workers was performed and the work-relatedness of the occupational diseases were examined Methods: In this study, two electric furnaces at a single casting business site producing manganese-based iron alloy were selected, and occupational exposures to hazardous substances were evaluated for furnace workers and furnace worker assistants. Results: As a result, total dust concentration were $0.407{\sim}3.001mg/m^3$ and respirable dust concentration were $0.196{\sim}0.584mg/m^3$. The highest concentration of crystalline silica was $0.079mg/m^3$ In the case of Masato and Sosuckwhoi crystalline silica, they contained 90.85% and 4.17% respectively. Manganese concentration was the highest at a $0.205mg/m^3$ maximum. The average of black carbon is $11.56{\mu}g/m^3$ and the maximum concentration is $604.23{\mu}g/m^3$. PAHs concentration was the highest at a $78.301{\mu}g/m^3$ of naphthalene. The concentration of carbon monoxide was 18.82 ppm(total average 3.89 ppm) during pouring, and the maximum is 131 ppm. The formaldehyde concentration was 0.003 to 0.007 ppm. Conclusions: It seems that conditions in the past were worse, since casting has recently been performed only twice per day for about 20 minutes, reducing the amount of pouring, and local exhaust systems have been installed one-by-one. In addition, it was judged that the past exposure levels were higher considering the points measured on the back-side due to the risk of damage to the individual samples. It was found that operators could be exposed to high concentrations of crystalline silica, and that they were also exposed to high concentrations of metal(fume) and carbon monoxide during pouring. Therefore, there is a risk that occupational diseases such as lung cancer and COPD may occur with long-term work in such a process.

Microbial Exposure Assessment in Sawmill, Livestock Feed Industry, and Metal Working Fluids Handling Industry

  • Park, Hyun-Hee;Park, Hae-Dong;Lee, In-Seop
    • Safety and Health at Work
    • /
    • v.1 no.2
    • /
    • pp.183-191
    • /
    • 2010
  • Objectives: The objective of this study is to investigate the distribution patterns and exposure concentrations of bioaerosols in industries suspected to have high levels of bioaerosol exposure. Methods: We selected 11 plants including 3 livestock feed plants (LF industry), 3 metal working fluids handling plants (MWFs industry), and 5 sawmills and measured total airborne bacteria, fungi, endotoxins, as well as dust. Airborne bacteria and fungi were measured with one stage impactor, six stage cascade impactor, and gelatin filters. Endotoxins were measured with polycarbonate filters. Results: The geometric means (GM) of the airborne concentrations of bacteria, fungi, and endotoxins were 1,864, $2,252\;CFU/m^3$, and $31.5\;EU/m^3$, respectively at the sawmills, followed by the LF industry (535, $585\;CFU/m^3$, and $22.0\;EU/m^3$) and MWFs industry (258, $331\;CFU/m^3$, and $8.7\;EU/m^3$). These concentrations by industry type were significantly statistically different (p < 0.01). The ratio of indoor to outdoor concentration was 6.2, 1.9, 3.2, and 3.2 for bacteria, fungi, endotoxins, and dust in the LF industry, 5.0, 0.9, 2.3, and 12.5 in the MWFs industry, and 3.7, 4.1, 3.3, and 9.7 in sawmills. The respiratory fractions of bioaerosols were differentiated by bioaerosol types and industry types: the respiratory fraction of bacteria in the LF industry, MWF industry, and sawmills was 59.4%, 72.0%, and 57.7%, respectively, and that of fungi was 77.3%, 89.5%, and 83.7% in the same order. Conclusion: We found that bioaerosol concentration was the highest in sawmills, followed by LF industry facilities and MWFs industry facilities. The indoor/outdoor ratio of microorganisms was larger than 1 and respiratory fraction of microorganisms was more than 50% of the total microorganism concentrations which might penetrate respiratory tract easily. All these findings suggest that bioaerosol in the surveyed industries should be controlled to prevent worker respiratory diseases.

Outflow properties of DIGIT embedded sources

  • Kang, Seonmi;Lee, Jeong-Eun;Choi, Minho;Evans II, Neal J.;Dunham, Michael M.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.40 no.1
    • /
    • pp.80.1-80.1
    • /
    • 2015
  • We present a study of outflows on 24 embedded young stellar objects selected from the source list of the Dust, Ice, and Gas in Time (DIGIT) Herschel key program. To study the relation between the CO outflows observed in low-J transitions and the properties of protostars more consistently with a homogeneous data set, we mapped the CO outflows of the selected targets in the J = 1-0 and J = 2-1 lines with two Korean telescopes (SRAO and TRAO). We compare CO outflow force ($F_{CO}$) with the bolometric luminosity, ($L_{bol}$) bolometric temperature, and the FIR molecular line luminosities of CO, $H_2O$, OH, and [O I] detected by the Herschel-PACS observations. We find that $F_{CO}$ of J = 1-0 is greater than that of 2-1 by a factor of ~ 2. The well known correlation between $F_{CO\;2-1}$ and $L_{bol}$ is not very evident in our sample as a whole, but they show a rather strong correlation when IRAM 04191+1522 is excluded. IRAM 04191+1522 has relatively high $F_{CO\;2-1}$ in spite of its low $L_{bol}$. This object is a well-known VeLLO, which is believed in the quiescent phase of the episodic mass accretion in the embedded stage. $L_{bol}$ traces a current accretion, but $F_{CO\;2-1}$ traces accretion happened long ago. Therefore, the low-$L_{bol}$ with the high-$F_{CO\;2-1}$ can be explained by the episodic accretion. $F_{CO\;2-1}$ shows little correlation with individual FIR line luminosities of CO, $H_2O$, OH, while [O I] and total FIR line luminosity seem to have correlations with $F_{CO\;2-1}$. This result is interpreted as the accretion energy deposits on species differently depending on shock properties, but the total FIR line luminosity sums the total accretion energy dispersed to different species.

  • PDF

Study on PM10, PM2.5 Reduction Effects and Measurement Method of Vegetation Bio-Filters System in Multi-Use Facility (다중이용시설 내 식생바이오필터 시스템의 PM10, PM2.5 저감효과 및 측정방법에 대한 연구)

  • Kim, Tae-Han;Choi, Boo-Hun
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.48 no.5
    • /
    • pp.80-88
    • /
    • 2020
  • With the issuance of one-week fine dust emergency reduction measures in March 2019, the public's anxiety about fine dust is increasingly growing. In order to assess the application of air purifying plant-based bio-filters to public facilities, this study presented a method for measuring pollutant reduction effects by creating an indoor environment for continuous discharge of particle pollutants and conducted basic studies to verify whether indoor air quality has improved through the system. In this study conducted in a lecture room in spring, the background concentration was created by using mosquito repellent incense as a pollutant one hour before monitoring. Then, according to the schedule, the fine dust reduction capacity was monitored by irrigating for two hours and venting air for one hour. PM10, PM2.5, and temperature & humidity sensors were installed two meters front of the bio-filters, and velocity probes were installed at the center of the three air vents to conduct time-series monitoring. The average face velocity of three air vents set up in the bio-filter was 0.38±0.16 m/s. Total air-conditioning air volume was calculated at 776.89±320.16㎥/h by applying an air vent area of 0.29m×0.65m after deducing damper area. With the system in operation, average temperature and average relative humidity were maintained at 21.5-22.3℃, and 63.79-73.6%, respectively, which indicates that it satisfies temperature and humidity range of various conditions of preceding studies. When the effects of raising relatively humidity rapidly by operating system's air-conditioning function are used efficiently, it would be possible to reduce indoor fine dust and maintain appropriate relative humidity seasonally. Concentration of fine dust increased the same in all cycles before operating the bio-filter system. After operating the system, in cycle 1 blast section (C-1, β=-3.83, β=-2.45), particulate matters (PM10) were lowered by up to 28.8% or 560.3㎍/㎥ and fine particulate matters (PM2.5) were reduced by up to 28.0% or 350.0㎍/㎥. Then, the concentration of find dust (PM10, PM2.5) was reduced by up to 32.6% or 647.0㎍/㎥ and 32.4% or 401.3㎍/㎥ respectively through reduction in cycle 2 blast section (C-2, β=-5.50, β=-3.30) and up to 30.8% or 732.7㎍/㎥ and 31.0% or 459.3㎍/㎥ respectively through reduction in cycle 3 blast section (C-3, β=5.48, β=-3.51). By referring to standards and regulations related to the installation of vegetation bio-filters in public facilities, this study provided plans on how to set up objective performance evaluation environment. By doing so, it was possible to create monitoring infrastructure more objective than a regular lecture room environment and secure relatively reliable data.

The State of Marine Pollution in the Waters adjacent to Shipyards in Korea - 1. Analysis of Pollution Incidents occurred in Shipyards (국내 조선소 주변해역의 해양오염 현황 - 1. 조선소 오염사고 분석)

  • Kim, Kwang-Soo;Han, Won-Hui
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.20 no.6
    • /
    • pp.646-652
    • /
    • 2014
  • Data of pollution incidents which occurred in shipyards of South Korea for 10 years from 2004 to 2013 were collected and analyzed in order to propose the plans for the prevention of pollution incidents in shipyards. Total number of pollution incidents in shipyards was 103 cases over the nation of Korea for the recent 10 years and the average annual number was about 10 cases, and annual cases tended to increase from 8 cases in 2004 to 23 cases in 2010 and then to decrease to 9 cases in 2013. The location data of pollution incidents showed 32 cases in Busan metropolitan city (31%), 30 cases in Jeonnam (29%), 21 cases in Gyeongam (21%), 5 cases in Jeju (5%), 4 cases in Gangwon (4%), 4 cases in Gyeongbuk (4%), 3 cases in Chungnam (3%) and 3 cases in Incheon metropolitan city (3%). According to the data of work types of shipyards, 60 cases happened during the work of ship repair (58%), 25 cases during the work of ship breakup (24%), 10 cases in the course of ship building (10%) and 8 cases by others (8%). The data of pollutant type showed oil and oily mixtures to be 59 cases (57%), waste paint dust to be 22 cases (21%), iron dust and welding slag to be 13 cases (13%), wastes to be 4 cases (4%), waste FRP powder to be 3 cases (3%), and others to be 2 cases (2%). The plans for the prevention of pollution incidents in shipyards of Korea were proposed as follows; (1) Observance of the related laws and regulations, (2) Establishment and implementation of action plans to prevent areas dense with shipyards from causing pollution incidents, (3) Establishment and implementation of oil pollution prevention plans in shipyards, especially during the ship repair and breakup works, (4) Preparation of measures to solve civil complaints against pollution incidents in shipyards, and (5) Improvement in national management for the control of shipyards.

Monitoring of Working Environment Exposed to Particulate Matter in Greenhouse for Cultivating Flower and Fruit (과수 및 화훼 시설하우스 내 작업자의 미세먼지 노출현황 모니터링)

  • Seo, Hyo-Jae;Kim, Hyo-Cher;Seo, Il-Hwan
    • Journal of Bio-Environment Control
    • /
    • v.31 no.2
    • /
    • pp.79-89
    • /
    • 2022
  • With the wide use of greenhouses, the working hours have been increasing inside the greenhouse for workers. In the closed ventilated greenhouse, the internal environment has less affected to external weather during making a suitable temperature for crop growth. Greenhouse workers are exposed to organic dust including soil dust, pollen, pesticide residues, microorganisms during tillage process, soil grading, fertilizing, and harvesting operations. Therefore, the health status and working environment exposed to workers should be considered inside the greenhouse. It is necessary to secure basic data on particulate matter (PM) concentrations in order to set up dust reduction and health safety plans. To understand the PM concentration of working environment in greenhouse, the PM concnentrations were monitored in the cut-rose and Hallabong greenhouses in terms of PM size, working type, and working period. Compare to no-work (move) period, a significant increase in PM concentration was found during tillage operation in Hallabong greenhouse by 4.94 times on TSP (total suspended particle), 2.71 times on PM-10 (particle size of 10 ㎛ or larger), and 1.53 times on PM-2.5, respectively. During pruning operation in cut-rose greenhouse, TSP concentration was 7.4 times higher and PM-10 concentration was 3.2 times higher than during no-work period. As a result of analysis of PM contribution ratio by particle sizes, it was shown that PM-10 constitute the largest percentage. There was a significant difference in the PM concentration between work and no-work periods, and the concentration of PM during work was significant higher (p < 0.001). It was found that workers were generally exposed to a high level of dust concentration from 2.5 ㎛ to 35.15 ㎛ during tillage operation.

Protective effect of Codium fragile extract on fine dust (PM2.5)-induced toxicity in nasal cavity, lung, and brain cells (미세먼지(PM2.5)로 유도된 세포(비강, 폐, 뇌)독성에 대한 청각(Codium fragile)의 보호효과)

  • Kim, Gil Han;Park, Seon Kyeong;Kang, Jin Yong;Kim, Jong Min;Shin, Eun Jin;Moon, Jong Hyeon;Kim, Min Ji;Lee, Hyo Lim;Jeong, Hye Rin;Heo, Ho Jin
    • Korean Journal of Food Science and Technology
    • /
    • v.53 no.2
    • /
    • pp.223-229
    • /
    • 2021
  • To evaluate the protective effect of Codium fragile on fine dust (PM2.5)-induced cytotoxicity, we investigated its antioxidant activity and cell protective effect on PM2.5-exposed cells. The 40% ethanolic extract of C. fragile showed the highest total phenolic content, whereas the water extract of C. fragile showed the highest total polysaccharide content. The protective effect of the extracts on PM2.5-induced oxidative damage in nasal cavity (RPMI2650), lung (A549), brain (MC-IXC), hippocampus (HT-22), and microglia (BV-2) cells was evaluated by measuring the intracellular reactive oxygen species (ROS) content and cell viability. The results showed that the 40% ethanolic extract more efficiently inhibited ROS production than the water extract. In contrast, PM2.5-exposed cells treated with the water extract showed higher viability than those treated with the 40% ethanolic extract.

Strengthening Efficiency for the Various Corner Shapes of RC Member confined with Continuous Fiber Sheets (연속섬유 시트로 보강된 RC 부재의 모서리 형상에 따른 보강 효율에 관한 연구)

  • Ko, Hune-Bum;Lee, Jin-Seop
    • Journal of the Korea Institute of Building Construction
    • /
    • v.8 no.2
    • /
    • pp.113-119
    • /
    • 2008
  • Recently, fiber reinforced polymers(FRP) composite materials are used extensively in the rehabilitation of concrete structural members. A main application is to wrap beams and columns using the continuous fibers sheets to improve their strength and ductility. The corner chamfering affects significantly the performance of the continuous fibers sheets, and could lead to environmental problem with waste and dust. The main purpose of this paper is to verify the effect of corner conditions on the strength of the continuous fiber sheets, and to introduce new attached components which can avoid environmental problem. A total of 15 specimens were tested and carefully checked for three types of continuous fiber sheets(carbon, glass, and aramid) and three types of corner conditions(non-chamfering, chamfering, and device attaching). It is proved that the devices proposed in this research have some capabilities to use for RC member. But additional research will be needed for commercializing.

Aerodynamic acoustics of automotive weather strip protuberance (풍절소음 저감을 위한 웨더스트립 돌출부 형상연구)

  • Kim, Tae-Hoo;Lee, Gye-Ho;Jeon, Seung-Gyeong;Hwang, Jung-Ho;Kim, Joon-Hyung
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.2546-2551
    • /
    • 2007
  • Weather Strip(W/S) is a rubber part to proof water, sound and dust for opening and shutting devices including vehicle doors. And it requires high dimension precision and durability to proof water, noise, vibration and etc. But ironically it itself makes some wind noise because of some protuberance with glasses. The air flow analysis of door part of vehicle makes it possible to calculate and find out the cause of wind noise. In previous analysis, we focus on the numerical air flow analysis of the automobile side part. We do 2D-C.F.D first and 3D second. Through simulations, we can calculate the amount of sound pressure level at the glass run and find out the effects of glass run to make wind noise. Finally we can improve shape of glass run to reduce wind noise although it is small amounts of sound pressure reduction compared with total vehicle noise level.

  • PDF