• Title/Summary/Keyword: topping

Search Result 142, Processing Time 0.031 seconds

Shear Performance Evaluation of the Joint between Hollow Core Slabs (Hollow core 슬래브 간 접합부의 전단저항성능 평가)

  • Hong, Geon-Ho;Baek, Jong-Sam;Park, Hong-Gun
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.14 no.4
    • /
    • pp.94-101
    • /
    • 2010
  • Recently, the interest of precast concrete is increased for rapid construction in construction fields. Experimental study about the shear performance of the joint between hollow core slabs which have internal core to reduce their weight was performed. Main test variables were thickness of the topping concrete and existence of the wiremesh. Total 8 specimens including 4 in-plane shear and 4 out of plane shear were tested. Test results were analyzed in terms of cracking load, failure load, failure aspect, stiffness and ductility, and compared its design load to develop optimum design details. Test results indicated that the shear performance of the non-shrinkage mortar specimen was similar to that of 30mm thickness topping concrete specimen, and the effect of wiremesh reinforcement did not affect the failure load or stiffness of the specimens but the increase of ductility. And this paper presents the comparison results of the test results and design load to provide the optimum detail of the joint design between the hollow core slabs.

Interface Shear Strength in Half Precast Concrete Slab (반두께 P.C. 슬래브의 면내전단내력에 관한 연구)

  • 이광수;김대근;최종수;신성우
    • Magazine of the Korea Concrete Institute
    • /
    • v.6 no.4
    • /
    • pp.161-168
    • /
    • 1994
  • Half-P.C. slab system is the composite structural system which utilizes precast concrete for lower portion and cast in situ concrete for upper portion slab. When the composite slab using Half P.C. slab is deformed by flexural moment, horizontal shear happened at the interface between Half P.C. slab and topping concrete. To resist horizontal shear strength a scratch method has tried. To determine ultimate interface shear strength, shear stress, and shear coefficient, high and normal strength concrete are used for topping concrete. Major variables are compressive strength of topping concrete with or without shear reinforcement, quantitative roughness of the P.C. :surface and tie or untie of the stud with welded deformed wire fabric in the P.C. member. The Icross sectional area on joints is 3,200 $cm^2$ in all specimens. Test results showed that shear stress increased, as the depth of the quantitative roughness increased. The horizontal shear strength could be resisted with safe by the quantitative roughness without shear tie. A shear coefficient determinant equation is proposed such that K = 0.025918 + 0.0068894$\cdot$R – 0.000182354${\cdot}R^2$

Establishment of Arch Training Method in Summer Season Cultivation of Cucumber under Rain-shelter in Highlands (고랭지 오이의 아치식 유인재배법 확립)

  • Lee, Jong-Nam;Lee, Eung-Ho;Kim, Won-Bae;Ryu, Seung-Yeol;Yong, Yeong-Rok
    • Journal of Bio-Environment Control
    • /
    • v.13 no.1
    • /
    • pp.26-32
    • /
    • 2004
  • Growth and yield of cucumber (Cucumis sativus L.) with arch training method were evaluated on several training heights, planting densities, and topping node orders. Cucumber cultivar 'Eunsung-baekdadagi' was planted on 9 June with three training heights of 1.5, 1.8, and 2.1 m, there planting densities of 90${\times}$40, 90${\times}$50, and 90${\times}$60 cm, and five topping node orders of 20th, 30th, 35th, and nontopping. The plot of 2.1 m training height resulted in the higher sun-scald fruit rates due to the higher temperature above 37$^{\circ}C$ in the upper space of plastic house. The plot of 1.8 m arch training height showed higher fruit setting and marketable yield rate compared to the other training heights. The maketable yield rate with 1.8 m height arch training was 102,691 kg ${\cdot}$ $ha^{-1}$, 21% higher value than that of 1.5 m. Powdery mildew incidence increased with the increase of planting density. Lower LAI were shown depending on the higher topping node order. Lower light transmission ratio was shown in the higher planting density plots, might be due to the crowded stems and leaves inside those plots. Fruit setting rate was also higher in main stems rather than in lateral ones. Marketable yie이 in 90${\times}$50 cm planting distance with 35th node topping treatment was 98,311 kg ${\cdot}$ $ha^{-1}$, 5% higher than that 90${\times}$40 cm planting distance with 30th node topping treatment. Thus the 1.8 m of training height, 90${\times}$50 cm of planting distance, and 35th node topping was evaluated for the effective cultivation condition in arch training of cucumber in highland.

Comparative Efficacy for Dressing Methods of Iodine on Infected Full Thickness Skin Wound in the Mouse (흰 쥐의 감염된 전층피부 결손에서 Iodine의 드레싱 방법에 따른 창상치유 효과의 비교)

  • Lee, Jong-Hoon;Kim, Yo-Han;Min, Kyung-Hee;Hong, Sung-Hee;Lee, Won-Mi;Chae, Jeong-Don;Jun, Jin-Hyun
    • Archives of Plastic Surgery
    • /
    • v.37 no.3
    • /
    • pp.213-219
    • /
    • 2010
  • Purpose: Iodine has been used for the prevention or management of wound infection as a topical agent. Although iodine was widely used mainly by Betadine$^{(R)}$ and cadexomer iodine, there was no comparative study on the efficacies of dressing methods of iodine. And also it's wound healing effect was not yet clear. The purpose of this study is to compare antibacterial effects and wound healing effects associated with various dressing methods of iodine on infected full thickness skin defect in the mouse. Methods: One full thickness skin defects in the mice (n=60) were developed on the back and left open for twenty-four hours. Sixty mice were divided into four groups : group S (dressing with Betadine$^{(R)}$ soaking, n=15), group T (dressing with Betadine$^{(R)}$ topping, n=15), group I (dressing with Iodosorb$^{(R)}$, n=15), group G (control group, dressing with dry gauze, n=15). The size of the wound defects and the grades of wound healing were evaluated in 4, 7, 10 days, and antibacterial effect was evaluated with restricted zone in Mueller Hinton agar by disk diffusion method. Results: After the wound was left open for twenty-four hours, many Staphylococcus aureus were cultured. The wound defect size was decreased in order of Betadine$^{(R)}$ soaking, Iodosorb$^{(R)}$, Betadine$^{(R)}$ topping and gauze dressing group in all days, but difference among experimental groups was not statistically significant. The grade score of wound healing was increased in order of Betadine$^{(R)}$ soaking, Iodosorb$^{(R)}$, Betadine$^{(R)}$ topping and gauze dressing group, and the difference was statistically significant. Antibacterial effect for S. aureus was increased in order of Iodosorb$^{(R)}$, Betadine$^{(R)}$ soaking, Betadine$^{(R)}$ topping and gauze dressing group, and the difference was statistically significant. Conclusion: Selection of the effective dressing method of iodine for infected wounds remains a controversial decision. According to this study, Iodosorb$^{(R)}$ may be most effective method for antibacterial effect and Betadine$^{(R)}$ soaking may be most effective method for infected wound healing. However, further study is necessary to evaluate the clinical efficacy of dressing methods of iodine and to search for the mechanisms that explain their effects.

Kalina Cycle : Highly Efficient Bottoming Cycle In Connection With A Combined Power Plant (Kalina 사이클 : 복합 발전용 고효율 하부사이클)

  • 박영무
    • Journal of Energy Engineering
    • /
    • v.2 no.2
    • /
    • pp.154-170
    • /
    • 1993
  • 복합발전사이클은 서로 다른 온도조건에서 운전되는 두 개의 사이클을 열역학적으로 결합한 발전사이클로서 Fig. 1-(d) 처럼 고온부 사이클에서 배출되는 열량을 저온부 사이클에서 회수하여 전체 시스템효율을 개선하도록 설계되었다$^{1)}$ . 고온부에서 작동하는 사이클을 상부사이클(topping cycle or topper)이라고하며 저온부에서 작동하는 사이클을 하부사이클(bottoming cycle or bottomer)이라고 한다.

  • PDF

Solar tower combined cycle plant with thermal storage: energy and exergy analyses

  • Mukhopadhyay, Soumitra;Ghosh, Sudip
    • Advances in Energy Research
    • /
    • v.4 no.1
    • /
    • pp.29-45
    • /
    • 2016
  • There has been a growing interest in the recent time for the development of solar power tower plants, which are mainly used for utility scale power generation. Combined heat and power (CHP) is an efficient and clean approach to generate electric power and useful thermal energy from a single heat source. The waste heat from the topping Brayton cycle is utilized in the bottoming HRSG cycle for driving steam turbine and also to produce process steam so that efficiency of the cycle is increased. A thermal storage system is likely to add greater reliability to such plants, providing power even during non-peak sunshine hours. This paper presents a conceptual configuration of a solar power tower combined heat and power plant with a topping air Brayton cycle. A simple downstream Rankine cycle with a heat recovery steam generator (HRSG) and a process heater have been considered for integration with the solar Brayton cycle. The conventional GT combustion chamber is replaced with a solar receiver. The combined cycle has been analyzed using energy as well as exergy methods for a range of pressure ratio across the GT block. From the thermodynamic analysis, it is found that such an integrated system would give a maximum total power (2.37 MW) at a much lower pressure ratio (5) with an overall efficiency exceeding 27%. The solar receiver and heliostats are the main components responsible for exergy destruction. However, exergetic performance of the components is found to improve at higher pressure ratio of the GT block.

Sap Transmission Pattern of CGMMV and Effect of Disinfectant on Watermelon (수박 CGMMV의 즙액전염 양상과 전염 억제제의 효과)

  • Ko, Sug-Ju;Lee, Yong-Hwan;Cha, Kwang-Hong;Lee, Tae-Seon;Park, In-Jin
    • Research in Plant Disease
    • /
    • v.10 no.2
    • /
    • pp.150-153
    • /
    • 2004
  • This study was conducted to investigate the sap transmission pattern of CGMMV and to select the disinfectant of sap transmission on watermelon cultivation. Being investigated CGMMV occurrence change after transplanting two diseased plants among 47 plants on the watermelon house, disease spread rapidly from early growth stage of 4 % to late growth stage of 83 %. When the grafting knife and topping scissor was dipped onto the several disinfectants before grafting or topping, disease suppressed 87-95 % on whole milk, skim milk, tri-sodium phosphate, and sodium hypo-chloride solution. Disinfection effects of 88.2 % and 91.2 % on whole milk and skim milk were showed when the hand dipped on the disinfectants.

Effects of the amount, time and form of nitrogen fertilization on the growth and Alkaloid formation in flue-cured Tobacco. (질소비료의 시비량.추비시기.형태가 담배의 생육및 Alkaloid 생성에 미치는 영향)

  • 이경민;변주섭
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.4 no.1
    • /
    • pp.51-59
    • /
    • 1982
  • This experiment was conducted to investigate the effects of fertilization level, additional dressing time and form of nitrogen on the growth and formation of Alkaloid in flue-cured tobacco. The results are abstracted as follows. Length and width of harvested leaves, area of a leaf, leaf area per plant, number of harvested leaves, weight of a leaf, and leaf weight of a plant were larger in the $NO_3$-N plot than $NH_4$-N plot. Length, width and area of the middle leaves increased by additional dressing on 7 days before topping, but the dry weight Per unit leaf area of those was decreased. Leaf shape was broaden in additional dressing plots in comparison with 100% of basal dressing plot, but there is no difference among the additional dressing plots. And the smallest leaf shape index was shown at upper leaves in 100% of basal dressing Plot. Leaf weight of a Plaint was the highest in 12kg/10a Plot among $NO_3$-N form and in 12kg/10a plot among $NH_4$-N form. Total Alkaloid content was higher in $NH_4$-N plot between fertilization forms, and highest in 15kg/10a plot among fertilization levels and at the position of middle and upper leaves in the plot of 7 days before topping among additional dressing times.

  • PDF

Concrete Specification and Mixing Design for the Reduction of Slab Defects in Underground Parking Lot (지하주차장 슬래브 하자 저감을 위한 콘크리트 규격 및 배합설계)

  • Kim, Han-Sic;Ha, Jung-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.05a
    • /
    • pp.235-236
    • /
    • 2023
  • Concrete surfaces have weak surface strength due to bleeding and laitance, and problems such as peeling, cracking, and cracking may occur. In particular, underground parking lots can be said to be more vulnerable to peeling, breaking, and cracking if excessive loading of materials and equipment movement are not managed at the initial age after placing of concrete. Cracks, peeling, and cracking problems in slab concrete in underground parking lots of apartments can lead to leakage problems and affect finishing materials constructed on top of topping concrete, reducing the performance required for waterproof materials. Therefore, in this study, the bleeding and surface strength according to the standard of topping concrete and the use of admixture were reviewed to solve the crack, peeling, and cracking problems among the types of defects in underground parking lot slab concrete. As a result, it was derived that the optimal concrete compressive strength is 30MPa or more, and it is a reasonable performance design method to prohibit the substitution of admixtures.

  • PDF