• Title/Summary/Keyword: top-down joint

Search Result 36, Processing Time 0.022 seconds

The Experimental Study on Deflation of Air for Top-Down Joint area (역타기둥 이음부의 공기포 배출을 위한 실험적 연구)

  • 임형일;이동하;백민수;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.05a
    • /
    • pp.763-768
    • /
    • 2001
  • The purpose of this study is to research a specific material characteristics of top down concrete at column joint and to reduce column joint opening. Based on the established top down study, the experiment to apply an real construction case is performed. When the concrete placed into joint of top down column, raised air bubble is left as opening. This study is examined the incomplete packing reason in the top down column and found to air deflation method. The result of study is below (1) As the method to minimize column opening caused from confined air, it is required that an air exhaust port installation in joint column. (2) From air exhaust port installation, most of air bubble in column part is exhausted. As the concrete placing height is going up, air bubble size is going smaller.

  • PDF

A Study on Void Examination in Top-Down Column Joint (역타설기둥 타설이음 부분의 공극성상에 관한 연구)

  • 이영도;임형일;김성식;정병훈;정상진;진영헌
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2001.11a
    • /
    • pp.34-39
    • /
    • 2001
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down, through V-metering for top down column and concrete experiment.

  • PDF

A Study on Void Characteristics with V-meter in Top-Down Column Joint Part. (초음파를 이용한 역타기둥 이음부의 공극특성에 관한 연구)

  • 이영도;정상진
    • Journal of the Korea Institute of Building Construction
    • /
    • v.1 no.2
    • /
    • pp.191-195
    • /
    • 2001
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down , through V-metering for top down column and concrete experiment. To minimize the void of reverse placement joint, It is more effect to use the sheath method then direct method in concrete placement.

  • PDF

A Study on Strength and Packing Characteristics of Top-Down Joint in Field Experiment (현장실험을 통한 역타설 이음부의 강도 및 충전특성에 관한 연구)

  • 강동현;김종구;김병천;박병근;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1101-1106
    • /
    • 2000
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is to find a solution of removing void and air, way to exhaust air in top down column. through specimen concrete placing experiment.

Non-destructive Inspection of Top Down construction Joints of Column in SRC Structure using Radar and Thermography Method (적외선법과 레이더법에 의한 콘크리트 역타시공 이음부위의 충진상태 평가시험)

  • 박석균;임영수;차은용;김명모
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.799-804
    • /
    • 2000
  • The joint treatment of concrete is one of the technical problems in top down construction method. Joints created wit the top down construction result in serous weakness from the aspects of both structural and water-barrier function. Several case studies for the insepction of top down construction joints of column in SRC structure using radar and infrared thermography method. The advantages and limitations of these methods for non-destructive inspection in top own construction joints are investigated.

  • PDF

Implementation of the joint capability integration and development environment using CASE tool (전산지원 시스템 엔지니어링 도구를 이용한 합동능력 통합 및 개발 환경 구축 사례)

  • Kim, Jin Ill;Park, Jong Seon
    • Journal of the Korean Society of Systems Engineering
    • /
    • v.9 no.2
    • /
    • pp.69-82
    • /
    • 2013
  • US DoD operated JCIDS(Joint Capability Integration and Development System) for top down requirement generation. Although the JCIDS can be a good practice for the countries which are trying to shift from bottom up to top down requirement generation, it contains many processes related with review and approval. In this study we structured a joint capability integration and development process from the JCIDS eliminating the organization dependent review or approval process so that it can be applied to any organization with some modification. Furthermore we implemented the process in the computer aided systems engineering tool, Cradle, for convenient use of the process. The result of this study can provide a basic process for top down capability development, and an efficient why of doing each element of the process using CASE tool.

Non-destructive Inspection of Top-Down Construction Joints of Column in SRC Structure using Ultrasonic Method (초음파법을 이용한 콘크리트 역타시공 이음부 공극의 화상검출특성)

  • Park, Seok-Kyun;Baek, Un-Chan;Lee, Han-Bum;Kim, Myoung-Mo
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.20 no.4
    • /
    • pp.290-295
    • /
    • 2000
  • The joint treatment of concrete is one of the technical problems in top down construction method. Joints created with the top down construction result in serious weakness from the aspects of both structural and water-barrier function. Ultrasonic method was used for the inspection of top down construction joints of a various column in SRC structure in this study. The advantages and limitations of this method for non-destructive inspection in top down construction joints are investigated. As a result, it has been verified that the semi-direct measurement method is more effective than the other methods for detecting the voids of construction joints using ultrasonic method.

  • PDF

Non-destructive Inspection of Top Down Construction Joints of Column in SRC Structure using Ultrasonic Method (초음파법을 이용한 콘크리트 역타시공 이음부위의 비파괴검사)

  • 박석균;백운찬;이한범;김명모
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.04a
    • /
    • pp.811-816
    • /
    • 2000
  • The joint treatment of concrete is one of the technical problems in top down construction method. Joints created with the top down construction result in serious weakness from the aspects of both structural and water-barrier function. Ultrasonic method was used for the inspection of top down construction joints of column in SRC structure in this study. As a result it has been verified that the semi-direct measurement method is more effective than the other methods for detecting the voids of construction joints.

  • PDF

An experimental study on the tensile performance of joints depending on joint type (접합부 형태에 따른 접합부 인장성능에 관한 실험적 연구)

  • Seo, Hyun-Jae;Park, Jong-sun;Choi, Eun-kyu;Song, Jae-Young;Oh, Sang-Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2019.05a
    • /
    • pp.190-191
    • /
    • 2019
  • In complex waterproofing method, the stability of the joint is an important factor. The joints should not be broken for repeated movements and tensile forces. Therefore, we tried to confirm the stability of joints in newly developed joints and general joints. Repeated fatigue resistance performance tests and joint tensile strength tests were carried out on four types of joints. The fatigue resistance performance test showed no abnormality in all four types. It was confirmed that the newly developed top-down joint has higher stiffness than existing joints.

  • PDF

A Study on Void Check as Placing Method with Use of V-meter Method (초음파탐사를 통한 타설방법이 공극에 미치는 영향에 관한 연구)

  • 임형일;최창기;정근호;김우재;이영도;정상진
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2000.10b
    • /
    • pp.1107-1112
    • /
    • 2000
  • When top down method is used, it could be a construction method trouble in column joint, between the former concrete and the latter. It could bring a void and weak concrete in column. The purpose of this study is finding a way to prevent concrete void and concrete suitable for top down, through V-metering for top down column and concrete experiment.