• Title/Summary/Keyword: tooth

Search Result 5,783, Processing Time 0.036 seconds

Modeling of Transmission Error of A Gear Pair with Modified Teeth (치형수정된 기어쌍의 치합전달오차 모델링)

  • 주상훈;노오현;정동현;배명호;박노길
    • Journal of KSNVE
    • /
    • v.8 no.5
    • /
    • pp.841-848
    • /
    • 1998
  • In the gear manufacturing, tooth modification is usually applied for the prevention of tooth impact during the loading. In contrary, tooth profile error causes amplifying the whine noise which is cumbersome to reduce in the automobile gear box. So optimum quantity of the modifications must be obtained for the good performance in the vibrational sense. In this paper, a formulation to define the tooth curve by considering the profile manufacturing error and loading deformation of the gear tooth is suggested and the transmission error and loading deformation of the gear tooth is suggested and the transmission error with modified tooth in the gear system is evaluated. A pair of gear set is mathematically modelled. The equivalent excitation in the gear vibratonal model is formulated. For the experimental evaluaton on the derived transmission error function, a simple geared system is set up in which the gears are designed to give pre-designed tooth profile modification and manufactured by CNC Wire Cutting Machine. Under slow speed operaton, the transmission error of the gear pair is measured by using two rotational laser vibrometers, compared with the calculated one of which the result shows good agreement.

  • PDF

Tooth modification of helical gears for minimization of vibration and noise

  • Chong, Tae-Hyong;Myong, Jae-Hyong;Kim, Ki-Tae
    • International Journal of Precision Engineering and Manufacturing
    • /
    • v.2 no.4
    • /
    • pp.5-11
    • /
    • 2001
  • Vibration and noise of gears is doc to the transmission error and the vibration exciting force caused by the periodically alternating tooth stiffness. Transmission error is the rotation delay between driving and driven gear caused by manufacturing error, alignment error in assembly and so on. Tooth stiffness changes with the proceeding mesh of teeth. The purpose of this study is to develop how to calculate simultaneously the optimum amounts of tooth profile modification. end relief and crowning by minimizing the vibration exciting force of helical gears. We estimate the vibration exciting force by the meshing analysis of gears. Formulated constraints of this problem consist of contact ratio and strengths of gear teeth such as tooth bending strength, surface durability, and scoring. ADS(Automated Design Synthesis) is used as an optimization tool. We also investigate the relation between the aspect ratio and the optimum values of tooth modification. The proposed method can calculate the optimum amount of tooth modification automatically and is expected to be practically useful to resolve the problem of vibration of helical gears.

  • PDF

Familial Tooth Bone Graft: Case Reports (가족치아를 이용한 골이식술: 증례보고)

  • Lee, Ji-Young;Kim, Young-Kyun;Um, In-Woong;Choi, Joon-Ho
    • The Journal of the Korean dental association
    • /
    • v.51 no.8
    • /
    • pp.459-467
    • /
    • 2013
  • The use of autogenous tooth bone graft material has been commercialized since 2008. Autogenous tooth bone grafts always require that the tooth of the patient be extracted, and thus, the use of graft material are limited in many cases. For solution of limitation in quantity and concurrent use of autogenous tooth bone graft material, the grafting of familial teeth has been suggested. It has the following advantages: the teeth of family members are used as bone graft materials, the genetic composition is identical, and potential genetic and infectious risks can be minimized. Because the teeth of family members are used, a good tissue affinity is obtained, and thus, superior bone generation rates compared to those observed for allogenic or xenogenic bones can be anticipated. We used familial tooth bone-graft materials for alveolar ridge augmentation, socket preservation, and maxillary sinus graft in some cases. In most cases, the impacted third molars of their children were prepared as bone graft material and were used for surgery. In one case, the impacted third molar from the patient's brother was used as bone graft material. We obtained satisfactory result and these cases are reported herein.

Mechanical characteristics of involute-circular arc composite tooth profile (인벌류우트-圓弧 合成齒形의 諸特性)

  • 변준형;최상훈;윤갑영
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.10 no.6
    • /
    • pp.870-875
    • /
    • 1986
  • In this study, full-rounded tip curve of rack and its mating fillet curve of pinion in Involute-circular arc composite tooth profile are derived. Mechanical characteristics are calculated analytically, i.e., Specific sliding, Nominal bending stress at working root circle and the Contact factor of the arc of contact in circular arc part to the arc of double contact. These characteristics compared with standard involute tooth profile are improved in circular arc part of composite tooth profile. To obtain more efficient composite tooth profile, we studied these characteristics with regard to the changes of unwound angle and radius of circualr arc. And a design method of composite tooth profile is suggested. Composite tooth profile are compared with standard involute tooth profile.

Determination of the Tooth Modification Amounts for Minimizing the Vibration of Helical Gear (헬리컬 치차의 진동최소화를 위한 치면 수정량의 결정)

  • Chong, Tae-Hyong;Myong, Jae-Hyong;Kim, Ki-Tae
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.17 no.11
    • /
    • pp.199-205
    • /
    • 2000
  • The vibration and noise of gears is due to the vibration exciting force caused by the tooth stiffness which changes periodically as the mesh of teeth proceeds and by the transmission error, that is, the rotation delay between driving gear and driven gear caused by manufacturing error and alignment error in assembly and so on. The purpose of this study is to develop how to calculate simultaneously the optimum amounts of tooth profile modification, end relief and crowning by minimizing the vibration exciting force of helical gears. We estimate the vibration exciting force by the mesh analysis of gears. The constraints of this problem consist of contact ratio and strengths of gear teeth such as tooth fillet stress, surface durability and scoring. ADS(Automated Design Synthesis) is used as an optimization tool. And, since the aspect ratio is an important parameter of tooth modification, we investigate the relation between it and the optimum values of tooth modification. The proposed method can calculate the optimum amount of tooth modification automatically and is to be utilized to resolve the problem of vibration of helical gears.

  • PDF

Analysis of Tooth Profile Accuracy of Enveloping Worm Thread Depending on End Mill Tool Shape (장구형 웜 나사의 절삭 엔드밀 공구 형상에 따른 치형 정밀도 분석)

  • Kang, S.J.;Kim, Y.H.
    • Transactions of Materials Processing
    • /
    • v.28 no.4
    • /
    • pp.183-189
    • /
    • 2019
  • Cylindrical worm reducers are generally used in various fields and forms throughout the industry, and demand is increasing due to their role as an integral part of the industry. Market trends require high-load, high-precision components, and small-sized reducers with large loads. When using a cylindrical worm reducer, a reducer designed with a reduced center distance while maintaining the same output torque results in gear wear. To overcome this difficulty, an enveloping worm gear reducer is introduced and studied. In this paper, three types of end mill tools are used to evaluate the tooth profile accuracy for each tool shape during machining of the tooth profile for a non-developed surface worm thread. The effect of the endmill shape on the accuracy of the tooth profile was analyzed by performing 3D modeling of the surrounding worm tooth profile based on the Hindley method. In this study, we analyzed tooth profile accuracy, tooth surface roughness, and tooth surface machining time, etc. Through the study, efficient machining conditions for the enveloping worm gears and the influence of parameters on the process were presented.

A Study on the Physical Properties and Cytotoxicity of Tooth Ash and Dental Procelain (치아회분(齒牙灰粉)과 도재복합(陶材複合) 매식체(埋植體)의 물리적(物理的) 성질(性質) 및 세포배양(細胞培養)에 의(依)한 조직친화성(組織親和性)에 관(關)한 연구(硏究))

  • Hoh, Ki-Young
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.22 no.1
    • /
    • pp.51-68
    • /
    • 1984
  • The purpose of this study is primarily to test the use value of tooth ash as an alternative material of the synthetic hydroxyapatite. For this purpose the author performed the experimental study to investigate the phsyical properties of sintered tooth ash and its histocompatibility in vitro. The tooth ash was made by incinerating procedure at $650^{\circ}C,\;750^{\circ}C,\;850^{\circ}C,\;950^{\circ}C\;and\;1050^{\circ}C$ respectively. The composition of tooth ash was analyzed and X-ray diffraction was done. The experimental specimens were molded to the cylinderical form 1 cm high, 1 cm in diameter under the pressure of $1000kg/cm^2$, which were divided into two groups; the one is sintered tooth ash at $1100^{\circ}C$ and the other is fired mixture of tooth ash and dental porcelain mixed to the weight ratio of 4:6, 5:5, 6:4 and 7:3. The physical propoerties of the sintered specimens were examined and their microstructure was observed under the Scanning Electron Microscope. The results obtained were as followings: 1. The difference of the tooth ash composition depending on incinerating temperature was of no significance, but the $CO_2$ disappeared from $950^{\circ}C$. 2. X-ray diffraction showed the tooth ash was mainly composed of hydroxyapatite and a small amount of - white lockite. But phase transformation was not disclosed. 3. The microstructure of the sintered specimens of the ashed tooth powder was of no difference in the structure and grain size accompanying the ashed temperature, but sintering ability seemed to be the best in the specimen incinerated at $950^{\circ}C$. 4. There was good wettability in the mixed sintered specimens of the ashed tooth powder and the porcelain powder. 5. The compressive strength of the sintered specimens of the tooth ash incinerated at $950^{\circ}C$ was the highest with $589.75kg/cm^2$ and the porosity and the absorption were the lowest as well. 6. The mixed sintered specimens of the tooth ash and porcelain powder was good in the physical properties in the case of mixed weight ratio of 6:4. 7. The animal fibroblast cultures with porcelain showed increase in the cell number, whereas the tooth ash showed a small degree of growth inhibition. But the difference of cell multiplication efficiency between control cultures and test cultures with tooth ash was not observed.

  • PDF

Relationship between tooth loss and carotid intima-media thickness in Korean adults

  • Chin, Ui-Jung;Ji, Suk;Lee, Su-Young;Ryu, Jae-Jun;Lee, Jung-Bok;Shin, Chol;Shin, Sang-Wan
    • The Journal of Advanced Prosthodontics
    • /
    • v.2 no.4
    • /
    • pp.122-127
    • /
    • 2010
  • PURPOSE. The aim of this study was to examine the relationship between tooth loss and sub-clinical atherosclerosis in Korean adults. MATERIALS AND METHODS. The subjects were part of a cohort study conducted in Ansan city by the Korea University medical school as part of the Korean Genome project. 749 subjects over than 40 years old were evaluated. After taking panoramic radiography, the amount of tooth loss was calculated. The intima-media thickness (IMT) was assessed by using ultrasonography at the common carotid artery. Traditional cardiovascular risk factors for atherosclerosis were also evaluated. The relationship between tooth loss and the IMT was evaluated using ANOVA with Scheffe's multiple comparison method in univariate analysis. Multiple regression analysis was also performed to determine the significance between the IMT and tooth loss. RESULTS. With age, tooth loss increased, but there was no significant increase in other traditional cardiovascular risk factors. Univariate analysis revealed the IMT to be positively related with the amount of tooth loss. Regression analysis of the IMT in the anterior and posterior tooth loss revealed that only the posterior tooth loss was significantly related with the IMT at all sites of the common carotid artery (right far wall, P = .015; left far wall, P = .008; right near wall, P < .001; left near wall, P = .001). CONCLUSION. This study verified the positive relationship between the increased tooth loss at the posterior area and the accumulation of atheroma in arteries.

Oral hygiene form and the subjective health analysis of the elderly (노인의 구강위생행태와 주관적 구강건강 형태에 대한 분석)

  • Kim, Wook-Tae
    • Journal of Technologic Dentistry
    • /
    • v.34 no.2
    • /
    • pp.179-199
    • /
    • 2012
  • Purpose: This study was conducted to prepare the fundamental data on oral hygiene of the elderly and to assess the behavior of oral hygiene, subjective oral health, oral health problem among the elderly, and to contribute to successful enhancement of life in their declining years. Methods: The author surveyed the behavior of oral hygiene, subjective oral health, oral health problem to 192 elderly at a health center of Busan using structured self- administered questionnaire from Nov. 2nd 2009 to Feb. 10th 2010. Collected data were analysed by SPSS WIN 18.0 statistical program for frequency, percentage production, ${\chi}^2$ (Chi-square) verification, t-test, One-way ANOVA, Logistic Regression. Results: The distribution of total subjects by oral health behaviors were 56.8% for "have ever trained how to tooth brushing", 76.6% for "correctly performed tooth brushing by himself ", 71.8% for "tooth brushing a day is two times and less", 87.5% for "it doesn't tooth brushing in meals and after" and 53.6% for "it doesn't use the facility for oral health", respectively. The distribution of total subjects by the state of perceived oral health were 51.0% for "feel the oral discomfort", 51.6% for "feel the comfortable chewing on starchy food", respectively. The mean point of perceived oral health by general characteristics of total subjects were statistically significant difference in sex, type of medical insurance, smoke, exercise, and chronic disease. The mean point of perceived oral health by oral health behaviors of total subjects were statistically significant difference in educational experience on tooth brushing, recognition for tooth brushing by himself, tooth brushing a day, and tongue cleaning. The risk factors of perceived oral health were type of medical insurance and chronic disease in general characteristics, tooth brushing in meals and after and tooth brushing a day, and tongue cleaning in oral health behaviors. Conclusion: The author recommend to the prevention of chronic disease, carry out the tooth brushing in meals and after, three times and over tooth brushing a day and tongue cleaning for oral health. and the author consider that it need to prepare the active countermeasure to oral health such as reeducation for oral health and supply to the tongue cleaner.

IN VIVO STUDY ON ABUTMENT TOOTH MOVEMENT FOR DISTAL EXTENSION REMOVABLE PARTIAL DENTURES (유리단 국소의치의 지대치 운동에 관한 생체학적 연구)

  • Lee, Jong-Yeop;Kim, Kwang-Nam;Chang, Ik-Tae
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.28 no.1
    • /
    • pp.43-61
    • /
    • 1990
  • The laser reflexion method is a new technique which permits precise contactless measurement and observation of tooth mobility as well as tooth movement. The purposes of this study were to clarify the reliability of the laser reflexion method in clinical application and to measure the abutment tooth movement according to clasp design. This study was designed to determine 1) How much a bending movement of the impression plate stand affects the position of the reflexion pattern and how precise the patient bites into plate 2) Which clasp design causes greater movement of the abutment tooth. Under medium and maximum bite forces, tests were performed on central loading position which was 13mm distal to terminal abutment tooth of distal extension removable partial denture. The movement in the mesiodistal and buccolingual directions was measured. The Duncan's New Multiple-Range test was used to compare the means for the four castings under each direction-load combination; and the paired sample t-test was for medium and maximum bite forces. From this experiment, the following results were obtained. 1. The Roach clasp, the combination clasp, the RPI clasp, and the Akers clasp did not significantly differ in their effects on buccolingual movement of the abutment tooth. 2. The direction of abutment tooth movement was not significantly altered by clasp design and all abutment tooth movements were oriented distobuccally. 3. Under medium bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the combination clasp and the RPI clasp. Under maximum bite force, the Akers clasp caused greater distal movement of the abutment tooth than did the RPI clasp. 4. The testing apparatus and procedures used in this study(laser reflexion method) proved to be reliable in clinical application.

  • PDF