• Title/Summary/Keyword: tomography, x-ray

Search Result 810, Processing Time 0.029 seconds

Pulmonary Artery Periadventitial Hematoma in a Patient with Aortic Intramural Hematoma: A Case Report (대동맥벽내 혈종 환자에서의 폐동맥 외막주위 혈종: 증례 보고)

  • Hoon Kwon;Yeon Joo Jeong;Geewon Lee;Minhee Hwang;Jin You Kim;Nam Kyung Lee;Ji Won Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.3
    • /
    • pp.649-653
    • /
    • 2024
  • A pulmonary artery periadventitial hematoma is a rare complication of a Stanford type A intramural hematoma. As the proximal ascending aorta and pulmonary artery share a common adventitial layer, extravasated blood from the intramural hematoma in the ascending thoracic aorta may extend to beneath the adventitia of the pulmonary artery. The authors describe a case involving a 66-year-old male with acute chest pain who presented with a pulmonary artery periadventitial hematoma associated with a Stanford type A intramural hematoma.

Radiologic Manifestations of Pulmonary Nuclear Protein in Testis Midline Carcinoma: A Case Report (폐에 발생한 고환 핵단백질 정중선 암의 영상의학적 소견: 증례 보고)

  • Jung A Kim;Mi-jin Kang;Jung Yeon Kim;Ji-Young Kim;Soung Hee Kim;Myeong Ja Jeong;Ji Hae Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.498-503
    • /
    • 2023
  • Nuclear portein in testis (NUT) midline carcinoma is a very rare and low-differentiating malignant epithelial tumor that differentiates very aggressively and has poor prognosis. NUT midline carcinoma occurring in the lungs in particular can be confused with other cancers because few cases have been reported in Korea to date and can show various histological forms. Reports of radiology findings are very rare worldwide. Here we report the imaging findings of pulmonary NUT midline carcinoma in a 25-year-old female along with pathological findings.

CT/MRI Liver Imaging Reporting and Data System (LI-RADS): Standardization, Evidence, and Future Direction (CT/MRI 간영상 판독과 자료체계: 표준화, 근거 및 발전방향)

  • Yeun-Yoon Kim;Jin-Young Choi
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.1
    • /
    • pp.15-33
    • /
    • 2023
  • The liver imaging reporting and data system (LI-RADS) has been developed with the support of the American College of Radiology to standardize the diagnosis and evaluation of treatment response of hepatocellular carcinoma (HCC). The CT/MRI LI-RADS version 2018 has been incorporated in the American Association for the Study of Liver Diseases guidance. This review examines the effect of CT/MRI LI-RADS on the standardized reporting of liver imaging, and the evidence in diagnosing HCC and evaluating treatment response after locoregional treatment using CT/MRI LI-RADS. The results are compared with other HCC diagnosis guidelines, and future directions are described.

Radiologic Findings of Mesonephric-Like Adenocarcinoma of the Uterine Corpus: A Case Report (자궁 체부에 발생한 중신 유사 선종의 영상 소견: 증례 보고)

  • Ha Jung Kim;Kyeong Ah Kim;Yikyeong Chun;Jeong Woo Kim;Jongmee Lee;Chang Hee Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.3
    • /
    • pp.698-704
    • /
    • 2023
  • According to the 2020 World Health Organization classification, mesonephric-like adenocarcinoma (MLA) is newly categorized as a subtype of endometrial carcinoma and remains a relatively unknown disease owing to its rarity. To the best of our knowledge, radiological findings of MLA have not been reported in the English literature. The uterine MLAs show a worse clinical prognosis and a more aggressive biological behavior than the usual endometrial carcinoma. Herein, we present the imaging findings of a 65-year-old female with a MLA in the uterine corpus. The tumor was a solid endometrial mass with deep myometrial invasion, poor contrast enhancement, and moderate diffusion restriction.

Diabetes disrupts osteometric and trabecular morphometric parameters in the Zucker Diabetic Sprague-Dawley rat femur

  • Robert Ndou;Vaughan Perry;Gcwalisile Frances Dlamini
    • Anatomy and Cell Biology
    • /
    • v.57 no.2
    • /
    • pp.294-304
    • /
    • 2024
  • Type 2 diabetes mellitus is increasingly becoming more prevalent worldwide together with hospital care costs from secondary complications such as bone fractures. Femoral fracture risk is higher in diabetes. Therefore, this study aimed to assess the osteometric and microarchitecture of the femur of Zucker Diabetic Sprague-Dawley (ZDSD) femur. Ten-week-old male rats (n=38) consisting of 16 control Sprague-Dawley (SD) and 22 ZDSD rats were used. The rats were terminated at 20 weeks and others at 28 weeks of age to assess age, diabetes duration effects and its severity. Bilateral femora were taken for osteometry, bone mass measurements and micro-focus X-ray computed tomography scanning to assess the trabecular number (TbN), thickness (TbTh), spaces (TbSp), bone tissue volume to total volume (BV/TV) and volume (BV). Diabetic rats had shorter (except for 20-weeks-old), lighter, narrower, and less robust bones than SD controls that wered more robust. Although cortical area was similar in all diabatic and control rats, medullary canal area was the largest in ZDSD rats. This means that the diabetic rats bones were short, light and hollow. Diabetic rats aged 20 weeks had reduced BV, BV/TV, TbN with more spacing (TbSp). In contrast, the 28 weeks old diabetic rats only showed reduced BV and TbN. Discriminant function analysis revealed, for the first time, that osteometric parameters and TbTh, TbN, and TbSp were affected by diabetes. This knowledge is valuable in the management of diabetic complications.

Robotic-assisted Total Hip Arthroplasty and Spinopelvic Parameters: A Review

  • Steven J. Rice;Anthony D'Abarno;Hue H. Luu
    • Hip & pelvis
    • /
    • v.36 no.2
    • /
    • pp.87-100
    • /
    • 2024
  • Total hip arthroplasty (THA) is an effective treatment for osteoarthritis, and the popularity of the direct anterior approach has increased due to more rapid recovery and increased stability. Instability, commonly caused by component malposition, remains a significant concern. The dynamic relationship between the pelvis and lumbar spine, deemed spinopelvic motion, is considered an important factor in stability. Various parameters are used in evaluating spinopelvic motion. Understanding spinopelvic motion is critical, and executing a precise plan for positioning the implant can be difficult with manual instrumentation. Robotic and/or navigation systems have been developed in the effort to enhance THA outcomes and for implementing spinopelvic parameters. These systems can be classified into three categories: X-ray/fluoroscopy-based, imageless, and computed tomography (CT)-based. Each system has advantages and limitations. When using CT-based systems, preoperative CT scans are used to assist with preoperative planning and intraoperative execution, providing feedback on implant position and restoration of hip biomechanics within a functional safe zone developed according to each patient's specific spinopelvic parameters. Several studies have demonstrated the accuracy and reproducibility of robotic systems with regard to implant positioning and leg length discrepancy. Some studies have reported better radiographic and clinical outcomes with use of robotic-assisted THA. However, clinical outcomes comparable to those for manual THA have also been reported. Robotic systems offer advantages in terms of accuracy, precision, and potentially reduced rates of dislocation. Additional research, including conduct of randomized controlled trials, will be required in order to evaluate the long-term outcomes and cost-effectiveness of robotic-assisted THA.

Efficacy and safety of denosumab treatment for Korean patients with Stage 3b-4 chronic kidney disease and osteoporosis

  • Jin Taek Kim;You Mi Kim;Kyong Yeun Jung;Hoonsung Choi;So Young Lee;Hyo-Jeong Kim
    • The Korean journal of internal medicine
    • /
    • v.39 no.1
    • /
    • pp.148-159
    • /
    • 2024
  • Background/Aims: We evaluated the efficacy and safety of denosumab treatment in severe chronic kidney disease (CKD) patients with osteoporosis. We also investigated whether the treatment affects the coronary artery calcifications. Methods: Twenty-seven postmenopausal women with Stage 3b-4 CKD and osteoporosis were enrolled. Twenty patients received denosumab plus calcium carbonate and vitamin D, and seven controls received calcium carbonate and vitamin D for 1 year. Dual-energy X-ray absorptiometry and coronary artery calcium (CAC) scoring computed tomography were performed before and after treatment. Hypocalcemic symptoms and serum calcium levels were evaluated. Results: After 1 year of treatment, the percent changes of femur neck (3.6 ± 3.2% vs. -0.7 ± 4.4%, p = 0.033) and total hip (3.4 ± 3.8% vs. -1.9 ± 2.1%, p = 0.001) bone mineral density (BMD) were significantly increased in the denosumab treated group compared to the control group. However, the percent change of lumbar spine BMD did not differ between two groups (5.6 ± 5.9% vs. 2.7 ± 3.9%, p = 0.273). The percent change of bone alkaline phosphatase was significantly different in the denosumab-treated group and control group (-31.1 ± 30.0% vs. 0.5 ± 32.0%, p = 0.027). CAC scores did not differ between groups. No hypocalcemic events occurred in both groups. Conclusions: If carefully monitored and supplemented with calcium and vitamin D, denosumab treatment for 1 year provides significant benefits in patients with Stage 3b-4 CKD and osteoporosis. However, denosumab treatment did not affect coronary artery calcifications in these patients.

Effect of build orientation on the accuracy and internal porosity of removable partial denture metal frameworks (적층 빌드 방향이 가철성 국소의치 금속 구조물의 정확도와 내부 다공성에 미치는 영향)

  • Geon Hee Ham;Ji-Hwan Kim
    • Journal of Technologic Dentistry
    • /
    • v.46 no.3
    • /
    • pp.73-83
    • /
    • 2024
  • Purpose: This study aimed to investigate whether the accuracy and internal porosity of removable partial denture frameworks differ depending on the build direction in the selective laser melting method. Methods: A partially edentulous maxillary study model was scanned, and the anterior-posterior palatal bar was then digitally designed. The angles formed between the z-axis and the path of the insertion and removal were divided into five groups: -60°, -30°, 0°, 30°, and 60°. For each group, three removable partial denture metal frameworks were fabricated and used as specimens. The inner surface of each sample was scanned and superimposed on the design file to obtain the root mean square (RMS) value, and the average RMS value of each group was measured. One sample was randomly selected from each group, and the equivalent diameter and sphericity of the pores were analyzed using industrial X-ray three-dimensional computed tomography. To compare statistical differences between groups, the Kruskal-Wallis test of SPSS Statistics ver. 27.0 (IBM) was used (α=0.05). Results: The average RMS values of the whole inner surface accuracy of the specimens were in the order of -60°<0°<-30°<30°<60° (p<0.05). The equivalent diameter and sphericity of internal pores were significantly different among groups (p<0.001). Conclusion: The build orientation of the selective laser melting method influences the accuracy and internal porosity of removable partial denture frameworks.

Feasibility Assessment on the Application of X-ray Computed Tomography on the Characterization of Bentonite under Hydration (벤토나이트 수화반응 특성화를 위한 X선 단층촬영 기술 적용성 평가)

  • Melvin B., Diaz;Gyung Won, Lee;Seohyeon, Yun;Kwang Yeom, Kim;Chang-soo, Lee;Minseop, Kim;Jin-Seop, Kim
    • Tunnel and Underground Space
    • /
    • v.32 no.6
    • /
    • pp.491-501
    • /
    • 2022
  • Bentonite has been proposed as a buffer and backfill material for high-level radioactive waste repository. Under such repository environment conditions, bentonite is subjected to combined thermal, hydrological, mechanical, and chemical processes. This study evaluates the feasibility of applying X-ray CT technology on the characterization of bentonite under hydration conditions using a newly developed testing cell. The cylindrical cell is made of platic material, with a removable cap to place the sample, enabling to apply vertical pressure on the sample and to measure swelling pressure. The hydration test was carried out with a sample made of Gyeonju bentonite, with a dry density of 1.4 g/cm3, and a water content of 20%. The sample had a diameter of 27.5 mm and a height of 34 mm. During the test, water was injected at a constant pressure of 0.207 MPa, and lasted for 7 days. After one day of hydration, bentonite swelled and filled out the space inside the cell. Moreover, CT histograms showed how the hydration process induced an initial increase and later progressive decrease on the density of the sample. Detailed profiles of the mean CT value, CT standard deviation, and CT gradient provided more details on the hydration process of the sample and showed how the bottom and top regions exhibited a decrease on density while the middle region showed an increase, especially during the first two days of hydration. Later, the differences in CT values with respect to the initial state decreased, and were small at the end of testing. The formation and later reduction of cracks was also characterized through CT scanning.

Radiographic differential diagnosis between ameloblastoma and odontogenic keratocyst: with emphasis on CT (법랑모세포종과 치성각화낭의 방사선학적 감별진단 : CT를 중심으로)

  • Soh Byung-Chun;Heo Min-Suk;An Chang-Hyeon;Choi Mi;Lee Sam-Sun;Choi Soon-Chul;Park Tae-Won
    • Imaging Science in Dentistry
    • /
    • v.32 no.3
    • /
    • pp.167-173
    • /
    • 2002
  • Purpose : To evaluate clinical and radiographic differential diagnosis between ameloblastoma and odontogenic keratocyst (OKC) using clinical data, plain radiographs, and CT. Materials and Methods: 25 cases of ameloblastoma and 44 cases of OKC diagnosed in biopsy, were selected from the files stored in Department of Oral and Maxillofacial Radiology, Seoul National University Dental Hospital from 1999 to 2001, and evaluated using following criteria: sex and age, location, shape, border to normal bone tissue, effect to adjacent tissues, homogeneity in the lumen of the lesion, response of the cortical bone, long-to-short length (LIS) ratio of the lesion, and expansion angle of the cortex. Results: Ameloblastoma and OKC were seen most frequently in third decades and no statistical significance was noted between both sexes. Ameloblastoma occurred most frequently in mandibular angle and ramus area (68%) and OKC at the maxillary molar (34.1 %), and mandibular angle and ramus area (43.2%). The root resorption of the adjacent teeth, mandibular canal displacement, and the impaction of teeth were seen more frequently in ameloblastoma than in OKC. The LIS ratio measured in CT was largest in maxillary OKC cases, followed by mandibular ameloblastoma, and mandibular OKC (1.2, 1.8 and 2.4 respectively). The expansion angle of the cortex shows a statistically significant difference between ameloblastoma (48.8°) and OKC (31.5°). Conclusion : The numeric morphology (LIS ratio) and expansion angle of the cortical bone of the lesion measured in computed tomography can be used to differentiate the ameloblastoma and odontogenic keratocyst.

  • PDF