• 제목/요약/키워드: titanium dental implant

검색결과 322건 처리시간 0.03초

Impact of the spatial orientation of the patient's head, metal artifact reduction, and tube current on cone-beam computed tomography artifact expression adjacent to a dental implant: A laboratory study using a simulated surgical guide

  • Matheus Barros-Costa;Julia Ramos Barros-Candido;Matheus Sampaio-Oliveira;Deborah Queiroz Freitas;Alexander Tadeu Sverzut;Matheus L Oliveira
    • Imaging Science in Dentistry
    • /
    • 제54권2호
    • /
    • pp.191-199
    • /
    • 2024
  • Purpose: The aim of this study was to evaluate image artifacts in the vicinity of dental implants in cone-beam computed tomography (CBCT) scans obtained with different spatial orientations, tube current levels, and metal artifact reduction algorithm (MAR) conditions. Materials and Methods: One dental implant and 2 tubes filled with a radiopaque solution were placed in the posterior region of a mandible using a surgical guide to ensure parallel alignment. CBCT scans were acquired with the mandible in 2 spatial orientations in relation to the X-ray projection plane (standard and modified) at 3 tube current levels: 5, 8, and 11 mA. CBCT scans were repeated without the implant and were reconstructed with and without MAR. The mean voxel and noise values of each tube were obtained and compared using multi-way analysis of variance and the Tukey test(α=0.05). Results: Mean voxel values were significantly higher and noise values were significantly lower in the modified orientation than in the standard orientation (P<0.05). MAR activation and tube current levels did not show significant differences in most cases of the modified spatial orientation and in the absence of the dental implant (P>0.05). Conclusion: Modifying the spatial orientation of the head increased brightness and reduced spatial orientation noise in adjacent regions of a dental implant, with no influence from the tube current level and MAR.

타이태늄 합금의 생체적합도에 관한 연구 (Quantitative investigations of titanium alloy implants)

  • 한종현;허성주;구영;최용창;정종평;박중근
    • Journal of Periodontal and Implant Science
    • /
    • 제28권3호
    • /
    • pp.401-408
    • /
    • 1998
  • Screw shaped implants of Titanium-13Zirconium-6Niobium(newly developed), Titanium-6Zirconium-6Sn-6Niobium(newly developed) and Titanium-6Aluminum-4Vanadium were machined with square top and inserted in rabbit bone for 3 months. Biomechanical tests(removal torque) showed Titanium-13Zirconium-6Niobium and Titanium-6Zirconium-6Sn-6Niobium to be more stable in the bone bed than those of Titanium-6Aluminum-4Vanadium. Titanium-13Zirconium-6Niobium implants demonstrated a mean removal torque of 31.59Ncm while Titanium-6Aluminum-4Vanadium demonstrated a mean removal torque of 25.27Ncm and Titanium-6Zirconium-6Sn-6Niobium revealed a mean removal torque of 37.44Ncm and were statistically significance in Wilcoxon Signed Rank test(P<0.05). Histomorphometrical comparisons were performed on $10\;{\mu}m$ thick undecalcified ground sections in the light microscope and Titanium-13Zirconium-6Niobium showed more mean bone-tometal contact ratio than to other twotitanium alloys but had no statistically significant differences were found among the three materials(P>0.01).

  • PDF

Surface characteristics and osteoblastic cell response of alkali-and heat-treated titanium-8tantalum-3niobium alloy

  • Lee, Bo-Ah;Kang, Choong-Hee;Vang, Mong-Sook;Jung, Young-Suk;Piao, Xing Hui;Kim, Ok-Su;Chung, Hyun-Ju;Kim, Young-Joon
    • Journal of Periodontal and Implant Science
    • /
    • 제42권6호
    • /
    • pp.248-255
    • /
    • 2012
  • Purpose: The aim of the present study was to evaluate the biological response of alkali- and heat-treated titanium-8tantalum-3niobium surfaces by cell proliferation and alkaline phosphatase (ALP) activity analysis. Methods: Commercial pure titanium (group cp-Ti) and alkali- and heat-treated titanium-8tantalum-3niobium (group AHT) disks were prepared. The surface properties were evaluated using scanning electron microscopy, energy dispersed spectroscopy and X-ray photoelectron spectroscopy (XPS). The surface roughness was evaluated by atomic force microscopy and a profilometer. The contact angle and surface energy were also analyzed. The biological response of fetal rat calvarial cells on group AHT was assessed by cell proliferation and ALP activity. Results: Group AHT showed a flake-like morphology microprofile and dense structure. XPS analysis of group AHT showed an increased amount of oxygen in the basic hydroxyl residue of titanium hydroxide groups compared with group cp-Ti. The surface roughness (Ra) measured by a profilometer showed no significant difference (P>0.05). Group AHT showed a lower contact angle and higher surface energy than group cp-Ti. Cell proliferation on group AHT surfaces was significantly higher than on group cp-Ti surfaces (P<0.05). In comparison to group cp-Ti, group AHT enhanced ALP activity (P<0.05). Conclusions: These results suggest that group AHT stimulates osteoblast differentiation.

파이버 레이저를 이용한 치과용 임플란트 표면처리에 관한 연구 (A Study on the Surface Treatment of Dental Implant using a Fiber Laser)

  • 신호준;양윤석;황찬연;유영태
    • 한국정밀공학회지
    • /
    • 제28권8호
    • /
    • pp.915-928
    • /
    • 2011
  • Titanium for dental implant application has the superior properties of biocompatibility, specific strength, and corrosion resistance. However, it is extremely difficult to find a suitable surface treatment method for sufficient osseointegration with biological tissue/bone cell and implant surface. Surface treatment technology using laser has been researched as the way to increase surface area of implant. In this study, to develop the surface treatment process with improved adhesion between implant and bone cell at the same time for superior biocompatibility, pulsed laser beam was overlapped continuously for scribed surface morphology and determination of friction coefficient. As the results, surface area and friction coefficient was increased over 2 times by the comparison with sand blasting, which is used for the conventional method. In this time, the optimal condition for laser beam power and beam irradiation speed was 13 watt and 50 mm/sec, respectively.

임플란트 지대주 삭제시의 발생열에 관한 연구 (A Study on the heat generation during implant abutment preparation)

  • 이호진;송광엽;장태엽
    • 구강회복응용과학지
    • /
    • 제19권1호
    • /
    • pp.27-33
    • /
    • 2003
  • Excessive heat generation at the implant-bone interface may cause irreversible bone damage and loss of osseointegration. The effect of heat generation in vitro at the implant surface caused by abutment reduction with high-speed dental turbine was examined. Titanium-alloy abutments connected to a titanium alloy screw-implant embedded in an acrylic-resin block in a $37^{\circ}C$ water bath were prepared. Temperature changes were recorded via embedded thermocouples at the cervix and apex of the implant surface. Analysis of variance for repeated measures was used to compare seven treatment groups. Fifty seconds of continuous cutting with air and water coolant caused a mean temperature increase of $1.24^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $2.50^{\circ}C$ at apex and $1.64^{\circ}C$ at cervix. But, continuous cutting with air coolant caused a mean temperature increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Similar intermittent cutting caused increase of $6.47^{\circ}C$ at apex and $5.77^{\circ}C$ at cervix. Preparation of implant abutment does not lead to detrimental effect on peri-implant tissues provided that adequate cooling. However, without water cooling, extreme overheating could be provoked, reaching the critical temperature that would lead to irreversible bone damage within only a few seconds.

Bone remodeling effects of Korean Red Ginseng extracts for dental implant applications

  • Kang, Myong-Hun;Lee, Sook-Jeong;Lee, Min-Ho
    • Journal of Ginseng Research
    • /
    • 제44권6호
    • /
    • pp.823-832
    • /
    • 2020
  • Background: The formation of a nanotube layer on a titanium nanotube (N-Ti) plate facilitates an active reaction between bone cells and the material surface via efficient delivery of the surface materials of the dental implant into the tissues. Studies have reported that Korean Red Ginseng extracts (KRGEs) are involved in a variety of pharmacological activities: we investigated whether implantation with a KRGE-loaded N-Ti miniimplant affects osteogenesis and osseointegration. Methods: KRGE-loaded nanotubes were constructed by fabrication on pure Ti via anodization, and MC3T3-E1 cells were cultured on the N-Ti. N-Ti implants were subsequently placed on a rat's edentulous mandibular site. New bone formation and bone mineral density were measured to analyze osteogenesis and osseointegration. Results: KRGE-loaded N-Ti significantly increased the proliferation and differentiation of MC3T3-E1 cells compared with cells on pure Ti without any KRGE loading. After 1-4 weeks, the periimplant tissue in the edentulous mandibular of the healed rat showed a remarkable increase in new bone formation and bone mineral density. In addition, high levels of the bone morphogenesis protein-2 and bone morphogenesis protein-7, besides collagen, were expressed in the periimplant tissues. Conclusion: Our findings suggest that KRGE-induced osteogenesis and osseointegration around the miniimplant may facilitate the clinical application of dental implants.

Gene Expression of Osteosarcoma Cells on Various Coated Titanium Materials

  • Sohn, Sung-Hwa;Lee, Jae-Bun;Kim, Ki-Nam;Kim, In-Kyoung;Lee, Seung-Ho;Kim, Hye-Won;Seo, Sang-Hui;Kim, Yu-Ri;Shin, Sang-Wan;Ryu, Jae-Jun;Kim, Meyoung-Kon
    • Molecular & Cellular Toxicology
    • /
    • 제3권1호
    • /
    • pp.36-45
    • /
    • 2007
  • Several features of the implant surface, such as topography, roughness, and composition play a relevant role in implant integration with bone. This study was conducted in order to determine the effects of different-coatings on Ti surfaces on the biological responses of a human osteoblast-like cell line (MG63). MG63 cells were cultured on HA (Hydroxyapatite coating on Titanium), Ano (HA coating on anodized surface Titanium), Zr (zirconium-coating on Titanium), and control (non-coating on Titanium). The morphology of these cells was assessed by SEM. The cDNAs prepared from the total RNAs of the MG63 were hybridized into a human cDNA microarray (1,152 elements). The appearances of the surfaces observed by SEM were different on each of the three dental substrate types. MG63 cells cultured on HA, Ano, Zr, and control exhibited cell-matrix interactions. In the expression of several genes were up-, and down-regulated on the different surfaces. The attachment and expression of key osteogenic regulatory genes were enhanced by the surface morphology of the dental materials used.

상악동 거상술을 동반한 임플란트 식립 후 생존율에 대한 후향적 연구 (The retrospective study of survival rate of implants with maxillary sinus floor elevation)

  • 유정아;이상민;유미경;정의원;김창성;최성호;박필규;조규성
    • Journal of Periodontal and Implant Science
    • /
    • 제39권3호
    • /
    • pp.293-301
    • /
    • 2009
  • Purpose: The purpose of this study is to show the total survival rate of implants with maxillary sinus floor elevation and the effects that reach the survival rate by classifying types of graft materials, implant surface, operation method, bone height. Methods: In a total of 131 patients, 251 implants with sinus floor elevation were installed simultaneously or after regular healing. Various bone grafts (autograft, xonograft, allograft, alloplast) and implant surface (MTX-HA implant, chemical etching implant, Titanium oxide surface implant, resorbable blasting media implant, resorbable blast texturing implant, HA-coated implant) were used. All implants were investigated clinically and radiographically, being with 1 to 5 years follow-up period after installation. Results: The survival rate of 251 implants with maxillary sinus floor elevation was 94%. The types of implant, surface, graft material, bone height have no statistically signi-ficant differencies. Conclusions: It can be suggested that maxillary sinus floor elevation may have predictable result with various bone graft materials and implant surface.

개에서 치아 임플란트 식립후 치조골의 신티그라피 평가 (Scintigraphic Evaluation of Alveolar Bone Following Dental Implantation in Dogs)

  • 김중현;이재영;김명환;이원국;강성수;최석화
    • 대한수의학회지
    • /
    • 제43권2호
    • /
    • pp.289-294
    • /
    • 2003
  • This study aimed to determine of osseointegration following dental implantation in the dog mandible using bone scintigraphy. Five mongrel dogs, weighing approximately 8.5 kg and averaging 1.8 years of age, without active periodontal disease were used. During the entire study period, all dogs were fed a soft commercial diet and water ad libitum to minimize functional loading of the implant. Titanium alloy implant systems 10 mm in length and 4 mm in diameter were chosen for insertion. Twelve weeks prior to implantation, the second and third left mandibular premolars in each dog were extracted for the dental implant insertion. Before the dental implantation procedures and 0, 4, 8, and 12 weeks after the insertions, clinical observation, radiography and bone scintigraphy were conducted. The scintigraphy was obtained using a large field of view gamma camera equipped with a paralled-hole, low-energy collimator about 3 hours after intravenous injection of Tc-99m-MDP (8 mCi/dog) to the dogs. There were not inflammation sign after insertion of dental implants on the mandible in dogs. Implants were slightly movable at the first and fourth weeks, and there was no mobility after 8 weeks. Twelve weeks after dental implantation, the bone uptake scintigraphy of peri-implant bone was similar to that of normal alveolar bone, indicating that peri-implant bone was completely regenerated by new bone. In conclusion, we recommend stable implant fixation with alveolar bone for the accurate and safe repair of teeth loot due to decacy, trauma or peridontal disease. Titanium alloy implants were optimal due to their biocompatibility.

A Preview of the Valid Natural Tooth Implantation(NTI) Related with Periodontal Diseases

  • Chang, Sang-Kohn
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2002년도 추계학술대회
    • /
    • pp.721-721
    • /
    • 2002
  • For about half a century. dental implants made of titanium have developed as a method of restoration for the tooth loss. In these days. the titanium implants seem to be considered as the alternative for the conventional prosthodontics. But its hard to say that the titanium implants are superior to the treatments that preserve the natural tooth. As this is a general opinion among dentists. the implant will not be able to be the alternative for all the prosthetic treatments. Clinically, there are many causes for extracting tooth. The severe destruction of the tooth structure or periodontal diseases leads to inevitable tooth extraction. When the complete cure is doubtful because of narrow intraoral visibility and improper accessibility in approaching to the tooth and periodontal lesion, we. clinicians often inevitably extract tooth. Passive treatments like conventional restoration, curettage or surgical flap cant be the perfect treatments for the tooth that has subgingival root caries or severe periodontal diseases involved furcation. Many clinicians might have been forced to pull out the relatively healthy tooth by the difficulties of approaching to the lesions and poor prognosis. Though the intentional tooth replantation is performed sometimes. as it doesnt have enough scientific foundation. it has not been considered as a popular treatment method yet. I have been felt keenly the necessity of positive tooth preservation, so I have been attempting the treatment that has new concept. calling Natural Tooth Implantation (NTI) clinically. NTI differs from the tooth replantation in the goal for the treatment and biological healing process. Now. I confirm that NT! is a very positive and valid method of tooth preservation. Like you can get from the name. NTI is the dental implant procedure using natural teeth and similar to the healing process of the titanium implants in many aspects. I have been using biocompatible composite resin. DRM. with NTI and got affirmative clinical results from that. So I would like to introduce.roduce.

  • PDF