• Title/Summary/Keyword: titanium dental implant

Search Result 320, Processing Time 0.021 seconds

An Overview of Research Trends in Antibacterial Coatings on Titanium Implants (임상가를 위한 특집 3 - 티타늄 임플란트의 항균코팅 동향)

  • Kim, Woo-Hyun;Kim, Kyoung-Nam
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.113-118
    • /
    • 2010
  • Titanium and titanium alloys are the most common materials used for dental and biomedical implants, owing to their biocompatibility and favourable mechanical properties. However infection of the region surrounding a dental implant by pathogenic microorganisms is a significant factor in implant failure. Prevention and control of microbial colonization of implant surfaces is considerable interest to the biomedical community. One important strategy is to render the implant surface antibacterial by impeding the formation of biofilm. A number of approaches have been proposed for this purpose. Therefore, we reviewed the researches of antibacterial coatings on titanium implants in this articles.

Clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas (심미가 중요시되는 임플란트 치료시 타이타늄 링크-캐드캠 지르코니아 지대주 사용의 임상적 고려)

  • Kim, Jong-Yub
    • The Journal of the Korean dental association
    • /
    • v.54 no.2
    • /
    • pp.123-133
    • /
    • 2016
  • Currently increasing use of implants, especially in anterior implant esthetics has become a major concern for both the patient and dentist. In the case of thin biotype if the thickness of the gingival soft tissue is less than 2mm, human eye can detect differences of colors depends on underlying materials. The zirconia abutment can be use not only for better esthetics but also for the hygienic because it is less attractive for the plaque deposition when it compare to the metals. Zirconia itself has many advantages as a biomaterial but also has frequent mechanical problems when it use for abutment of internal connection implant. For prevention or reduction of mechanical failures, use of titanium-link with zirconia super-structure which part that connects directly into the implant can be a good alternative. In this literature, I would like to review the clinical considerations of use of titanium link - CAD/CAM zirconia abutment for dental implant in esthetically important areas.

  • PDF

Comparison of stress distribution in bone and implant-supported dental prosthesis with zirconia and titanium implants: a 3-dimensional finite element analysis (지르코니아 및 티타늄 임플란트를 사용한 지지골 및 임플란트 유지 수복물의 응력 분포 비교: 3차원 유한 요소 분석)

  • Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.42 no.4
    • /
    • pp.348-354
    • /
    • 2020
  • Purpose: Zirconia is differentiated from other ceramics because of its high resistance to corrosion and wear, excellent flexural strength (900~1400 MPa), and high hardness. Dental zirconia with proven mechanical/biological stability is suitable for the manufacture of implants. However, there are limited in vivo studies evaluating stress distribution in zirconia compared with that in titanium implants and studies analyzing finite elements. This study was conducted to evaluate the stress distribution of the supporting bone surrounding zirconia and titanium implants using the finite element analysis method. Methods: For finite element analysis, a single implant-supported restoration was designed. Using a universal analysis program, eight occlusal points were set in the direction of the occlusal long axis. The occlusal load was simulated at 700 N. Results: The zirconia implant (47.7 MPa) von Mises stress decreased by 5.3% in the upper cortical bone compared with the titanium implant (50.2 MPa) von Mises stress. Similarly, the zirconia implant (20.8 MPa) von Mises stress decreased by almost 4% in the cancellous bone compared with the titanium implant (21.7 MPa) von Mises stress. The principal stress in the cortical and cancellous bone exhibited a similar propensity to von Mises stress. Conclusion: In the supporting bone, the zirconia implant is able to reduce bone resorption caused by mechanically transferred stress. It is believed that the zirconia implant can be a potential substitute for the titanium implant by reinforcing aesthetic characteristics and improving stress distribution.

Chair-side surface treatment method for inducing hydrophilicity in titanium dental implant (치과용 티타늄 임플란트의 골융합 증진을 위한 체어사이드 친수성 표면처리방법)

  • Lee, Jung-Hwan;Jun, Soo-Kyung;Lee, Hae-Hyoung
    • The Journal of the Korean dental association
    • /
    • v.54 no.12
    • /
    • pp.985-995
    • /
    • 2016
  • Titanium (Ti) has been widely used for dental implant due to great biocompatibility and bonding ability against natural alveolar bone. A lot of titanium surface modification has been introduced in dentistry and, among them, methods to introduce micro/nano-roughened surface were considered as clinically approved strategy for accelerating osseointegration of Ti dental implant. To have synergetic effect with topography oriented favors in cell attachment, chair-side surface treatment with reproducibility of micro/nano-topography is introduced as next strategy to further enhance cellular functionalities. Extensive research has been investigated to study the potential of micro/nano-topography preserved chair-side surface treatment for Ti dental implant. This review will discuss ultraviolet, low level of laser therapy and non-thermal atmospheric pressure plasma on Ti dental implant with micro/nano-topography as next generation of surface treatment due to its abilities to induce super-hydrophilicity or biofunctionality without change of topographical cues.

  • PDF

Advanced Surface Modification Techniques for Enhancing Osseointegration of Titanium Implant (임상가를 위한 특집 1 - 티타늄 임플란트의 골융합 증진을 위한 최신 표면처리 기술)

  • Song, Ho-Jun
    • The Journal of the Korean dental association
    • /
    • v.48 no.2
    • /
    • pp.96-105
    • /
    • 2010
  • Titanium implant is used as the most popular dental material for replacement of missing teeth recently. A lot of studies on the surface modification of titanium implant have been carried out for enhancing osseointegration. The surface modification techniques could be classified as follows; topographic modifications which provide roughness and porosity, chemical surface modificationss or deposition of osseoconductive materials, and biochemical modifications to immobilize bone growth factors on titanium surface. In this study, the current and ongoing surface modification techniques and its typical characteristics used in clinics were reviewed. In the future, study and implication about biochemical modifications including patient' s individual characteristics will be important.

Comparative Analysis between Zirconia Implant and Titanium Implant

  • Hwang, Ho-Jeong;Kim, Seong-Kyun;Lee, Joo-Hee;Heo, Seong-Joo;Koak, Jai-Young;Yoo, Soo-Yeon
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.48-53
    • /
    • 2012
  • Various ceramic implant systems made of yttria-stabilized tetragonal zirconia polycystal (Y-TZP) have become commercially available in recent years. A search of the literature was performed to assess the clinical success of dental Y-TZP implants and whether the osseointegration of Y-TZP is comparable to that of titanium, the standard implant material. No controlled clinical studies in humans regarding clinical outcomes or osseointegration could be identified. Clinical data were restricted to case studies and case series. Only 7 animal studies were found. Osseointegration was evaluated at 4 weeks to 24 months after placement in different animal models, sites and under different loading conditions. The mean bone-implant contact percentage was above 60% in almost all experimental groups. In studies that used titanium implants as a control, Y-TZP implants were comparable to or even better than titanium implants. Surface modifications may further improve initial bone healing and resistance to removal torque. Y-TZP implants may have the potential to become an alternative to titanium implants but cannot currently be recommended for routine clinical use, as no long-term clinical data are available.

Influence of zirconia and titanium fixture materials on stress distribution in abutment screws: a three-dimensional finite element analysis (지르코니아 및 티타늄 고정체 소재가 지대주 나사의 응력 분포에 미치는 영향: 3차원 유한 요소 분석)

  • Kim, Eun Young;Hong, Min-Ho
    • Journal of Technologic Dentistry
    • /
    • v.43 no.2
    • /
    • pp.42-47
    • /
    • 2021
  • Purpose: The purpose of this study was to evaluate the stability of abutment screws used with the zirconia fixture-based implant system and compare them with those used with the existing titanium fixture system via the finite element method. Methods: A single implant-supported restoration was designed for the finite element analysis. A universal analysis program was used to set 8 occlusal points along the direction to the long axis of the implant, and an occlusal load of 700 N was applied. Results: In all models (Zir and Ti-fixture model), the screw threads presented with the highest von Mises stress (VMS) values, whereas the head and end presented with the lowest VMS values. The VMS of the screw used in the zirconia-fixture model was 5.97% lower than that used in the titanium-fixture model (261.258 vs. 276.911 MPa, respectively) despite statistical significance. Furthermore, the zirconia fixture (352.912 MPa) had a higher stress value (8.42%) than the titanium fixture (332.331 MPa). In a completely tightened titanium fixture implant system, the stress was concentrated in the implant-abutment connection interface, the zirconia fixture presented with a stable stress distribution. Conclusion: Although the zirconia fixture demonstrated a high VMS value, owing to the stiffness and elasticity coefficients of the material, the stress generated in the abutment screws was similar in all models. In conclusion, the zirconia fixture-based implant system presented with a more stable stress distribution in the abutment screws than the titanium fixture-based implant system.

3D-printed titanium implant with pre-mounted dental implants for mandible reconstruction: a case report

  • Park, Jung-Hyun;Odkhuu, Michidgerel;Cho, Sura;Li, Jingwen;Park, Bo-Young;Kim, Jin-Woo
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.42
    • /
    • pp.28.1-28.4
    • /
    • 2020
  • Background: This clinical case presented a novel method of segmental mandible reconstruction using 3D-printed titanium implant with pre-mounted dental implants that was planned to rehabilitate occlusion. Case presentation: A 53-year-old male who suffered osteoradionecrosis due to the radiation after squamous cell carcinoma resection. The 3D-printed titanium implant with pre-mounted dental implant fixtures was simulated and fabricated with selective laser melting method. The implant was successfully inserted, and the discontinuous mandible defect was rehabilitated without postoperative infection or foreign body reaction during follow-ups, until a year. Conclusions: The 3D-printed titanium implant would be the one of the suitable treatment modalities for mandible reconstruction considering all the aspect of mandibular functions.

Maxillary implant-retained overdenture using CAD/CAM milled titanium bar with Locator® attachment: a case report (CAD/CAM으로 제작된 milled titanium bar와 Locator®를 이용한 상악 임플란트 유지 피개의치: 증례보고)

  • Kim, Min-Jeong;Oh, Sang-Chun;Huh, Yoon-Hyuk
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.30 no.1
    • /
    • pp.64-70
    • /
    • 2014
  • The purpose of this case report is to introduce milled titanium bar with Locator$^{(R)}$ that made by CAD/CAM for implant supported overdenture in maxillary edentulous patients. For over 2 years, in terms of function and esthetics, satisfactory result was obtained.

Implant Supported Overdenture using Milled Titanium Bar with $Locator^{(R)}$ Attachment on Fully Edentulous Maxillae : A Case Report (상악 완전 무치악에서 $Locator^{(R)}$ attachment가 장착된 milled titanium bar를 이용한 임플란트 지지 피개의치: 증례 보고)

  • Oh, Sang-Chun;Han, Ji-Suk;Kim, Min-Jeong
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.2
    • /
    • pp.223-231
    • /
    • 2011
  • The purpose of this case report is to introduce new attachment system(milled titanium bar with $Locator^{(R)}$ attachment) for implant supported overdenture in maxillary edentulous patients. A 56-years-old male patient visited the hospital due to the mobility of his maxillary fixed partial dentures(10-unit bridge). Including temporomandibular joint(TMJ), there was no specific PMHs to influence dental treatment. In radiographic and clinical evaluation, there was a severe bone resorption and mobility in maxillary teeth. Accordingly all the remaining maxillary teeth was extracted and fabrication of implant supported overdenture was planned. The milled titanium bar with $Locator^{(R)}$ was designed as an attachment system, considering the stability and retention of denture, masticatory efficiency, oral hygiene care, esthetics, pronunciation, and patient's financial state. The milled titanium bar was manufactured using CAD/CAM technology, and $Locator^{(R)}$ attachment connected to the bar by tap & drill method. For over 1-year, in terms of function and esthetics, satisfactory result was obtained.