• Title/Summary/Keyword: tip shape

Search Result 572, Processing Time 0.023 seconds

Investigation of Micromorphological Characteristics of Herbal Acupuncture Needle Tip According to the Number of Injection (자침 횟수에 따른 약침용 주사침첨의 미세 형태 관찰)

  • Lee, Jong-Young;Hwang, Jung-Soo;Kim, Kwang-Ho;Kwon, Ki-Rok;Won, Seung-Hwan
    • Journal of Acupuncture Research
    • /
    • v.22 no.5
    • /
    • pp.49-55
    • /
    • 2005
  • Objectives : In order to ensure safe Herbal Acupuncture treatment, the quality of needle tip is much important. Therefore we investigated micromorphological characteristics of Herbal Acupuncture needle tip according to the number of injection. Methods : We have selected the 26 Gage syringes & 29 Gage syringes that using currently in Herbal Acupuncture treatment. And we evaluated the change of shape of Herbal Acupuncture needle tip after several times of injection by Inverted System Microscope(x 200). Results & Conclusion : We found at Herbal Acupuncture needle tips had several defects such as hooked, scuffed, lump and irregular, stubbed or malformed shape in spite of new syringes. And we found at Herbal Acupuncture needle tips had several defects that is harmful to body such as mild pain, possibility of damage of tissue after several times of injection. Therefore it is necessary to pay attention to use Herbal Acupuncture needle tips.

  • PDF

The effect of the changing of the edged shape of rotary blade by wearing on tilling torque requirement (로우터리 날의 마모(磨耗)에 의(依)한 단면형상변화(斷面形狀變化)가 경운소요(耕耘所要)토오크에 미치는 영향(影響))

  • Kim, Soung Rai;Kwon, Soon Goo
    • Korean Journal of Agricultural Science
    • /
    • v.11 no.2
    • /
    • pp.264-269
    • /
    • 1984
  • The single edged blade was efficient to reduce tilling torque requirement than the double edged blade as previous reported study. This study was carried out to find reducing effects of tilling torque requirement of single edged blade comparing to double edged one in according to wearing by tilling operation. The single and double edged rotary blades were attached on same rotary shaft, and tilling operation was done in hard glass land. The wearing weights of the blade were checked out each 3 hrs tilling operation, at same time, the tilling toruqe requirements were measured with soil bin system in laboratory. The results of the study were summarized as follows: 1. The edged blade shape was not changed during the tilling operation of the rotary blade. The single edged blade was saved 5-10% in the maximum tilling torque and 3-15% in the mean tilling torque than the double edged blade for total durable period. 2. Generally, the tilling torques according to operation were decreased until original shape was maintained, but it was increased after 12 hrs tilling operation, and the tip shape of rotary blade was changed seriously. It is noted that the tip shape of the rotary blade is another factor affecting tilling torque, it should be desirable to study on the rotary blade tip shape to reduce tilling torque requirement after changing its original shape with wearing.

  • PDF

Nasal tip plasty using three-dimensional printed polycaprolactone (Smart Ball®)

  • Kim, Joo Hyoung;Kim, Geon Woo;Kang, Won Kyung
    • Journal of Yeungnam Medical Science
    • /
    • v.37 no.1
    • /
    • pp.32-39
    • /
    • 2020
  • Background: Rhinoplasty is one of the most commonly performed cosmetic surgery procedures. Most Asians desire elevation of their relatively flat nasal dorsum and tip to make them appear more prominent. This study introduces a simple method of nasal tip plasty using three-dimensional (3D)-printed polycaprolactone (PCL) (Smart Ball®), which provides the required length and volume for this purpose and enables the creation of a nasal tip of the desired shape in a safe and simple manner. Methods: Between September 2014 and May 2017, 22 patients participated in a survey to assess postoperative satisfaction levels. Additionally, three plastic surgeons compared patients' pre- and 1-year postoperative photographs to evaluate the results. All patients underwent 2- to 4-year postoperative follow-up. Results: Levels of subjective satisfaction among patients were 3.59, 3.50, 3.82, 3.73, 3.55, and 3.82 for each of the 6 categories evaluated, with a mean of 3.67/4 points, indicating high satisfaction levels. The mean plastic surgeon-reported score for the 22 patients was 4.47/5 points, which also indicates highly successful outcomes. Postoperative nasal tip rotation and tip projection were ideal in most patients. Conclusion: Our novel method using 3D-printed PCL (Smart Ball®) provides the optimal length and volume required for nasal tip plasty and enables the creation of a nasal tip of the desired shape, in a safe and simple manner. An advantage of our method is that it retains the original nasal structure in contrast to structural changes observed with the use of conventional methods.

A study of Main Rotor Blade Tip shape and analysis of flow around Main Rotor Blade Tip (Main Rotor Blade Tip 형상 변화에 따른 유동분석)

  • Kim, Se-Il
    • Proceeding of EDISON Challenge
    • /
    • 2013.04a
    • /
    • pp.382-386
    • /
    • 2013
  • 본 연구에서는 Main Rotor Blade Tip 형상 변화에 따른 후류해석을 통해 와류 생성 및 주변 유동을 분석하여 블레이드 팁 형상의 변화가 와류 간섭을 감소시키는지의 여부를 확인하였다. EDISON CFD를 이용하여 블레이드 Blade Tip 형상에 따라 유동이 어떻게 나타나며, Blade 후류의 압력과 점성의 변화를 분석하여 와류의 양상을 해석하였다. 비교 Blade 형상은 2세대 긴 직사각형 모형, KUH 수리온의 Blade, 유로콥터사의 'Blue Edge'로 비교적 최근에 개발된 대표적인 Blade Tip 형상 3개로 정하였다. 결과를 토대로 블레이드 뒷전의 와류흐름 양상을 확인하여 블레이드 와류 간섭현상의 감소를 확인하였다.

  • PDF

ANALYSIS OF A REVERSED TRAPEZOIDAL FIN USING A 2-D ANALYTIC METHOD

  • Kang, H.S.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • v.14 no.3
    • /
    • pp.151-161
    • /
    • 2010
  • A reversed trapezoidal fin is analyzed using a two-dimensional analytical method. Heat loss from the reversed trapezoidal fin is presented as a function of the fin shape factor, fin base thickness and the fin base height. The relationship between the fin tip length and the convection characteristic number as well as that between the fin tip length and the fin base height for equal amounts of heat loss are analyzed. Also the relationship between the fin base thickness and the fin shape factor for equal amount of heat loss is presented. One of the results shows that the heat loss decreases linearly with the increase of the fin shape factor.

Development of a noncontact optical sensor for measuring the shape of transparent plates (평판 투명 물체의 형상측정을 위한 비접촉식 광센서 개발)

  • 윤상필;유영기
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2000.10a
    • /
    • pp.214-214
    • /
    • 2000
  • This paper deals with the non contact optical sensor to measure the shape of transparent plates such as glass panel of LCD(Liquid Crystal Display). The conventional methods to obtain the shape or thickness of a transparent plates are contact type sensor such as LVOT(Linear Variable Differential Transformer). Due to the contact between the tip of the sensor and the surface of objects, the tip is abraded. In addition, the high temperature glass casting makes the size of sensor body changed. These reasons makes the sensor degraded. In this paper, to overcome these problem, we proposed a low cost noncontact optical sensor this is composed of the Hologram laser unit of a CD-Pickup and a plastic lens. To evaluate the performance of the proposed optical sensor, a series of experiments were performed for various measurement condition. Based upon observation of the experimental result, the developed sensor shows good result for measuring the shape of transparent plates.

  • PDF

Effects of electrode tips on the weldability of galvannealed steel (Galvannealed steel의 점 용접성에 미치는 전극 팁의 영향)

  • 유병길;강춘식
    • Journal of Welding and Joining
    • /
    • v.5 no.3
    • /
    • pp.11-18
    • /
    • 1987
  • Effects of electrode tips shapes of spot welding on the galvannealed steel have been studied, and the results obtained from this studies are as follows. 1) Expulsion had no effect on the shear strength of the specimen but been observed on the tensile strength of the specimen. 2) Effect of holding time after welding was neglegible when the spot welding supplies enough heat input. 3) Depending on the sopt welding tip shape it has different weldbility. It has better weldability in the order of pointed shape, truncated shape and dome shape. But the effect of coolind was just the opposite of the above order.

  • PDF

Aesthetic Rhinoplasty for the Improvement of the Lateral Facial Profile; Image-up Rhinoplasty (얼굴의 측면 윤곽선 개선을 위한 미용 코성형술)

  • Min Sung
    • Archives of Plastic Surgery
    • /
    • v.32 no.2
    • /
    • pp.205-213
    • /
    • 2005
  • There are several characteristics of the nose of orientals. The dorsum of nose is flat and low, the skin is thick with severe tension, the nasal tip is bulbous, the nostril is wide, and the projection of the nose is limited due to a poorly developed alar cartilage with a short columella. In order to improve these untoward characteristics of the nose of Orientals aesthetically, plain augmentation of the dorsum and tip-plasty with conventional methods has been performed by many plastic surgeons. However these conventional rhinoplasty is not enough to obtain satisfactory results when transforming into a more beautiful and aesthetically charming appearance. In order to produce the optimal nasal shape and profile, it is extremely important to consider the aesthetic surgical factors, which are; the position of the nasion, the optimal nasolabial angle(95-100 degree in Orientals), the natural exposure of infra-tip lobule with and columella, the position of the tip defining point in harmony with the dorsal profile and the smooth and natural silhouette of the lateral nasal profile as it descends into the inferior portion of the nose. From April, 2003 to August, 2004, a total of 52 patients underwent open rhinoplasty, adhering to the strict aesthetic principles considered and described priorly. Surgical approach was done through a transcolumella incision and an alar rim incision. The nasal dorsum was augmented with a silicone implant and the shape of the columella and the nasolabial angle were finessed with a silicone strut implant which was placed in between the medial crurae in a manner of a non-visible graft. The nasal tip was corrected by alar cartilage suture technique and onlay graft of shield shaped Alloderm and Gore-Tex. Author obtained the optimal nasal shape and profile aesthetically, and the results, considered satisfactory in all patients without any complications, are as follows; 1. the average increase in nasal length was 2.5 mm, 2. the average decrease in nasal width was 2.1 mm, 3. the average increase in nasal tip projection was 3.2 mm, 4. the changes of nasolabial angles were from 85.5 degree to 94.7 degree, 5. the changes of the angle between the long axis of the external naris was from 101.3 degree to 89.5 degree. In conclusion, this surgical procedure is an effective, reliable and a valuable method in improving the nasal shape, tip projection, nasolabial angle and especially, the lateral facial profile of Orientals aesthetically.

A Study on the AC Treeing Characteristics with Tip Radius of Needle Electrode in LLDPE/EVA (침전극 곡률반경에 따른 LLDPE/EVA의 교류트리 특성)

  • Lee, Jae-Pil;Lee, Chung-Ho
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2003.07a
    • /
    • pp.476-480
    • /
    • 2003
  • Polyethylene used as insulating material of power cable is nonpolar and low dielectric loss polymer. But it has defects of tree generation and accumulation of space charge by an applied voltage resulting in the decreased life and performance. To solve these problems, mixed films with LLDPE and EVA that is similar to LLDPE at physical properties in case of low VA contents were made and tested due to the blend ratios of 80:20, 70:30, 60:40 and 50:50[wt%] respectively. We investigated AC electrical treeing characteristics to acquire the best mixture ratio and effect of the tip radius of needle electrode to develop excellent treeproof materials. The degree of crystallity calculated with XRD pattern is higher for pure LLDPE, 50:50 and 70:30. For DSC analysis, it is confirmed that the melting points of mixed specimens are lower than that of pure LLDPE and higher than pure EVA's. The shape of tree propagation showed that pure EVA was electrical tree shape of the branch type, pure LLDPE and blended specimens was able to confirm tree shape of the bush type. As the tip radius go up in the blend ratio 70:30 specimen, the tree inception voltage rise. Probably the reason is the relaxation of electric field in the specimen with bigger tip ratio. As the 6 specimens were applied AC 5[KV],7.5[KV],10[KV] respectively, tree growth length is far shorter in the specimen with blend ratio 70:30, 50:50 than in pure EVA and pure LLDPE specimen. Conclusively, it is confirmed that specimens of which blend ratio are 70:30 and 50:50 are good in electrical tree retardant characteristics, especially, 70:30 has lower dielectric loss than 50:50 and its mixture ratio is the best.

  • PDF

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • v.43 no.4
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.