• Title/Summary/Keyword: tip position

검색결과 372건 처리시간 0.025초

An analysis on the factors responsible for relative position of interproximal papilla in healthy subjects

  • Kim, Joo-Hee;Cho, Yun-Jung;Lee, Ju-Youn;Kim, Sung-Jo;Choi, Jeom-Il
    • Journal of Periodontal and Implant Science
    • /
    • 제43권4호
    • /
    • pp.160-167
    • /
    • 2013
  • Purpose: This study examined the factors that can be associated with the appearance of the interproximal papilla. Methods: One hundred and forty-seven healthy interproximal papillae between the maxillary central incisors were examined. For each subject, a digital photograph and periapical radiograph of the interdental embrasure were taken using a 1-mm grid metal piece. The following parameters were recorded: the amount of recession of the interproximal papilla, contact point-bone crest distance, contact point-cemento-enamel junction (CEJ) distance, CEJ-bone crest distance, inter-radicular distance, tooth shape, embrasure space size, interproximal contact area, gingival biotype, papilla height, and papilla tip form. Results: The amount of recession of the interproximal papilla was associated with the following: 1) increase in contact point-bone crest, contact point-CEJ, and CEJ-bone crest distance; 2) increase in the inter-radicular distance; 3) triangular tooth shape; 4) decrease in the interproximal contact area length; 5) increase in the embrasure space size; and 6) flat papilla tip form. On the other hand, the amount of gingival recession was not associated with the gingival biotype or papilla height. In the triangular tooth shape, the contact point-bone crest distance and inter-radicular distance were longer, the interproximal contact area length was shorter, and the embrasure space size was larger. The papilla tip form became flatter with increasing inter-radicular distance and CEJ-bone crest distance. Conclusions: The relative position of the interproximal papilla in healthy subjects was associated with the multiple factors and each factor was related to the others. A triangular tooth shape carries a higher risk of recession of the interproximal papilla because the proximal contact point is positioned more incisally and the bone crest is positioned more apically. This results in an increase in recession of the interproximal papilla and flat papilla tip form.

얼굴의 측면 윤곽선 개선을 위한 미용 코성형술 (Aesthetic Rhinoplasty for the Improvement of the Lateral Facial Profile; Image-up Rhinoplasty)

  • 김성민
    • Archives of Plastic Surgery
    • /
    • 제32권2호
    • /
    • pp.205-213
    • /
    • 2005
  • There are several characteristics of the nose of orientals. The dorsum of nose is flat and low, the skin is thick with severe tension, the nasal tip is bulbous, the nostril is wide, and the projection of the nose is limited due to a poorly developed alar cartilage with a short columella. In order to improve these untoward characteristics of the nose of Orientals aesthetically, plain augmentation of the dorsum and tip-plasty with conventional methods has been performed by many plastic surgeons. However these conventional rhinoplasty is not enough to obtain satisfactory results when transforming into a more beautiful and aesthetically charming appearance. In order to produce the optimal nasal shape and profile, it is extremely important to consider the aesthetic surgical factors, which are; the position of the nasion, the optimal nasolabial angle(95-100 degree in Orientals), the natural exposure of infra-tip lobule with and columella, the position of the tip defining point in harmony with the dorsal profile and the smooth and natural silhouette of the lateral nasal profile as it descends into the inferior portion of the nose. From April, 2003 to August, 2004, a total of 52 patients underwent open rhinoplasty, adhering to the strict aesthetic principles considered and described priorly. Surgical approach was done through a transcolumella incision and an alar rim incision. The nasal dorsum was augmented with a silicone implant and the shape of the columella and the nasolabial angle were finessed with a silicone strut implant which was placed in between the medial crurae in a manner of a non-visible graft. The nasal tip was corrected by alar cartilage suture technique and onlay graft of shield shaped Alloderm and Gore-Tex. Author obtained the optimal nasal shape and profile aesthetically, and the results, considered satisfactory in all patients without any complications, are as follows; 1. the average increase in nasal length was 2.5 mm, 2. the average decrease in nasal width was 2.1 mm, 3. the average increase in nasal tip projection was 3.2 mm, 4. the changes of nasolabial angles were from 85.5 degree to 94.7 degree, 5. the changes of the angle between the long axis of the external naris was from 101.3 degree to 89.5 degree. In conclusion, this surgical procedure is an effective, reliable and a valuable method in improving the nasal shape, tip projection, nasolabial angle and especially, the lateral facial profile of Orientals aesthetically.

완전이식형 정맥 접근 포트 삽입 시 카테터 팁을 심벽에 닿지 않고 우심방 내 위치시키는 방법의 타당성과 안전성 (Feasibility and Safety of a Technique Intended to Place the Catheter Tip in the Right Atrium without Abutment Against the Cardiac Wall during Implantation of the Totally Implantable Venous Access Port)

  • 박혜진;서태석;송명규;양우진
    • 대한영상의학회지
    • /
    • 제85권1호
    • /
    • pp.161-170
    • /
    • 2024
  • 목적 완전이식형 정맥 접근 포트 이식 시 카테터 팁을 심벽에 닿지 않으면서 우심방 내 위치시키는 기술의 타당성과 안전성에 대하여 평가하였다. 대상과 방법 2016년 1월부터 12월까지 완전이식형 정맥 접근 포트를 삽입하고 추적관찰 CT를 시행한 환자 총 330명이 연구에 포함되었다. 정맥 접근 포트는 절개선에서 직접 액와정맥으로 접근하는 단일절개법을 적용하여 이식하였다. 카테터 팁을 자르기 전 정맥 환류를 확인하여 우심방 내벽에 닿지 않도록 위치를 확인하였다. 카테터의 길이 및 연관된 합병증은 의료영상 그리고 의료기록을 통해 후향적으로 평가하였다. 결과 모든 환자에서 카테터 팁은 심벽과의 닿음과 기능장애 없이 성공적으로 위치 조정되었다. 카테터 팁의 위치는 cavoatrial junction 기준으로 fluoroscopy에서 15.3 mm, 첫 번째 CT에서 6 mm 원위부에 있었다(중앙값). 카테터 팁은 fluoroscopy 대비 첫 번째 CT에서 10.4 mm 머리 방향으로 이동하였다(중앙값). 추적 CT에서 우심방과 상대정맥에서 각각 1건씩의 혈전증이 발견되었다. 결론 카테터 팁을 심벽에 닿지 않으면서 우심방 내 의도적으로 위치시키는 것은 혈전증 발생률이 낮고 기능장애가 없는 기술적으로 가능하고 안전한 방법이다.

Tip Enhanced Nano Raman Scattering in Graphene

  • Mun, Seok Jeong
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.87.2-87.2
    • /
    • 2016
  • As an era of nano science approaches, the understanding on the shape and optical properties of various materials in a nanoscale range is getting important more seriously than ever. Accordingly the development of high spatial-temporal-spectral resolution measurement tools for characterization of nanomaterials/structures is highly required. Generally, the various properties of sample can be measured independently, e.g. to observe the structural property of sample, we use the scanning electron microscopy or atomic force microscopy, and to observe optical property, we have to use another independent measurement tool such as photoluminescence spectroscopy or Raman spectroscopy. In the case of nano-materials, however, it is very difficult to find out the same position of sample at every different measurement processes, and the condition of sample can be changed by the influence of first measurement. The tip enhanced Raman scattering(TERS), which can simultaneously measure the two or more information of sample with nanoscale spatial resolution, is one of solutions of this problem. In this talk, I will present our recent nano Raman scattering data of graphene that measured by TERS and optimized tip fabrication method for efficient experiment.

  • PDF

하악골 골절시 사용되는 TRANSBUCCAL TROCAR TIP의 새로운 고안 (DESIGN OF TRANSBUCCAL TROCAR TIP USED IN MANDIBULAR ANGLE FRACTURES)

  • 안병근;이건주;한호진;박형태
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제11권1호
    • /
    • pp.87-92
    • /
    • 1989
  • Transbuccal trocar has been an established method of fixation for the bone plate in the case of mandibular angle fracture. Other than extraoral approaches, this transbuccal approach has many advantages in the treatment of the fracture of mandibular angle. These advantages are as follows ; (1) Damage to the facial nerve branches is minimal. (2) Less postoperative scar is formed. (3) Good vision of occlusion can be easily obtained on the entire operation. (4) Shorter operation time is needed. But, in the clinical procedure of plate fixation, it is has a difficulty in manipulation of the plate and correction of position. To solve these problems, we designed and used a trocar tip which can be easily attached to the trocar, and could make an improvement in the clinical procedures.

  • PDF

전자현미경 영상을 이용한 나노 비주얼 서보잉 (Nano Visual Servoing Loop Using SEM Image)

  • 최진호;안상정;박병천;유준
    • 전기학회논문지
    • /
    • 제57권10호
    • /
    • pp.1876-1882
    • /
    • 2008
  • Nano manipulator is used to manufacture Carbon NanoTube(CNT) tips. Using nano manipulator, operator attaches a CNT at the apex of Atomic Force Microscope(AFM) tip, which requires a mastery of mechanics and long manufacture time. Nano manipulator is installed inside a Scanning Electron Microscope(SEM) chamber to observe the operation. This paper presents a control scheme for horizontal axes of nano manipulator via processing SEM image. Edges of AFM tip and CNT are first detected, and the position information so obtained is fed to control horizontal axes of nano manipulator. That is, a visual servoing loop is realized to control the axes more precisely in nano scale.

풍력터빈 블레이드상의 공력하중분포 해석 (Spanwise Aerodynamic Loads along the Wind Turbine Blade)

  • 이교열;유기완
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2011년도 춘계학술대회 초록집
    • /
    • pp.61.2-61.2
    • /
    • 2011
  • The spanwise aerodynamic loads of the wind turbine blade are investigated numerically. The blade shape such as twist and chord length along the blade span is obtained from the procedure of aerodynamically optimal design. The rated tip speed ratio and the rated wind velocity are set to 7 and 12m/s respectively. The BEM method is applied to obtain both the aerodynamic performance of the wind turbine (Fig.1) and the spanwise aerodynamic loads along the blade span including Prandtl's tip loss factor. The maximum running power coefficient is occurred around 90% radial position from hub (Fig.2). The distributed aerodynamic loads along the blade span can be used for structure analysis.

  • PDF

역학을 이용한 탄성 로보트 아암의 선단 위치 제어 기어에 대한 연구 (A Study on the Position Control Improvement of Flexible Robot Arm by Inverse Dynamics)

  • 방두열;이성철
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 춘계학술대회 논문집
    • /
    • pp.9-13
    • /
    • 1997
  • This parer is a study on the inverse dynamics of a one-link flexible robot arm which is controlled by translational base motion. The system is composed of a flexible arm, a base for driving arm, a DC servomotor, and a computer. The arm base is moved so that the arm tip follows a desired function. The governing equations are based on the Bernoullie-Euler beam theory and solved by applying the Laplace transform method and then the numerical inversion method. Moter voltage is obtained by simulation for tip trajectory functions i. e. Bang-Bang, Cosine and Gauss Function. And, the tip motion is measured while simulation results are applying. Then the results are investigated to select most proper input and to compare their chateristics. Experimental results show the Cosine function is most proper with respect to low maximum voltage and steady state error.

  • PDF

유체유동 외팔 파이프의 안정성에 미치는 크랙의 영향 (Effects of Crack on Stability of Cantilever Pipe Conveying Fluid)

  • 손인수;윤한익;김동진
    • 한국소음진동공학회논문집
    • /
    • 제17권11호
    • /
    • pp.1119-1126
    • /
    • 2007
  • In this paper, the dynamic stability of a cracked cantilever pipe conveying fluid with tip mass is investigated. The pipe is modelled by the Euler-Bernoulli beam theory in which rotatory inertia and shear deformation effects are ignored. The equation of motion is derived by the energy expressions using extended Hamilton's Principle. The crack section is represented by a local flexibility matrix connecting two undamaged pipe segments. The influence of the crack severity, the position of crack, the mass ratio, and a tip mass on the stability of a cantilever pipe conveying fluid are studied by the numerical method. Besides, the critical flow velocity and the stability maps of the pipe system as a function of mass ratios($\beta$) for the changing each parameter are obtained.

Analysis of the Motion of a Cart with an Inverted Flexible Beam and a Concentrated Tip Mass

  • Park, Sangdeok;Wankyun Chung;Youngil Youm;Lee, Jaewon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1998년도 제13차 학술회의논문집
    • /
    • pp.367-372
    • /
    • 1998
  • In this paper, the mathematical model of a cut with an inverted flexible beam and a concentrated tip mass was derived. The characteristic equation for calculating the natural frequencies of the cart-beam-mass system was obtained and the motion of the system was analyzed through unconstrained modal analysis. A good positioning response of the cart without excessive vibrational motion of the tip mass could be obtained through numerical simulation using PID controller with the feedback of both the position of the cart and the deflection of the beam.

  • PDF