• Title/Summary/Keyword: tip position

Search Result 372, Processing Time 0.025 seconds

A Study on the Performance Variation of a Three-Dimensional Hydrofoil Using Jet Flow

  • Eom, Myeong-Jin;Paik, Kwang-Jun;Lee, Ju-Han;Kang, Shin-Min;Kim, Dong-Young
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.1
    • /
    • pp.24-37
    • /
    • 2021
  • As one of the development directions of high-performance ships to reduce greenhouse gas emissions, there is research on high-performance propellers. However, in the case of conventional screw propellers, as they have been studied for a long time, there is a limit to improving efficiency only by depending on the conventional design and analysis methods. In this study, we tried to solve the problems using the Coanda effect by spraying a jet on the surface of the hydrofoil. The Coanda hydrofoil consists of a tunnel and jet slit to make jet flow. The computation was performed for each tunnel and slit position, and the efficiency according to the geometry of the hydrofoil was analyzed. In addition, a study on the 3D geometry change was conducted to analyze the performance according to the span direction spraying range and hydrofoil shape. As the height of the slit and the diameter of the tip were lower, when the slit is located in the center of the hydrofoil, the lift force increased and the drag force decreased. The increase rate of lift-to-drag ratio was different according to the shape of the hydrofoil, and the efficiency of the spraying condition of 0.1S-0.5S, which had the least effect on the vortex at the tip of the blade, was high for all 3D hydrofoils. When the geometry of the slit was optimized, and also the shape and spray range of the hydrofoil in 3D was considered, the efficiency of the jet sprayed hydrofoil was increased.

Study of cracks in compressed concrete specimens with a notch and two neighboring holes

  • Vahab, Sarfarazi;Kaveh, Asgari;Shirin, Jahanmiri;Mohammad Fatehi, Marji;Alireza Mohammadi, Khachakini
    • Advances in concrete construction
    • /
    • v.14 no.5
    • /
    • pp.317-330
    • /
    • 2022
  • This paper investigated computationally and experimentally the interaction here between a notch as well as a micropore under uniaxial compression. Brazilian tensile strength, uniaxial tensile strength, as well as biaxial tensile strength are used to calibrate PFC2d at first. Then, uniaxial compression test was conducted which they included internal notch and micro pore. Experimental and numerical building of 9 models including notch and micro pore were conducted. Model dimensions of models are 10 cm × 10 cm × 5 cm. Joint length was 2 cm. Joints angles were 30°, 45° and 60°. The position of micro pore for all joint angles was 2cm upper than top of the joint, 2 cm upper than middle of joint and 2 cm upper than the joint lower tip, discreetly. The numerical model's dimensions were 5.4 cm × 10.8 cm. The fractures were 2 cm in length and had angularities of 30, 45, and 60 degrees. The pore had a diameter of 1 cm and was located at the top of the notch, 2 cm above the top, 2 cm above the middle, and 2 cm above the bottom tip of the joint. The uniaxial compression strength of the model material was 10 MPa. The local damping ratio was 0.7. At 0.016 mm per second, it loaded. The results show that failure pattern affects uniaxial compressive strength whereas notch orientation and pore condition impact failure pattern. From the notch tips, a two-wing fracture spreads almost parallel to the usual load until it unites with the sample edge. Additionally, two wing fractures start at the hole. Both of these cracks join the sample edge and one of them joins the notch. The number of wing cracks increased as the joint angle rose. There aren't many AE effects in the early phases of loading, but they quickly build up until the applied stress reaches its maximum. Each stress decrease was also followed by several AE effects. By raising the joint angularities from 30° to 60°, uniaxial strength was reduced. The failure strengths in both the numerical simulation and the actual test are quite similar.

INFRARED THERMOGRAPHIC ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER (적외선열화상장치를 이용한 Buchanan plugger 표면의 온도상승 분석)

  • Choi, Sung-A;Kim, Sun-Ho;Hwang, Yun-Chan;Youn, Chang;Oh, Byung-Ju;Choi, Bo-Young;Juhng, Woo-Nam;Jeong, Sun-Wa;Hwang, In-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.4
    • /
    • pp.370-381
    • /
    • 2002
  • This study was performed to evaluate the temperature rise on various position of the Buchanan plugger, the peak temperature of plugger's type and the temperature change by its touching time of heat control spling. The heat carrier system 'System B' (Model 1005, Analytic Technologies, USA) and the Buchanan's plug-gers of F, FM, M and ML sizes are used for this study. The temperature was set to 20$0^{\circ}C$ which Dr. Buchanan's "continuous wave of condensation" technique recommended on digital display and the power level on it was set to 10. In order to apply heat on the Buchanan's pluggers, the heat control spring was touched for 1, 2, 3, 4 and 5 seconds respectively. The temperature rise on the surface of the pluggers were measured at 0.5 mm intervals from tip to 20 mm length of shank using the infrared thermography (Radiation Thermometer-IR Temper, NEC San-ei Instruments, Ltd, Japan) and TH31-702 Data capture software program (NEC San-ei Instruments, Ltd, Japan). Data were analyzed using a one way ANOVA followed by Duncan's multiple range test and linear regression test. The results as follows. 1. The position at which temperature peaked was approximately at 0.5 mm to 1.5 mm far from the tip of Buchanan's pluggers (p<0.001). The temperature was constantly decreased toward the shank from the tip of it (p<0.001). 2. When the pluggerss were heated over 5 seconds, the peak temperature by time of measurement revealed from 253.3$\pm$10.5$^{\circ}C$ to 192.1$\pm$3.3$^{\circ}C$ in a touch for 1 sec, from 218.6$\pm$5.$0^{\circ}C$ to 179.5$\pm$4.2$^{\circ}C$ in a touch for 2 sec, from 197.5$\pm$3.$0^{\circ}C$ to 167.5$\pm$3.7$^{\circ}C$ in a touch for 3 sec, from 183.7$\pm$2.5$^{\circ}C$ to 159.8$\pm$3.6$^{\circ}C$ in a touch for 4 sec and from 164.9$\pm$2.$0^{\circ}C$ to 158.4$\pm$1.8$^{\circ}C$ in a touch for 5 sec. A touch for 1 sec showed the highest peak temperature, followed by, in descending order, 2 sec, 3 sec, 4 sec. A touch for 5 sec showed the lowest peak temperature (p<0.001). 3. A each type of pluggers showed different peak temperatures. The peak temperature was the highest in F type and followed by, in descending order, M type, ML type. FM type revealed the lowest peak temperature (p<0.001). The results of this study indicated that pluggers are designed to concentrate heat at around its tip, its actual temperature does not correlate well with the temperature which Buchanan's "continuous wave of condensation" technique recommend, and finally a quick touch of heat control spring for 1sec reveals the highest temperature rise.

Analysis of Component Changes According to Early Cutting of Elk Velvet Antlers (엘크사슴 녹용의 조기 절각에 따른 성분변화 분석)

  • Kim, Dong-kyo;Lee, Sang-Hoon;Lee, Eun-Do;Lee, Jinwook;Roh, Hee-Jong;Lee, Sung-Soo;Jang, Aera;Kim, Kwan-Woo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.22 no.2
    • /
    • pp.565-576
    • /
    • 2021
  • This study was undertaken to measure changes in the composition of elk velvet antlers, by considering the part and growth days (40th day, 60th day). The collected samples were divided into the tip, upper, middle, and base part by position. Samples were analyzed for moisture, crude protein, crude fat, crude ash, crude fiber, pH, minerals, and fatty acid and amino acid contents. The amounts of crude protein and crude fat were determined to be highest at the tip of the velvet antler by position, whereas dry matter and crude ash were high at the base. Crude protein contents were increased in the upper part but were decreased at the base, when assessed by growth day. Conversely, crude fiber and crude ash were found to be increased at the base by growth day. The pH value was determined to be lower at the tip, but did not differ when evaluated by growth day. Mineral contents (Ca, P, K) differed significantly by growth day in the middle portion of the antler. Saturated fatty acids tended to increase by growth day, whereas unsaturated fatty acids showed a decreasing trend. However, no significant difference was obtained for any of the components. Most amino acids were found to be high in the 60 days velvet antler, except isoleucine (Ile), which showed low levels at day 60. These results provide information on the changes in the composition of antlers, in cases of early cutting.

Pallidotomy Guided by MRI and Microrecording for Parkinson's Disease (파킨슨환자의 자기공명영상과 미세전극기록을 이용한 담창구 파괴술)

  • Lee, Kyung Jin;Son, Hyung Sun;Park, Sung Chan;Cho, Kyung Keun;Park, Hae Kwan;Choi, Chang Rak
    • Journal of Korean Neurosurgical Society
    • /
    • v.30 no.1
    • /
    • pp.41-46
    • /
    • 2001
  • Objective : The exact position of the lesion during the pallidotomy is critical to obtain the clinical improvement of parkinson's disease without damage to surrounding structure. Ventriculogrphy, CT(computed tomograpy) or MRI(magnetic resonance imaging) have been used to determine the initial coordinates of stereotactic target for pallidotomy. The goal of this study was to determine whether microelectrode recording significantly improves the neurophysiologic localization of the target obtained from MRI. Methods : Twenty patients were studied. They underwent a unilateral pallidotomy. Leksell frame was applied and T1 axial images parallel to the AC-PC(anterior commissure-posterior commissure) plane using a 1.5 Tesla MRI with 3mm slice thickness were obtained. Anteroposterior coordinate of target was chosen at 2mm in front of the midcommissural point and lateral coordinate between 19 and 22mm from the midline. The vertical coordinate was calculated on coronal slice using a fast spin echo inversion recovery sequence(FSEIR) related to the position of the choroidal fissure and ranged over 4-5mm below the AC-PC plane. Confirmation of the anatomical target was done on axial slices using the same FSEIR sequence . Microrecording was done at the pallidum contralateral to the symptomatic side using an electrode with a tip diameter of $1{{\mu}m}$ diameter tip and 1.1-1.4 mOhm impedance at 1000Hz. Electrophysiologic localization of the target was also confirmed intraoperatively by macrostimulation. Results : Microrecording techniques were reliable to define the transition from the base of the pallidum which was characterized by the disappearance of spike activity and by the change of the audible background activity. Signals from high amplitude neurons firing at 200-400Hz were recorded in the pallidal base. X, Y and Z coordinates of target obtained from the MRI were within 1mm from the X, Y, Z coordinates obtained with microrecording in 16 patients (80%), 15 patients(75%), 10 patients(50%) respectively. The difference of Y coordinate between on MRI and on microrecording was 4mm in only one patient. Conclusion : The MRI was accurate to localize the target within 1mm of the error from microrecording target in 70% of the patients. 4mm discrepancy was observed only once. We conclude that MRI alone can be used to determine the target for pallidotomy in most patients. However, microrecording technique can still be extremely valuable in patents with aberrant anatomy or unusual MRI coordinates. We also consider physiologic confirmation of the target using macrostimulation to be mandatory in all cases.

  • PDF

Novel condylar repositioning method for 3D-printed models

  • Sugahara, Keisuke;Katsumi, Yoshiharu;Koyachi, Masahide;Koyama, Yu;Matsunaga, Satoru;Odaka, Kento;Abe, Shinichi;Takano, Masayuki;Katakura, Akira
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.40
    • /
    • pp.4.1-4.4
    • /
    • 2018
  • Background: Along with the advances in technology of three-dimensional (3D) printer, it became a possible to make more precise patient-specific 3D model in the various fields including oral and maxillofacial surgery. When creating 3D models of the mandible and maxilla, it is easier to make a single unit with a fused temporomandibular joint, though this results in poor operability of the model. However, while models created with a separate mandible and maxilla have operability, it can be difficult to fully restore the position of the condylar after simulation. The purpose of this study is to introduce and asses the novel condylar repositioning method in 3D model preoperational simulation. Methods: Our novel condylar repositioning method is simple to apply two irregularities in 3D models. Three oral surgeons measured and evaluated one linear distance and two angles in 3D models. Results: This study included two patients who underwent sagittal split ramus osteotomy (SSRO) and two benign tumor patients who underwent segmental mandibulectomy and immediate reconstruction. For each SSRO case, the mandibular condyles were designed to be convex and the glenoid cavities were designed to be concave. For the benign tumor cases, the margins on the resection side, including the joint portions, were designed to be convex, and the resection margin was designed to be concave. The distance from the mandibular ramus to the tip of the maxillary canine, the angle created by joining the inferior edge of the orbit to the tip of the maxillary canine and the ramus, the angle created by the lines from the base of the mentum to the endpoint of the condyle, and the angle between the most lateral point of the condyle and the most medial point of the condyle were measured before and after simulations. Near-complete matches were observed for all items measured before and after model simulations of surgery in all jaw deformity and reconstruction cases. Conclusions: We demonstrated that 3D models manufactured using our method can be applied to simulations and fully restore the position of the condyle without the need for special devices.

ANALYSIS OF TEMPERATURE RISE ON THE SURFACE OF BUCHANAN PLUGGER USING THERMOCOUPLE (열전대(thermocouple)를 이용한 Buchanan Plugger 표면의 온도상승 분석)

  • Cho, Jin-Suk;Hwang, Yun-Chan;Kim, Sun-Ho;Hwang, In-Nam;Choi, Bo-Young;Jeong, Young-Jin;Juhng, Woo-Nam;Oh, Won-Mann
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.4
    • /
    • pp.334-340
    • /
    • 2003
  • This study was performed to evaluate the actual temperature rise on the surface of Buchanan plugger using thermocouple. The heat carrier system 'System B Heatsource'(Model 1005, Analytic Technologies, Redmond, WA, USA) and the Buchanan pluggers of F, FM, M and ML sizes are used for this study. The temperature was set to 200^{\circ}C on digital display and the power level on it was set to 10. Five thermocouples were placed in direct contact with the surface of each size of Buchanan's pluggers at 1 mm increments from the tip to the 4 mm length of shank. The heat control spring was touched for 5 seconds. and the temperature rise on the surface of the pluggers were measured at 1 sec intervals for more than 5 seconds with an accuracy of 0.01 using Data Logger. The data were statistically analyzed by one-way ANOVA. The results were as follows. 1. The position at which the temperature peaked was approximately at 1~2 mm far from the tip of Buchanan plugger (p<0.01). 2. The peak temperature was $215.25{\pm}2.28^{\circ}C$ in F plugger. $185.94{\pm}2.19^{\circ}C$ in FM plugger, $169.51{\pm}9.12^{\circ}C$ in M plugger, and 160.79{\pm}1.27^{\circ}C in ML plugger and the peak temperature was highest in F plugger and followed by. in descending order. FM plugger. M plugger. ML plugger showed the lowest peak temperature (p<0.01). 3. The temperature on the plugger was decreased with the increase of touching time. This results suggest that the actual temperature on the surface of the pluggers does not correlate well with the temperature set on digital display. Heat concentrates around the tip. The larger plugger reveals lower temperature rise relatively.

The influence of tunnelling on the behaviour of pre-existing piled foundations in weathered soil

  • Lee, Cheol-Ju;Jeon, Young-Jin;Kim, Sung-Hee;Park, Inn-Joon
    • Geomechanics and Engineering
    • /
    • v.11 no.4
    • /
    • pp.553-570
    • /
    • 2016
  • A series of three-dimensional (3D) parametric finite element analyses have been performed to study the influence of the relative locations of pile tips with regards to the tunnel position on the behaviour of single piles and pile groups to adjacent tunnelling in weathered soil. When the pile tips are inside the influence zone, which considers the relative pile tip location with respect to the tunnel position, tunnelling-induced pile head settlements are larger than those computed from the Greenfield condition. However, when the pile tips are outside the influence zone, a reverse trend is obtained. When the pile tips are inside the influence zone, the tunnelling-induced tensile pile forces mobilised, but when the pile tips are outside the influence zone, compressive pile forces are induced because of tunnelling, depending on the shear stress transfer mechanism at the pile-soil interface. For piles connected to a cap, tensile and compressive forces are mobilised at the top of the centre and side piles, respectively. It has been shown that the increases in the tunnelling-induced pile head settlements have resulted in reductions of the apparent factor of safety up to approximately 43% when the pile tips are inside the influence zone, therefore severely affecting the serviceability of the piles. The pile behaviour, when considering the location of the pile tips with regards to the tunnel, has been analysed in great detail by taking the tunnelling-induced pile head settlements, axial pile forces, apparent factor of safety of the piles and shear transfer mechanism into account.

The relationship of maxillary canines to the facial anatomical landmarks in a group of Thai people

  • Sinavarat, Potchaman;Anunmana, Chuchai;Hossain, Sharafat
    • The Journal of Advanced Prosthodontics
    • /
    • v.5 no.4
    • /
    • pp.369-373
    • /
    • 2013
  • PURPOSE. The objective was to evaluate canine positions, intercanine tip width (ICTW) and width of distal surface of canine (WDC), related to facial landmarks including interalar width (IAW), intercommissural width (ICoW), and distance between left and right projection lines drawn from inner canthus of eyes to alae of the nose (DPICa) in a group of Thai. MATERIALS AND METHODS. One hundred Thai subjects aged 18-35 years were selected. IAW and ICoW were measured on subject's face using digital vernier caliper. Irreversible hydrocolloid impression of the upper arch was taken, and a cast was poured with dental stone. Silicone impression material was used to take imprint of the incisal edge of upper six anterior teeth. DPICa was obtained from the subject's face using custom-made measuring equipment and marked on the silicone incisal imprint. The marks were then transferred from the imprint to the stone cast and measured with digital caliper. The ICTW and WDC were also measured on the stone cast. Pearson's correlation was used to determine the correlation. RESULTS. The results revealed that the correlation between ICTW-ICoW was 0.429 and ICTW-DPICa was 0.573. The correlation between WDC-ICoW was 0.426 and WDC-DPICa was 0.547. However, IAW did not show any correlation with ICTW or WDC (P>.05). CONCLUSION. The correlation between canine position and facial landmarks was found. ICTW and WDC had relationship with ICoW and DPICa. DPICa showed stronger correlation with the position of maxillary canine than that of ICoW.

Cephalometric Variables Significantly Associated with Apnea Hypopnea Index in Suspected Obstructive Sleep Apnea Patients : A Preliminary Study (폐쇄성수면무호흡 의심환자에서 무호흡-저호흡 지수와 연관이 있는 두개골 계측 변수 : 예비연구)

  • Park, Suyoung;Hwang, Hee Young;Kim, Eung Yeop;Kang, Seung-Gul;Kim, Seon Tae;Park, Kee Hyung
    • Korean Journal of Biological Psychiatry
    • /
    • v.22 no.1
    • /
    • pp.14-19
    • /
    • 2015
  • Objectives The purpose of this study is to find the cephalometric variables which are significantly correlated with the apnea-hypopnea index (AHI) in suspected Korean obstructive sleep apnea (OSA) patients. Methods We examined lateral cephalogram and attended-full night laboratory polysomnography of the 40 participants who complained of OSA symptoms. The correlation analysis was conducted to find the cephalometric variables which are significantly correlated with the AHI. Results The correlation analysis showed that the higher AHI was associated with the longer distance between hyoid and mandibular plane (p = 0.023), the longer distance between C3 and hyoid (p = 0.014), the longer tongue length (p = 0.003), the larger inferior tongue area (p = 0.008), the larger anterior displacement of the hyoid bone (p = 0.024), the longer distance between posterior nasal spine and the tip of the soft palate (p = 0.021), and the larger cross-sectional area of soft palate (p = 0.001) of cephalogram in erect position. The higher AHI was correlated with the longer distance between hyoid and mandibular plane (p = 0.008), the longer tongue length (p = 0.037), the larger inferior tongue area (p = 0.013), the thicker uvula (p = 0.004), the longer distance between retrognathion and hyoid (p = 0.025), and larger cross-sectional area of soft palate (p = 0.001) of cephalogram in supine position. Conclusions The present preliminary results showed the candidate measurements of cephalogram which are significantly correlated with the AHI in suspected OSA.