Analysis of the Magnetic Field and Eddy Current Characteristics in Isolated Phase Bus System (상분리 모선의 자계 및 와전류 특성 해석)

  • Kim, Jin-Su;Ha, Deok-Yong;Choe, Seung-Gil;Gang, Hyeong-Bu
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.50 no.10
    • /
    • pp.509-516
    • /
    • 2001
  • Isolated phase bus(IPS) has a special structure for carrying large current generated by a generator to a main transformer. In the analysis of IPB, the understanding of the magnetic field distribution generated by large current is important. Especially, while the bus conductor current is flowing, almost same amount of current as bus conductor current is induced in the enclosures under the influence of time varying magnetic field, and therefore the large electric loss and the deterioration of insulating capability might occur due to Joule heating effect. Hence for the optimal design of IPB satisfying the condition to minimize the loss, the accurate analysis of magnetic field distribution and the eddy current characteristics of three phase isolated phase bus have been investigated. In the analysis of time varying magnetic field, instead of finite difference method(FDM) which is generally used, finite element method with phasor concept is investigated under the assumption that the bus current is purely sinusoidal. The characteristics is studied along the phase angle by comparing the effect of eddy current on the magnetic field distribution with the case that eddy current is not considered, and also the effect of material, thickness and radius of enclosure on the eddy current distribution is discussed.

  • PDF

Load Disturbance Compensation for Stand-alone Inverters Using an Inductor Current Observer

  • Choe, Jung-Muk;Moon, Seungryul;Byen, Byeng-Joo;Lai, Jih-Sheng;Lim, Young-Bae;Choe, Gyu-Ha
    • Journal of Power Electronics
    • /
    • v.17 no.2
    • /
    • pp.389-397
    • /
    • 2017
  • A control scheme for stand-alone inverters that utilizes an inductor current observer (ICO) is proposed. The proposed method measures disturbance load currents using a current sensor and it estimates the inductor current using the ICO. The filter parameter mismatch effect is analyzed to confirm the ICO's controllability. The ICO and controllers are designed in a continuous-time domain and transferred to a discrete-time domain with a digital delay. Experimental results demonstrate the effectiveness of the ICO using a 5-kVA single-phase stand-alone inverter prototype. The experimental results demonstrate that the observed current matches the actual current and that the proposed method can archive a less than 2.4% total harmonic distortion (THD) sinusoidal output waveform under nonlinear load conditions.

Realization of 3.3V active low-pass filter using improved continuous-time current-mode CMOS integrator (개선된 연속시간 전류모드 CMOS 적분기를 이용한 3.3V 능동 저역필터 구현)

  • 방준호;조성익;이성룡;권오신;신홍규
    • Journal of the Korean Institute of Telematics and Electronics B
    • /
    • v.33B no.4
    • /
    • pp.52-62
    • /
    • 1996
  • In this paper, a new continuous-time current-mode integrator as basic building block of the low-voltage analog current-mode active filters was proposed. Compared to the current-mode integrator which was proposed by Zele, the proposed current-mode integrator had higher unity gain frequency and output impedance in addition to lower power dissipation. And also, a current-mode third-order lowpass active filter was designed with the proposed current-mode integrator. The designed circuits were fabricated using the ORBIT's 1.2.mu.m double-poly double-metal CMOS n-well process. The experimental resutls of the active filter designed and fabricated for this research have shown that it has the performance of 44.5MHz cutoff frequency, 3.3mW power dissipation and the third-order active filter area was 0.12mm$^{2}$.

  • PDF

A Consideration of the PWM Cycloconverter with a Resonant Circuit for Induction Heating (공진회로를 이용한 유도가열용 PWM 사이크로콘버터에 대한 고찰)

  • Kim, Hyun-Jung;Kim, Young-Seok
    • Proceedings of the KIEE Conference
    • /
    • 1994.07a
    • /
    • pp.509-511
    • /
    • 1994
  • Cycloconverters can be classified into two types by the main circuit configuration. One is the non- circulating current type required the dead time the other is circulating current type which has the circulating current reactors. The switching devices were highly stressed by the load voltages during dead time on non-circulating current type operation and the circulating currents on circulating current type operation. The overcome those problems, this paper proposes the switching patterns for the partial and the non circulation current type. The PWM methods, which are saw wave comparing method and load current integrating value comparing method, are presented.

  • PDF

A Study on the Numerical Models of Wave induced Currents (파랑에 의한 연안류의 수치모델에 관한 연구)

  • Lee, Jung-Maan;Kim, Jae-Joong;Park, Jung-Chul
    • Journal of Ocean Engineering and Technology
    • /
    • v.12 no.3 s.29
    • /
    • pp.75-85
    • /
    • 1998
  • A finite difference model for predicting time-dependent, wave-induced nearshore current is studied. The model includes wave refraction, wave-current interaction, bottom friction and wind effect. This model iteratively solved the linear the linear set of conservation of both mass and momentum, which were time averaged (over one wave period) and depth integrated, for mean velocities and free surface displacement. Numerical simulations of nearshore current under oblique wave attack, and for wave and wind induced current on a longshore periodic beach are carried out. Longshore velocities tend to zero in some distances outside the breaker line. And the peak velocity is shifted shoreward at the breaker line. The results represent the general characteristics of the nearshore current induced by wave.

  • PDF

Current limiting characteristics of transformer type SFCL with coupled secondary windings according to its winding direction

  • Han, Tae Hee;Lim, Sung Hun
    • Progress in Superconductivity and Cryogenics
    • /
    • v.19 no.2
    • /
    • pp.44-47
    • /
    • 2017
  • In this paper, the current limiting characteristics of the transformer type superconducting fault current limiter (SFCL) with the two coupled secondary windings due to its winding direction were analyzed. To analyze the dependence of transient fault current limiting characteristics on the winding direction of the additional secondary winding, the fault current limiting tests of the SFCL with an additional secondary winding, wound as subtractive polarity winding and additive polarity winding, were carried out. The time interval of quench occurrence between two superconducting elements comprising the transformer type SFCL with the additional secondary winding was confirmed to be affected by the winding direction of the additional secondary winding. In case of the subtractive polarity winding of the additional secondary winding, the time interval of the quench occurrence in two superconducting elements was shorter than the case of the additive polarity winding.

Modeling of a Converter Utilizing Current Mode Control (전류모드제어 방식을 이용하는 컨버터의 모델링)

  • 정영석;이준영;강정일;윤명중
    • Proceedings of the KIPE Conference
    • /
    • 1998.07a
    • /
    • pp.275-278
    • /
    • 1998
  • The mathematical interpretation of a practical sampler which is useful to obtain the small signal models for the peak and average current mode controls is proposed. Due to the difficulties in applying the Shannon's sampling theorem to the analysis of sampling effects embedded in the current mode control, several different approaches have been reported. However, these approaches require the information of the inductor current in a discrete expression, which restricts the application of the reported method only to the peak current mode control. In this paper, the mathematical expressions of sampling effects on a current loop which can directly apply the Shannon's sampling theorem are newly proposed, and applied to the modeling of the peak current mode control. By the newly derived models of a practical sampler, the models in a discrete time domain and a continuous time domain are obtained. It is expected that the derived models are useful for the control loop design of power supplies. The effectiveness of the derived models are verified through the simulation and experimental results.

  • PDF

The characteristic research of a Bi-2223 wires by the Various Transport Current (수송전류에 따른 Bi-2223 선재의 특성연구)

  • 오정훈;배덕권;강형구;안민철;이상진;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.02a
    • /
    • pp.220-223
    • /
    • 2003
  • High-Tc superconducting(HT S) systems are commercialized by many study on high-Tc superconductor. For the successful commercialization of superconducting systems using Bi-2223 wires, the database on the degradation of critical current is essentially needed. In this paper, critical current variation of Bi-2223 wires according to the transport time was investigated. The degradation rate of critical current was also calculated. Solenoid type specimens have the length of 190cm Bi-2223 wire and double-pancake type specimens have the length of l0m wire were tested. Tested Bi-2223 wires are commercialized products of AMSC (American Superconductor) and Innost. When the transportation current was 95% of critical current, the degradation of critical current was appeared after 5 hours of transport time.

  • PDF

A 3V-50MHz analog CMOS continuous time current-mode filter with a negative resistance load

  • 현재섭;윤광섭
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.21 no.7
    • /
    • pp.1726-1733
    • /
    • 1996
  • A 3V-50MHz analog CMOS continuous-time current-mode filter with a negative resistance load(NRL) is proposed. In order to design a current-mode current integrator, a modified basic current mirror with a NRL to increase the output resistance is employed. the inherent circuit structure of the designed NRL current integrator, which minimizes the internal circuit nodes and enhances the gain bandwidth product, is capable of making the filter operate at the high frequency. The third order Butterworth low pass filter utilizing the designed NRL current integrator is synthesized and simulated with a 1.5.mu.m CMOS n-well proess. Simulation result shows the cutoff frequency of 50MHz and power consumption of 2.4mW/pole with a 3V power supply.

  • PDF

Distance relay using the current transformer compensating algorithm (변류기 보상 알고리즘을 적용한 거리계전기)

  • Kang, Yong-Cheol;Lee, Hyun-Woong;Jang, Sung-Il;Kim, Yong-Kyun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.501-502
    • /
    • 2007
  • This paper describes a distance relay that operates in conjunction with a current transformer (CT) compensation algorithm. A distance relay detects a fault based on the ratio of the voltage to the current. If a CT saturates, the calculated impedance becomes larger. This causes maloperation or operating time delay of the distance relay. A compensating algorithm estimates the correct secondary current from the severely distorted currents even when the measurement CTs are used. The correct current is estimated by adding the calculated magnetizing current to the measured secondary current. Test results show that the proposed distance relay can detect a fault without the operating time delay even when the secondary currents are extremely distorted because of use of measurement CTs.

  • PDF