• Title/Summary/Keyword: time elapsed

Search Result 941, Processing Time 0.032 seconds

Fluidity and Hydration Properties of Cement Paste Added Zinc Fluosilicate(ZnSiF6, aq.) (규불화아연(ZnSiF6, aq)이 첨가된 시멘트의 유동성과 수화특성)

  • Kim, Do-Su;Khil, Bae-Su;Lim, Heon-Seong;Nam, Jae-Hyun;Rho, Jae-Seong
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.2
    • /
    • pp.178-183
    • /
    • 2002
  • Zinc fluosilicate ($ZnSiF_6$, 15% aqueous solution) was prepared using zinc oxide (ZnO) and fluosilicic acid ($H_2SiF_6$) by soluiton synthetic method. The fluidity and hydration properties of cement which was added $ZnSiF_6$ (aq.) as an additive for cement were studied. At water to cement ratio (W/C) equals to 0.45, the initial fluidity and slump loss of cement paste which the addition of $ZnSiF_6$ (aq.) was increased from 1.0% to 4.0% based on cement weight were investigated. Initial fluidity of cement paste was measured by mini-slump test and slump loss was examined by measuring the fluidity variation of cement paste with time elapsed from 0 min to 120 min at intervals 30 min. Also, the effect of $ZnSiF_6$ addition on the setting and hydration of cement paste when $ZnSiF_6$ increased in the addition range 1.0% to 3.0% were investigated. The fluidity of cement paste which was added 2.1% $ZnSiF_6$ (aq.) presented the highest value among all addition ranges. The setting time of cement paste was retarded gradually and the heat evolution of hydrated cement was reduced with the increasing of $ZnSiF_6$ addition.

COMPARATIVE STUDY ON BODY TEMPERATURE CHANCE OF NEWBORN INFANTS IN GENERAL CRIB AND ELECTRIC-HEAT CRIB (일반침대와 가온침대에 있는 신생아의 체온변화에 관한 비교연구)

  • 박영숙
    • Journal of Korean Academy of Nursing
    • /
    • v.4 no.1
    • /
    • pp.95-106
    • /
    • 1974
  • The Purpose of this study was to observe the body temperature changes of newborn infants in general crib and electric heat crib after birth for the period required to reach the optimum body temperature. Forty-seven newborn infants who were delivered at Seoul National University Hospital during the period from June 12 to September 13, 1973 were chosen as Subjects for this study. The criteria for the choice of subjects were the babies with normal spontaneous delivery; body weight 2.5kg and over at birth; Apgar so ore seven and over and gestation period over thirty-six weeks. Of these subjects, by random sampling thirty-one newborn infants were placed in the general crib and sixteen in the electric-heat crib. The rectal body temperature of these newborn infants were taken and recorded at fifteen-minute interval for the first one hour period after birth, at thirty minute interval for the next two hours and at one hour interval for the remaining period up to eight hours. The results of the study were as follows: 1. The mean body temperature of the newborn infants on admission to nursery ranged from 98.7℉. to 99℉. irrespective of the body weight and the room temperature. 2. There was a significant difference in the body temperature changes of the newborn infants as a total between the general crib and the electric-heat crib from three to eight hours after birth. It was found that the body temperature of the newborn infants in the electric-heat crib was significantly higher than that of the newborn infants in the general crib. 3. In comparison with the body temperature changes of the newborn infants in the general crib, the newborn infants in the electric- heat crib exhibited significantly higher body temperatures in all three body weight groups; from four to eight hours after birth in the 2.5-2.9kg body weight group; from three to seven hours after birth in the 3.0-3.4kg body weight group; from two and half to six hours after birth in the group with body weight over 3.5kg. 4. Time required to reach 98℉. of body temperature was four hours in the 3.5-2.9kg body weight group, three hours in the 3.0-3.4kg. body weight group and two and half hours in the group with body weight over 3.5kg in the electric- heat crib. In the general crib, it took over eight hours in the 2.5-2.9kg body weight group and five hors in both the 3.0-3.4kg and over 3.5kg body weight group to reach 98℉ of body temperature. 5. The lowest mean body temperature of newborn infants in both general and electric- heat crib appeared in forty-five minute after birth and the temperature ranged from 96.4℉ to 96.5℉. 6. The mean body temperature of the newborn infants in the general crib was increased as the room temperature. 7. The body weight, the room temperature and the time elapsed after birth fore proved to be significant factors influencing the body temperature changes of newborn infants. From tile above results, the three hypotheses were positively accepted.

  • PDF

Analysis of Exposure Pathways and the Relative Importance of Radionuclides to Radiation Exposure in the Case of a Severe Accident of a Nuclear Power Plant (원전 중대사고시 피폭경로 및 핵종의 방사선 피폭에 대한 상대적 중요도 해석)

  • Hwang, Won-Tae;Suh, Kyung-Suk;Kim, Eun-Han;Han, Moon-Hee;Kim, Byung-Woo
    • Journal of Radiation Protection and Research
    • /
    • v.19 no.3
    • /
    • pp.209-221
    • /
    • 1994
  • In the case of a severe accident of a nuclear power plant, the whole body dose and the relative importance of the radionuclides during the lifetime of an exposed person were estimated for each exposure pathway with distances from the release point. The external exposure pathways due to immersion of radioactive cloud and deposition of radioactive materials on the ground, and the internal exposure pathways due to inhalation and ingestion of contaminated foodstuffs were considered. The effects due to the ingestion of contaminated foodstuffs were estimated considering the variation of radioactive concentration in the foodstuffs according to deposition time and elapsed time after deposition using a dynamic ingestion pathway model applicable to Korean environment, named 'KORFOOD'. As the results up to 80 km from the release point, the effects due to ingestion of contaminated foodstuffs showed the highest contribution to total exposure dose. The contribution of I isotopes was the highest in the case of the external dose due to immersion of radioactive cloud and internal dose due to inhalation. The contribution of Cs isotopes was highest in the case of the external dose due to deposition of radioactive materials on the ground. In the case of the internal dose due to ingestion of contaminated foodstuffs, Cs deposition in summer and Sr deposition in winter, respectively, were the most dominant radionuclide to whole body.

  • PDF

Effects of Ammonia Exposure on Survival Rate and Hematological Characteristics Changes in Juveniles of Sevenband Grouper, Epinephelus septemfasciatus (능성어 (Epinephelus septemfasciatus) 치어의 생존율과 혈액학적 특성 변화에 미치는 암모니아 노출의 영향)

  • Kim, Jung Hyun;Park, Jong Youn;Lee, Jeong Yong;Lee, Jin Hwan;Hwang, Hyung Kyu;Cho, Jae Kwon
    • Korean Journal of Ichthyology
    • /
    • v.29 no.1
    • /
    • pp.13-21
    • /
    • 2017
  • We investigated that changes of survival rate and hematological factors in sevenband grouper (Epinephelus septemfasciatus), exposed to ammonia. First, the fish was exposed and was observed survival rate. We observed the survival rate of the fish when exposed at each ammonia concentrations (0, 0.35, 0.4, 0.5, 0.8 mg/L, $NH_3$) for 96 hours. The 96-h $LC_{50}$ (lethal ambient concentration for 50% of the population) of $NH_4^+$ and un-ionized ammonia ($NH_3$) for sevenband grouper were 26.7 and 0.6 mg/L, respectively. Secondly, we exposed the fish to 96-h $LC_{50}$ ammonia concentration (0.6 mg/L) for 96 hours, then sampled the blood of groupers for analysis of cortisol, glucose, $NH_3$, GOT, GPT, total protein (TP), electrolytes ($Na^+$, $Cl^-$) and osmolality in plasma. The plasma cortisol, glucose, GOT and GPT were increased with increasing of elapsed time and ammonia concentration. In addition, the $NH_3$ and total protein in plasma were significantly increased to 12 hours exposed to ammonia, and then decreased. But, the values were significantly higher than the control. The plasma electrolytes ($Na^+$, $Cl^-$) and osmolality were decreased with increasing of elasped time. The results in the present study suggest that the continuous exposure of ammonia to juveniles of sevenband grouper may be a stressor and negative influence.

Influence and Application of an External Variable Magnetic Field on the Aqueous HCl Solution Behavior: Experimental Study and Modelling Using the Taguchi Method (염산 수용액 거동에 대한 가변 외부 자기장의 적용과 영향: 실험 연구 및 Taguchi 법을 이용한 모델링)

  • Hashemizadeh, Abbas;Ameri, Mohammad Javad;Aminshahidy, Babak;Gholizadeh, Mostafa
    • Applied Chemistry for Engineering
    • /
    • v.29 no.2
    • /
    • pp.215-224
    • /
    • 2018
  • Influences of the magnetic field on 5, 10 and 15 wt% (1.5, 3 and 4.5 M) HCl solution behaviour, which has widespread applications in petroleum well acidizing, were investigated in various conditions. Differences in the pH of magnetized hydrochloric acid compared to that of normal hydrochloric acid were measured. Taguchi design of experimental (DoE) method were used to model effects of the magnetic field intensity, concentration, velocity and temperature of acid in addition to the elapsed time. The experimental results showed that the magnetic field decreases [$H^+$] concentration of hydrochloric acid up to 42% after magnetization. Increasing the magnetic field intensity (with 28% contribution), concentration (with 42% contribution), and velocity of acid increases the effect of magnetic treatment. The results also demonstrated that the acid magnetization was-not influenced by the fluid velocity and heating. It was also displayed that the acid preserves its magnetic memory during time. The optimum combination of factors with respect to the highest change of [$H^+$] concentration was obtained as an acid concentration of 10% and an applied magnetic field of 4,300 Gauss. Due to the reduction of HCl reaction rate under the magnetization process, it can be proposed that the magnetized HCl is a cost effective and reliable alternative retarder in the matrix acidizing of hydrocarbon (crude oil and natural gas) wells.

Preparation and Characterization of Ferrite Supported on Porous Ceramic Fiber Composites for Co2 Decomposition (이산화탄소 분해용 페라이트 담지 다공성 세라믹 섬유복합체 제조와 물성)

  • Lee, Bong-Soo;Kim, Myung-Soo;Choi, Seung-Chul;Oh, Jae-Hee;Lee, Jae-Chun
    • Journal of the Korean Ceramic Society
    • /
    • v.39 no.8
    • /
    • pp.801-806
    • /
    • 2002
  • The decomposition and/or conversion of carbon dioxide to carbon have been studied using oxygen-deficient ferrites for the reduction of $CO_2$ emission to the atmosphere. In this work, the homogeneous precipitation method using urea decomposition was employed to induce in situ precipitation of Ni ferrite($Ni_{0.4}Fe_{2.6}O_4$) on the porous ceramic fiber support (50 mm diameter${\times}$10 mm thickness). Effects of ferrite loading conditions on the CO2 decomposition efficiency were discussed in this paper. Removal of residual chloride ions and urea by solvent exchange from the porous media after ferrite deposition apparently helps to form spinel ferrite, but does not increase the efficiency of $CO_2$ decomposition. Porous ceramic fiber composites containing 20 wt% (1g) ferrite samples showed 100% efficiency for $CO_2$decomposition during the first three minutes, but the efficiency decreased rapidly after the elapsed time of ten minutes. The characteristic reduction time for the $CO_2$ decomposition efficiency was estimated as about 3∼7 min.

Marginal Bone Resorption Analysis of Dental Implant Patients by Applying Pattern Recognition Algorithm (패턴인식 알고리즘을 적용한 임플란트 주변골 흡수 분석)

  • Jung, Min Gi;Kim, Soung Min;Kim, Myung Joo;Lee, Jong Ho;Myoung, Hoon;Kim, Myung Jin
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • v.35 no.3
    • /
    • pp.167-173
    • /
    • 2013
  • Purpose: The aim of this study is to analyze the series of panoramic radiograph of implant patients using the system to measure peri-implant crestal bone loss according to the elapsed time from fixture installation time to more than three years. Methods: Choose 10 patients having 45 implant fixtures installed, which have series of panoramic radiograph in the period to be analyzed by the system. Then, calculated the crestal bone depth and statistics and selected the implant in concerned by clicking the implant of image shown on the monitor by the implemented pattern recognition system. Then, the system recognized the x, y coordination of the implant and peri-implant alveolar crest, and calculated the distance between the approximated line of implant fixture and alveolar crest. By applying pattern recognition to periodic panoramic radiographs, we attained the results and made a comparison with the results of preceded articles concerning peri-implant marginal bone loss. Analyzing peri-implant crestal bone loss in a regression analysis periodic filmed panoramic radiograph, logarithmic approximation had highest $R^2$ value, and the equation is as shown below. $y=0.245Logx{\pm}0.42$, $R^2=0.53$, unit: month (x), mm (y) Results: Panoramic radiograph is a more wide-scoped view compared with the periapical radiograph in the same resolution. Therefore, there was not enough information in the radiograph in local area. Anterior portion of many radiographs was out of the focal trough and blurred precluding the accurate recognition by the system, and many implants were overlapped with the adjacent structures, in which the alveolar crest was impossible to find. Conclusion: Considering the earlier objective and error, we expect better results from an analysis of periapical radiograph than panoramic radiograph. Implementing additional function, we expect high extensibility of pattern recognition system as a diagnostic tool to evaluate implant-bone integration, calculate length from fixture to inferior alveolar nerve, and from fixture to base of the maxillary sinus.

Development of techniques for evaluating residual life of water pipes based on pipe deterioration evaluation results (관로 노후도 평가결과를 이용한 상수도 관로의 잔존수명 평가 기법의 개발)

  • Park, Suwan;Kim, Kimin
    • Journal of Korea Water Resources Association
    • /
    • v.50 no.10
    • /
    • pp.673-679
    • /
    • 2017
  • In this paper a method for estimating the 'service life' and 'residual life' of a water pipe based on the Water Pipe Network Performance Evaluation(WPNPE) results of Water Supply Technical Diagnosis was developed for efficient maintenance of water pipes. The residual life of a pipe was defined as the difference between the service life and elapsed time since installation. The service life was defined as the time when a pipe reaches the reference score for determining deteriorated pipes that was used in the WPNPE. The pipe evaluation criteria and deterioration scores used in the WPNPE for the case study area were considered as independent variables in the multiple regression model for estimating the service life and residual life of the pipes in the area. To estimate the service life for the pipes the reference scores for determining deteriorated pipes were used as the values of the variables that represent the deterioration scores in the constructed regression models. Subsequently, the statistics of the service life and residual life of the pipes in the case study area were presented and analyzed in comparison with the service life defined by the Local Public Enterprizes Act.

Effect of Reducing the Odor of Food Wastes Using Effective Microorganism (EM) (유용미생물을 활용한 음식물쓰레기의 악취저감 효과)

  • Kim, Ha-Na;Yim, Bongbeen;Kim, Sun-Tae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.4
    • /
    • pp.162-168
    • /
    • 2016
  • The aim was to investigate the effect of reducing the odorous and complex odor released during the decomposition of food wastes using effective microorganism (EM) as a function of time at $20^{\circ}C$ and $35^{\circ}C$. The variation of total microbial counts and dominant species counts in EM and leachate produced during food wastes decomposition was also observed. In general, the cumulative concentration of sulfur compounds ($H_2S$, $CH_3SH$) and complex odor released during food wastes decomposition increased with increasing elapsed time. The nitrogen compounds ($NH_3$, trimethyl amine), however, was not observed in all samples. The addition of EM in food wastes resulted in the reduction of concentration of sulfur compounds and complex odor, in spite of the increase of $CH_3CHO$ concentration. The dominant microbial species detected in EM were Lactobacillus species(Lactobacillus rhamnosus and Lactobacillus casei). In the leachate produced during food wastes decomposition, however, the various microbial community alternative to that detected in EM was observed. The EM could be potentially useful as a tools for reducing odor induced from the food waste decomposition process.

A Study on the Feasibility of the Timing for the Implementation of Energy-Saving Plan of Buildings Based on the Approval of Business Plan and Construction Permit (건축물에너지절약계획서의 사업계획승인, 건축허가에 따른 적용시점의 타당성 연구)

  • Kim, Dae-Won;Kim, Young-Il;Chung, Kwang-Seop
    • Journal of Energy Engineering
    • /
    • v.21 no.3
    • /
    • pp.265-270
    • /
    • 2012
  • The delay in the construction permit for the building, which obtained the approval of business proposal, may lead to a difference in the maintenance cost ranging between 20% and 30% in the neighborhood where the residents moved in, along with the new project under construction in the surrounding area amidst rigorous regulations that aim to promote energy-saving and the heightened interest of the public in energy conservation, and such problem would become the major source of serious public complaints. Thus, the energy-saving plan needs to be prepared when the approval is granted to the business plan. In order to prevent public complaints or ensure effectiveness of government's energy plan, it may be effective to apply the energy-saving plan based on current standards upon the award of construction permit when two years have elapsed since the date of the scheduled commencement of construction or when the start of construction is delayed as stipulated in the Article 18 of the Enforcement Decree of Housing Act. If the energy-saving plan and related technologies are merely the parts of license and permit process without fully serving their purposes and functions, it would be waste of time to deploy a lot of workforce and review and seek consultation. The government or owners of buildings need to fully understand the energy-saving aspects and exert effort to enhance the energy efficiency of buildings.