검색결과 462건 처리시간 0.027초

뇌방전에 의한 유도전압의 측정에 대한 기초적 연구 (A Basic Study on the Measurement Induced Voltages due to Lightning Discharges)

  • 이복희;조성철;엄주홍;이우철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2004년도 춘계학술대회 논문집
    • /
    • pp.559-564
    • /
    • 2004
  • This paper deals with the device for measuring the time-varying magnetic fields and induced voltages caused by lightning discharges. The two magnetic field measuring systems were designed and made. One consists of the loop-type magnetic field sensor with the active integrator operated by a differential amplifier. The other consists of the loop-type magnetic field sensor and Labview software. The loop-type magnetic field sensor detects the time derivative of the magnetic field being measured, and the signal detected is integrated by the Labview software. As a consequence, from the calibration experiments, the frequency bandwidth of the full measuring system ranges from 400 [Hz] to 1 (MHz) and the response sensitivity are 0.98 (mV/nT) and 22 (mV/nT) for the magnetic field sensor of 2 turns and 6 turns, respectively. Also, the results obtained by the two measuring devices well agreed with each other.

  • PDF

Linearized Transistor Model Based Automated Biasing Scheme for Analog Integrated Circuits

  • Lacek, Matthew;Nahra, Daniel;Roter, Ben;Lee, Kye-Shin
    • Journal of Multimedia Information System
    • /
    • 제8권2호
    • /
    • pp.143-146
    • /
    • 2021
  • This work presents an automated transistor biasing scheme for analog integrated circuits. In order to effectively bias the transistor at a desired operating point, the proposed method uses a linearized transistor circuit model along with the curve fitted expressions obtained from the pre-simulated I-V characteristics of the actual transistor. As a result, the transistor size that leads to the desired operating point can be easily determined without heavily relying on the circuit simulator, which will lead to significant design time reduction. Furthermore, the proposed method is applied to an actual amplifier circuit where the design time based on the proposed biasing method showed 10× faster than the conventional design approach using the circuit simulator.

음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 시간-인코딩 된 근적외선 흡광도 측정 비교 연구 (Time-encoded Near-infrared (NIR) Spectroscopic Comparison of Absorbance Measurement Using an Acousto-optic NIR Swept Laser Source)

  • 장한솔;김경훈;한가희;조재두;김창석
    • 한국광학회지
    • /
    • 제28권1호
    • /
    • pp.22-27
    • /
    • 2017
  • 본 논문에서는 음향광학 파장선택 필터(acousto-optic tunable filter) 기반의 파장훑음 레이저(wavelength swept laser)를 이용한 시간-인코딩 근적외선 분광 기술(time-encoded near-infrared spectroscopy)을 제안하였다. 파장훑음 레이저는 800 nm 근처 영역에서 이득 스펙트럼을 가지는 반도체 광 증폭기(semiconductor optical amplifier)를 기반으로 제작되었으며, 음향광학 파장선택 필터를 공진기 내부에 삽입함으로써 음향광학 파장선택 필터에 인가되는 전기적 라디오주파수에 따라 출력 파장을 선택할 수 있도록 하였다. 본 연구에서는 종래의 기술인 백색광 분광기 기반의 검출부 분광 근적외선 분광 기술과 제안된 파장훑음 레이저 기반의 광원부 분광 근적외선 분광 기술을 각각 이용하여 근적외선 흡수 염료 샘플의 흡광도를 각기 측정하여 실험적으로 비교함으로써 본 연구에서 제안하는 음향광학 파장선택 필터 기반 파장훑음 레이저를 이용한 근적외선 분광 기술의 특성을 증명하였다.

어군에 의한 광대역 음향산란신호의 시간-주파수 분석을 위한 chirp 데이터 수록 및 처리 시스템의 성능특성 (Performance Characteristics of a Chirp Data Acquisition and Processing System for the Time-frequency Analysis of Broadband Acoustic Scattering Signals from Fish Schools)

  • 이대재
    • 한국수산과학회지
    • /
    • 제51권2호
    • /
    • pp.178-186
    • /
    • 2018
  • A chirp-echo data acquisition and processing system was developed for use as a simplified, PC-based chirp echo-sounder with some data processing software modules. The design of the software and hardware system was implemented via a field-programmable gate array (FPGA). Digital signal processing algorithms for driving a single-channel chirp transmitter and dual-channel receivers with independent TVG (time varied gain) amplifier modules were incorporated into the FPGA for better real-time performance. The chirp-echo data acquisition and processing system consisted of a notebook PC, an FPGA board, and chirp sonar transmitter and receiver modules, which were constructed using three chirp transducers operating over a frequency range of 35-210 kHz. The functionality of this PC-based chirp echo-sounder was tested in various field experiments. The results of these experiments showed that the developed PC-based chirp echo-sounder could be used in the acquisition, processing and analysis of broadband acoustic echoes related to fish species identification.

산업용 전기차량의 주행 모터용 보상된 Bang-Bang 전류제어기 개발 (The Development of Compensated Bang-Bang Current Controller for Travel Motor of Industry Electrical Vechicle)

  • 천영신;정영일;배종일;이만형
    • 한국정밀공학회지
    • /
    • 제16권9호
    • /
    • pp.34-40
    • /
    • 1999
  • In order to establish the design technique of the robust current controller in d.c series wound motor driver system, this paper proposes a method of the compensated Bang-Bang current control using d.c series wound motor driver system under the improperly variable load to get minimum time for the torque control. The compensated Bang-Bang current controller structure is simpler than that of PID plus Bang-Bang controller. This paper shows that a general 16 bits microprocessor is efficiently used to implement such an algorithm. The calculation time of software is extremely small when compared with that of conventional PID plus Bang-Bang controller. Both nonlinear operating characteristics of digital switching elements and describing function methods are used for the analysis and synthesis. Real-time implementation of the compensated Bang-Bang current controller is achieved. The concept of design strategy of the control and the PWM waveform generation algorithms are presented in this paper.

  • PDF

Minimum detectable activity of plastic scintillator for in-situ beta measurement system in ground water

  • Choi, Woo Nyun;Lee, UkJae;Bae, Jun Woo;Kim, Hee Reyoung
    • Nuclear Engineering and Technology
    • /
    • 제51권4호
    • /
    • pp.1169-1175
    • /
    • 2019
  • The minimum detectable activity (MDA) value was derived according to the flow rate of the sample and degree of amplification of the device by sending the sample directly from the collection site to the detection part through a pump. This method can lead to reduction in time and cost compared to the existing measurement method that uses a pre-treatment process. In this study, experiments were conducted on $^3H$ and $^{90}Sr$, which are the major pure beta-emitting radionuclides, by setting the sample flow rate and the amplification gain as factors. The MDA values were derived according to the flow rates, considering that the flow rate can affect the MDA values. There were no change in the MDA under different flow rates of 0, 600, 800, and 1000 mL/min. Therefore, it was confirmed that the flow rate may not be considered when collecting samples for monitoring in actual field. As the degree of amplification of the amplifier increased, the time required to reach the target MDA decreased. When the amplification was quadrupled, the detection efficiency increased by approximately 23.4 times, and the time to reach the MDA decreased to approximately 1/550 times. This method offers the advantage of real-time on-site monitoring.

Push-Pull Detection 구조 및 빠른 응답 특성을 갖는 LDO 레귤레이터 (LDO Regulator with Improved Fast Response Characteristics and Push-Pull Detection Structure)

  • 이주영
    • 전기전자학회논문지
    • /
    • 제25권1호
    • /
    • pp.201-205
    • /
    • 2021
  • 본 논문에서는 push-pull 감지 회로 구조로 인해 load transient 특성을 개선시킨 LDO를 제안하였다. LDO 레귤레이터 패스 트랜지스터의 입력단과 내부 오차증폭기의 출력단 사이에 제안된 push-pull 감지 회로 구조로 인한 전압 델타 값의 응답 특성을 개선시켜 종래의 LDO 레귤레이터보다 load transient 특성에서 우수한 효과를 가진다. 기존의 LDO 레귤레이터보다 rising time에서는 약 244 ns, falling time에서는 약 90 ns 만큼의 향상된 응답속도를 가진다. 제안된 회로는 Cadence사의 Spectre, Virtuoso 시뮬레이션 tool을 사용하여 samsung 0.13um 공정으로 특성 및 결과를 시뮬레이션 하였다.

마이크로프로세서를 이용한 병원용 환자 링거액 잔류유량 원격 실시간 검사 시스템 개발 (Development of a Remote Monitoring System of the Residual Amount of Ringer's Solution at Hospitals Using a Microprocessor)

  • 하관용;권종원;오드게렐;김희식
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 학술대회 논문집 정보 및 제어부문
    • /
    • pp.279-282
    • /
    • 2005
  • A real-time measurement and control system was developed, This system is used for nurses at hospitals to check the residual quantity and changing time of Ringer's solution in nurses' room. Load Cell is utilized as a sensor to check the residual quantity of Ringer's solution, This Load Cell detects the physical changes of Ringer's solution and transfers electronic signal to the amplifier. Amplified analog signal is converted into digital signal by NO converter. Developed Embedded system, which computes these data with microprocess(8052) then makes it possible to monitor the residual quantity of Ringer's solution real-time on a server computer. A Checking system on Residual Quantity of Ringer's Solution Using Load cell cut costs using a simple design for a circuit

  • PDF

2차원 CCD를 이용한 복사기 렌즈의 실시간 MTF 측정 (Real time MTF Measurement of Copy Lenses by two-dimensional CCDs)

  • 조현모;이윤우;이인원;김태희;최옥식;이환규
    • 한국광학회지
    • /
    • 제7권1호
    • /
    • pp.1-8
    • /
    • 1996
  • 렌즈의 실시간 성능축정을 위하여 MTF측정장치에 CCD를 많이 사용하고 있다. 본 연구에서는 2차원 CCD를 복사기 렌즈의 실시간 MFT측정장치에 사용했을 때 CCD에 의한 각종 MTF특성을 분석하였다. CCD로 측정한 복사기 렌즈의 MTF는 2차원 CCD의 shift register가 배열된 방향과 셔터 속도, 광신호 증폭회로의 증폭률에 따라 다른 특성을 나타내었다. 광원의 밝기에 의한 MTF 값의 변화를 줄이기 위하여 축상면 및 비축상면에서 복사조도가 균일한 광원장치를 제작하였으며 MTF 값이 측정된 표준렌즈를 사용하여 복사기 렌즈용 실시간 MTF측정장치를 교정하였다.

  • PDF

단열배관의 온라인 두께측정시스템 개발 (Development of Real Time On-Line Thickness Measuring System for Insulated Pipeline)

  • 장지훈;김병주;조경식;김기동
    • 연구논문집
    • /
    • 통권32호
    • /
    • pp.65-76
    • /
    • 2002
  • The intensity of x-ray or gamma-ray is attenuated according to density and thickness of the transmitted medium. In this study, by using this principle, on-line real-time radiometric system was developed using a 128 channels linear array of solid state detectors to measure wall thickness of insulated piping system. This system uses a Ir-192 as a gamma ray source and detector is composed of BGO scintillator and photodiode. Ir-192 gamma ray source and linear detector array mounted on a computer controlled robotic crawler. The Ir-192 gamma ray source is located on one side of the piping components and the detector array on the other side. The individual detectors of the detector array measure the intensity of the gamma rays after passing through the walls and the insulation of the piping component under measurement. The output of the detector array is amplified by amplifier and transmitted to the computer. This system collects and analyses the data from the detector array in real-time. The maximum measurable length of pipe is 120cm/mm. in the case of 1mm scanning interval.

  • PDF