• Title/Summary/Keyword: tibiae

Search Result 58, Processing Time 0.028 seconds

Removal Torque of Mg-ion Implanted Clinical Implants with Plasma Source Ion Implantation Method (마그네슘 이온주입 임플란트의 뒤틀림 제거력에 관한 연구)

  • Kim, Bo-Hyoun;Kim, Dae-Gon;Park, Chan-Jin;Cho, Lee-Ra
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.25 no.1
    • /
    • pp.41-52
    • /
    • 2009
  • The surface treatment of titanium implant could bring out the biochemical bonding between bone and implant. The purpose of this study was to evaluate the biomechanical bone response of Mg-ion implanted implants with plasma source ion implantation method. Twelve New Zealand white rabbits were included in this study. Each rabbit received one control fixture (blasted with resorbable blasting media, RBM) and three types of Mg ion implanted fixtures in tibiae. The implants were left in place for 6 weeks before the rabbits were sacrificed. Removal torque value and resonance frequency analysis (ISQ) were compared. The repeated measured analysis of variance was used with $P{\leq}0.05$ as level of statistical significance. ISQ was not different among all groups. However, the ISQ was increased after 6 weeks healing. The group had lowest ISQ value showed the greatest increment. Mg-1 implants with 9.4% retained ion dose showed significantly higher removal torque value than that of the other implants. From this results, it is concluded that the Mg-1 implants has stronger bone response than control RBM surface implant.

On the effect of saline immersion to the removal torque for resorbable blasting media and acid treated implants (Resorbable blasting media 및 산처리한 임플란트의 제거회전력에 생리식염수를 적시는 것이 미치는 영향)

  • Kwon, Jae-uk;Cho, Sung-am
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.1-9
    • /
    • 2018
  • Purpose: The purpose of this study is to investigate the effect of the titanium implant soaked in saline after RBM and acid etched surface treatment on the initial osseointegration by comparing the removal torque and the surface analysis compared to the titanium implant with only RBM and acid etched surface treatment. Materials and Methods: The control group was RBM and acid etched surface treated implants (RBM + HCl), and the test group was implants soaked in saline for 2 weeks after RBM and acid etched surface treatment (RBM + HCl + Sal). The control and test group implants were placed in the left and right tibiae of 10 rabbits, respectively, and at the same time, the insertion torque (ITQ) was measured. After 10 days, the removal torque (RTQ) was measured by exposing the implant site. FE-SEM, EDS, Surface roughness and Raman spectroscopy were performed for the surface analysis of the new implant specimens used in the experiments. Results: There was significant difference in insertion torque and removal torque between control group and experimental group (P = 0.014 < 0.05). Surface roughness of experimental group is higher than control group. Conclusion: Saline soaking after RBM and acid etched surface treatment of titanium implants were positively affect the initial osseointegration as compared to titanium implants with only RBM and acid etched surface treatment.

Comparison Between Ultrasonic and X-ray Methods for Imaging the Children′s Growth Plate (어린이 성장판 영상화를 위한 초음파와 X-선 방식의 비교 평가)

  • Kim Sang Hoo;Kim Hyung Jun;Han Eun Ok;Han Seung Moo
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.6
    • /
    • pp.551-556
    • /
    • 2004
  • The purpose of this study was to suggest a systematic and scientific method for measurement of children's growth development, in which the accuracy of existing diagnosis method has not been concretely examined yet. The most popular method for diagnosis of children's growth is to analyze the opening degree of growth plate in each joint by X-ray image. However, X-ray method has some disadvantages; it is impossible to measure the diagnosis of growth periodically and repeatedly due to the radiation problem. Hence, this study introduced a profile analysis and the algorithm of analyzing the image of growth plate with the BUA(Broadband Ultrasound Attenuation) of calcaneus, to verify the possibility of alternative ultrasonic method harmless to human body. We obtained the images of growth plate in proximal tibiae, phalanges, and calcanei of 269 children (7∼16 years old) with X-ray. And the image of growth plate in calcanei was also obtained front those children with ultrasound. The results showed that the time of the opening degree of growth plate in each joint was almost consistent between X-ray and ultrasonic images. Also, the images of growth plate measured by X-ray and ultrasound showed the high correlation. Therefore, it is expected that the algorithm of ultrasonic profile analysis introduced in this study can replace the existing X-ray method to measure the growth plate correctly.

The Effect of Genetically Modified Lactobacillus plantarum Carrying Bone Morphogenetic Protein 2 Gene on an Ovariectomized Rat

  • Jin, Eun-Sun;Kim, Ji Yeon;Yang, Jung-Mo;Kim, Jun-Sub;Min, JoongKee;Jeon, Sang Ryong;Choi, Kyoung Hyo;Moon, Gi-Seong;Jeong, Je Hoon
    • Journal of Korean Neurosurgical Society
    • /
    • v.65 no.2
    • /
    • pp.204-214
    • /
    • 2022
  • Objective : Osteoporosis result from age-related decline in the number of osteoblast progenitors in the bone marrow. Probiotics have beneficial effects on the host, when administered in appropriate amounts. This study investigated the effects of probiotics expressing specific genes, especially the effects of genetically modified bone morphogenetic protein (BMP)-2-expressing Lactobacillus plantarum CJNU 3003 (LP) on ovariectomized rats. Methods : Twenty-eight female Wistar rats (250-300 g, 12 weeks old) were divided into four groups : the sham (control), the ovariectomy (OVX)-induced osteoporosis group (OVX), the OVX and LP (OVX/LP), OVX and genetically modified BMP-2-expressing LP (OVX/LP with BMP) groups. The three groups underwent bilateral OVX and two of these groups were administered two different types of LP via oral gavage daily. At 16 weeks post-OVX, blood was collected from the heart and the bilateral tibiae were extracted and were scanned by ex-vivo micro-computed tomography and stained with hematoxylin-and-eosin (H&E) and Masson's trichrome stain for pathological assessment. The serum levels of osteocalcin (OC), rat C-telopeptide of type I collagen (CTX-I), BMP-2, and receptor activator of nuclear factor-ĸB ligand (RANKL) were measured. Results : The 3D-micro-computed tomography images showed that the trabecular structure in the OVX/LP with BMP group was maintained compared with OVX and OVX/LP groups. No significant differences were detected in trabecular thickness (Tb.Th) between control and OVX/LP with BMP groups (p>0.05). Furthermore, a tendency toward increased BMD, trabecular bone volume, Tb.Th, and trabecular number and decreased trabecular separation was found in rats in the OVX/LP with BMP groups when compared with the OVX and OVX/LP groups (p>0.05). The H&E and Masson's trichrome stained sections showed a thicker trabecular bone in the OVX/LP with BMP group compared with the OVX and OVX/LP groups. There was no difference in serum levels of OC, CTX and RANKL control and OVX/LP with BMP groups (p>0.05). In contrast, significant differences were found in OC and CTX-1 levels between the OVX and OVX/LP with BMP groups (p<0.05). Conclusion : Our results showed that the expression of genetically modified BMP-2 showed inhibition effect for bone loss in a rat model of osteoporosis.

Multicentric Epithelioid Angiosarcoma of Bones Showing Angiotropic Spread: A Case Report (뼈에 발생한 혈관성 파종 양상을 보이는 다발성 상피상 혈관육종: 증례 보고)

  • Woo Suk Choi;Seul Ki Lee;Jee-Young Kim;Jun-Ho Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.85 no.1
    • /
    • pp.240-246
    • /
    • 2024
  • Epithelioid angiosarcoma is a rare variant of angiosarcoma characterized by an epithelioid morphology that mimics carcinoma. Therefore, multicentric epithelioid angiosarcoma is easily misdiagnosed as bone metastasis from carcinoma and has an aggressive clinical course. Here, we present a rare case of a 61-year-old male with multicentric epithelioid angiosarcoma of the bone. Plain radiography, CT, and MRI revealed multiple osteolytic lesions in both femurs; some lesions showed soft tissue extension with cortical bone destruction. Interestingly, PET-CT revealed that the lesions were only distributed along the bones of the lower extremities, including the pelvic bones, femurs, and tibiae. Despite histological analysis initially suggesting metastatic carcinoma, after additional immunohistological staining, including that for vascular markers (CD31 and ERG), the final diagnosis was epithelioid angiosarcoma. A better understanding of the clinicoradiological features of this disease may help eliminate diagnostic confusion and provide better management.

Histomorphometric study of machined titanium implants and calcium phosphate coated titanium implants (Machined 티타늄 임플란트와 calcium phosphate coated 티타늄 임플란트의 조직형태계측학적 연구)

  • Kang, Hyun-Joo;Yang, Jae-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.48 no.2
    • /
    • pp.122-127
    • /
    • 2010
  • Purpose: The objective of this study was to investigate the effects of calcium phosphate coated titanium implant surface on bone response and implant stability at early stage of healing period of 3 weeks and later healing period of 6 weeks. Material and methods: A total of 24 machined, screw-shaped implants (Dentium Co., Ltd., Seoul, Korea) which dimensions were 3.3 mm in diameter and 5.0 mm in length, were used in this research. All implants (n = 24), made of commercially pure (grade IV) titanium, were divided into 2 groups. Twelve implants (n = 12) were machined without any surface modification (control). The test implants (n = 12) were anodized and coated with thin film (150nm) of calcium phosphate by electron-beam deposition. The implants were placed on the proximal surface of the rabbit tibiae. The bone to implant contact (BIC) ratios was evaluated after 3 and 6 weeks of implant insertion. Results: The BIC percentage of calcium phosphate coated implants ($70.8{\pm}18.9%$) was significantly higher than that of machined implants ($44.1{\pm}16.5%$) 3 weeks after implant insertion (P = 0.0264). However, there was no significant difference between the groups after 6 weeks of healing (P > .05). Conclusion: The histomorphometric evaluation of implant surface revealed that; 1. After 3 weeks early healing period, bone to implant contact (BIC) percentage of calcium phosphate coated implants (70.8%) was much greater than that of surface untreated machined implants (44.1%) with P = 0.0264. 2. After 6 weeks healing period, however, BIC percentage of calcium phosphate coated implants group (79.0%) was similar to the machined only implant group (78.6%). There was no statistical difference between two groups (P = 0.8074). 3. We found the significant deference between the control group and experimental group during the early healing period of 3 weeks. But no statistical difference was found between two groups during the later of 6 weeks.

A STUDY ON THE MEASUREMENT OF THE IMPLANT STABILITY USING RESONANCE FREQUENCY ANALYSIS (공진 주파수 분석법에 의한 임플랜트의 안정성 측정에 관한 연구)

  • Park Cheol;Lim Ju-Hwan;Cho In-Ho;Lim Heon-Song
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.41 no.2
    • /
    • pp.182-206
    • /
    • 2003
  • Statement of problem : Successful osseointegration of endosseous threaded implants is dependent on many factors. These may include the surface characteristics and gross geometry of implants, the quality and quantity of bone where implants are placed, and the magnitude and direction of stress in functional occlusion. Therefore clinical quantitative measurement of primary stability at placement and functional state of implant may play a role in prediction of possible clinical symptoms and the renovation of implant geometry, types and surface characteristic according to each patients conditions. Ultimately, it may increase success rate of implants. Purpose : Many available non-invasive techniques used for the clinical measurement of implant stability and osseointegration include percussion, radiography, the $Periotest^{(R)}$, Dental Fine $Tester^{(R)}$ and so on. There is, however, relatively little research undertaken to standardize quantitative measurement of stability of implant and osseointegration due to the various clinical applications performed by each individual operator. Therefore, in order to develop non-invasive experimental method to measure stability of implant quantitatively, the resonance frequency analyzer to measure the natural frequency of specific substance was developed in the procedure of this study. Material & method : To test the stability of the resonance frequency analyzer developed in this study, following methods and materials were used : 1) In-vitro study: the implant was placed in both epoxy resin of which physical properties are similar to the bone stiffness of human and fresh cow rib bone specimen. Then the resonance frequency values of them were measured and analyzed. In an attempt to test the reliability of the data gathered with the resonance frequency analyzer, comparative analysis with the data from the Periotest was conducted. 2) In-vivo study: the implants were inserted into the tibiae of 10 New Zealand rabbits and the resonance frequency value of them with connected abutments at healing time are measured immediately after insertion and gauged every 4 weeks for 16 weeks. Results : Results from these studies were such as follows : The same length implants placed in Hot Melt showed the repetitive resonance frequency values. As the length of abutment increased, the resonance frequency value changed significantly (p<0.01). As the thickness of transducer increased in order of 0.5, 1.0 and 2.0 mm, the resonance frequency value significantly increased (p<0.05). The implants placed in PL-2 and epoxy resin with different exposure degree resulted in the increase of resonance frequency value as the exposure degree of implants and the length of abutment decreased. In comparative experiment based on physical properties, as the thickness of transducer increased, the resonance frequency value increased significantly(p<0.01). As the stiffness of substances where implants were placed increased, and the effective length of implants decreased, the resonance frequencies value increased significantly (p<0.05). In the experiment with cow rib bone specimen, the increase of the length of abutment resulted in significant difference between the results from resonance frequency analyzer and the $Periotest^{(R)}$. There was no difference with significant meaning in the comparison based on the direction of measurement between the resonance frequency value and the $Periotest^{(R)}$ value (p<0.05). In-vivo experiment resulted in repetitive patternes of resonance frequency. As the time elapsed, the resonance frequency value increased significantly with the exception of 4th and 8th week (p<0.05). Conclusion : The development of resonance frequency analyzer is an attempt to standardize the quantitative measurement of stability of implant and osseointegration and compensate for the reliability of data from other non-invasive measuring devices It is considered that further research is needed to improve the efficiency of clinical application of resonance frequency analyzer. In addition, further investigation is warranted on the standardized quantitative analysis of the stability of implant.

Migration of $^{99m}Tc$-Hexamethylpropylene Amino Oxime (HMPAO) Labeled Immature and Mature Dendritic Cells in the Mouse (마우스에서 Tc-99m HMPAO 표지 미성숙 및 성숙 수지상세포의 이동에 관한 연구)

  • Li, Ming-Hao;Lee, Je-Jung;Min, Jung-Joon;Heo, Young-Jun;Song, Ho-Chun;Park, Young-Kyu;Park, An-Na;Bom, Hee-Seung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.39 no.1
    • /
    • pp.26-33
    • /
    • 2005
  • Purpose: The purpose of this study is to evaluate migration of technetium-99m hexamethylpropylene amine oxime ($^{99m}Tc$-HMPAO) labeled immature and mature dendritic cells (DC) in the mouse. Methods: DC were collected from bone marrow (BM) of tibiae and femurs of mice. Immature and mature DC from BM cells were radiolabeled with $^{99m}Tc$-HMPAO. To evaluate the functional and phenotypic changes of DC from radiolabeling, the allogeneic mixed lymphocyte reaction (MLR) and fluorescence-activated cell sorting (FACS) analysis were performed before and after labeling with $^{99m}Tc$-HMPAO. Migration of intravenously injected DC (iv-DC) was assessed by serial gamma camera images of mice with or without subcutaneous tumor. Percent injected dose per gram (%ID/g) was calculated in lungs, liver, spleen, kidneys, and tumor through dissection of each mice after 24 hours of injection. Results: Labeling efficiency of immature and mature DC were $60.4{\pm}5.4%\;and\;61.8{\pm}6.7%$, respectively. Iv-DC initially appeared in the lungs, then redistributed mainly to liver and spleen. Migration of mature DC to spleen was significantly higher than that of immature DC ($38.3{\pm}4.0%\;vs.\;32.2{\pm}4.1%$ in control group, $40.4{\pm}4.1%\;vs.\;35.9{\pm}3.8%$ in tumor group; p<0.05). Migration to tumor was also significantly higher in mature DC than in immature DC ($2.4{\pm}0.3%\;vs\;1.7{\pm}0.2%$; p=0.034). Conclusion: Assessment of migration pattern of DC in mice was possible using $^{99m}Tc$-HMPAO labeled immature and mature DC. Migration of mature DC to spleen and tumor was higher than that of immature DC when they were i.v. injected.