• Title/Summary/Keyword: threshold values

Search Result 977, Processing Time 0.024 seconds

ST Segment Shape Classification Algorithm for Making Diagnosis of Myocardial Ischemia (심근허혈 진단을 위한 ST세그먼트 형태 분류 알고리즘)

  • Cho, Ik-Sung;Kwon, Hyeog-Soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.15 no.10
    • /
    • pp.2223-2230
    • /
    • 2011
  • ECG is used to diagnose heart diseases such as myocardial ischemia, arrhythmia and myocardial infarction. Particularly, myocardial ischemia causes the shape change of the ST segment, this change is transient and may occur without symptoms. So it is important to detect the transient change of ST segment through long term monitoring. ST segment classification algorithm for making diagnosis myocardial ischemia is presented in this paper. The first step in the ST segment shape classification process is to detect R wave point and feature points based adaptive threshold and window. And then, the suggested algorithm detects the ST level change, To classify the ST segment shape, the suggested algorithm uses the slope values of the four points between the S and T wave. The ECG data in the European ST-T database were used to verify the performance of the developed algorithm. The best correct rate was 99.40% and the worst correct rate was 68.48%.

Quality of Breast Cancer Early Detection Services Conducted by Well Woman Clinics in the District of Gampaha, Sri Lanka

  • Vithana, Palatiyana Vithanage Sajeewanie Chiranthika;Ariyaratne, M.A.Y.;Jayawardana, P.L.
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.14 no.1
    • /
    • pp.75-80
    • /
    • 2013
  • Background: Breast cancer is the most common cancer diagnosed in females in Sri Lanka and early detection can lead to reduction in morbidity and mortality. Aim: To evaluate selected aspects of breast cancer early detection services implemented through well woman clinics (WWCs) in the Gampaha District. Methods: The study consisted of two components. A retrospective descriptive arm assessed clinical breast examination (CBE) coverage of target age group women (TGW) of 35-59 years in all the WWCs in Gampaha district over 2003-2007. A cross sectional descriptive study additionally assessed quality of breast cancer early detection services. The Lot Quality Assurance Sampling (LQAS) technique was used to decide on the lot size and threshold values, which were computed as twenty and six clinics. Checklists were employed in assessing coverage, physical facilities and clinic activities. Client satisfaction on WWC services was assessed among 200 TGW attending 20 WWCs using an interviewer-administered questionnaire. Results: CBE coverage in the Gampaha district increased only from 1.1-2.2% over 2003-2007. With regard to physical facilities, the number of clinics that were rated substandard varied between 7-18 (35-90%). The items that were lacking included dust bins, notice boards, stationary, furniture and linen, and cleanliness of outside premises and toilets. With regard to clinic activities, punctuality of staff, late commencement of clinics, provision of health education, supervision, CBE and breast self-examination (BSE) were substandard in 7-20 clinics (35-100%). Client satisfaction for WWC services was 45.2% (IQR: 38.7-54.8%) and only 11% had a score of ${\geq}70%$, the cut off set for satisfaction. Conclusions: Breast cancer early detection service coverage in the Gampaha district remained low (2.2%) in 2007, 11 years after commencing WWCs. All 20 clinics were substandard for overall CBE and BSE.

Feature-Oriented Adaptive Motion Analysis For Recognizing Facial Expression (특징점 기반의 적응적 얼굴 움직임 분석을 통한 표정 인식)

  • Noh, Sung-Kyu;Park, Han-Hoon;Shin, Hong-Chang;Jin, Yoon-Jong;Park, Jong-Il
    • 한국HCI학회:학술대회논문집
    • /
    • 2007.02a
    • /
    • pp.667-674
    • /
    • 2007
  • Facial expressions provide significant clues about one's emotional state; however, it always has been a great challenge for machine to recognize facial expressions effectively and reliably. In this paper, we report a method of feature-based adaptive motion energy analysis for recognizing facial expression. Our method optimizes the information gain heuristics of ID3 tree and introduces new approaches on (1) facial feature representation, (2) facial feature extraction, and (3) facial feature classification. We use minimal reasonable facial features, suggested by the information gain heuristics of ID3 tree, to represent the geometric face model. For the feature extraction, our method proceeds as follows. Features are first detected and then carefully "selected." Feature "selection" is finding the features with high variability for differentiating features with high variability from the ones with low variability, to effectively estimate the feature's motion pattern. For each facial feature, motion analysis is performed adaptively. That is, each facial feature's motion pattern (from the neutral face to the expressed face) is estimated based on its variability. After the feature extraction is done, the facial expression is classified using the ID3 tree (which is built from the 1728 possible facial expressions) and the test images from the JAFFE database. The proposed method excels and overcomes the problems aroused by previous methods. First of all, it is simple but effective. Our method effectively and reliably estimates the expressive facial features by differentiating features with high variability from the ones with low variability. Second, it is fast by avoiding complicated or time-consuming computations. Rather, it exploits few selected expressive features' motion energy values (acquired from intensity-based threshold). Lastly, our method gives reliable recognition rates with overall recognition rate of 77%. The effectiveness of the proposed method will be demonstrated from the experimental results.

  • PDF

Quantitative measurement of peri-implant bone defects using optical coherence tomography

  • Kim, Sulhee;Kang, Se-Ryong;Park, Hee-Jung;Kim, Bome;Kim, Tae-Il;Yi, Won-Jin
    • Journal of Periodontal and Implant Science
    • /
    • v.48 no.2
    • /
    • pp.84-91
    • /
    • 2018
  • Purpose: The purpose of this study was to visualize and identify peri-implant bone defects in optical coherence tomography (OCT) images and to obtain quantitative measurements of the defect depth. Methods: Dehiscence defects were intentionally formed in porcine mandibles and implants were simultaneously placed without flap elevation. Only the threads of the fixture could be seen at the bone defect site in the OCT images, so the depth of the peri-implant bone defect could be measured through the length of the visible threads. To analyze the reliability of the OCT measurements, the flaps were elevated and the depth of the dehiscence defects was measured with a digital caliper. Results: The average defect depth measured by a digital caliper was $4.88{\pm}1.28mm$, and the corresponding OCT measurement was $5.11{\pm}1.33mm$. Very thin bone areas that were sufficiently transparent in the coronal portion were penetrated by the optical beam in OCT imaging and regarded as bone loss. The intraclass correlation coefficient between the 2 methods was high, with a 95% confidence interval (CI) close to 1. In the Bland-Altman analysis, most measured values were within the threshold of the 95% CI, suggesting close agreement of the OCT measurements with the caliper measurements. Conclusions: OCT images can be used to visualize the peri-implant bone level and to identify bone defects. The potential of quantitative non-invasive measurements of the amount of bone loss was also confirmed.

Evaluation of Air Contaminants Concentrations and Ventilation Systems in Governmental Agency and University Laboratories (국내 정부출연연구기관 및 대학교 실험실 공기 오염물질 농도 및 환기시스템 평가)

  • Ha, Ju-Hyun;Shin, Yong-Chul;Lee, Hyun-Seok;Paik, Samuel Y.;Yi, Gwang-Yong;Lee, Byeong-Ku
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.20 no.1
    • /
    • pp.63-69
    • /
    • 2010
  • This study was conducted to compare the concentration of various air contaminants in nine different laboratories during routine activities. Volatile organic compounds (VOC) were sampled and analyzed using NIOSH Method 1500 and asbestos fibers were sampled and analyzed using NIOSH Method 9002 and 7400. Detectable levels of acetone, toluene and ethanol were found in all the laboratories and xylene and n-hexane were detected in eight of the nine laboratories. All the VOC concentrations were well below the Korean Ministry of Labor's Exposure Limit and American Conference of Governmental Industrial Hygienists' (ACGIH) Threshold Limit Values (TLVs). Total VOC concentrations at the university laboratories were significantly higher than those at governmental agency laboratories. Airborne fiber concentrations were below 0.01 fibers/cc, while the concentration of chrysotile was 2% in insulation materials sprayed on the ceiling of one laboratory. While all the governmental agency laboratories (n=4) had fume hoods, two out of the five university laboratories did not have fume hoods. The capture velocity of half of the fume hoods were below the maintenance standard(0.4 m/sec). In conclusion, the study suggests that the current controls in place at both university and government agency laboratories are not sufficient in limiting exposure to harmful chemicals to non-detectable levels, though they appear to be adequate in protecting workers to levels below applicable occupational exposure limits. The study also suggests that researchers working in university laboratories may be exposed to greater levels of contaminant than those working in government agency laboratories.

Segmentation and 3-Dimensional Reconstruction of Liver using MeVisLab (MeVisLab을 이용한 간 영역 분할 및 3차원 재구성)

  • Shin, Min-Jun;Kim, Do-Yeon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.16 no.8
    • /
    • pp.1765-1772
    • /
    • 2012
  • Success rate of transplantation of body organs improved due to development of medical equipment and diagnostic technology. In particular, a liver transplant due to liver dysfunction has increased. With the development of image processing and analysis to obtain the volume for liver transplantation have increased the accuracy and efficiency. In this thesis, we try to reconstruct the regions of the liver within three dimensional images using the mevislab tool, which is effective in quick comparison and analysis of various algorithms, and in expedient development of prototypes. Liver is divided by applying threshold values and region growing method to the original image, and by removing noise and unnecessary entities through morphology and region filling, and setting of areas of interest. It is deemed that high temporal efficiency, and presentation of diverse range of comparison and analysis module application methods through usage of MeVisLab would make contribution towards expanding of baseline of medical image processing researches.

Inter-cell DCA Algorithm for Downlink Wireless Communication Systems (하향링크 무선 통신 시스템에서의 Inter-cell DCA 알고리즘)

  • Kim, Hyo-Su;Kim, Dong-Hoi;Park, Seung-Young
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.33 no.7A
    • /
    • pp.693-701
    • /
    • 2008
  • In OFDMA (Orthogonal Frequency Division Multiple Access) system that frequency reuse factor is 1, as the same channels in the neighborhood cells creates inter-cell co-channel interference which provides a resource underutilization problem, channel allocation schemes to minimize inter-cell interference have been studied. This paper proposes a new CNIR (Carrier to Noise and Interference Ratio)-based distributed Inter-cell DCA (Dynamic Channel Allocation) algorithm in the OFDMA environment with frequency reuse factor of 1. When a channel allocation is requested, if there is not a free channel in home cell or the available free channels in home cell do not satisfy a required threshold value, the proposed Inter-cell DCA algorithm finds CNIR values of available free channels in the neighborhood cells and then allocates a free channel with maximum CNIR value. Through the simulation results, we find that the proposed scheme decreases both new call block rate and forced termination rate due to new call generation at the same time because it increases channel allocation probability.

Degradation Mechanism of single grain boundary in Zno Varistor (ZnO 바리스터 단입계의 열화 메카니즘)

  • Kim, Jong-Ho;Lim, Keun-Young;Kim, Jin-Sa;Park, Choon-Bae
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2004.07b
    • /
    • pp.784-789
    • /
    • 2004
  • Bulk ZnO varistor based on Matsuoka, which varied $SiO_2$ addition has fabricated by standard ceramic process. The micro-electrode, which fabricated for investigation on degradation property of the Single Grain Boundary of ZnO varistor, has sticked by lithography semiconductor process. The values of AC degradation has measured with 150% operating voltage in varistor threshold with 120 minute in 60Hz. In here we observed V-I and V-C property in every 30minute. The operating voltage of Single Grain Boundary has shown in variable patterns in the characteristic of V-I Property. By increasing the $SiO_2$ contents, operating value has also increased and dominated on degradation proper. In EPMA analysis, we know that added $SiO_2$ was nearly distributed at the Grain Boundary. $SiO_2$ has gradually distributed in Grain Boundary condition during the process of crystal growth. It contributes to degradation depression and decision of operating voltage. We also demonstrated for using practical application and performance on distribution random loop based on V-I Properties in Single-Grain-Boundary.

  • PDF

Voice Recognition Performance Improvement using the Convergence of Voice signal Feature and Silence Feature Normalization in Cepstrum Feature Distribution (음성 신호 특징과 셉스트럽 특징 분포에서 묵음 특징 정규화를 융합한 음성 인식 성능 향상)

  • Hwang, Jae-Cheon
    • Journal of the Korea Convergence Society
    • /
    • v.8 no.5
    • /
    • pp.13-17
    • /
    • 2017
  • Existing Speech feature extracting method in speech Signal, there are incorrect recognition rates due to incorrect speech which is not clear threshold value. In this article, the modeling method for improving speech recognition performance that combines the feature extraction for speech and silence characteristics normalized to the non-speech. The proposed method is minimized the noise affect, and speech recognition model are convergence of speech signal feature extraction to each speech frame and the silence feature normalization. Also, this method create the original speech signal with energy spectrum similar to entropy, therefore speech noise effects are to receive less of the noise. the performance values are improved in signal to noise ration by the silence feature normalization. We fixed speech and non speech classification standard value in cepstrum For th Performance analysis of the method presented in this paper is showed by comparing the results with CHMM HMM, the recognition rate was improved 2.7%p in the speech dependent and advanced 0.7%p in the speech independent.

Implementation of G.726 ADPCM Dual Rate Speech Codec of 16Kbps and 40Kbps (16Kbps와 40Kbps의 Dual Rate G.726 ADPCM 음성 codec구현)

  • Kim Jae-Oh;Han Kyong-Ho
    • Journal of IKEEE
    • /
    • v.2 no.2 s.3
    • /
    • pp.233-238
    • /
    • 1998
  • In this paper, the implementation of dual rate ADPCM using G.726 16Kbps and 40Kbps speech codec algorithm is handled. For small signals, the low rate 16Kbps coding algorithm shows almost the same SNR as the high rate 40Kbps coding algorithm , while the high rate 40Kbps coding algorithm shows the higher SNR than the low rate 16Kbps coding algorithm fur large signal. To obtain the good trade-off between the data rate and synthesized speech quality, we applied low rate 16Kbps for the small signal and high rate 40Kbps for the large signal. Various threshold values determining the rate are applied for good trade-off between data rate and speech quality. The simulation result shows the good speech quality at a low rate comparing with 16Kbps & 40Kbps.

  • PDF