• Title/Summary/Keyword: threshold methods

Search Result 1,483, Processing Time 0.034 seconds

The Effects of Myofascial Release on Pain Threshold and Sympathetic Hyperactivity in Patients with Adhesive Capsulitis: Case Study (근막이완술이 유착성 관절낭염 환자의 통증 역치와 교감신경계 과활동에 미치는 효과: 사례연구)

  • Jeong, Seong-gwan;Lee, Ho-jun
    • The Journal of Korean Academy of Orthopedic Manual Physical Therapy
    • /
    • v.27 no.2
    • /
    • pp.87-92
    • /
    • 2021
  • Purpose: This study aimed to investigate the effects of myofascial release technique on pain threshold and hormonal changes in patients with adhesive capsulitis of the shoulder. Methods: Eight patients with adhesive capsulitis were treated with the myofascial release technique. Myofascial release is a form of manual therapy that involves the application of a low load, long duration stretch to the myofascial complex, intended to restore optimal length, decrease pain, and improve function. Blood tests and pressure pain threshold (PPT) examinations were performed on their first visit. On their second visit, the myofascial release technique was applied to the shoulder for 20 min. Then, blood tests and PPT were re-evaluated to determine the effects of the myofascial release technique on pain threshold and hormonal changes. Results: Pain threshold increased from 2.92 to 24.13 lb after treatment. Epinephrine decreased from .13 to .08 ng/mL whereas norepinephrine increased from .25 to .41ng/㎖ after treatment. Conclusion: Myofascial release technique in patients with adhesive capsulitis increased pain thresholds, norepinephrine and decreased epinephrine levels.

Verification of the Appropriateness of the Standard for Tunnel Luminance in the Threshold Zone Through a Full-scale Tunnel Driving Test (실 규모 터널 주행실험을 통한 터널 경계부 휘도 기준의 적정성 검증)

  • Park, Won Il;Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.17 no.6
    • /
    • pp.105-115
    • /
    • 2015
  • PURPOSES : This study aimed to evaluate the appropriateness of safety with the standard for threshold zone luminance as specified in the Recommendation for Lighting of Traffic Tunnel, which has been widely adopted worldwide. METHODS : A driving test of the subject in a full-scale road tunnel was conducted. The adaptation luminance and threshold zone luminance, which should be known for the driver to perceive an object within stopping sight distance, were obtained. These values were compared with the adaptation luminance and threshold zone luminance obtained by the existing reduced model test and tunnel lighting standard that has served as a guideline for the current threshold zone luminance standard. RESULTS : According to this study, threshold zone luminance should be increased to at least 1.8 times the value proposed in the existing studies and to twice the domestic tunnel lighting standard (KS C 3703: 2014). CONCLUSIONS : The threshold zone luminance proposed in this study differs largely from that obtained from indoor tests and from the current tunnel lighting standard used worldwide; this difference may be attributed to the fact that the indoor tests did not incorporate driving workload, non-uniformity of luminance distribution in terms of sight, and factors that reduce the visibility of the driver, such as the light reflected into the driver's eyes. Hence, it is necessary to further review the factors that reduce the visibility of drivers approaching tunnels in order to determine the rational tunnel threshold zone luminance.

Relationship between Adaptation Luminance and Threshold Zone Luminance for Vehicular Traffic Tunnels (터널 순응휘도와 경계부 휘도의 관계 연구)

  • Cho, Won Bum;Jeong, Jun Hwa
    • International Journal of Highway Engineering
    • /
    • v.16 no.3
    • /
    • pp.85-99
    • /
    • 2014
  • PURPOSES : This study has been performed with the objective to determine threshold zone luminance of adaptation luminance by target safety level in a vehicular traffic tunnel with design speed set at 100km/h. METHODS : The study made a miniature capable of portraying changes in luminance distribution within $2{\times}10^{\circ}$ conical field of view of the driver approaching to the tunnel for the test. Test conditions were set based on justifications for CIE 88-1990's threshold zone luminance used as a reference by domestic tunnel light standards (KS C 3703 : 2010). Luminance contrast of object background and object is 23%, object presentation duration is 0.5 seconds, and size of the object background is $7.3{\times}11.5m^2$ RESULTS : Threshold zone luminance was set within adaptation luminance of $100{\sim}3,000cd/m^2$. Adaptation luminance and threshold zone luminance based on 50%, 75% and 90% target safety level all showed a relatively high linear relationship. According to findings in the study, it is not appropriate to specify the relationship between adaptation luminance and threshold zone luminance as luminance ratio. Rather, direct utilization of the linear relationship gained from the study findings appears to be the better solution. CONCLUSIONS : Findings of this study may be used to determine operation of threshold zone luminance based on target safety level. However, a proper verification and validity of test results are required. Furthermore, a study to determine proper threshold zone luminance level considering target safety level reviewed in this study and various decision-making factors such as economic conditions in Korea and energy-related policies should be carried out in addition. Additional tests on adaptation luminance greater than $3,000cd/m^2$ will be performed, through which application scope of the test findings will be broadened.

Correlation between the Pressure Pain Threshold and Sonography and Spontaneous Electrical Activity in Myofascial Trigger Points

  • Kim, Hyun-Jin;Kim, Myung-Hoon;Kim, Su-Hyon;Oh, Seok;Choi, Ji-Ho;Kim, Tae-Youl
    • The Journal of Korean Physical Therapy
    • /
    • v.22 no.3
    • /
    • pp.17-21
    • /
    • 2010
  • Purpose: This study was designed to investigate possibilities for quantitative analysis using the electromyography and sonography. For better understanding, we evaluated the correlation between the pressure pain threshold and sonography, spontaneous electrical activity in trigger points located in the upper trapezius muscle. Methods: Thirty three active subjects volunteered to participate in this study (n=33). They had a palpable taut band, exquisite spot tenderness of a nodule in a taut band, spontaneous pain, referred pain, jump sign, local twitch response, and a painful limit to full stretch range of motion. We measured Pressure pain threshold, density, white area index, root mean square, and reaction. Pearson’s correlation coefficient was calculated to estimate the relationship between the pressure pain threshold and other variables including density, white area index, root mean square, and reaction time. Results: There were significant correlations between pressure pain threshold and density (r=-0.75, p<0.01), and between pressure pain threshold and white area index (r=-0.74, p<0.01). A significant correlations between pressure pain threshold and root mean square (r=-0.59, p<0.01). The significant correlation was found between pressure pain threshold and reaction time (r=-0.64, p<0.01). Conclusion: These should indicate whether quantitative analysis can be done using the characteristics of electromyography and sonography.

Gender Differences in Heat Pain and Temporal Summation Threshold in Normal Volunteers (정상 자원자에서 열통증과 시간적 가중 역치에 대한 남녀 차이)

  • Lee, Joon Ho;Yoo, Jae Hwa;Cho, Sung Hwan;Kim, Yong Ik
    • The Korean Journal of Pain
    • /
    • v.21 no.2
    • /
    • pp.126-130
    • /
    • 2008
  • Background: Females generally have a lower pain and temporal summation threshold than men. However, the results of studies designed to evaluate gender differences in the thresholds of heat pain and the temporal summation have been inconsistent. Newly developed device, CHEPS (Contact Heat Evoked Potential Stimulation) model of PATHWAY, have superiority on its fast rise and return time in temperature. Therefore we investigated gender differences in heat pain and temporal summation threshold. Methods: Forty healthy volunteers (20 males and 20 females) were enrolled in this study. A thermode was applied to the volar side of each volunteer's left forearm and heat pain and the temporal summation threshold was then measured. The heat pain threshold was estimated using the staircase method by starting from $36^{\circ}C$ and then increasing the temperature in $0.5^{\circ}C$ increments. The temporal summation threshold was estimated by applying five successive stimulation of the same temperature starting at $2^{\circ}C$ lower than the heat pain threshold and then increasing the temperature in $0.5^{\circ}C$ increments. Results: The mean heat pain thresholds was found to be $41.63{\pm}1.63^{\circ}C$ for males and $41.60{\pm}1.84^{\circ}C$ for females and the temporal summation thresholds were found to be $40.83{\pm}1.64^{\circ}C$ for males and $40.77{\pm}1.93^{\circ}C$ for females. The differences between males and females were not statistically significant. Conclusions: The result of this study suggested that there are no gender differences in heat pain and temporal summation threshold.

Effects of Magnetic Therapy to Improve on Pain Threshold, Blood Flow, and Balance in Patient with Knee Osteoarthritis (자기장 치료법이 무릎 뼈관절염 환자의 통증 역치, 혈류량 및 균형능력에 미치는 영향)

  • Kyong-Hun Kim;Dong-Hoon Kim
    • Journal of The Korean Society of Integrative Medicine
    • /
    • v.11 no.3
    • /
    • pp.127-135
    • /
    • 2023
  • Purpose : This study was performed to evaluate the effects of magnetic therapy (MT) on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Methods : A single-blind, randomized controlled trial (RCT) was conducted with 30 patient with knee osteoarthritis. They were randomly allocated 2 groups; magnetic therapy group (MTG; n=15) and placebo magnetic therapy group (PG; n=15). The MTG group received 30 minutes magnetic therapy and 20 minute conservative physical therapy (Hotpack, ICT), magnetic therapy was conducted in magnetic therapy device (OM-100, NUGA, Korea). In the placebo magnetic group received 30 minutes placebo magnetic therapy and 20 minute conservative physical therapy. Each group performed 50 minutes a day 3 times a week for 8 weeks. The primary outcome pressure pain threshold test, blood flow, balance ability were measured by a pressure threshold meter (Commander algometer, JTECH medical, USA), laser dofler image (Moor LDI2-IR, Moor instruments, USA), balance measurement system (BioRescue, Marseille, France). The measurement were performed before and after the 8 weeks intervention period. Results : Both groups demonstrated significant improvement of outcome in pain threshold, blood flow, and balance ability during intervention period. magnetic therapy group revealed significant differences in pain threshold, blood flow, and balance as compared to the placebo magnetic therapy group groups (p<.05). Our results showed that magnetic therapy was more effective than placebo therapy on pain threshold, blood flow, and balance in patients with knee osteoarthritis. Conclusion : Our findings indicate that magnetic therapy can improve pain threshold, blood flow, and Balance, highlight the benefits of magnetic therapy. This study will be able to be used as an intervention data for recovering pain threshold, blood flow, and balance in patients with knee osteoarthritis.

JPEG Image Quantization Method with Variable Thresholds (가변 임계값을 갖는 JPEG 영상의 양자화 방법)

  • 윤석현
    • Journal of the Korea Society of Computer and Information
    • /
    • v.8 no.2
    • /
    • pp.24-30
    • /
    • 2003
  • In this Paper VTQM(Variable Threshold quantization Method) is proposed, which enhances PSNR by composing the advantages of round-off and truncation quantization methods. From vast experiments, PSNR's of JPEG images with the method are compared with that of standard JPEG methods. At the boundary which affects the compression ratio, VTQM quantizes with a new threshold to reduce the length of compressed data; otherwise, VTQM employs the round-off quantization method to preserve the original image information. As a result, VTQM reduces bit rate while preserving the image quality. The experimental results show that VTQM enhances PSNR by 0.2∼0.3dB, 0.4∼0.5dB with the same bit rate than those of the traditional truncation and round-off quantization methods, respectively.

  • PDF

The Development of Automatic Correction Algorithm for the Knocking Threshold in Spark Ignition Engine (스파크 점화기관에서의 노킹판단 기준값의 자동수정 알고리즘 개발)

  • 강성현;장광수;서정인;전광민
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.7 no.7
    • /
    • pp.32-41
    • /
    • 1999
  • In this study, a new knocking control algorithm was developed using the knock threshold value auto-correction algorithm. This algorithm uses the Fast Fourier Transform9FFT) method by measuring cylinder block vibration signals of a 1498 cc four-cylinder spark ignition engine. The experimental results show the proposed knock control algorithm provides improved performance compared to existing methods. The results also show that the proposed FFT algorithm provides real-time adjustment of the knock threshold value.

  • PDF

Denoising Algorithm using Wavelet (웨이브렛을 이용한 잡음 제거 알고리즘)

  • 배상범;김남호
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.6 no.8
    • /
    • pp.1139-1145
    • /
    • 2002
  • Wavelet transformed data can filter signal with each frequency band, because it includes detail information about original signal. Therefore, in this paper, important two noises were removed by wavelet. About AWGN environment UDWT(undecimated discrete wavelet transform), applying hard-threshold, was used and about impulse noise environment, it can be possible to recognize edge of original signal as well as superior denoising effect by using two methods, denoising by threshold and slope of signal by wavelet. SNR was used as a judgemental criterion of a denoising effect and Blocks and DTMF(dual tone multi frequency) were used as a test signal.

Implementation of Image Thinning using Threshold Neural Network (선형 신경 회로망을 이용한 영상 Thinning구현)

  • 박병준;이정훈
    • Journal of the Korean Institute of Intelligent Systems
    • /
    • v.10 no.4
    • /
    • pp.310-314
    • /
    • 2000
  • This paper proposes a new parallel architecture for extracting the object from binarized images using recurrent linear threshold neural networks. Binary functions are initially obtained from the existing iterative thinning algorithms, and the linear threshold neural threshold neural networks are then synthesized using the MSP term grouping algorithm. Experimental results show that the proposed architectures can be implemented easier than with other existing methods.

  • PDF