• 제목/요약/키워드: thin-sample

검색결과 711건 처리시간 0.028초

Hydrogen Absorption and Electronic Property Change of Yttrium Thin Films

  • Cho, Young-Sin
    • 한국수소및신에너지학회논문집
    • /
    • 제7권1호
    • /
    • pp.71-79
    • /
    • 1996
  • Yttrium thin film, 580nm thick, was prepared by electron beam evaporation. Film was hydrogenated room temperature upto 40 bar hydrogen pressure, without any activation process. Hydrogen concentration was determined by a quartz-crystal microbalance(QCM) method. YH2.9 sample was made without any pulverization. Electrical resistance was measured by four-point DC method in the temperature range between room temperature and 30K for various hydrogen concentration, x=0 to 2.9 of YHx sample. Temperature dependent resistance of YH2.9 shows low temperature minimum at 105K, the metal-semiconductor transition at 260K, and a hystersis above 210K.

  • PDF

Langumir-Blodgett법으로 제작된 polyimide 超薄膜(초박막)의 전기적특성(電氣的特性) (A study on the Electric Characteristics of Polyimide Ultra Thin through LB-Method)

  • 박상현;윤성도;정학수;국상훈
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1992년도 추계학술대회 논문집
    • /
    • pp.63-66
    • /
    • 1992
  • Using an aromatic system, we made a ultra thin insulator through LB-method. We measured and wrote down afternating currant characteristics of ultraviolet rays extincting-spectrum and I.R extincting-spectrum. We surveyed the thickness of a film through X-ray diffracting method and certified about $4{\AA}$ by the layer. Measuring the characteristics of direct current voltage and electric current with this sample, we produced its conductivity and discovered that this sample had a god insulating performance. Addition to this, we measured the characteristics of voltage and electric current, and the temperature dependency of conductivity in a high voltage system and with these results tried to interpret a mechanism of conduction.

  • PDF

Spin Dependent Transport Phenomena for Annealed Co46Al19O35 Granular Thin Films

  • Jae-Geun Ha
    • Journal of Magnetics
    • /
    • 제3권4호
    • /
    • pp.127-133
    • /
    • 1998
  • I have overviewed the change in GMR on annealing, in conjunction with the change in microstructure. The Co46Al19O35 granular thin films were annealed at 30$0^{\circ}C$ for various annealing time to change the microstructure. The magnitude of GMR decreases considerably with increasing annealing time, although the size of Co granules estimated from TEM observation show a small change. Parameter fits of magnetization curves and magnetoresistance curves to the Langevin function suggest that large clusters consisting of several small Co granules, which are coupled ferromagnetically, are related with the decrease of GMR on annealing. The temperature dependence of electrical resistivity ($\rho$) shows the relationship of log $\rho$ versus $T^{-1/2}$ for the sample annealed for 10 min., 1 hr. and 6 hrs. However, the sample annealed for 38 hrs. shows the relationship of log $\rho$ versus$ T^{-1/4},$ which represents a significant change in the transport mechanism.

  • PDF

Mg도핑된 GaN 반도체 박막의 전자스핀공명 (Electron Spin Resonance from Mg-doped GaN Semiconductor Thin Films)

  • 박효열
    • 반도체디스플레이기술학회지
    • /
    • 제4권2호
    • /
    • pp.1-5
    • /
    • 2005
  • Electon spin resonance measurements have been performed on the Mg-doped wurtzite GaN thin films grown on sapphire substrates by low-pressure metal-organic chemical vapor deposition. The sample set included films as-grown with the regular Mg doped and Mg delta doped samples and the corresponding annealed ones. The resonance signal has been observed from the annealed Mg delta-doped sample with the Lande g value of 2.029. This indicates that the singlet resonance signal originates from the neutral Mg acceptor located at 0.24 eV above the valence band edge and 0.13 eV above the Fermi level because of the nuclear hyperfine spin 1=0 of Mg and the larger value than the free electron g=2.0023.

  • PDF

Application of multimodal surfaces using amorphous silicon (a-Si) thin film for secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS)

  • Kim, Shin Hye;Lee, Tae Geol;Yoon, Sohee
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2016년도 제50회 동계 정기학술대회 초록집
    • /
    • pp.384.1-384.1
    • /
    • 2016
  • We reported that amorphous silicon (a-Si) thin film provide sample plate exhibiting a multimodality to measure biomolecules by secondary ion mass spectrometry (SIMS) and laser desorption/ionization mass spectrometry (LDI-MS). Kim et al.1 reported that a-Si thin film were suitable to detect small molecules such as drugs and peptides by SIMS and LDI-MS. Recently, bacterial identification has been required in many fields such as food analysis, veterinary science, ecology, agriculture, and so on.2 Mass spectrometry is emerging for identifying and profiling microbiology samples from its advantageous characters of label-free and shot-time analysis. Five species of bacteria - S. aureus, G. glutamicum, B. kurstaki, B. sphaericus, and B. licheniformis - were sampled for MS analysis without lipid extraction in sample preparation steps. The samples were loaded onto the a-Si thin film with a thickness of 100 nm which did not only considered laser-beam penetration but also surface homogeneity. Mass spectra were recorded in both positive and negative ionization modes for more analytical information. High reproducibility and sensitivity of mass spectra were demonstrated in a mass range up to mass-to-charge ratio(m/z) 1200 by applying the a-Si thin film in mentioned above MS. Principle component analysis (PCA) - a popular statistical analysis widely used in data processing was employed to differentiate between five bacterial species. The PCA results verified that each bacterial species were readily distinguished and differentiated effectively from our MS approach. It shows a new opportunity to rapid bacterial profiling and identification in clinical microbiology. More details will be discussed in the presentation.

  • PDF

Electron Tunneling and Electrochemical Currents through Interfacial Water Inside an STM Junction

  • Song, Moon-Bong;Jang, Jai-Man;Lee, Chi-Woo
    • Bulletin of the Korean Chemical Society
    • /
    • 제23권1호
    • /
    • pp.71-74
    • /
    • 2002
  • The apparent barrier height for charge transfer through an interfacial water layer between a Pt/Ir tip and a gold surface has been measured using STM technique. The average thickness of the interfacial water layer inside an STM junction was controlled by the amount of moisture. A thin water layer on the surface was formed when relative humidity was in the range of 10 to 80%. In such a case, electron tunneling through the thin water layer became the majority of charge transfers. The value of the barrier height for the electron tunneling was determined to be 0.95 eV from the current vs. distance curve, which was independent of the tip-sample distance. On the other hand, the apparent barrier height for charge transfer showed a dependence on tip-sample distance in the bias range of 0.1-0.5 V at a relative humidity of approximately 96%. The non-exponentiality for current decay under these conditions has been explained in terms of electron tunneling and electrochemical processes. In addition, the plateau current was observed at a large tip-sample distance, which was caused by electrochemical processes and was dependent on the applied voltage.

강유전정 액정 디스플레이의 배향을 위한 액정성 고분자 (Liquid Crystalline Polymer for the Alignment of Ferroelectric Liquid Crystal Display)

  • 진성호;전영재;이종천;김강
    • 한국재료학회지
    • /
    • 제10권5호
    • /
    • pp.350-353
    • /
    • 2000
  • 강유전성 액정 분자 배향을 위해 열방성 고분자 액정물질을 배향막으로 사용하고 그표면 morphology를 AFM(Atomic Forced Microscope)으로 관찰한 결과 잘 배향된 sample cell에서도 microgroove 구조가 나타나지 않았음을 관찰하였다. 잘 배향된 sample cell 23:1의 contrast ratio를 보이면서 memory 효과를 나타내었다. 또한 20V의 AC field로 안정화시키자 전형적인 stripe-shaped 무늬가 나타났다.

  • PDF

비귀금속 산화물이 치과용 합금과 도재의 화학적 결합에 미치는 영향 (Effects of Nonprecious Metallic Oxide on the Chemical Bonding Between Dental Alloy and Porcelain)

  • 김광남;조성암
    • 대한치과보철학회지
    • /
    • 제25권1호
    • /
    • pp.317-325
    • /
    • 1987
  • A study on the shear bonding strength between dental alloy and porcelain according to various kidns of sputtered metallic thin films was established by Ingtron universal testing machine, and the change of the elemental weight % at the surface of dental alloy was studied by E.D.S. The kind of metallic thin films were Al, Ni, In, Cr. Ti and Sn with $0.3{\mu}m$ thickness. The dental alloys were Verabond made by Aalba Dent. Co. and Degudent H manufactured by Degussa Co. The control groups were Verabond and Degudent H. The obtained results were as follows; 1. The shear bonding strength of Al plated sample was the strongest of all. 2. The shear bonding strength of Ni plated sample was stronger than that of Degudent H, Sn plated samples. 3. The shear bonding strength of Verabond was weaker than that of Al, Ni, In, Cr, plated samples. 4. After degassing, it is more weight % of Ni at the alloy surface of the Ni sputtered specimen than the Sn sputtered sample.

  • PDF

나노미터 크기의 미세구조물을 제작하기 위한 공정기술 개발 (Development of process technique of the alumina membrane with nano-sized pore array)

  • 이재홍;이병욱;김창교;이경호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.1971-1973
    • /
    • 2005
  • We fabricated an alumina membrane with nano-sized pore array by anodic oxidation using the thin film aluminum deposited on silicon wafer. It is important that the sample prepared by metal deposition method has a flat aluminum surface and a good adhesion between the silicon wafer and the thin film aluminum. The oxidation time was controlled by observation of current variation. The nano-sized pores with diameter of $60{\sim}120nm$ was obtained by $40{\sim}80$ voltage. The pore widening process was employed for obtaining the flat surface because the pores of the alumina membrane prepared by the fixed voltage method shows the structure of rough surface. Finally, the sample was immersed to the phosphoric acid with 0.1M concentration to etching the barrier layer. The sample will be applied to electronic sensors, field emission display, and template for nano- structure.

  • PDF

Cross-Sectional Transmission Electron Microscopy Sample Preparation of Soldering Joint Using Ultramicrotomy

  • Bae, Jee-Hwan;Kwon, Ye-Na;Yang, Cheol-Woong
    • Applied Microscopy
    • /
    • 제46권3호
    • /
    • pp.167-169
    • /
    • 2016
  • Solder/electroless nickel immersion gold (ENIG) joint sample which is comprised of dissimilar materials with different mechanical properties has limited the level of success in preparing thin samples for transmission electron microscopy (TEM). This short technical note reports the operation parameters for ultramicrotomy of solder joint sample and TEM analysis results. The solder joint sample was successfully sliced to 50~70 nm thick lamellae at slicing speed of 0.8~1.2 mm/s using a boat-type $45^{\circ}$ diamond knife. Ultramicrotomy can be applied as a routine sample preparation technique for TEM analysis of solder joints.